• 제목/요약/키워드: Compliance testing

Search Result 121, Processing Time 0.03 seconds

A Study on the Apparent Negative Crack Growth Phenomenon of J-R Curve(II) (J-R 곡선에서의 균열길이 감소현상에 관한 연구 (II))

  • 석창성;최용식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1627-1631
    • /
    • 1992
  • It often occurs in J-R testing that some initial crack extension (.DELTA.a) data points have anomalous negative values. The reason for the apparent negative crack growth is due to the analysis method. The phenomenon as a possible source of error in determining $J_{IC}$ or J-R curve from partial unloading compliance experiments may be eliminated by the compliance correction equation or the offset technique. In this study, the correction methods are suggested and examined by the measurement of the actual crack length and $J_{JC}$ analysis.

A Study for the Fatigue Crack Growth Behavior of Concrete (콘크리트의 피로균열 성장거동에 관한 연구)

  • 김진근;김윤용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.101-107
    • /
    • 1996
  • In this study, the wedge splitting test (WST) specimens with various strength levels were tested to investigate the fatigue crack growth behavior of concrete. Selected test variables were concrete compressive strength with 2 levels (28 MPa, 60 MPa, 100 MPa) and maximum fatigue loading with 2 levels (75%, 85%). Fatigue testing was preceded by fracture energy test and the crack growth was measured by means of the compliance calibration method, 60 WST specimens were cast for the fatigue test, and 6 companion cylinders ($\phi$100${\times}$ 200 mm) for each batch. In fatigue test, the frequency of loading cycle was 1 Hz, and the minimum fatigue loading level was 5~10 % of ultimate monotonic loading. On the basis of the experimental results, a fracture mechanics-based empirical relationships for fatigue crack growth rate (da/dN-$\Delta$KI relationships) were presented. In addition, the effect of initial notch depth on the fracture energy and the validity of compliance calibration technique for the WST were shown.

  • PDF

Design and Implementation of Paddle Type End of Arm Tool for Rescue Robot (인명 구조용 로봇의 패들형 말단 장치 설계 및 구현)

  • Kim, Hyeonjung;Lee, Ikho;An, Jinung
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.4
    • /
    • pp.205-212
    • /
    • 2018
  • This paper deals with the paddle type end of arm tool for rescue robot instead of rescue worker in dangerous environments such as fire, earthquake, national disaster and defense. It is equipped at the dual arm manipulator of the rescue robot to safely lift up an injured person. It consists of the paddle for lifting person, sensors for detecting insertion of person onto the paddle, sensor for measuring the tilting angle of the paddle, and mechanical compliance part for preventing incidental injuries. The electronics is comprised of the DAQ module to acquire the sensors data, the control module to treat the sensors data and to manage the errors, and the communication module to transmit the sensors data. After optimally designing the mechanical and electronical parts, we successfully made the paddle type end of arm tool and evaluated its performance by using specially designed jigs. The developed paddle type end of arm tool is going to be applied to the rescue robot for performance verification through field testing.

Offline Shopping During the COVID-19 Pandemic: Between Need and Fear

  • USMAN, Hardius;PROJO, Nucke Widowati Kusumo;CHAIRY, Chairy
    • Fourth Industrial Review
    • /
    • v.2 no.2
    • /
    • pp.25-37
    • /
    • 2022
  • Purpose - The purposes of this research are: (1) Building and testing a research model that integrates Theory of Reasoned Action (TRA) with fear, perceived risk, and health protocols; (2) Examining the impact of compliance with health protocols on consumer behavior when offline shopping. Research design, data, and methodology - The data collection uses the self-administered survey method, and the questionnaire is distributed online. A total of 504 Indonesian population aged 18 years old or more participate in this research. Data are analyzed using factor analysis, multiple regression, and multiple regression with interaction. Result - This study reveals several findings: (1) Attitude and subjective norm have a significant effect on offline shopping behavior; (2) fear has a direct and indirect effect on offline shopping behavior; (3) the effect of perceived risk on the intensity of offline shopping is determined by compliance with health protocols. Conclusion - This paper discusses the direct influence of attitudes and subjective norms on behavior. This research also integrates fear, perceived risk, and health protocol factors in TRA, which may not have been done much, especially in the COVID-19 pandemic context.

A Study on Self Care Compliance Related to Infection Management for Continuous Ambulatory Peritoneal Dialysis Patients (복막투석환자의 감염예방과 관련된 자가간호 이행에 관한 연구)

  • Lee Eun-Young;Kim Jung-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 1998
  • This study was a descriptive research on the level of self-care available to continous ambulatory peritoneal dialysis patients (hereinafter referred to as 'CAPD patient') related to the specific area of infection management. The method employed for the collection of data was a modified instrument of the self-care survey essentially based on Young Sook Choi's instrument. The relevant data was collected from september 1, 1996 to september 30, 1996. The subjects were provided with an open-ended question regarding the reasons behind why they did not seek self-care. The answers provided about self-care compliance were analyzed by SPSS for frequency, percentage, mean, t-test, ANOVA. Reasons for non-compliance were analyzed by content analysis. The results of the study were as follows : 1. The percentage of patients engaging in self-care were according to the following self performed tasks : preparation of dialysis : 30.58 points Dialysate exchange procedures : 49.40 points - Two bag type : 50.50 points - Spike type : 48.80 points - Neo type : 48.90 points Catheter exit site care : 25.13 points More specifically, in relation to the preparation of dialysis as referred to above, those patients engaging in self care was relatively high with respect to the cleaning of the dialysis before use and for the preservation of peritosol. However, in dialysate exchange procedures, data revealed that those patients engaging in self-care are relatively low with respect to putting on a mask during the performance of peritosol exchange. Similary in peritosol exchange procedure and catheter exit care, low levels of self-care performance were found in the area of putting on a mask during the peritosol exchange procedures and catheter line testing procedures, respectively. 2. In general characteristics, there appeared to be no distinction in self-care compliance among CAPD patients. 3. The main reasons for non-compliance were based in the following factor : intellectual, attitude, enviromental surrounding and physical. As a result of the foregoing finding, nurses should provide adequate assistance to promote self-care compliance by CAPD patients by checking the preparation of dialysis, dialysate exchange procedure, and catheter exit site care which recieved low point in this research.

  • PDF

A lower bound analytical estimation of the fundamental lateral frequency down-shift of items subjected to sine testing

  • Nali, Pietro;Calvi, Adriano
    • Advances in aircraft and spacecraft science
    • /
    • v.7 no.1
    • /
    • pp.79-90
    • /
    • 2020
  • The dynamic coupling between shaker and test-article has been investigated by recent research through the so called Virtual Shaker Testing (VST) approach. Basically a VST model includes the mathematical models of the test-item, of the shaker body, of the seismic mass and the facility vibration control algorithm. The subsequent coupled dynamic simulation even if more complex than the classical hard-mounted sine test-prediction, is a closer representation of the reality and is expected to be more accurate. One of the most remarkable benefits of VST is the accurate quantification of the frequency down-shift (with respect to the hard-mounted value), typically affecting the first lateral resonance of heavy test-items, like medium or large size Spacecraft (S/Cs), once mounted on the shaker. In this work, starting from previous successful VST experiences, the parameters having impact on the frequency shift are identified and discussed one by one. A simplified analytical system is thus defined to propose an efficient and effective way of calculating the lower bound frequency shift through a simple equation. Such equation can be useful to correct the S/C lateral natural frequency measured during the test, in order to remove the contribution attributable to the shaker in use. The so-corrected frequency value becomes relevant when verifying the compliance of the S/C w.r.t. the frequency requirement from the Launcher Authority. Moreover, it allows to perform a consistent post-test correlation of the first lateral natural frequency of S/C FE model.

An Evaluation Model of Game Software (게임 소프트웨어의 품질 평가 모델)

  • Jung, Hye-Jung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.6
    • /
    • pp.115-125
    • /
    • 2007
  • Game software is tremendous popularity in inside and outside of the country, so it rises market value. Therefore, it is important to study for the evaluation models of game software. In a general way, I think that ISO/IEC 9126 is the international standard of the software quality testing. Especially, game software quality has been more important on users and developers, so we need the compliance testing model of the game software. In this paper, we evaluate the game software quality objectively and quantitatively, we propose the software quality metrics of testing. Also, we propose the evaluation model of game software on the basis of international standard ISO/IEC 9126, six quality characteristic point of view. That is functionality, reliability, usability, efficiency, portability, and maintainability.

  • PDF

Wind Turbine Power Performance Testing using Nacelle Transfer Function (나셀 변환 함수를 이용한 풍력터빈 출력성능평가)

  • Kim, Hyeon-Wu;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.51-58
    • /
    • 2013
  • A study on power performance testing of a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was carried out using the Nacelle Transfer Function, NTF, according to IEC 61400-12-2. The wind data for this study was measured at HanKyoung wind farm of Jeju Island. The NTF was modeled using the correlation between wind speeds from the met-mast and from the wind turbine nacelle within 2~4 rotor diameter from the met-mast. The NTF was verified by the comparison of estimated Annual Energy Productions, AEPs, and binned power curves. The Nacelle Power Curve, NPC, was derived from the nacelle wind speed data corrected by NTF. The NPC of wind turbine under test and the power curve offered by the turbine manufacturer were compared to check whether the wind turbine is properly generating electricity. Overall the NPC was in good agreement with the manufacturer's power curve. The result showed power performance testing for a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was successfully carried out in compliance with IEC 61400-12-2.

A Study on the Measuring Accuracy of Ultrasonic Hardness Tester (초음파 경도계의 측정정도에 관한 연구)

  • Han, Eung-Kyo;Yoon, Jong-Hak;Kim, Jae-Yeor
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 1987
  • In recent days, the application of ultrasonics has been increased in the field of engineering and medicine. The ultrasonic hardness tester to apply the principle of contact compliance method is entirely different from hardness tester in the past and in the practical use, the more pre- cisive measurement is required because it has a slight change of hardness value due to the difference of resonance frequency. Therefore, in this study, as one type of applicative transducers which can detect the optimum pressure load, ring type load cell was used in the measurement of ultrasonic hardness. From experimental results, it was compared ultrasonic hardness testing method with the other hardness testing methods. Also, the measurement error of ultrasonic hardness tester could be measured within .+-. 0.5 HRC F.S. in the case of 3.0Kg pressure load.

  • PDF

On OIML Mixed Acceptance Sampling Plans and Optimal Target Value for Products in Prepackages (OIML 혼합 샘플링 검사계획에 대한 고찰과 최적 목표값의 설정 : 실량표시상품을 대상으로)

  • Seo, Sun-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.1
    • /
    • pp.17-24
    • /
    • 2015
  • Mixed acceptance sampling plans for quantity of products in prepackages are widely used for compliance testing. To pass testing, random samples jointly comply with two legal requirements: (i) the average net content of an inspection lot shall be not less than the labelled quantity and (ii) the numbers of under-filled prepackages in a sample are less than or equal to permitted numbers. This paper discusses some drawbacks of the acceptance sampling plans and requirements recommended in OIML R87 (KS A 50087 translated by Korean) developed by the International Organization of Legal Metrology and evaluates the producer's and consumer's risks. In addition, problem of determining a target value in filling processes of prepackages under the OIML R87 requirements is addressed and illustrated with a numerical example.