• 제목/요약/키워드: Complex odor

검색결과 117건 처리시간 0.031초

축산농장의 악취 발생과 관리에 관한 실태조사 (A Survey on Current State of Odor Emission and Control from Livestock Operations)

  • 김두환;이인복;최동윤;송준익;전중환;하덕민
    • 한국축산시설환경학회지
    • /
    • 제19권2호
    • /
    • pp.123-132
    • /
    • 2013
  • This survey was conducted to investigate the current state of odor emission and control from 48 site of Hanwoo, dairy, swine and poultry farms in Korea. On-site complex odors assessment by the method of 6 step direct sensory evaluation and ammonia concentrations by portable gas detector on the boundary line of farms were evaluated and detected as 1.11 & 2.78 ppm, 1.67 & 2.56 ppm, 1.91 & 2.89 ppm, 1.8 & 2.4 ppm and 1.33 & 2.33 ppm, respectively. Almost of Hanwoo, dairy and poultry farms were nothing the complaints occurred for the last 2 years, however as 60% of swine farms were suffered odor complain. All of livestock operations were used the additives for improving the farm environment and spent the considerable costs for odor reduction. There were several plans almost farms, as a fortify maintenance, keep clean, tree planting, expansion facilities for manure treatment or odor reduction.

Characterization of the Bacterial Community Associated with Methane and Odor in a Pilot-Scale Landfill Biocover under Moderately Thermophilic Conditions

  • Yang, Hyoju;Jung, Hyekyeng;Oh, Kyungcheol;Jeon, Jun-Min;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권6호
    • /
    • pp.803-814
    • /
    • 2021
  • A pilot-scale biocover was constructed at a sanitary landfill and the mitigation of methane and odor compounds was compared between the summer and non-summer seasons. The average inlet methane concentrations were 22.0%, 16.3%, and 31.3%, and the outlet concentrations were 0.1%, 0.1%, and 0.2% during winter, spring, and summer, respectively. The odor removal efficiency was 98.0% during summer, compared to 96.6% and 99.6% during winter and spring, respectively. No deterioration in methane and odor removal performance was observed even when the internal temperature of the biocover increased to more than 40℃ at midday during summer. During summer, the packing material simultaneously degraded methane and dimethyl sulfide (DMS) under both moderately thermophilic (40-50℃) and mesophilic conditions (30℃). Hyphomicrobium and Brevibacillus, which can degrade methane and DMS at 40℃ and 50℃, were isolated. The diversity of the bacterial community in the biocover during summer did not decrease significantly compared to other seasons. The thermophilic environment of the biocover during summer promoted the growth of thermotolerant and thermophilic bacterial populations. In particular, the major methane-oxidizing species were Methylocaldum spp. during summer and Methylobacter spp. during the non-summer seasons. The performance of the biocover remained stable under moderately thermophilic conditions due to the replacement of the main species and the maintenance of bacterial diversity. The information obtained in this study could be used to design biological processes for methane and odor removal during summer and/or in subtropical countries.

생활폐기물 자동집하시설의 악취물질 배출특성 (Emission Characteristics of Odor Compounds from Pneumatic Waste Collection Plants)

  • 윤용경;김대근
    • 대한환경공학회지
    • /
    • 제34권8호
    • /
    • pp.541-548
    • /
    • 2012
  • 본 연구에서는 생활폐기물 자동집하시설에서의 악취물질 배출특성을 파악하고자 2개소(A시설, B시설)의 시설을 선정하여 공기관로 내의 이송가스와 최종배출가스를 대상으로 복합악취와 22종의 지정악취물질을 조사하였다. 생활폐기물 자동집하시설에서 배출되는 주된 악취물질은 암모니아, 황 화합물, 아세트알데하이드이었으며, 악취처리공정의 종류에 따라 최종배출구의 악취 배출특성이 상이하였다. 이송가스를 대상으로 한 악취기여도 평가에서는 A시설의 경우, 디메틸설파이드 26%, 아세트알데하이드 18%, 메틸머캅탄 14%의 악취기여도를 보였으며, B시설의 경우에는 메틸머캅탄 56%, 황화수소와 디메틸설파이드가 각각 15%이었다.

구미국가산업단지의 아세트알데히드 악취모델링 (Odor Modeling of acetaldehyde in Gumi National Industrial Complex)

  • 이은주;무하매드 사이드;임광희
    • Korean Chemical Engineering Research
    • /
    • 제54권1호
    • /
    • pp.22-35
    • /
    • 2016
  • 본 연구에서는 CALPUFF 모델링을 수행하여 구미국가산업단지 공단지역에 악취로 인한 주민의 민원이 빈번한 지역과 아세트알데히드 배출 주요 점오염원인 구미국가산업단지 공단지역 합성섬유제조업체 악취배출시설과의 상관관계를 정립하고자 하였다. 본 연구의 CALPUFF 모델링 결과로서 T사 배출설비 개선 후에 구미공단의 아세트알데히드 농도의 최대값이 T사 배출설비 개선 전보다 O ($10^{-5}g/m^3$)에서 O ($10^{-6}g/m^3$)으로 저감되고 겨울(1월)과 봄(4월)에 구미 1공단의 아세트알데히드 농도가 개선되어서 구미 3공단에서 자주 아세트알데히드 농도의 구미공단 내 최대값이 도출되었다. 또한 T사 배출설비 개선 후에 도출된 아세트알데히드 농도의 구미공단 내 최대값 예측범위는 T사 배출설비 개선 전의 구미공단 내 최대값 예측범위보다 개선되었다. 이와 같은 총괄 점오염원의 아세트알데히드 기여도 평가 예측을 위한 CALPUFF 모델링 최대값은 '구미대구지역 HAPs 조사연구'의 측정 최대값 결과와 비교하였을 때에 상호 비교할 수 있는 비슷한 값을 보였고 민원추세와도 잘 일치하였다. 따라서 본 연구에서 총괄 점오염원의 아세트알데히드 기여도 평가 예측에 대한 유효성을 보여주었다. 한편 총괄 점오염원에서의 아세트알데히드 배출에 의하여 확산된 아세트알데히드 농도에 대한 T사 점오염원의 상대적 기여도가 T사 배출설비 개선 후에 개선 전보다 대부분 배 이상 낮아짐이 예측되었다. 반면에 이에 대한 W사 점오염원의 상대적 기여도는 T사 배출설비 개선 후가 T사 배출설비 개선 전보다 배 이상 증가하였다. 이것은 T사 배출설비 개선에 의하여 상대적으로 W사 점오염원의 아세트알데히드 기여도가 커졌음을 의미하였다.

ISCST3을 이용한 돈사의 복합악취 영향 분석 (Impact Analysis of Complex Odor from Pigsty by Using ISCST3)

  • 권우택;홍상표;이우식
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6602-6609
    • /
    • 2013
  • 돈사에서 발생하는 악취로 인한 주변지역 영향을 EPA가 권장하는 ISCST3 모델을 적용하여 악취모델링을 실시하여 복합악취 기준과 비교하고 악취 저감대책을 수립하는데 기초자료로 활용하고자 하였다. 돈사 악취의 영향을 분석하기 위하여 자돈과 성돈에 따라서 평균치와 최소, 최대치로 분류하여 악취 농도를 예측하였다. 양돈장의 혼합 악취의 예측 결과에서 인접 건물들은 허용한계를 초과하나 양돈장으로부터 185m 떨어진 거리에 있는 피해지역에서는 허용한계를 만족하였다. 허용한계에 대한 악취 배출량을 확인하기 위해 관리동에서 누출량을 측정하였으며 누출량 50%, 30%, 10% 기준으로 악취 농도를 예측한 결과는 관리동에서 1hr 기준 최대 발생량이 10.59~52.93, 19.05~31.76, 10.59 $OU/m^3/s/m^2$로 수인한도 10.00 $OU/m^3/s/m^2$를 다소 초과하는 것으로 예측되었으나, 누출량을 10% 미만으로 관리시 수인한도를 만족할 수 있을 것으로 판단된다.

섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성 (Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants)

  • 정진호;류승한;권순덕;조윤현
    • 한국염색가공학회지
    • /
    • 제35권4호
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

국내 돈사 악취 방출량 측정 결과 분석 (Analysis of Field Measured Odor Emission Rate in Pig Houses)

  • 크리스티나;이인복;여욱현;정득영;이상연;박세준;조정화;이민형;정효혁;김다인;강솔뫼
    • 한국농공학회논문집
    • /
    • 제64권6호
    • /
    • pp.55-63
    • /
    • 2022
  • Odors emitted from pig houses have been a constant root of legal issues in pig farming. These gases are among the main causes of health and mental stresses to nearby communities, so policymakers and researchers continuously study to reduce the concentration of odorous gases from pig facilities. A continuous field experiment proved that the concentration of odor emissions inside the pig houses is highly dependent on ventilation rate, breeding details, and animal activities. However, the standard odor emission rate worldwide widely varies due to differences in pig house designs and ventilation requirements. Thus, this study aimed to measure the odor emission rates, considering the actual condition of selected Korean pig houses, through field measurement. The odor measurements were performed at three different pig production facilities without odor abatement technologies. The target experimental pig houses were buildings for weaning, growing, and fattening pigs. Results showed that the actual ventilation rate in target pig houses falls below the standard ventilation requirement of pigs, resulting in high odor concentrations inside the pig houses.

부산수영하수처리장 하수와 음식물쓰레기 병합처리 시 공정별 악취특성 및 후처리시설 효율평가 (Removal Efficiency of the Deodorization Equipment and Characteristics of Malodor during the Process in Co-treatment of Sewage and Food Waste of Su-young Wastewater Treatment Plant in Busan)

  • 이형돈;강대종;이민호;강동효;오광중
    • 청정기술
    • /
    • 제18권4호
    • /
    • pp.379-389
    • /
    • 2012
  • 우리나라는 소득증가, 도시집중화, 인구증가로 인해 환경적인 문제에 대해 점점 관심이 증대되고 있으며, 이러한 다양한 환경문제 중 악취로 인한 피해는 심각한 환경문제 중 하나이다. 부산시 수영하수처리장 내 음식물처리장은 음식물과 하수를 병합처리하는 시설로 주거지역 인근에 위치해 있어 많은 민원이 제기되고 있는 실정이다. 이에 본 연구에서는 악취물질분석과 기여도를 악취지수(odor quotient, OQ)와 총악취지수(sum of odor quotient, SOQ)를 평가하여 분석하였으며, 또한 후처리시설인 바이오필터의 효율을 평가하였다. 공기희석관능법에 의한 복합악취 측정결과, 7월과 8월에 분쇄기, 투입호퍼, 침출수 순으로 복합악취가 높은 것으로 나타났다. 기기분석법을 이용해 분석한 결과, 황화수소, 암모니아, 메틸메르캅탄, 아세트알데히드에 의한 영향이 가장 큰 것으로 나타났고, 메틸메르캅탄의 경우, 최소감지농도를 3,571배 이상 초과한 것으로 나타났다. 또한 악취기여도평가에서 메틸메르캅탄(49.95~59.08%), 황화수소(20.43~29.27%), 트리메틸아민(8.82~13.42%), 아세트알데히드(9.17~11.35%)순으로 기여도가 높은 것으로 나타났다. 다른 시설과의 기여도를 비교분석한 결과, 황화합물(메틸메르캅탄, 황화수소)의 OQ가 가장 높았으며, 분쇄기에서 SOQ가 7,067로 가장 높은 것으로 분석되었다. 또한 황화합물과 아세트알데히드, 트리메틸아민의 악취기여도가 분쇄공정에서 가장 높은 것으로 나타났다. 본 연구시설의 후처리시설에 대한 처리효율을 평가한 결과, 암모니아, 아민류는 90.00% 이상의 처리효율을 보였으나, 황화합물류의 처리효율은 평균 53.51%로 나타났다. 종합적으로 본 시설은 기타 처리시설에 비해 아세트알데히드와 트리메틸아민의 기여도가 상대적으로 높은 것으로 나타났다. 또한 음식물처리장의 후처리시설은 복합적인 악취성분 처리 시 분해효율이 감소할 수 있어 적절한 용량 및 운전조건에 대한 검토가 필요하다.

부산시 남부하수처리시설과 인근 하천에서 발생하는 악취물질 확산 특성 (Dispersion Characteristics of Odorous Elements from Nambu Wastewater Treatment Plant and a Nearby Streams in Busan)

  • 문성만;이형돈;조상원;강동효;박해식;오광중
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.953-962
    • /
    • 2011
  • The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.