• Title/Summary/Keyword: Compression plate fixation

Search Result 51, Processing Time 0.023 seconds

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Tibial Fracture Repair in a Black Gibbon (Hylobates concolor) (긴팔원숭이에서 발생한 경골 골절의 외과적 정복 1례)

  • Yoon, Hun-Young;Lee, Bo-Ra;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.644-646
    • /
    • 2009
  • A 5-year-old intact male black gibbon (Hylobates concolor) was referred for evaluation of the right pelvic limb lameness following a fight against other black gibbons. Fractures of the right tibia and fibula were suspected on physical examination and palpation of the right pelvic limb, but no other injuries or abnormalities were detected. While the black gibbon was sedated, pelvic limb radiographs were taken, which revealed diaphyseal oblique fractures of the right tibia and fibula. Open reduction of the fractures was performed. The tibial fracture was repaired by use of an internal fixation technique that included a tubular dynamic compression plate and cortical screws secured along the craniomedial aspect of the tibia. There were no complications during the postoperative rehabilitation period. At 9 weeks, radiographs revealed that bridging callus was well formed over the cortices of the tibial and fibular fracture area. The cast was removed 9 weeks after surgery. The black gibbon exhibited no evidence of lameness and was released back into the group. Presently, there are no published reports of internal fracture fixation in a black gibbon where a tubular dynamic compression plate and cortical screws provided excellent stabilization of the tibia and complete fracture healing allowing normal ambulation.

Hook Plate Fixation for Isolated Greater Tuberosity Fractures of the Humerus

  • Lee, Kyoung-Rak;Bae, Ki-Cheor;Yon, Chang-Jin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.222-229
    • /
    • 2017
  • Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.

Practicability Strength Assessment of a Bone Metallic Plate at the Femur Fixation (대퇴골(Femur)고정용 골 금속판 제작 및 강도 평가)

  • Kim, Jeong-Lae;Ahn, Chang-Sik;Seo, Byoung-Do
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.

Operative Treatment of Fractures of the Midshaft Clavicle using Locking Compression Plate (Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Chung, Nam-Sik;Hong, Ki-Do;Ha, Sung-Sik;Park, Sung-Joon;Kang, Jung-Ho;Sim, Jae-Cheon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Purpose: To assess the effectiveness of the Locking compression plate (LCP) after open reduction for the treatment of the displaced clavicular shaft fracture, the clinical and radiologic outcome of the patients who were managed with the LCP for internal fixation after open reduction has been analyzed. Materials and Methods: We reviewed 26 cases with a displaced clavicular shaft fracture treated by internal fixation using Locking compression plate after open reduction between May 2003 and November 2004. The patients were followed up for at least six months period, and final postoperative outcome was evaluated using clinical results based on Kang's criteria, radiologic signs of fusion. Results: All fractures united by an average of 9.3 weeks without delayed union and showed fast recovery of motion fraction and shoulder function. In addition,24 cases without the fractures of proximal humerus recovered to normal range of shoulder notion within 2.9 weeks. Clinically, according to Kang's criteria, the outcome was good or better in 22 patients. The complications included shoulder joint dysfunction in two cases and keloid formation in one case, and no other complications were observed. Conclusion: The internal fixation using LCP for the treatment of displaced clavicular shaft fracture is a safe, reliable method of treatment, with few complications, and offers rapid recovery of shoulder joint function and bone union.

  • PDF

THE DEVELOPMENT OF SUS 316L BONE PLATE FORGING PROCESS BY COMPUTER SIMULATION TECHNOLOGY

  • Hwang Robert S.;Jou Jin-Long;Wang Kai-Hung;Chen Yi-An
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.36-39
    • /
    • 2003
  • Due to the strength and biocompatibility requirement, the stainless steel SUS 316L is widely used for trauma internal fixation device. SUS 316L can be hardened and strengthened only by cold work. In this work, the material compression test is performed both in laboratory and computer simulation by a FEM analysis software DEFORM to correlate the hardness to strain. This data is then used for preform design and predict the hardness of the finish bone plate forging. Finally, we compared the hardness between the actual forging and computer analysis results. Although the predicted hardness from computer simulation. is 55HV higher than the final forging sample, we can get good compatibility on the hardening tendency of cold forging.

  • PDF

The Result of Open Reduction and Fixation in Sternal Fracture with Displacement (흉골 전위골절에 대한 수술적 정복고정술의 결과)

  • Kim, Young-Jin;Cho, Hyun-Min
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.175-179
    • /
    • 2010
  • Purpose: Sternal fractures after blunt thoracic trauma can cause significant pain and disability. They are relatively uncommon as a result of direct trauma to the sternum and open reduction is reserved for those with debilitating pain and fracture displacement. We reviewed consecutive 11 cases of open reduction and fixation of sternum and tried to find standard approach to the traumatic sternal fractures with severe displacement. Methods: From December 2008 to August 2010, the medical records of 11 patients who underwent surgical reduction and fixation of sternum for sternal fractures with severe displacement were reviewed. We investigated patients' characteristics, chest trauma, associated other injuries, type of open reduction and fixation, combined operations, preoerative ventilator support and postoperative complications. Results: The mean patient age was 59.3years (range, 41~79). The group comprised 6 male and 5 female subjects. Among 11 patients who underwent open reduction and fixation for sternal fracture with severe displacement, 6 cases had isolated sternal fractures and the other 5 patients had associated other injuries. Sternal fractures were caused by car accidents (9/11, 81.8%), falling down (1/11, 9.1%) and direct blunt trauma to the sternum (1/11, 9.1%), respectively. 3 of the 7 patients (42.9%) who underwent sternal plating with longitudinal plates showed loosening of fixation. Otherwise, none of the 4 patients who underwent surgical fixation using T-shaped plate had stable alignment of the fracture. Conclusion: Sternal fractures with severe displacement need to be repaired to prevent chronic pain, instability of the anterior chest wall, deformity of the sternum, and even kyphosis. In the present study, a T-shaped plate with a compression-tension mechanism constitutes the treatment of choice for displaced sternal fractures.

THE CLINICAL STUDY OF MANDIBULAR FRACTURE

  • Lee, Dong-Keun;Yim, Chang-Joon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 1989
  • This is a retrospective study on 219 patients with mandibular fracture. The patients were treated in the Dept. of Oral Maxillofacial Surgery of WON KWANG UNIV. HOSPITAL from Aug. 1, 1984 to Sept. 30. 1988. The results were as follows. 1. The mandibular fractures occured most frequently in the twenties(35%) and male were predominant (74.7%) than females. 2. The most frequent etiologic factor was traffic accident(34.3%). 3. The most common location of fracture was symphysis(37.1%). And angle(27.6%), condyle(25.7%), ramus(1.6%) were next in order of frequency. 4. In mandible fracture, they have an average 1.8 fracture line. 5. The use of plate & screw system were more increased in the comparison of each year. 6. Intermaxillary fixation period was more reduced from the concept of 6 weeks fixation, due to the use of Plate & screw system. 7. Postoperative acute wound infection was developed 9.6% in 219 mandibular fracture patients. The compression osteosynthesis was most common cause of acute wound infection than any other treatment method. 8. Postoperative malocclusion was developed 4% in 219 mandibular fracture. And the compression osteosynthesis was most common cause of malocclusion. 9. Acute wound infection was detailed by the approach method. The Intraoral & extraoral combination method was most common cause on acute infection and intraoral, extraoral approach method was next in order of frequency. 10. Normal mouth opening process was proportioned to IMF period. The short IMF period have a fast normal mouth opening process.

  • PDF

Clinical Outcomes of Combinations of Locking Compression Plate Fixation through Minimally Invasive Precutaneous Plate Osteosynthesis and Interfragmentary Screw Fixation in Distal Tibia Fracture (경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과)

  • Chung, Hyung-Jin;Choo, Ji Woong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.