• Title/Summary/Keyword: Compression and Recovery

Search Result 237, Processing Time 0.03 seconds

A 2MC-based Framework for Sensor Data Loss Decrease in Wireless Sensor Network Failures (무선센서네트워크 장애에서 센서 데이터 손실 감소를 위한 2MC기반 프레임워크)

  • Shin, DongHyun;Kim, Changhwa
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.2
    • /
    • pp.31-40
    • /
    • 2016
  • Wireless sensor networks have been used in many applications such as marine environment, army installation, etc. The sensor data is very important, because all these applications depend on sensor data. The possibility of communication failures becomes high since the surrounding environment of a wireless sense network has an sensitive effect on its communications. In particular, communication failures in underwater communications occur more frequently because of a narrow bandwidth, slow transmission speed, noises from the surrounding environments and so on. In cases of communication failures, the sensor data can be lost in the sensor data delivery process and these kinds of sensor data losses can make critical huge physical damages on human or environments in applications such as fire surveillance systems. For this reason, although a few of studies for storing and compressing sensor data have been proposed, there are lots of difficulties in actual realization of the studies due to none-existence of the framework using network communications. In this paper, we propose a framework for reducing loss of the sensor data and analyze its performance. The our analyzed results in non-framework application show a decreasing data recovery rate, T/t, as t time passes after a network failure, where T is a time period to fill the storage with sensor data after the network failure. Moreover, all the sensor data generated after a network failure are the errors impossible to recover. But, on the other hand, the analyzed results in framework application show 100% data recovery rate with 2~6% data error rate after data recovery.

Spinal Epidural Hematoma after Pain Control Procedure

  • Nam, Kyoung-Hyup;Choi, Chang-Hwa;Yang, Moon-Seok;Kang, Dong-Wan
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.281-284
    • /
    • 2010
  • Spinal epidural hematoma is a rare complication associated with pain control procedures such as facet block, acupuncture, epidural injection, etc. Although it is an uncommon cause of acute myelopathy, and it may require surgical evacuation. We report four patients with epidural hematoma developed after pain control procedures. Two procedures were facet joint blocks and the others were epidural blocks. Pain was the predominant initial symptom in these patients while two patients presented with post-procedural neurological deficits. Surgical evacuation of the hematoma was performed in two patients while in remaining two patients, surgery was initially recommended but not performed since symptoms were progressively improved. Three patients showed near complete recovery except for one patient who recovered with residual deficits. Although, spinal epidural hematoma is a rare condition, it can lead to serious complications like spinal cord compression. Therefore, it is important to be cautious while performing spinal pain control procedure to avoid such complications. Surgical treatment is an effective option to resolve the spinal epidural hematoma.

The Effect of Intravenous Lipo-Prostaglandin E1 Injectioin in a Rat Foraminal Stenosis Model (백서의 척추간 신경공 협착증 모델에서 Lipo-Prostaglandin E1의 정주효과)

  • Yoon, Hye Kyoung;Lee, Pyung Bok;Han, Jin Soo;Park, Sang Hyun;Lee, Seung Yoon;Lee, Yang Hyun;Kim, Yong Chul;Lee, Sang Chul
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 2007
  • Background: Lipo-prostaglandin E1 (Lipo-$PGE_1$) has vasodilating and platelet aggregation inhibitory characteristics and it has been used as a treatment for patients with blood flow dysfunction disease. Based on the mechanisms of lumbar spinal stenosis, including veno congestion, neuro-ischemia and mechanical compression, we aimed to study whether intravenous Lipo-$PGE_1$ injection has any therapeutic effect on hyperalgesia in a rat foraminal stenosis model. Methods: In this study, twenty male Sprague-Dawley rats were divided into the control (n = 10) and Lipo-$PGE_1$ (n = 10) groups. A small stainless steel rod was inserted into the L5-6 intervertebral foramen to induce intervertebral foramen stenosis and chronic DRG compression. In the Lipo-$PGE_1$ group, $0.15{\mu}g/kg$ of Lipo-$PGE_1$ were injected intravenously via a tail vein for 10 days starting from the $3^{rd}$ day after operation. Behavioral testing for mechanical and thermal hyperalgesia was performed for 3 weeks after the injections. Results: From the $10^{th}$ day after Lipo-$PGE_1$ injection, the rats in the experimental group showed significant recovery of their mechanical threshold, and this effect was maintained for 3 weeks. No significant differences of the thermal hyperalgesia were observed between the two groups. Conclusions: These findings suggest that intravenously injected Lipo-$PGE_1$ may be effective for alleviating neuropathic pain, which isthe main symptom of spinal stenosis, by improving the blood flow dysfunction.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Vaginal Reconstruction with Modified Singapore Flap in MRK Syndrome Patients (MRK증후군 환자에서 변형 Singapore피판술을 이용한 질 재건)

  • Kim, Do-Hoon;Pyon, Jai-Kyong;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap-Sung;Lim, So-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.616-620
    • /
    • 2011
  • Purpose: Mayer-Rokitansky-Kuster syndrome (MRK) is second common cause of primary amenorrhea. It is a syndrome of vaginal aplasia and Mullerian duct anomaly. Vaginal aplasia varies from agenesis of whole vagina to aplasia of upper 2/3. For reconstructing vagina, various methods are introduced. Gracilis myocutaneous flap was the first attempt in that the flap is used in vaginal reconstruction. Various flap-based vaginal reconstruction methods have been introduced. Modified Singapore flap (pedicled neurovascular pudendal thigh fasciocutaneous flap) is one of those methods that used posterior labial artery as pedicle, and pudendal nerve branch as sensory root. As its donor lies on inguinal crease that is easily hidden and there are benefits on sexual intercourse by early sensory recovery, authors think that modified Singapore flap is effective for young MRK syndrome patients. Methods: Eight patients underwent surgery between 2008 and 2010. The flap was designed on both groin area with external pudendal artery branch as a pedicle. All flaps were fixated in pelvic cavity with absorbable suture, and additional compression on neovaginal wall was supplied by polyvinyl alcohol sponge ($Merocel^{(R)}$). Results: All patients were successfully reconstructed without flap related complications such as congestion or partial flap loss. The average size of the flap (each side) was 69.34 $cm^2$. Polyvinyl alcohol sponge ($Merocel^{(R)}$) was inserted into neovagina for 5 days on every patient. One case of rectal laceration was occurred while making pelvic pocket by OBGY team. Other complications such as lumen narrowing, wound contracture or vaginal prolapsed were not reported during 8 months of follow up. Conclusion: Modified Singapore flap is a sensate fasciocutaneous flap that is thinner than other myocutaneous flap such as VRAM, and more durable over skin graft. Therefore this is a good choice for vaginal reconstruction in MRK syndrome. And known complications of Modified Singapore flap could be reduced with careful procedure and mild compression techniques.

Comparison on the Energy Consumption of the Vacuum Evaporation and Hydrated-Based Technologies for Concentrating Dissolved Ions (용존 이온 농축을 위한 진공 증발 기술과 하이드레이트 기반 기술의 소모 에너지 비교)

  • Han, Kunwoo;Rhee, Chang Houn;Ahn, Chi Kyu;Lee, Man Su
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.378-386
    • /
    • 2019
  • In the present paper we report the calculation results of operation energy consumption for dissolved ions concentration technologies using vacuum evaporation (VE) and hydrate formation. Calculations were conducted assuming the tenfold concentration of saline water (0.35 wt% NaCl solution) of 1 mol/s at room temperature and atmospheric pressure employing vacuum evaporation at $69^{\circ}C$ and 30 kPa and hydrate-based concentration using $CH_4$, $CO_2$ and $SF_6$ as guest molecules. Operation energy consumption of VE-based concentration resulted in 47 kJ/mol, whereas those of hydrate-based concentration were 43, 32, and 28 kJ/mol for $CH_4$, $CO_2$ and $SF_6$ hydrates, respectively. We observe that hydrate-based concentration can a competitive option for dissolved ions recovery from energy consumption standpoint. However, the selection of guest gas is very critical, since it accordingly determines the hydration number, the hydrate formation energy, gas compression energy, etc. The selection of guest gas, separation of concentrated brine and water phases, and the enhancement of hydrate formation rate are the key factors for the commercialization of hydrated-based technology for concentrating dissolved ions.

Preparation and Characterization of Heterogeneous Anion Exchange Membrane for Recovery of Sulfate Ion from Waste Water (폐수 중 황산이온 회수를 위한 불균질 음이온교환막의 제조 및 특성)

  • Choi, Kuk-Jong;Choi, Jae-Hwan;Hwang, Eui-Hwan;Rhee, Young-Woo;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.3
    • /
    • pp.247-254
    • /
    • 2007
  • Heterogeneous anion exchange membranes were prepared by compression molding for the recovery of sulfate ion from waste water. The swelling ratio, transport number, and ion exchange capacity of the heterogeneous anion exchange membranes were increased and their electrical resistances were decreased as the amount of ion exchange resin content in the matrix was raised. The tensile strength of the heterogeneous anion exchange membrane was decreased with increasing the amount of ion exchange resin in the LLDPE. The tensile strength for the LDPE heterogeneous membrane containing 30 wt% anion exchange resin showed the highest value. The water content increased with increasing amount of ion exchange resin in the membrane. Moreover the highest transport number of the membrane was 0.86. The electrical resistance of LDPE matrix membrane with 50 wt% resin showed $46.5{\Omega}{\cdot}cm^2$. Current efficiency of electrodialysis for sulfate ion showed the highest value at the current density of $125 mA/cm^2$ in 0.5 mol/L sulfuric acids solution.

Nondestructive detection of crack density in ultra-high performance concrete using multiple ultrasound measurements: Evidence of microstructural change

  • Seungo Baek;Bada Lee;Jeong Hoon Rhee;Yejin Kim;Hyoeun Kim;Seung Kwan Hong;Goangseup Zi;Gun Kim;Tae Sup Yun
    • Computers and Concrete
    • /
    • v.33 no.4
    • /
    • pp.399-407
    • /
    • 2024
  • This study nondestructively examined the evolution of crack density in ultra-high performance concrete (UHPC) upon cyclic loading. Uniaxial compression was repeatedly applied to the cylindrical specimens at levels corresponding to 32% and 53% of the maximum load-bearing capacity, each at a steady strain rate. At each stage, both P-wave and S-wave velocities were measured in the absence of the applied load. In particular, the continuous monitoring of P-wave velocity from the first loading prior to the second loading allowed real-time observation of the strengthening effect during loading and the recovery effect afterwards. Increasing the number of cycles resulted in the reduction of both elastic wave velocities and Young's modulus, along with a slight rise in Poisson's ratio in both tested cases. The computed crack density showed a monotonically increasing trend with repeated loading, more significant at 53% than at 32% loading. Furthermore, the spatial distribution of the crack density along the height was achieved, validating the directional dependency of microcracking development. This study demonstrated the capability of the crack density to capture the evolution of microcracks in UHPC under cyclic loading condition, as an early-stage damage indicator.

Mechanical Properties and Fabric Handle of Grafted Silk Fabrics (그라프트 가공 견직물의 力學特性과 태의 分析硏究)

  • Kim, Kyu Beom;Chin, Young Gil
    • Textile Coloration and Finishing
    • /
    • v.8 no.3
    • /
    • pp.52-58
    • /
    • 1996
  • In order to study an applicable level for the graft finish of silk filaments and the characteristics of silk fabric, some sample fabrics were woven with grafted weft and the characteristics of sample fabrics were analyzed to evaluate the mechanical properites and the handle values according to the graft yield(%) of MMA and HEMA monomers on silk filaments. 1. The tensile properties were detected in the increase of linearity(LT) and the recovery in time of the increasing resilience(RT). 2. The bending properties were detected to have a lot of effect on the balance of bending rigidity(B) to hysteresis(2HB) according to the elastic relaxation of warp tension and the interlacing stress. 3. The shearing properities were detected to show the softness and the elastics in a case of the decrease in shearing rigidity(G) and hysteresis(2HG, 2HG5) according to the graft yields. 4. The compression properties were detected in the decrease of linearity(LC) and the uniformity of resilience(RC). It explains that the tendancies of compressible variation is not accepted. 5. The surface properities were detected to be affected by the surface forms of grafted silk filaments and the variation in the morphologies of interlacing sections. Considering the interlacing eveness, MMA grafted fabrics were accepted within the level of WOMEN'S THIN DRESS(KN-201-LDY) but HEMA grafted fabrics were not accepted. 6. The variation of handles were detected in the increase of total hand(TAV) within the levels of 65% of KOSHI and 82% of HARI on the average. 7. The handle fashions were detected in the nature of Habuta and Dechine from MAA graft but the nature of Fugi were shaped from HEMA graft in proportion to the graft yields.

  • PDF

Effect of Muscle Taping and Joint Taping on Static and Dynamic Balance in Normal Adults with Chronic Ankle Instability

  • Kim, Hyun-Sung;Park, Jae-Young
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.101-108
    • /
    • 2022
  • Purpose : This study was conducted to investigate the effect of muscle taping and joint taping on static and dynamic balance in normal adults with chronic ankle instability. Methods : The subjects of this study were 32 people who met the inclusion criteria. This cross-sectional study was conducted using the Kinesio tape, an elastic tape, was used. Subjects were randomized to exclude the effect of sequence, and no taping, joint taping, and muscle taping were applied as taping interventions. One-leg standing test and a Functional reach test were conducted to measure static balance, and Y-balance test was conducted to measure dynamic balance. One way repeated ANOVA was performed to investigate the difference in balance ability according to the taping intervention. If there was a significant difference, a post-hoc was performed using the Bonferroni method. Results : In the case of static balance, joint taping showed more significant results than did no taping and muscle taping (p<.05), and muscle taping showed more significant results than did no taping (p<.05). In the case of dynamic balance, muscle taping showed significantly larger results than did no taping and joint taping (p<.05) and joint taping showed significantly larger results than did no taping (p<.05). Conclusion : This study found that mechanical stimulation of muscles and joint compression by elastic taping increased ankle stability and improved static and dynamic balance. In particular, for static balance, joint taping was more effective than muscle taping, and for dynamic balance, muscle taping was more effective than joint taping. Applying the appropriate taping method to individual subjects has the advantage of maximizing the therapeutic effect for the recovery of balance ability. Similarly, the application of various tapings to subjects with ankle instability will have a positive effect on functional improvement.