• Title/Summary/Keyword: Complete arch

Search Result 125, Processing Time 0.03 seconds

Surgical Treatment of Eosinophilic Granuloma in Cervical Spine - 3 Cases Report - (경추에서 발생한 호산구 육아종의 수술적 치료 - 3예 보고 -)

  • Chung, Jae-Yoon;Lee, Jae-Joon;Kim, Jong-Seon;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2006
  • The involvement in the spine of eosinophilic granuloma is not common. Especially, involvement of cervical spine and posterior neural arch is quite rare. In addition, radiographic findings including magnetic resonance images of eosinophilic granuloma are manifested as vertebral body collapse, loss of pedicle and paravertebral soft mass formation; it must be differentiated with other conditions, such as malignant bone tumor, metastatic cancer or tuberculous spondylitis. We experienced three cases of eosinophilic granuloma involving posterior neural arch of C4, C7, and body of C4 respectively, which were performed surgical treatment and achieved complete healing. We report these cases with review of literatures.

  • PDF

Intraoral Scan for Virtual Skull-Dentition Hybrid Images of Young Patients (가상 골격-치열 하이브리드 이미지 생성을 위한 구강 스캐너의 활용)

  • Lee, Joohee;Yang, ByoungEun;Lee, Hyelim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.57-64
    • /
    • 2022
  • Additional dentition images are needed because the dentitions are distorted in cone-beam computed tomography (CBCT) due to streak artifacts and non-uniformity of the x-ray beam. The purpose of this study is to evaluate the feasibility of improving the dentition image of CBCT scan with intraoral scanner instead of plaster models. Maxilla images from plaster models, two intraoral scanners, and CBCT of 20 patients aged 12 to 18 were used in this study. With one of the intraoral scanners, the full arch was scanned by three segments and combined into a complete full arch. Virtual skull-dentition hybrid images from intraoral scanners were superimposed with the images from plaster models to evaluate the coordinate value difference and distance at reference points. The results showed that the coordinate value difference and distance were smallest with segmented intraoral scan, which showed only 2 ㎛ distance. Intraoral scan may provide good dentition images for virtual skull-dentition images.

AN EXPERIMENTAL STUDY ON THE ACCURACY OF INTEROCCLUSAL RECORDING MATERIALS (교합관계 기록 재료의 정확성에 관한 임상적 비교 연구)

  • Park, Hong Yul;Chang, Ik Tae;Kim, Kwang Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.91-108
    • /
    • 1990
  • The purpose of this study was to compare the maganitude of the discrepancies of the mounting errors in according to the states of dentitions, and to the superoinferior, anteroposterior, and rightleft driecetions. GROUP I. : Fourteen patients 22 to 26 years of age with a full complement of teeth, were used in the study. The criteria fro patient selection were a complete dentition, sparse restorarive treatment, and adequate posterior and anterior occlusan stops. And they had no sign and sympton at TMG area. GROUPII. : Eigth patients 37 to 62 years of age with bilateral free ends. The criteria for patient selection were Kennedy classification class 1 cases, and adequate posterior and anterior stops. And the opposite dentitions were a full complement of teeth. Irreversible hydrocolloid impresiion of each arch was taken of each patient. These were immediatel poured in stone and mounted on a Denar Mark II. Articulator with the arbitrary slidematic face-bow. With hand articulation th e mandibular cast was mounted to the maxillary cast in centric occlusion. Five types of interocclusal records were taken of each patient : (1) aluwax (2) baseplate wax; (3) znic oxide-eugenol pasts; (4) polyether (Ramitec); (5) modeling compound. All measurement of the five selected recording materials were compared with those of the hand-articulated full arch models in centric occlusion or maximum interdigitation. The results were as follows; 1. There were statistical differences in amount of devitation in according to the materials and the states of dentition. The amount of deviation of compound was the largest. 2. There were statistical differences in amount of deviation in complete dentition at all directions. The amount of diviation of compound was the largest. And at the right-left direction the amount of znic oxide-eugenol paste was larger than that of baseplate wax. 3. There was a statistical difference in amount of diviations in partial edentulous dentition at the superoinferior direction. The amount of deviation of compound was larger than that of znic oxide-eugenol paste. 4. There was as statistical difference in amount of deviations in partial edentulous dentition at the right-left direction. The amount of deviation of baseplate wax was larger that tnat of polyether. 5. There was not a statistical difference in amount of diviation in partial edentulous dentition at the anteroposterior direction.

  • PDF

Accuracy of conventional and digital mounting of dental models: A literature review (치과용 모형의 모형 부착 과정에서 발생하는 오차에 대한 문헌 고찰)

  • Kim, Cheolmin;Ji, Woon;Chang, Jaeseung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.146-152
    • /
    • 2021
  • Accurate transfer of the maxillo-mandibular relationship to an articulator (i.e., mounting) is critical in prosthetic treatment procedures. In the current study, a PubMed search was performed to review the influencing factors for the maxillo-mandibular relationship's accuracy. The search included digital mounting as well as conventional gypsum cast mounting. The results showed that a greater amount of displacement was introduced during positioning the maxillary and mandibular models to interocclusal records rather than the dimensional change of registration material. Most intraoral scanners resulted in an accurate reproduction of the maxillo-mandibular relationship for posterior quadrant scanning; however, the accuracy was declined as the scan area increased to a complete arch scan. The digital mounting accuracy was also influenced by the image processing algorithms and software versions, especially for complete arch scans.

Early and Mid-term Changes of the Distal Aorta after Total Arch Replacement for Acute Type A Aortic Dissection

  • Choi, Chang Hu;Park, Chul Hyun;Jeon, Yang Bin;Lee, So Young;Lee, Jae Ik;Park, Kook Yang
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Background: Total arch replacement (TAR) is being more widely performed due to recent advances in operative techniques and cerebral protective strategies. In this study, the authors reviewed the relationship between TAR and early- and mid-term changes of the false lumen after TAR in acute type A aortic dissection. Materials and Methods: Twenty-six patients (aged, $54.7{\pm}13.3$ years) who underwent TAR for acute type A dissection between June 2004 and February 2012 were reviewed. The relationship between the percentage change in the aortic diameter and the false lumen patency status was assessed by examining the early and late postoperative computed tomography imaging studies. Results: There were two in-hospital mortalities, one late death, and three follow-up loses. The mean follow-up duration for the final 21 patients studied was $54{\pm}19.0$ months (range, 20 to 82 months). The incidence of false lumen thrombosis within 2 weeks of surgery in the proximal, middle, and distal thoracic aorta, and the suprarenal and infrarenal abdominal aorta were 67%, 38%, 38%, 48%, and 33%, respectively, and 57%, 67%, 52%, 33%, and 33% for those examined at a mean of $49{\pm}18$ months after surgery, respectively. The false lumen regressed in 11 patients (42.3%). The aortic diameters were larger in the patients with a patent false lumen than those with a thrombosed false lumen at all levels of the descending aorta (p <0.05). Conclusion: TAR and a more complete primary tear-resection can be accomplished with a relatively low-risk of morbidity and mortality. Enlargement of the distal aorta significantly correlated with the false lumen patency status.

Hybrid Endovascular Repair for Type I Endoleak after Stent Grafting of Chronic Stanford Type B Aortic Dissection (만성 Stanford B형 대동맥 박리로 하행 대동맥 스텐트 도관 삽입술 후 발생한 제I형 Endoleak의 치료에 시행한 Hybrid 혈관내 술식)

  • Kim, Kwan-Wook;Cho, Sang-Ho;Shim, Won-Heum;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.428-432
    • /
    • 2010
  • A 67 years old male patient was admitted with back pain that had recurred from 6 months previously. Eleven years previously, he underwent stent grafting at the descending thoracic aorta for a chronic Stanford type B aortic dissection. The preoperative computed tomography showed aortic dissection from the origin of the left subclavian artery to the bifurcation of the abdominal aorta, and there was a type I endoleak at the proximal portion of the stent graft and aneurysmal dilatation of the descending aorta. A hybrid endovascular repair was successfully performed, and this involved debranching and rerouting the aortic arch vessels under extracorporeal cardiopulmonary bypass and then this was followed 13 days later by stenting in the ascending aorta, the aortic arch and the descending aorta. The postoperative computed tomography showed complete exclusion of the type I endoleak. After discharge, he has been followed up for 8 months without any problems.

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption using mandibular suction denture with closed mouth technique: a clinical report (치조골 흡수가 심한 완전 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Ko, Chang Woo;Min, Byungkwee;Yang, Hong-so;Lim, Hyun-Pil;Yun, Kwidug;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • When it comes to treat patient with loss of vestibule, conventional denture impression have limitation which can cause problems of excessive border extension. Suction denture with closed mouth technique which was introduced to solve this problem, forms negative pressure being sealed denture flanges by mobile mucosa when the patient swallows and chews. Also, it can decrease patient's visiting time by taking impression and gothic arch tracing at once. In this case, considering patient's chief complain which is a loose fit of present lower denture, suction dentures with closed mouth technique was planned.

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.

The Effect of Lip Adhesion in Unilateral Complete Cleft Lip (일측성 완전구순열에서 구순접합술의 효과)

  • Ryu Sun-Youl;Kim Tae-Hee;Hwang Ung;Kook Min-Suk;Kim Sun-Kook;Han Chang-Hun
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.7 no.1
    • /
    • pp.1-16
    • /
    • 2004
  • In the recent time, early correction of the congenital anomalies has become the focus of contemporary cleft lip care, The reason of that is mostly psychologic factor of children are respected, Although the propound object of lip adhesion is not esthetic improvement, that able to satisfy sufficiently parents of cleft children, In the unilateral or bilateral clefts, a preliminary lip adhesion has been advocated as a mean of narrowing the cleft at an early phase, of improving the nasal contour, of molding the alveolar arch, and of easing and improving the result of a definitive lip repair. The present study was earned out to investigate the effect of lip adhesion. We performed the Millard's high-half underminded adhesion and Seibert's lip adhesion followed by modified Millard's cheiloplasty for five infants had unilateral complete cleft lip. The lip adhesion reduced the actual deformity by molding the maxillary alveolar segments into better relationship and allows a easy cheiloplasty so that led to more perfect final lip result, Both Millard's high-half underminded adhesion and Seibert's lip adhesion were available methods to adhere a wide cleft lip, Especially, Seibert's lip adhesion had more advantages such as enhancement of the force of adhesion, correction of the deviated columella and acquirement of the esthetic upper lip continuity. These results suggest that the lip adhesion followed by cheiloplasty for wide unilateral complete cleft lip patients provide more favorable final result by molding the maxillary alveolar segments into better relationship.

  • PDF

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.