• Title/Summary/Keyword: Complex environment

Search Result 3,712, Processing Time 0.034 seconds

An Analysis of Wind Field According to the Prevailing Wind Directions for Understanding of Ventilation Passages in an Apartment Complex (아파트단지 환기경로 파악을 위한 주풍향별 바람장 분석)

  • Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.467-477
    • /
    • 2007
  • A numerical study with Envi-met model is experimented to investigate the characteristics of wind pattern in apartment complex. In all case, most conditions such as wind speed, temperature, and surface features are considered as the same, but wind direction is the only different factor. The wind directions considered in this study have a meaning of prevailing wind direction. When the prevailing wind with the direction of $170^{\circ}$ blows into the complex, the ventilation passage toward the outside of complex is formed and the stagnation of air is not expressed. In case of having the direction of $300^{\circ}$, most evident ventilation passages are composed. When the inflow wind direction is the northeast, $30^{\circ}$, there is some possibility of stagnation phenomenon. This is because the arrangement of buildings makes a right angle with the inflow wind direction.

A Study on Planning Guideline of Complex Housing in the Residence Inner Area - Case Study of Inner Area in Iksan City - (도심주거지의 주상복합주택 계획지침에 관한 연구 - 익산시 구도심을 사례로 -)

  • Kim, Young-Seok;Park, Pyung-Youl
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.173-179
    • /
    • 2003
  • This study analyzes the problems, which the residential inner area has, and proposes systematic and gradual progressing improvement plan for the residential environment in the inner area. Also, planning instruction is proposed through the case study of parcel·jointed complex housing. This study can be concluded as below: (1) Improvement plans sub-divided into promoting districts and inducing districts of the residential inner area are proposed. (2) Necessity for construction of streets is proposed in order to compensate existing problems in sites. (3) Necessity of complex housings is proposed fur roadsides of household unit or small-sized annexation of parcel. (4) Collecting design examples and existing literatures, the planning guideline for jointed parcel complex housing is proposed based on the established relation with a whole surface of streets, formation and distribution of purposes and increased role of exterior space.

  • PDF

The Concentrations of Sulfur Compounds and Sensation of Odor in the Residential Area Around Banwol-Sihwa Industrial Complex (반월.시화공단 주변 주거지역의 악취현황 및 황화합물의 체감도)

  • Kim, Jong-Bo;Jeong, Sang-Jin;Song, Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.147-157
    • /
    • 2007
  • This study was carried out to investigate the characteristics of fourteen odor compounds from a total of 10 sampling sites in residential areas around Banwol-Sihwa industrial complex. The measurement data are analyzed and compared with sensation of odor unit. Only a hydrogen sulfide out of four sulfur compounds was quantified above the detection limit (0.06 ppb) in the residential area around Banwol industrial complex with leather companies and a sewage treatment plant. The concentrations of VOCs were higher than those measured from a big city, and styrene showed the relatively high concentration from all sampling sites ($2.1{\sim}37.8\;ppb$). In the case of carbonyl compounds, acetaldehyde was found most frequently with the mean of 3.97 ppb, and its concentration difference was not significant between Banwol and Sihwa industrial complex. Of the nitrogen compounds, ammonia was measured at the relatively high concentration from all the sampling sites ($12{\sim}707\;ppb$), and a trimethylamine was found at the odor threshold level (0.1 ppb). The concentrations of styrene and ammonia showed relatively seasonal variation, the concentration of styrene in summer was five times higher than that in autumn, the concentration of ammonia in autumn was two times higher than that in summer. However other odorous compounds did not show such strong seasonal variation. Odor-concentration relationship between odor unit and $H_{2}S$ concentrations from industrial sources was examined and used as odor sensation evaluation, and thus the neighbourhood odor complaints maybe caused during the four seasons from the results.

Characteristics of Ozone Advection in Vertical Observation Analysis Around Complex Coastal Area (연직관측자료를 통한 복잡 연안지역의 오존 이류특성)

  • Lee, Hwa-Woon;Park, Soon-Young;Lee, Soon-Hwan;Leem, Heon-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.57-74
    • /
    • 2009
  • In order to clarify the vertical ozone distribution in planetary boundary layer of coastal area with complex terrain, an observation campaign was carried out around Gwangyang Bay with dense pollutant emission sources during two days from June, 4 2007. For this observation are Radiosonde, SODAR(SOnic Detection And Ranging) and Tethered ozone sonde were employed. The surface meteorological and photochemical observation data provided by AWS (Automatic Weather System) and AQMS (Air Quality Monitoring System) were also applied for analysis. Synoptic condition is strongly associated with lower level ozone distribution in complex terrain coastal area. Since mesoscale circulation induced by difference of characteristics of land and sea and orographic forcing is predominant under calm synoptic condition, vertical distribution of ozone is complicate and vertical ozone concentration greatly fluctuated. However in second day when synoptic influence become strong, ozone concentration in lower levels is vertically uniform regardless of observation level. This results in vertical observation indicates that vertical ozone distribution is often determined by synoptic condition and also affects surface ozone concentration.

Review on Air Quality Modeling in Environmental Impact Assessments (환경영향평가시 대기확산모델의 사용현황과 개선방안)

  • 김석철;이영수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.827-841
    • /
    • 1999
  • The air quality simulation models in wide use for air quality impact assessmetns are reviewed. After an intensive survey and comparative study upon the environmental impact assessment reports submitted to Ministry of Environment during 1990~1998, we could identify the major common problems with the air quality impact assessment procedures. Several remedies are presented here, including use of the screening models applicable to the complex terrain.

  • PDF

Devlopment HLA DEVS-Obj-C Environment for Distributed Simulation (분산 시뮬레이션을 위한 HLA DEVS-Obj-C 환경 구축)

  • 최두진;조대호
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2002.11a
    • /
    • pp.85-89
    • /
    • 2002
  • Development of distributed simulation environment must be required in order to simulate the distributed models regionally and inter-operate with running simulations individually, Simulation based on DEVS formalism is difficult to simulate the distributed models. DEVS formalism is modeling methodology. To specify model, this formalism separates behavior and structure, therefore it is able to design complex model easily. HLA is standard framework of distribute simulation environment, It is defined to facilitate the interoperability and the reusability. RTI (Run Time Infrastructure) is software that provides common service to simulation systems and implementation of the HLA Interface Specification. Method of implementation is that modules cooperating with RTI are added to simulator on DEVS simulation environment. On the DEVS simulation environment (DEVS-Obj -C) that already developed, Highest class of abstract simulator uses service that RTI provide, then This environment is able to change DEVS model into Federate and run distribute simulation that inter-operates with the RTI. Because this distributed simulation environment includes convenience of modeling that obtains through the DEVS formalism and accompanies HLA standard, this environment make it possible to simulate with_ complex systems and heterogeneous simulations

  • PDF

Interpretation of Contaminated Soil by Complex Oil (토양 내 복합유종에 의한 오염 해석 연구)

  • Lim, Young-Kwan;Kim, Jeong-Min;Kim, Jong-Ryeol;Ha, Jong-Han
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.1
    • /
    • pp.13-17
    • /
    • 2017
  • Over 30% of domestic soil contamination has occurred via petroleum products and complex oil. Moreover, contamination by complex oil is more intense than it is by a single petroleum product species. In this study, we analyzed sectional TPH (total petroleum hydrocarbon) pattern and sectional ratio of current domestically distributed petroleum products, such as kerosene, diesel, bunker C, and lubricant and complex oils, to determine pollution characteristics of the soil. In the TPH pattern, kerosene, which is a light distillate, had an early retention time, and lubricant oil, which is a heavy distillate, had a late retention time in the gas chromatogram. In addition, we obtained a complexly contaminated soil via diesel and lubricant oil from the Navy and inspected it for its ratio of complex oil species. The inspection results showed that this soil was contaminated with 85% diesel and 15% lubricant oil. The method developed in this study could be used to determine complex petroleum sources and ratios at sites with accidentally contaminated soil.

Comparison of Complex Terrain Dispersion Models (복잡지형의 대기확산모델 비교)

  • 김영성;오현선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.2
    • /
    • pp.81-94
    • /
    • 1998
  • Six complex terrain dispersion models recommended by the U. S. Environmental Protection Agency were investigated using a hypothetical case in which a plume approaches complex terrain. The six models considered were Valley, CTSCREEN, COMPLEX 1, SHORTZ, RTDM, and CTDMPLUS, the latter four being closely studied. Highest concentrations were predicted for 48 receptors and plume behaviors were compared for stable and unstable meteorological conditions. Under stable conditions, ground-level concentrations were determined by the height of the plume centerline above the terrain. The concentrations estimated by SHORTZ and COMPLEX I were higher than those estimated by CTSCREEN, with CTDMPLUS predicting the lowest concentrations. In particular, the height of the lift midpoint, as well as the co.nterline of the plume, are important in the model calculation of CTDMPLUS. Under unstable conditions, the vertical dispersion plays a key role in determining ground -level concentrations. For this case, concentrations predicted by CTDMPLUS were the 'highest, whereas those predicted by SHORTZ were the lowest. Concentration distributions predicted by CTDMPLUS are quite similar to typical Gaussian distributions even on complex terrain, except for a slight shift of the plume centerline due to the of(tract of the geostrophic wind. In addition,24-hour average concentrations were estimated for comparison with results from the Valley model. Among the four models studied closely, CTDMPLUS predicted the lowest 24-hour average concentrations, but the concentrations estimated by Valley were lower than those estimated by CTDMPLUS.

  • PDF

Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City (대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가)

  • Lee, Myeong-Sug;Keum, Jong-Lok;Kang, Dong-Hoon;Jo, Hang-Wook;Kwon, Byoung-Youne;Kim, Eun-Deok;Lee, Chan-Hyung;Song, Hee-Bong;Shin, Sang-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

Trends of Volitile Organic Compounds in the Ambient Air of Yeosu Industrial Complex (여수산단 대기 중 휘발성유기화합물질 농도 경향)

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.663-677
    • /
    • 2003
  • The concentrations of volatile organic compounds (VOCs) in the ambient air were measured at three sites (Samil-dong, SRO and EFMC) in Yeosu industrial complex during September 2000 to August 2001. Air samples were collected for 24 hours in Silicocan canister (6l) with constant flow samplers every 6 days and analyzed using a cryogenic preconcentration system and a GC/MS. At each site, we identified 35 species known as on both the carcinogenic and mutagenicity by the EPA US (TO-14 manual). No relationship was found between YOCs concentration at three sampling points. Furthermore, the result shows that there appears to be a variety distribution of the concentration. BTX, vinyl chloride and high concentrations of 1,2-dichloroethane were observed at the sampling sites. Especially, high concentration of toxic VOCs, such as vinyl chloride, chloroform, 1,2-dichloroethane and benzene were shown at environmental facilities management cooperation (EMFC) site. They seem to be emitted from the facility of wastewater treatment in Yeosu industrial complex. It was difficult to tell the seasonal variation of total VOCs concentration. Nevertheless, the concentration in winter was typically higher than in summer The concentrations of toxic VOCs contents in Yeosu industrial complex were generally lower than those in Ulsan complex, although those were similar or less than in Seoul and Daegu. Whereas, toluene and styrene emitted from Yeosu industrial complex were higher than those of Edmonton industrial complex in Canada. Especially, toluene was third times higher than those observed from Texas, USA.