• Title/Summary/Keyword: Compression and Recovery

Search Result 239, Processing Time 0.025 seconds

Clinical Study on a Case of Axonotmesis of Common Peroneal Mononeuropathy by using 3 times EMG Studies (근전도로 3회 추적관찰한 총비골신경마비 축색단열증에 대한 한방치험 1례)

  • Cho, Seong-Gyu;Chung, Byung-Shik;Yun, Hyung-Seok;Lee, Joo-Hyung;Lee, Sang-Hoon;Seo, Dong-Min;Lee, Jae-Dong
    • Journal of Pharmacopuncture
    • /
    • v.4 no.2
    • /
    • pp.105-112
    • /
    • 2001
  • In Oriental Medicine, mononeuropathy belongs to or . Common peroneal neuropathy(CPN) is the most frequently encountered mononeuropathy in the lower extremity. It is usually caused by direct surgery injury, compression, leg crossing, trauma, traction etc, occasionally by nerve tumor. A 47-year-old healthy man was complained of the sudden development of left foot drop and sensory manifestation owing to suspected compression and habitual leg-crossing. Acupuncture along with bee-venom acupuncture, moxibustion was performed mainly at Stomach and Gallbladder Meridian specially ST36, ST37, ST40, GB34 and GB39. Nerve conduction study and electromyography was also performed three times. Symtoms was relieved fast, and full recovery took about 110 days. Acupuncture and bee-venom acupuncture are considered to be beneficial to CPN. More clinical trials and studies are needed.

An Analysis of the Application Technology of Heat Recovery System from Dyeing Wastewater (염색폐수 열회시스템 적용기술 분석)

  • 장기창;박성룡;이상남;라호상;박준택;함성원;박영태
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • A great deal of energy is necessary with emission of lots of wastewater in dyeing and finishing process, but heat recovery from wastewater is not introduced since is technology is not developed yet. In order to obtain the method utilizing hot water produced by heat source, that is, dyeing wastewater it was investigated the characteristics of dyeing and finishing process and energy basic unit. Energy basic unit of polyester/cotton (T/C), polyester/rayon (T/R) and polyester dyeing process are higher than that of the other process. The average quantity of wastewater for each dyeing company is 20,470 ton/month, the average temperature of wastewater is about 41$^{\circ}C$. Because the SS solution of wastewater in polyester dyeing process is lower than that of the other process, the effect of corrosion in heat recovery system is low. Since the energy price for 1000 kcal produced by vapor compression heat pump is presumed to be 22.50 won, it is found to be very economic heat recovery system, and its payback is 2.09 years for the factory with LNG boiler.

  • PDF

Mechanical Properties of Monodisperse Polymer Particles and Electroless Ni Plated Monodisperse Polymer Particles (단분산 가교고분자 미립자 및 그의 무전해 니켈도금체의 기계적 물성 연구)

  • Kim Dong-Ok;Jin Jeong-Hee;Shon Won-IL;Oh Seok-Heon
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.332-337
    • /
    • 2006
  • Monodisperse polymer particles were prepared via one-step seeded polymerization using PMMA seed particles and HDDA (or EGDMA) as crosslinking monomer. For the study, the effects of 1) the ratio of the absorbed monomer or monomer mixture to the seed polymer particles (swelling ratio), 2) the ratio of EGDMA in absorbed monomer mixture, 3) the dosage of initiator, and 4) electro less Ni plating on the variation of mechanical properties of monodisperse polymer particles, such as recovery rate, K-values, breaking strength and breaking displacement, were investigated by using MCT (micro compression test). It was observed that monomer swelling ratio influenced only breaking strength, but EGDMA ratio in monomer mixture, dosage of initiator and electroless Ni plating affected both K-values and breaking strength.

Incidence of Venous Thromboembolic Complications in Instrumental Spinal Surgeries with Preoperative Chemoprophylaxis

  • Hamidi, Saeed;Riazi, Mahdieh
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.114-118
    • /
    • 2015
  • Objective : Venous thromboembolism (VTE) after spinal surgery affects a patients' postoperative recovery and also carries a mortality risk. Some studies recommended chemical prophylaxis for high-risk patients and for those after complex spinal surgeries. However, chemoprophylaxis for VTE in spinal surgery is underemployed and there is no agreement on the use of VTE prophylaxis in spinal surgery. The aim of this study was to document the incidence of VTE after an elective instrumental spinal surgery, among those receiving preoperative chemoprophylaxis as compared with patients who did not receive it. Methods : This study was carried out on eighty-nine patients allocated randomly to receive either low molecular weight heparin (LMWH) or no prophylaxis before elective instrumental spinal surgery. All patients received postoperative compression stockings. A compression Doppler ultrasonography was performed for all patients to detect postoperative deep vein thrombosis. In addition, further imaging studies were performed for patients suspected of VTE. Results : Three (3.3%) patients were diagnosed with VTE. One of them had received preoperative chemoprophylaxis. There were no significant difference in incidence of VTE between the two groups (p>0.95; 95% confidence interval, 0.06-8.7). Laterality of gender and postsurgical recumbence duration were all independent predictors of VTE (p=0.01 and p<0.001, respectively). Conclusion : The difference in the incidence of thromboembolic complications between the two groups was not significant. Moreover, we found that preoperative prophylactic LMWH injection has no major bleeding complications altering postoperative course; still, the issue concerning the initiation time of chemoprophylaxis in spinal surgery remains unclear.

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

Evaluation of the Combination of Methylprednisolone and Tranilast after Spinal Cord Injury in Rat Models

  • Mbori, Ngwayi James Reeves;Chuan, Xie Yun;Feng, Qiao Xiao;Alizada, Mujahid;Zhan, Jing
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.334-340
    • /
    • 2016
  • Objective : The aim of our study was to evaluate the neuroprotective functions of the combination therapy using methylprednisolone (MP) and tranilast (TR) after spinal cord injury (SCI) in adult rats. Methods : Spinal cord compression injury model was achieved using Yasargil aneurysm clip. Rats were divided into control group, MP group, TR group, and combination therapy group using TR and MP. Rat models were assessed for locomotor functional recovery using Basso, Beattie, and Bresnahan (BBB) score, spinal cord water content and myeloperoxidase (MPO) activity 24 hours post SCI, haematoxylin and eosin staining and glial fibrillary acid protein (GFAP) staining at 7 and 14 days post SCI. Results : The spinal cord water content and MPO activity in the combination therapy group was significantly lower than the control group and the individual therapy groups p<0.05. The combination therapy group had significantly higher BBB scores than control group and individual therapy groups (p<0.05). At one week after SCI, GFAP expression in the combination group was significantly lower than the control group (p<0.05) but there was no significant difference compared to the individual therapy groups (p>0.05). At 2 weeks after SCI there was a slight decrease in GFAP expression compared to the first week but the difference was not statistically significant (p>0.05), GFAP expression between the groups was not statistically significant p>0.05. Conclusion : Combining MP and TR is therapeutically more effective in improving functional recovery, inhibiting inflammation and glial scar formation after acute SCI.

Comparison of Performance on Hypersonic Intakes in Off-Design Conditions Through Numerical Simulations (전산해석을 통한 탈설계점에서의 극초음속 흡입구 성능 비교)

  • Cha, Seung-Won;Roh, Tae-Seong;Lee, Hyoung Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.3
    • /
    • pp.195-203
    • /
    • 2019
  • Since the hypersonic intake is directly related to the overall performance of the engine, it is essential to analyze performance characteristics under various off-design conditions. In this paper, Busemann intake and conical intake with external compression were designed, and numerical simulations were performed at on/off-design conditions. Based on the results, the overall performance characteristics of two types of intake were analyzed in various Mach numbers and angle of attacks. The results showed that performance degradation of Busemann intake with truncation angle of 2 degrees was minimal. Also, the performance of Busemann intake was higher than external compression intake at various Mach numbers, however, the starting characteristics were significantly reduced with an angle of attack.

Image Restoration for Edge Preserving in Mixed Noise Environment (복합잡음 환경에서 에지 보존을 위한 영상복원)

  • Long, Xu;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.727-734
    • /
    • 2014
  • Digital processing technologies are being studied in various areas of image compression, recognition and recovery. However, image deterioration still occurs due to the noises in the process of image acquisition, storage and transmission. Generally in the typical noises which are included in the images, there are Gaussian noise and the mixed noise where the Gaussian noise and impulse noise are overlapped and in order to remove these noises, various researches are being executed. In order to preserve the edge and effectively remove mixed noises, image recovery filter algorithm was suggested in this study which sets and processes the adaptive weight using the median values and average values after noise judgment. Additionally, existing methods were compared through simulations and PSNR(peak signal to noise ratio) was used as a judgment standard.

Load and Deflection Recovery Capacities of PSC Girder with Unbonded PS H-Type Steel

  • Kim, Jong Wook;Kim, Jang-Ho Jay;Kim, Tae-Kyun;Lee, Tae Hee;Yang, Dal Hun
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1336-1349
    • /
    • 2018
  • Generally, a precast prestressed concrete (PSC) beam is used as girders for short-to-medium span (less than 30 m) bridges due to the advantages of simple design and construction, reduction of construction budget, maintenance convenience. In order to increase the span length beyond 50 m of precast PSC girder, PSC hollow box girder with unbonded prestressed H-type steel beam placed at the compressive region is proposed. The unbonded compressive prestressing in the H-type steel beams in the girder is made to recover plastic deflection of PSC girder when the pre-stressing is released. Also, the H-steel beams allow minimization of depth-to-length ratio of the girder by reducing the compressive region of the cross-section, thereby reducing the weight of the girder. A quasi-static 3-point bending test with 4 different loading steps is performed to verify safety and plastic deflection recovery of the girder. The experimental results showed that the maximum applied load exceeded the maximum design load and most of the plastic deflection was recovered when the compressive prestressing of H-type steel beams is released. Also using prestressed H-type steel as compression reinforcements in the upper part of cross section, repair and restoration difficulty and cost of PSC girders should be significantly reduced. The study result and analysis are discussed in detail in the paper.

Error Detection and Concealment of Transmission Error Using Watermark (워터마크를 이용한 전송 채널 에러의 검출 및 은닉)

  • 박운기;전병우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.262-271
    • /
    • 2004
  • There are channel errors when video data are transmitted between encoder and decoder. These channel errors would make decoded image incorrect, so it is very important to detect and recover channel errors. This paper proposes a method of error detection and recovery by hiding specific information into video bitstream using fragile watermark and checking it later. The proposed method requires no additional bits into compressed bitstream since it embeds a user-specific data pattern in the least significant bits of LEVELs in VLC codewords. The decoder can extract the information to check whether the received bitstream has an error or not. We also propose to use this method to embed essential data such as motion vectors that can be used for error recovery. The proposed method can detect corrupted MBs that usually escape the conventional syntax-based error detection scheme. This proposed method is quite simple and of low complexity. So the method can be applied to multimedia communication system in low bitrate wireless channel.