• 제목/요약/키워드: Complex exposure

검색결과 455건 처리시간 0.026초

대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 - (Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals -)

  • 정종현;피영규;이준정;오인보;손병현;이형돈;윤미라;김근배;유승도;민영선;이관;임현술
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

Developmental and Neurobehavioral Effects of Mycotoxin Fumonisin B1 in Rats

  • Kwon, Oh-Seung;Ryu, Jae-Chun
    • Toxicological Research
    • /
    • 제16권2호
    • /
    • pp.117-124
    • /
    • 2000
  • The objective of this experiment is to investigate neurobehavioral and developmental effects of fumonisin B1 (FB1) after prenatal FB1 administration in rats. FB1 (0.8 or 1.6 mg/kg) was orally exposed to pregnant rats during gestational days 13 to 20, whereas the vehicle alone was administered to control group. Maternal and offspring body weights, physical landmarks of incisor eruption, eye opening, testes descending and vaginal opening, open field activity, running wheel activity, and complex maze performance were included as endpoints for developmental and neurobehavioral measurement. Maternal body weights were not signfficantly altered after FB1 exposure. Percentage of maternal weight gain difference between control and 1.6 mg/kg FBI groups was about 4%. Pre- and post-weanling weight of offsprings after prenatal exposure to FB1 was not signfficantly changed, suggesting that FB1 at 0.8 or 1.6 kg/kg doses may not cross the placenta. Significant gender difference in running wheel activity on postnatal days 57 to 63 and complex maze performance on postnatal days 75 to 78 was observed.

  • PDF

Numerical data-driven machine learning model to predict the strength reduction of fire damaged RC columns

  • HyunKyoung Kim;Hyo-Gyoung Kwak;Ju-Young Hwang
    • Computers and Concrete
    • /
    • 제32권6호
    • /
    • pp.625-637
    • /
    • 2023
  • The application of ML approaches in determining the resisting capacity of fire damaged RC columns is introduced in this paper, on the basis of analysis data driven ML modeling. Considering the characteristics of the structural behavior of fire damaged RC columns, the representative five approaches of Kernel SVM, ANN, RF, XGB and LGBM are adopted and applied. Additional partial monotonic constraints are adopted in modelling, to ensure the monotone decrease of resisting capacity in RC column with fire exposure time. Furthermore, additional suggestions are also added to mitigate the heterogeneous composition of the training data. Since the use of ML approaches will significantly reduce the computation time in determining the resisting capacity of fire damaged RC columns, which requires many complex solution procedures from the heat transfer analysis to the rigorous nonlinear analyses and their repetition with time, the introduced ML approach can more effectively be used in large complex structures with many RC members. Because of the very small amount of experimental data, the training data are analytically determined from a heat transfer analysis and a subsequent nonlinear finite element (FE) analysis, and their accuracy was previously verified through a correlation study between the numerical results and experimental data. The results obtained from the application of ML approaches show that the resisting capacity of fire damaged RC columns can effectively be predicted by ML approaches.

공단지역 토양 중 환경오염물질 농도 분포 특성 (Distribution Characteristics of Environmental Contaminant at Soil in an Industrial Complex Area)

  • 정종현;조상원;임현술
    • 청정기술
    • /
    • 제18권2호
    • /
    • pp.200-208
    • /
    • 2012
  • 본 연구는 공단지역 주민들의 환경오염물질에 의한 건강피해를 예방하기 위한 기초연구의 일환으로 수행되었다. 이를 위하여 공단지역 및 대조지역에 대한 토양 중의 환경오염물질과 다환방향족탄화수소화합물(PAHs)의 농도수준 및 분포특성을 조사하였다. 시료채취는 공단지역과 대조지역의 토양을 대상으로 실시하였으며, 토양 중의 중금속, VOCs(휘발성 유기화합물), PAHs 및 PCB(폴리클로리 네이티드비페닐) 등 토양오염물질 농도를 분석하였다. 직접노출군에 속하는 가까운 거리의 송도동, 해도동, 제철동 등은 거리가 먼 장기면에 비하여 비교적 높은 농도를 나타났다. 특히 배출원 주변의 직접노출지역(제철동)이 대조지역(장기면) 보다 오염물질의 농도가 높은 것으로 조사되었다. 토양 중의 중금속 농도는 제1지역 우려기준에 비해 대체로 낮은 것으로 나타났으나, 아연은 전 지역이 제1지역 우려기준(300 mg/kg)의 약 20.8~58.9% 수준으로 비교적 높은 농도를 나타내었다. 불소는 모든 지점에서 기준치 이하로 나타났으나, 직접노출지역인 제철동의 경우 제1지역의 우려기준(400 mg/kg)의 약 74% 수준으로 조사되어, 불소에 대한 모니터링과 배출원 관리가 필요한 것으로 판단된다. 또한, 유기인, PCB, 페놀류와 VOCs인 벤젠, 톨루엔, 에틸벤젠, 자일렌 등은 분석기기의 검출한계 이하로 나타났고, 석유계총탄화수소(TPH)의 경우에는 송도동이 높게 나타났다. 한편, 토양 중 PAHs 화합물의 농도 수준은 18.71~1744.59 ng/g이었으며, 발암가능물질 6종에 대한 PAHcarc의 농도수준은 6.54~695.94 ng/g을 나타내었다. 송도동에서 가장 높은 농도수준을 나타내어, 직접노출지역인 공업단지로부터 근거리 지점에서의 PAHs 농도가 원거리 지점인 간접노출지역보다 비교적 높은 농도를 나타내었다.

분자간 전하이동형 기능성 색소의 합성과 물성 (Syntheses and Characteristics of Intermolecular Charge-Transfer Complex Dyes)

  • Kim, Sung Hoon;Lee, Soon Nam;Lim, Yong Jin
    • 한국염색가공학회지
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 1992
  • The charge-transfer(CT) complexes derived from various donors and acceptors were evaluated as coloring matter. Dyes absorbing light in the region from the visible to the near-infrared wavelengths were synthesized. In order to determine the molar ratio of the donor to the acceptor in the CT complex in the solution, the continuous variational method was applied to each system. A 1:1 correspondence between the donor and the acceptor molecules in the CT complex in the solution is established. Color development properties in paper were examined. The longer the exposure time at constant temperature, the deeper the strength of color in paper. The strength of color at high temperature was decreased, because sublimed CT dyes in paper were migrated out side of paper.

  • PDF

바이오 멤스 및 마이크로 시스템 적용을 위한 3차원 마이크로 유로 제작 (Fabrication of 3-D microchannel for biomems and micro systems application)

  • 윤광석
    • 센서학회지
    • /
    • 제15권5호
    • /
    • pp.357-361
    • /
    • 2006
  • This paper reports a new technology to implement complex PDMS microchannels, which are simply constructed using three-dimensional photoresist structures as mold for PDMS replica process. The process utilizes LOR resist as a sacrificial layer to levitate the structural photoresist and multi-step exposure to control the thicknesses of photoresist structures. Various shapes of photoresist structures were successfully fabricated. Using the PDMS replica method, the three-dimensional photoresist structures are demonstrated to be applicable for implementing complex microchannels in PDMS. In addition, more complex multilevel microchannels are constructed by bonding two PDMS layers with just single PDMS alignment.

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.291-309
    • /
    • 1973
  • TRIGA Mark II와 III 원자로의 여러가지 가동조건에 있어서 노벽으로 부터의 누설 ${\gamma}$선에 의한 조사선양률을 3"$\times$3"원통형 NaI(T1) 섬광계수기와 400 channel파 고분석장치로 측정하였는데 측정된 spectrum으로부터 조사선양률을 산출하는데는 실제적면에서 복잡하기 짝이 없는 response matrix 방법대신 정도가 좋으면서도 비교적 그 과정이 단순한 Moriuchi의 specturm -조사선양률 환산 이론을 적용하였다. 연구결과에 따르면 노심에서 발생된 누설 ${\gamma}$선의 기본적인 spectrum 형태는 원자로의 열출력이나 차장벽에 의한 강도의 감쇠에 별로 영향을 받지 않고 있으며 원자로 누설${\gamma}$선에 의란 전조사선양률의 공기중에서의 감쇠는 폭 넓은 energy분포에도 불구하고 지수함수적 감쇠를 하고 있음이 판명되있다. 이 전조사선양률은 원자로의 열출력에 대체로 비례하고 있으나 TRIGA Mark III과 같은 가동형노심의 경우는 측정된 spectrum이 매우 다양한바, 그로부터 산출된 전조사선양률의 크기에는 관계없이, spectrum 분해방법을 적용하여 노심에서 발생된 누설 ${\gamma}$선과 원자로가동중 발생되는 여지 ${\gamma}$선의 기여를 판별 해석하는데 성공하였다.

  • PDF

Effect of Lead Exposure on the Status of Reticulocyte Count Indices among Workers from Lead Battery Manufacturing Plant

  • Kalahasthi, Ravibabu;Barman, Tapu
    • Toxicological Research
    • /
    • 제32권4호
    • /
    • pp.281-287
    • /
    • 2016
  • Earlier studies conducted on lead-exposed workers have determined the reticulocyte count (RC) (%), but the parameters of Absolute Reticulocyte Count (ARC), Reticulocyte Index (RI), and Reticulocyte Production Index (RPI) were not reported. This study assessed the effect of lead (Pb) exposure on the status of reticulocyte count indices in workers occupied in lead battery plants. The present cross-sectional study was carried out on 391 male lead battery workers. The blood lead levels (BLL) were determined by using an Atomic Absorption Spectrophotometer. The RC (%) was estimated by using the supravital staining method. The parameters, such as ARC, RI, and RPI, were calculated by using the RC (%) with the red cell indices (RBC count and hematocrit). The levels of RBC count and hematocrit were determined by using an ABX Micros ES-60 hematology analyzer. The levels of reticulocyte count indices - RC (%), ARC, RI, and RPI significantly increased with elevated BLL. The association between BLL and reticulocyte count indices was positive and significant. The results of linear multiple regression analysis showed that the reticulocyte count (${\beta}=0.212$, P < 0.001), ARC (${\beta}=0.217$, P < 0.001), RI (${\beta}=0.194$, P < 0.001), and RPI (${\beta}=0.208$, P < 0.001) were positively associated with BLL. The variable, smoking habits, showed a significant positive association with reticulocyte count indices: RC (%) (${\beta}=0.188$, P < 0.001), ARC (${\beta}=0.174$, P < 0.001), RI (${\beta}=0.200$, P < 0.001), and RPI (${\beta}=0.151$, P < 0.005). The study results revealed that lead exposure may cause reticulocytosis with an increase of reticulocyte count indices.

Analysis on an Oxidation-Reduction Reaction of Photocatalytic Plasma Complex Module

  • KIM, Young-Do;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권2호
    • /
    • pp.21-27
    • /
    • 2022
  • Purpose: This study is about photocatalytic technology and plasma oxidation-reduction technology. To the main cause of exposure to odor pollution, two deodorization techniques were applied to develop a module with higher removal efficiency and ozone reduction effect. Research design, data and methodology: A composite module was constructed by arranging two types of dry deodorization equipment (catalyst, adsorbent) in one module. This method was designed to increase the responsiveness to the components of complex odors and the environment. standard, unity, two types of oxidizing photo-catalyst technology and plasma dry deodorization device installed in one module to increase the potential by reduction to 76% of ozone, 100%, and 82%. Results: The complex odor disposal efficiency was 92%. Ammonia was processed with 50% hydrogen sulfide and 100% hydrogen sulfide, and ozone was 0.01ppm, achieving a target value of 0.07ppm or less. The combined odor showed a disposal efficiency of 93%, ammonia was 82% and hydrogen sulfide was 100% processed, and ozone achieved a target value of 0.07 ppm or less. Conclusions: Ozone removal efficiency was 76% by increasing Oxidation-Reduction Reaction(ORR). The H2S removal efficiency of the deodorizer was higher than that of the biofilter system currently used in sewage disposal plants.

치과기공실(齒科技工室)의 작업공정별(作業工程別) 소음(騷音)에 관한 연구(硏究) (A Study on the Noise by working Process in Dental Laboratory)

  • 남상용
    • 대한치과기공학회지
    • /
    • 제15권1호
    • /
    • pp.27-41
    • /
    • 1993
  • Degree of noise by personal dental laboratory working process and degree of noise by complex dental laboratory working process were measured separtely. The time of exposure to noise greater than 70dB was analyzed. Then, the whole degree of noise in dental laboratory was estimated on the basis of afore-mentioned information. Questionaire were employed to investigate the mental, emotional and physiological effects of noise in dental technicians, The purpose of this study was to provide basic information on keeping dental techneicans who are exposed to noise pollution in good working condition and good health. Results obtained are as follows ; 1. Polishing process in each working part showed high degree of noise greater than 70dB in terms of degree of noise by personal working. 2. Degree of noise by complex working process in each working part was greater than that of personal working process. 3. Time of exposure to noise complex working process the part of porcelain 150min, partial denture 120 min, crown and bridge 100 min, full denture 80 min. 4. Degree of noise by time in dental laboratory was 80dB in general for polishing process and below 75dB for waxing process. 5. Effects of noise on mental and emotional state of dental technicians showed that they felt irritated every day(14%), irritated once in a while(29%) and easily ger mad(19%). 6. Effects of noise on heart and stomach were hyper-gastric acid(38%), gastric ulcer(11%), gastritis(5%), deuodenal ulcer(3%) and weak heart function(32%). 7. Effects of noise in the hearing ability were weak(39%), moderate(33%) and normal(14%) Data presented in this study demonstrated that noise in the dental laboratory exerts profound effect on dental technicians mentally, physiologically and emotionally, in light of the above results, therefore, it appears advisable to devots substantial on the management of working condition and put further(continuing) efforts in the investigation for reducing noise problem.

  • PDF