• Title/Summary/Keyword: Compression level

Search Result 798, Processing Time 0.023 seconds

BTC Algorithm Utilizing Multi-Level Quantization Method for Image Compression (Multi-Level 양자화 기법을 사용한 BTC 영상 압축 알고리즘)

  • Cho, Moonki;Yoon, Yungsup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.114-121
    • /
    • 2013
  • BTC image compression is a simple and easy hardware implementation, is widely used in a video compression techniques required for LCD overdrive. In this paper, methods for reducing compression loss, a multi-level quantization BTC (MLQ-BTC) algorithm is proposed. The process of the MLQ-BTC algorithm is, a input image is compressed and decompressed by Quasi 8-level method and Advanced 2-level BTC method, and select the algorithm with the smallest compression loss. Simulation results show that the proposed algorithm is efficient as compared with PSNR and compression ratio of the existing BTC methods.

Electroencephalography Relative Alpha Spectrum and Subjective Preference Based on Compression Level of Arm According to Region (상지 부위별 압박수준에 따른 EEG 상대 알파파 스펙트럼과 주관적 선호도 분석)

  • Park, Sunhee;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.2
    • /
    • pp.310-320
    • /
    • 2022
  • This study aimed to ascertain the most efficient level of compression to be applied on a particular area along the upper extremities whilst developing functionality to prevent musculoskeletal disorders among workers who frequently use their arms. The compression areas were divided into upper arm, forearm, and wrist. The compression levels were applied using three types of bands. Comparisons on these bands' usability were based on evaluations of recorded brainwaves and subjective sensation response. Nine men in their twenties were selected for the experiment. The results revealed that when compression was applied, the left and right occipital lobes, plus the parietal lobe, were activated. Also, the alpha wave activity tended to increase, thereby exemplifying the compression's positive effects. The most physiologically efficient and subjectively preferred compression levels were 1.3 and 2.6 kPa for the upper arm and wrist. Furthermore, the compression level at the forearm should be at least 2.0 kPa.

Improvement of Image Sensor Performance through Implementation of JPEG2000 H/W for Optimal DWT Decomposition Level

  • Lee, Choel;Kim, BeomSu;Jeon, ByungKook
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.68-75
    • /
    • 2017
  • In this paper, a particular application of digital photos, remote sensing, remote shooting air moving, high-resolution and high compression of medical images required by remote shooting of JPEG2000 standard applied in the field of hardware design, production was implemented. JPEG2000 standard for image compression using the software implementation of the processing speed is very slow compared to conventional JPEG disadvantages, and also the standard of JPEG2000 DWT (Discrete wavelet transform) to improve the level of compression for image data if processing speed is a phenomenon that has degraded. In order to solve these JPEG2000 compression / decompression groups were designed and applied. In this paper, the optimal JPEG2000 compression / reservoir hardware by changing the level for still image compression, faster computation speed and quality has shown improvement.

Studies on Variability of Wood Properties in Stem of Pinus koraiensis (II) - Differences in Tracheid Length, Microfibril Angle, and Compression Strength in South and North Sides of Stem -

  • Kim, Byung-Ro;Mishiro, Akiyoshi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.45-50
    • /
    • 1998
  • Tracheid length, microfibril angle, and compression strength were examined in south and north sides of Pinus koraiensis. The sample tree was 57 years old and had been planted in central Korea. Tracheid length on the south side of the tree ranged from 2.87 to 3.40mm and on the north ranged from 3.60 to 3.53mm and mean values were 3.15 mm for the south and 3.26mm for the north. Tracheid length was 0.11 mm longer on the north side than on the south. Microfibril angle on the south side ranged from $12.6^{\circ}$ to $20.3^{\circ}$ and that on the north from $6.8^{\circ}$ to $13.5^{\circ}$; mean values were $16.6^{\circ}$ on the south side and $9.6^{\circ}$ on the north. Microfibril angle was $7.0^{\circ}$ greater on the south side than on the north side. For compression strength on the south and north sides, significant difference at the 95% level was found only at l.3m above the ground level of the sample tree; for compression limit stress, significant difference at this level was found at 1.3 and 5.3m above the ground level. However, compression strength and compression limit stress were greater on the north side than on the south side.

  • PDF

An Efficient Bit-Level Lossless Grayscale Image Compression Based on Adaptive Source Mapping

  • Al-Dmour, Ayman;Abuhelaleh, Mohammed;Musa, Ahmed;Al-Shalabi, Hasan
    • Journal of Information Processing Systems
    • /
    • v.12 no.2
    • /
    • pp.322-331
    • /
    • 2016
  • Image compression is an essential technique for saving time and storage space for the gigantic amount of data generated by images. This paper introduces an adaptive source-mapping scheme that greatly improves bit-level lossless grayscale image compression. In the proposed mapping scheme, the frequency of occurrence of each symbol in the original image is computed. According to their corresponding frequencies, these symbols are sorted in descending order. Based on this order, each symbol is replaced by an 8-bit weighted fixed-length code. This replacement will generate an equivalent binary source with an increased length of successive identical symbols (0s or 1s). Different experiments using Lempel-Ziv lossless image compression algorithms have been conducted on the generated binary source. Results show that the newly proposed mapping scheme achieves some dramatic improvements in regards to compression ratios.

An Efficient DNA Sequence Compression using Small Sequence Pattern Matching

  • Murugan., A;Punitha., K
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.8
    • /
    • pp.281-287
    • /
    • 2021
  • Bioinformatics is formed with a blend of biology and informatics technologies and it employs the statistical methods and approaches for attending the concerning issues in the domains of nutrition, medical research and towards reviewing the living environment. The ceaseless growth of DNA sequencing technologies has resulted in the production of voluminous genomic data especially the DNA sequences thus calling out for increased storage and bandwidth. As of now, the bioinformatics confronts the major hurdle of management, interpretation and accurately preserving of this hefty information. Compression tends to be a beacon of hope towards resolving the aforementioned issues. Keeping the storage efficiently, a methodology has been recommended which for attending the same. In addition, there is introduction of a competent algorithm that aids in exact matching of small pattern. The DNA representation sequence is then implemented subsequently for determining 2 bases to 6 bases matching with the remaining input sequence. This process involves transforming of DNA sequence into an ASCII symbols in the first level and compress by using LZ77 compression method in the second level and after that form the grid variables with size 3 to hold the 100 characters. In the third level of compression, the compressed output is in the grid variables. Hence, the proposed algorithm S_Pattern DNA gives an average better compression ratio of 93% when compared to the existing compression algorithms for the datasets from the UCI repository.

Influence of Clothing Pressure on Blood Flow and Subjective Sensibility of Commercial Sports Compression Wear (시판 스포츠 컴프레션 웨어의 의복압이 혈류 및 주관적 감성에 미치는 영향)

  • Kim, Nam Yim;Lee, Hyojeong
    • Fashion & Textile Research Journal
    • /
    • v.21 no.4
    • /
    • pp.459-467
    • /
    • 2019
  • Compression wear provides clothing pressure and affects how blood flows. Facilitating a blood flow is one of the most important functions of compression wear. The wearer's sensibility should be considered when designing compression wear. This study instructed participants to put on 5 types of sport compression wear with different pressure levels (CP-1 to CP-5), measured clothing pressure, blood flow level, blood flow rate, and surface temperature, and examined the pressure level that influenced blood flow through a subjective sensibility assessment. An experiment measured the clothing pressure of compression wear available in the market and found that the pressure ranged 0.6-1.1 kPa for the ankle, 0.7-2.3 kPa for the calf, and 0.9-1.9 kPa for the thigh. Meanwhile, blood flow levels and rates significantly increased when participants wore CP-1, which had the highest clothing pressure level, and CP-2 and CP-4 with middle-level pressure. After exercise, CP-2's surface temperature was the highest and revealed that wearing CP-2 facilitated blood flow. CP-2 was evaluated as most positive in the sensibility assessment and showed a clothing pressure of 0.67-1.82 kPa; its pressure for the calf did not surpass 2.0 kPa. Considering positive physical effect of compression wear on blood flow and subjective psychological effect on participants, CP-2 (0.67-1.82 kPa) would have the most suitable clothing pressure level among other types of the wear in this study.

Conservative treatment of Osteoporotic Compression Fractures in Thoracolumbar spine (골다공증성 흉요추부 압박 골절에서의 보존적 치료)

  • Kang, Kyu-Bok;Koh, Young-Do
    • Journal of Trauma and Injury
    • /
    • v.18 no.2
    • /
    • pp.107-111
    • /
    • 2005
  • Backgrounds: To evaluate the effectiveness of conservative treatment in osteoporotic thoraco-lumbar compression fractures and to identify the factors influencing the progression of compression. Materials and Methods: From January 2003 to October 2004, Patients who were admitted to our hospital for osteoporotic thoraco-lumbar compression fractures were reviewed retrospectively with follow-up more than 12 months (ave. 14.6 months). With simple x-ray lateral view, we evaluate wedge compression ratio (WCR) and kyphotic angle (KA) at initial and final follow-up. We separate the patients into two groups baesed on the amount of progression of vertebral compression and evaluate a relation with BMD, vertebral fracture level, initial WCR, initial KA. All datas were statistically analyzed. Results: An average of T-score was -3.5 and the changes of KA between initial and final follow-up were average $3.5^{\circ}$. Compression of anterior column were progressed to 8.5%. The changes between initial and final WCR in Group I (N=24) was 17.8%, and Group II (N=18) was 3.3%. T-score in group I was -3.4 and group II was -3.8 (p=0.228). vertebral fracture level were 10 T12, 12 L1, 2 L2 in group I; 6 T12, 6 L1, 6 L2 in group II (p=0.156). Initail WCR was 0.74 in group I, 0.63 in group II, and there was statistical difference between two groups(p=0002). Initial kyphotic angle was $13.9^{\circ}$in group I, $16.2^{\circ}$in group II repectively (p=0.392). Conclusion: The conservative treatment with short-term bed rest and early embulation is effective and valuable method to patients who have osteoporotic thoraco-lumbar compression fractures. There was no statistical difference between two groups according to BMD, vertebral fracture level, KA. But in comparison with initail WCR between two groups, there was statistical difference. That means, in the case of small initial compression of anterior column, the progression of compression was bigger than else. In these patients, more strict use of appropriate brace and careful follow-up should be needed.

Effects of 3D Compression Suits on EEG Analysis during and after Walking (운동 중과 휴식 시 3D 컴프레션 수트 착용에 따른 정량적 뇌파 분석)

  • Choi, Jiyoung;Kim, Namyim;Wu, Yanjun;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.440-454
    • /
    • 2014
  • This study examined the wearing effect of 3D compression suits on quantitative electroencephalogram (EEG) during walking and rest. Ten males in their 20s wore three types of experimental clothing, a loose-fit wear (BS), a 3D compression suit (3D CS), and a power film welded on CS (3D WCS); in addition, EEG signals were measured during resting, walking, after walking, and after sit-ups. The results showed that a higher pressure (due to 3D CS and 3D WCS) increased the 'Concentration' level and the 'Cognitive load' of brain waves during treadmill walking due to a higher cortex activity level when walking. Differentiation was shown between two compression suits and BS was enhanced during walking on a treadmill; however, the brain waves of 'Relaxation' between two compression suits were significantly different after walking, i.e., 'Relaxation' level of 3D WCS was the highest. Rigorous exercise such as sit-ups was inefficient to distinguish the effect of compression suits on EEG. Participants perceived a higher pressure due to compression suits; however, the wear comfort of two compression suits was maintained. Two compression suits were rated as supportive and helpful during walking. Various EEG parameters such as the indices of 'Relaxation', 'Concentration' and 'Cognitive load' were effective to observe the effect of 3D compression suits on wearers' brain waves during and after walking.

Vowel Compression due to Syllable Number in English and Korean

  • Yun, Il-Sung
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.165-173
    • /
    • 2002
  • Strong compression effects in a stressed vowel due to the addition of syllables have been adopted as evidence for stress-timing. In relation to this, Yun (2002) investigated the compression effects of number of syllables on Korean vowel. The results generally revealed that Korean had neither significant nor consistent anticipatory or backwards compression effects, especially when it came to the sentence level. This led us to claim that Korean would not be a stress-timed language. But the language investigated in the study was only Korean, and further cross-linguistic research was needed to confirm the claim. In this study, Yun's (2002) sentence level data are compared with Fowler's (1981) English data. The comparison reveals that Korean seems to be similar to English in the backwards compression effect, whereas the two languages are markedly different in the anticipatory compression effect. Thus, if English is a stress-timed language and the strong anticipatory compression effect is evidence in favour of stress-timing as is claimed, the present cross-linguistic study confirms Yun's (2002) suggestion-Korean is unlikely to be stress-timed. On the other hand, compression effects are revisited: the differences in vowel compression between English and Korean are discussed from the syntactic and phonological points of view.

  • PDF