• Title/Summary/Keyword: Complete occlusion

Search Result 277, Processing Time 0.03 seconds

A simplified chair-side remount technique using customized mounting platforms

  • Chauhan, Mamta Devendrakumar;Dange, Shankar Pandharinath;Khalikar, Arun Narayan;Vaidya, Smita Padmakar
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.170-173
    • /
    • 2012
  • Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms.

Clinical Usefulness of Denture Adhesives (의치접착제의 임상적 효용성)

  • Lee, Jin-Han;Lim, Young-Jun;Lee, Seok-Hyung;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.163-169
    • /
    • 2012
  • Denture adhesive is the material using for enhancing retention and function of the denture. For a long time, denture adhesive was regarded as a repulsive material for dentist. However, it seems that the needs for using this is increasing. This study was planned to recognize the denture adhesive about kinds, components, and action mechanisms through literature review, and also evaluate its clinical effects and implications.

Upper Airway Studies in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡증 환자의 상기도 검사법)

  • Kim, Jung-Soo;Lee, Kyu-Yup
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.5-9
    • /
    • 2004
  • Obstructive sleep apnea (OSA) is a common disorder characterized by recurrent cessation of breathing due to complete or partial upper airway occlusion during sleep. The incompetent tone of palatal, pharngeal, and glossal muscles which fail to maintain airway patency during sleep causes narrowing of the airway dimension and increased resistance of breathing. The identification of the sites of upper airway obstruction in patients with OSA is important in understanding the pathogenesis and deciding the treatment modality of snoring and/or OSA. Various upper airway imaging modalities have been used to assess upper airway size and precise localization of the sites of upper airway obstruction during sleep. Dynamic imaging modalities enabled assessment of dimensional changes in the upper airway during respiration and sleep. This article focused on reviews of various upper airway imaging modalities, especially dynamic upper airway imaging studies providing important information on the pathogenesis of OSA.

  • PDF

Acute left main coronary artery thrombosis as an initial presentation of systemic lupus erythematosus

  • Choi, Kang Un;Kim, Ung
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.227-231
    • /
    • 2018
  • Left main coronary artery (LMCA) thrombosis is rare and the cause should be determined. A previously healthy young man presented with severe chest pain and dyspnea. The electrocardiogram showed typical ST-segment elevation myocardial infarction with clinical instability. Emergency coronary angiography revealed complete LMCA occlusion by thrombosis. After reperfusion, the patient was admitted to the cardiac care unit. He was diagnosed with hemolytic anemia and tested positive for antinuclear antibodies. Systemic lupus erythematosus (SLE) and LMCA disease due to systemic thrombosis were diagnosed. Steroids were started and the patient was discharged without complications. We report this rare case of LMCA thrombosis as an initial presentation of SLE.

Coronary Artery Disease Reporting and Data System: A Comprehensive Review

  • Parveen Kumar;Mona Bhatia
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.1
    • /
    • pp.1-24
    • /
    • 2022
  • The Coronary Artery Disease Reporting and Data System (CAD-RADS) is a standardized reporting method for coronary computed tomography angiography (CCTA). It summarizes the findings of CCTA in 6 categories ranging from CAD-RADS 0 (complete absence of coronary artery disease) to CAD-RADS 5 (total occlusion of at least one vessel). It is applied on per patient basis for the highest grade of the stenotic lesion. The CAD-RADS also provides categoryspecific treatment recommendations, helping patient management. The main objectives of the CAD-RADS are to improve the consistency in reporting, facilitate the communication between interpreting and referring clinicians, recommend the best course of patient management, and produce consistent data for quality improvement, research and education. However, CAD-RADS has many limitations, resulting into the misclassification of the observed findings, misinterpretation of the final category, and misguidance for the treatment based upon the single score. In this review, the authors discuss the CAD-RADS categories and modifiers, along with the strengths and limitations of this new classification system.

Circulation remodeling after flow diversion of an anterior communicating artery aneurysm: A case report

  • James Withers;Robert W. Regenhardt;Adam A. Dmytriw;Justin E. Vranic;Rudolph Marciano;James D. Rabinov
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.3
    • /
    • pp.311-315
    • /
    • 2023
  • Anterior communicating artery aneurysms are the most common intracranial aneurysm and have a high risk of rupture which can lead to morbidity and mortality. Traditionally, intracranial aneurysms were treated by clipping with neurosurgical access. However, certain patients may prefer less invasive approaches or not represent open surgical candidates. Flow diverters, including flow-redirection endoluminal devices (FRED), are new-generation stents that are placed endovascularly by transfemoral or transradial access. Recent studies have demonstrated that FRED is both safe and effective, with complete occlusion of aneurysms in over 90% of patients. This case highlights an interesting phenomenon of post-flow diversion circulatory remodeling, where flow diverter treatment can alter the circle of Willis anatomy and physiology.

Retreatment of a recurrent giant aneurysm of the internal carotid artery after treatment with a flow-diverting stent

  • Ginam Kim;Junhyung Kim;Sang Kyu Park;Joonho Chung
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.208-213
    • /
    • 2023
  • Flow-diverting stents (FDSs) have proven advantageous for the treatment of large, fusiform, and dissecting aneurysms that are otherwise difficult to treat. Retreatment strategies for recurrent large or giant aneurysms after FDSs are limited to overlapping implantation of an additional FDS or definitive occlusion of the parent vessel. We report a recurrent giant aneurysm that was initially treated with an FDS with coils and was successfully treated with an additional FDS. Visual symptoms due to the mass effect of the recurrent aneurysm were completely resolved, and follow-up digital subtraction angiography revealed complete obliteration of the aneurysm. Additional FDS implantation for the retreatment of incompletely occluded aneurysms after the initial FDS treatment may be feasible and safe. Further studies are required to validate these results.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Complementary Management of Residual Intracranial Aneurysms after Endovascular or Surgical Treatment

  • Shin, Byoung-Gook;Kim, Jong-Soo;Hong, Seung-Chyul;Roh, Hong-Gee
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.179-186
    • /
    • 2005
  • Objective: The purpose of this paper is to report our experiences in managing seventeen cases of residual intracranial aneurysms following surgical or endovascular treatment and discuss the incidence of residual aneurysms, the indications and technique of retreatment of residual aneurysms. Methods: During a period of 42 months, we treated 391 aneurysms in 339 patients with microsurgical clipping or GDC embolization as a primary treatment. In 39 of them, follow-up angiography revealed residual aneurysms and seventeen of whom were retreated. There were eleven cases in ACoA, three cases in distal ICA, one, in each of MCA, ACA and basilar artery. We reviewed retrospectively the clinical notes, operation records and cerebral angiograms of seventeen patients who had been treated for residual aneurysms. Results: Complementary treatment was performed in 8 cases by means of surgery and in 9 cases by means of GDC embolization. There were eleven females and six males with an age variation between 29 and 78 years. The mean duration of angiographic follow-up was 17.3 months. Of the seventeen cases that were treated for residual aneurysms, fourteen achieved complete occlusion. Of 17 retreated patients, fifteen patients had good recovery according to the Glasgow Outcome Scale. Conclusion: When occlusion after endovascular or surgical treatment is incomplete, a new multidisciplinary approach should be carried out. Given our experiences, we recommend coil embolization of the choice in cases that the residual aneurysmal neck had been narrowed by previous clipping. On the other hand, if the residual aneurysm has enough space to clip but not enough to coil, we recommend the microsurgical clipping.

Intra-Arterial Thrombolysis Using Double Devices: Mechanicomechanical or Chemicomechanical Techniques

  • Park, Hyun;Hwang, Gyo-Jun;Jin, Sung-Chul;Bang, Jae-Seung;Oh, Chang-Wan;Kwon, O-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.2
    • /
    • pp.75-80
    • /
    • 2012
  • Objective : To optimize the recanalization of acute cerebral stroke that were not effectively resolved by conventional intraarterial thrombolysis (IAT), we designed a double device technique to allow for rapid and effective reopening. In this article, we describe the feasibility and efficacy of this technique. Methods : From January 2008 to September 2009, twenty patients with acute cerebral arterial occlusion (middle cerebral artery : n=12; internal carotid artery terminus : n=5; basilar artery : n=3) were treated by the double device technique. This technique was applied when conventional thrombolytic methods using drug, microwires, microcatheters and balloons did not result in recanalization. In the double device technique, two devices are simultaneously placed at the lesion (for example, one microcatheter and one balloon or two microcatheters). Chemicomechanical or mechanicomechanical thrombolysis was performed simultaneously using various combinations of two devices. Recanalization rates, procedural time, complications, and clinical outcomes were analyzed. Results : The initial median National Institute of Health Stroke Scale (NIHSS) was 16 (range 5-26). The double device technique was applied after conventional IAT methods failed. Recanalization was achieved in 18 patients (90%). Among them, 55% (11 cases) were complete (thrombolysis in cerebral infarction 2B, 3). The median thrombolytic procedural time including the conventional technique was $135{\pm}83.7$ minutes (range 75-427). Major symptomatic hemorrhages (neurological deterioration ${\geq}4$ points in NIHSS) developed in two patients (10%). Good long term outcomes (modified Rankin Scale ${\leq}2$ at 90 days) occurred in 25% (n=5) of the cases. Mortality within 90 days developed in two cases (10%). Conclusion : The double device technique is a feasible and effective technical option for large vessel occlusion refractory to conventional thrombolysis.