Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.
A 5-year-old intact male black gibbon (Hylobates concolor) was referred for evaluation of the right pelvic limb lameness following a fight against other black gibbons. Fractures of the right tibia and fibula were suspected on physical examination and palpation of the right pelvic limb, but no other injuries or abnormalities were detected. While the black gibbon was sedated, pelvic limb radiographs were taken, which revealed diaphyseal oblique fractures of the right tibia and fibula. Open reduction of the fractures was performed. The tibial fracture was repaired by use of an internal fixation technique that included a tubular dynamic compression plate and cortical screws secured along the craniomedial aspect of the tibia. There were no complications during the postoperative rehabilitation period. At 9 weeks, radiographs revealed that bridging callus was well formed over the cortices of the tibial and fibular fracture area. The cast was removed 9 weeks after surgery. The black gibbon exhibited no evidence of lameness and was released back into the group. Presently, there are no published reports of internal fracture fixation in a black gibbon where a tubular dynamic compression plate and cortical screws provided excellent stabilization of the tibia and complete fracture healing allowing normal ambulation.
Background: The purpose of this study was to investigate the outcomes after fixation using a 3.5-mm locking compression plate (LCP) hook plate for isolated greater tuberosity (GT) fractures of the proximal humerus. Methods: We evaluated the postoperative radiological and clinical outcomes in nine patients who were followed up at least 1 year with isolated GT fractures. Using the deltopectoral approach, we fixed the displaced GT fragments with a 3.5-mm LCP hook plate (Synthes, West Chester, PA, USA). Depending on the fracture patterns, the hook plate was fixed with or without augmentation using either tension suture or suture anchor fixation. Results: All the patient showed successful bone union. The mean time-to-union was 11 weeks. The radiological and clinical outcomes at the final follow-up were generally satisfactory. The mean visual analogue scale for pain, the University of California at Los Angeles score, the American Shoulder and Elbow Surgeons score, and the subjective shoulder value were 1.4, 30.3, 84.3, and 82.2%, respectively. The mean active forward flexion, abduction, external rotation, and internal rotation of the shoulder were $156.7^{\circ}$, $152.2^{\circ}$, $61.1^{\circ}$, and the 10th thoracic vertebral level, respectively. Only one patient presented with a postoperative complication of shoulder stiffness. The patient was treated through arthroscopic capsular release on the 5th postoperative month. Conclusions: We conclude that fixation using 3.5-mm LCP hook plates for isolated GT fractures of the proximal humerus is a useful treatment method that provides satisfactory clinical and radiological outcomes.
Study was developed the metallic plate for fixation in the femur fracture and plates has a firm place in fracture treatment. This plates can be stabilized for fracture fixation as well as biological and dynamical device. The device's designation and sizing has a optimization with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. The bending strength of the curved metallic long plate has to evaluate a 11,000N and the bending strength of the curved metallic short plate has to evaluate a 6,525N. This see the X-ray image of bending angle made certain of 15$^{\circ}$ at number 2 and same 82.87$^{\circ}$ at number 2, 4, 5, 7, 8, 9, 10 by outside angle, and confirmed 25.26$^{\circ}$ at number 3, 3.68$^{\circ}$ at number 6, 15.64$^{\circ}$ at number 9 by inside angle. This study shows that keep up the metallic plate for fixation in the femur fracture through X-ray Image and the device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture. Short plate have a wrapping of femur and long plate have to preserve a pole of femur.
Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
Clinics in Shoulder and Elbow
/
v.11
no.2
/
pp.143-149
/
2008
Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.
Purpose: To assess the effectiveness of the Locking compression plate (LCP) after open reduction for the treatment of the displaced clavicular shaft fracture, the clinical and radiologic outcome of the patients who were managed with the LCP for internal fixation after open reduction has been analyzed. Materials and Methods: We reviewed 26 cases with a displaced clavicular shaft fracture treated by internal fixation using Locking compression plate after open reduction between May 2003 and November 2004. The patients were followed up for at least six months period, and final postoperative outcome was evaluated using clinical results based on Kang's criteria, radiologic signs of fusion. Results: All fractures united by an average of 9.3 weeks without delayed union and showed fast recovery of motion fraction and shoulder function. In addition,24 cases without the fractures of proximal humerus recovered to normal range of shoulder notion within 2.9 weeks. Clinically, according to Kang's criteria, the outcome was good or better in 22 patients. The complications included shoulder joint dysfunction in two cases and keloid formation in one case, and no other complications were observed. Conclusion: The internal fixation using LCP for the treatment of displaced clavicular shaft fracture is a safe, reliable method of treatment, with few complications, and offers rapid recovery of shoulder joint function and bone union.
Hwang Robert S.;Jou Jin-Long;Wang Kai-Hung;Chen Yi-An
Proceedings of the Korean Society for Technology of Plasticity Conference
/
2003.10b
/
pp.36-39
/
2003
Due to the strength and biocompatibility requirement, the stainless steel SUS 316L is widely used for trauma internal fixation device. SUS 316L can be hardened and strengthened only by cold work. In this work, the material compression test is performed both in laboratory and computer simulation by a FEM analysis software DEFORM to correlate the hardness to strain. This data is then used for preform design and predict the hardness of the finish bone plate forging. Finally, we compared the hardness between the actual forging and computer analysis results. Although the predicted hardness from computer simulation. is 55HV higher than the final forging sample, we can get good compatibility on the hardening tendency of cold forging.
Purpose: Sternal fractures after blunt thoracic trauma can cause significant pain and disability. They are relatively uncommon as a result of direct trauma to the sternum and open reduction is reserved for those with debilitating pain and fracture displacement. We reviewed consecutive 11 cases of open reduction and fixation of sternum and tried to find standard approach to the traumatic sternal fractures with severe displacement. Methods: From December 2008 to August 2010, the medical records of 11 patients who underwent surgical reduction and fixation of sternum for sternal fractures with severe displacement were reviewed. We investigated patients' characteristics, chest trauma, associated other injuries, type of open reduction and fixation, combined operations, preoerative ventilator support and postoperative complications. Results: The mean patient age was 59.3years (range, 41~79). The group comprised 6 male and 5 female subjects. Among 11 patients who underwent open reduction and fixation for sternal fracture with severe displacement, 6 cases had isolated sternal fractures and the other 5 patients had associated other injuries. Sternal fractures were caused by car accidents (9/11, 81.8%), falling down (1/11, 9.1%) and direct blunt trauma to the sternum (1/11, 9.1%), respectively. 3 of the 7 patients (42.9%) who underwent sternal plating with longitudinal plates showed loosening of fixation. Otherwise, none of the 4 patients who underwent surgical fixation using T-shaped plate had stable alignment of the fracture. Conclusion: Sternal fractures with severe displacement need to be repaired to prevent chronic pain, instability of the anterior chest wall, deformity of the sternum, and even kyphosis. In the present study, a T-shaped plate with a compression-tension mechanism constitutes the treatment of choice for displaced sternal fractures.
This is a retrospective study on 219 patients with mandibular fracture. The patients were treated in the Dept. of Oral Maxillofacial Surgery of WON KWANG UNIV. HOSPITAL from Aug. 1, 1984 to Sept. 30. 1988. The results were as follows. 1. The mandibular fractures occured most frequently in the twenties(35%) and male were predominant (74.7%) than females. 2. The most frequent etiologic factor was traffic accident(34.3%). 3. The most common location of fracture was symphysis(37.1%). And angle(27.6%), condyle(25.7%), ramus(1.6%) were next in order of frequency. 4. In mandible fracture, they have an average 1.8 fracture line. 5. The use of plate & screw system were more increased in the comparison of each year. 6. Intermaxillary fixation period was more reduced from the concept of 6 weeks fixation, due to the use of Plate & screw system. 7. Postoperative acute wound infection was developed 9.6% in 219 mandibular fracture patients. The compression osteosynthesis was most common cause of acute wound infection than any other treatment method. 8. Postoperative malocclusion was developed 4% in 219 mandibular fracture. And the compression osteosynthesis was most common cause of malocclusion. 9. Acute wound infection was detailed by the approach method. The Intraoral & extraoral combination method was most common cause on acute infection and intraoral, extraoral approach method was next in order of frequency. 10. Normal mouth opening process was proportioned to IMF period. The short IMF period have a fast normal mouth opening process.
Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.