RADIOLOGICAL EVALUATION OF FRACTURE LINE STABILITY DURING FUNCTIONAL LOADING AFTER MINIPLATE FIXATION OF MANDIBULAR ANGLE FRACTURES (하악 우각부 골절의 소형금속판 내고정 후 기능시 골접합선의 안정도에 관한 방사선학적 평가)

  • Suh, Chang-Ho;Bae, Jung-Soo;Chin, Byung-Rho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.428-434
    • /
    • 2001
  • After miniplate fixation of mandibular angle fractures, fracture line stability during functional loading was evaluated. Using panoramic radiographs, 15 mandibular angle fracture patients who were treated by open reduction and one miniplate fixation along the external oblique ridge, were evaluated at postoperative 1, 4 and 8 weeks. At each time, 2 radiographs were taken: one taken during maximum biting of hardened silicone sheet on the affected side molar area and the other on the non-affected side. The distraction gap of inferior border of mandible at each time and each side was measured and these data were analysed statistically with clinical findings. The differences of inferior border distraction gap during hardened silicone sheet biting on the affected side molar area and on the non-affected side molar area at 4 week radiographs were smaller than those of 1 week's except one case. At 8 week's radiographs, the fracture lines were so stabilized that it was almost impossible to find the gap differences except one case and there were increased radiopacity along the entire fracture lines. Clinically, bony union was confirmed in all cases during plate removal performed at postoperative 6 month. By statistical analysis(paired t-test), the inferior border distraction gap during biting of hardened silicone sheet on the affected side was significantly reduced during 1 and 4 week interval(p<0.01). The differences of inferior border distraction gap during biting on the affected side molar area and on the non-affected side molar area were also significantly reduced at 1 and 4 week interval(p<0.01). But the inferior border distraction(compression) gap during non-affected side biting was not significantly changed. From these findings, it could be concluded that fracture line stability during functional loading after one miniplate fixation of mandibular angle fractures stems mainly from reduction of inferior border distraction gap during affected side biting on time interval. According to these radiographic and clinical findings, the clinical superiority of one miniplate fixation technique in mandibular angle fracture treatment could be confirmed.

  • PDF

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.

Late-onset Brachial Artery Occlusion caused by Subclavian Artery Stenosis after Clavicular Fracture: A Case Report

  • Cho, Chul-Hyun;Song, Kwang-Soon;Min, Byung-Woo;Bae, Ki-Cheor
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.175-175
    • /
    • 2008
  • We report a rare case of late-onset brachial artery occlusion caused by subclavian artery stenosis with excessive scar tissue after open reduction and plate fixation for clavicular fracture. When he referred to us, the right hand were pale and the radial and ulnar pulses at the wrist were absent. CT-angiogram showed compression of subclavian artery by excessive scar tissue beneath the fracture site and angiography revealed stenosis of subclavian artery with thrombus and complete obstruction of blood flow in the brachial artery with emboli. Therefore, we performed embolectomy. 2 years after operation, patient was essentially asymptomatic except mild pain after long standing elevation of arm. We recommend that minimal soft tissue dissection should be needed in the operative treatment of clavicular fracture, especially soft tissue beneath the clavicle should be protected maximally.

  • PDF

Complex open elbow fracture-dislocation with severe proximal ulna bone loss: a case report of massive osteochondral allograft surgical treatment

  • Concina, Chiara;Crucil, Marina;Theodorakis, Emmanouil;Saggin, Giorgio;Perin, Silvia;Gherlinzoni, Franco
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • We report a case of a 69-year-old right-dominant man who had an open Monteggia-like lesion of the right elbow (Gustilo-Andersen IIIA) with severe proximal ulna bone loss associated with an ipsilateral ulnar shaft fracture due to a motorcycle accident. The patient underwent two-stage surgery. Wound debridement and bridging external fixation were performed at first. Three months later, a frozen massive osteochondral ulnar allograft was implanted and fixed with a locking compression plate. A superficial wound infection appeared 5 weeks after the second surgery. Superficial wound debridement, negative pressure therapy, and antibiotics were administered for 3 months, achieving infection healing. At 3 years post-surgery, the elbow range of motion was satisfactory with a Disabilities of the Arm, Shoulder and Hand (DASH) score of 16.7. Radiographs and computed tomography scans showed good allograft-bone integration without allograft reabsorption or hardware loosening. Although not complication-free, massive ulna osteochondral allograft implantation can be considered a valid option in cases of open Monteggia-like lesions associated with ulnar shaft fracture and severe bone loss in active patients, whenever osteosynthesis or joint replacement is not a proper solution. This type of bone stock restoration allows for future surgery, if needed.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES (하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구)

  • Ku, Je-Hoon;Kim, Il-Kyu;Chang, Jae-Won;Yang, Jung-Eun;Sasikala, Balaraman;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

A Case of Tuberculous Spondylitis Combined with Schwannoma of Spinal Cord - A Case Report - (척수 신경초종을 동반한 결핵성 척추염 1례 - 증례보고 -)

  • Park, Jong Hoon;Kim, Kyu Hong;Lee, Woon Gi;Choi, Jeong Hoon;Lee, In Chang;Bae, Sang Do
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1241-1244
    • /
    • 2001
  • The authors report a very rare case of tuberculous spondylitis combined with a schwannoma of spinal cord. A 39- year-old man was admitted because of paraparesis(G1/G2). MRI showed severe cord compression at two different levels. One was by the bulged soft tissue and subligamentous abscess extending from T7 to T9 and the other was by an intradural extramedullary cord tumor at the level of T1-2. At first operation, T8 corpectomy and T7-9 plate fixation with autogenous iliac bone graft were performed. After then, Paraparesis was improved(G2/G3) postoperatively. The second operation underwent two weeks later. The tumor was totally removed and shortly after second operation, paraparesis was markedly improved(G3/G4). Histological diagnosis were tuberculous spondylitis and schwannoma, respectively. The authors reviewed this case where good surgical outcome was obtained by two stage operation.

  • PDF

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.

A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure- (대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구)

  • Jeon, Chun-Bae;Seo, Jae-Sung;Ahn, Jong-Chul;Ahn, Myun-Whan;Ihn, Joo-Chyl
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • The author fractographically analyized the cause of metal failure(the first time this procedure has been used for this metal failure)and also analyized it clinically. In this study, I selected eight cases which have been analyized fractographically. In all these cases, the analysis was done after treatment of metal failure of implants internally fixed to femur shaft fractures at the Department of Orthopedic Surgery, Yeung-Nam University Hospital during the six year period from May 1983 to September 1989. 1. Metal failure occured in five dynamic-compression plates, one Jewett nail, one screw in Rowe plate, and one interlocking nail. 2. The clinical cause of metal failure was deficiency of medial butress in five cases, incorrect position of implant in one case, and incorrect selection of implant in two cases. 3. The time interval between internal fixation and metal failure was four months in one case, between five months to twelve months in six cases, three years in one case. 4. The fractographically analytical cause of metal failure was ; first, impact failure, one case, second, fatigue failure, six cases, machining mark(stress liser), four cases type : low consistent cyclic fatigue failure irregular cyclic fatigue failure third, stress corrosion crack, one case. 5. 316L Stainless Steel has good resistance to corrosion. However, when its peculiar surface film is destroyed by fretting, it shows pitting corrosion. This is, perhaps, the main cause of metal failure. 6. It is possible that mechanical injury occured in implants during the manufacturing of implants or that making a screw hole is the main cause of metal failure.

  • PDF

Treatment of Pseudoarthrosis due to Nonunion of the Acromial Fracture with LCP - Case Report - (견봉 골절의 불유합으로 기인한 가관절증의 잠김 금속판을 이용한 치료 - 증례보고 -)

  • Kim, Yong-Min;Park, Kyoung-Jin;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Keum, Sang-Wook;Jeong, Ho-Seung
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2013
  • A painful pseudoarthrosis will develop due to a delay in diagnosis and treatment, and surgical care is required. Treatment of pseudoarthrosis is really difficult because the acromion is a thin flat bone that is difficult to be fixed firmly. A 52-year-old woman with multiple trauma had an acromial fracture that was not detected until it had caused pain after ambulation. Open reduction and internal fixation with a variable angle locking compression plate for distal radius and autogenous iliac bone graft were performed. At nine months after the operation, there was partial tear in the supraspinatus tendon, and arthroscopic repair of the supraspinatus tendon was performed. At nine months after the operation, radiographs showed a complete union. At three months after tendon repair, the patient had excellent function of the shoulder. We have reported a case of a successful treatment of nonunion and pseudoarthrosis of acromial fracture that is difficult to be fixed.