• Title/Summary/Keyword: Complete Denture

Search Result 298, Processing Time 0.022 seconds

Comparison of metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture (상악 총의치 정중 파절 수리 시 금속선 및 유리섬유의 보강효과 비교)

  • Lee, Jung-Ie;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.284-291
    • /
    • 2013
  • Purpose: This study compared fracture strength and fracture modes between metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture. Materials and methods: In this study, fracture was reproduced on center of maxillary complete dentures and the denture was repaired with auto-polymerizing resin. The experimental groups (n = 10) were subjected to the following condition: without reinforcing material (control group), reinforcing with metal wire (W group), reinforcing with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheon, Korea, G group). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The Kruskal-wallis test and the Mann-whitney U test were performed to identify statistical differences at ${\alpha}=.05$. Results: W group showed the highest value of fracture strength, there was no significant difference (P>.05) between control group and G group. Control group and W group showed anteroposterior fracture mainly, group W showed adhesive fracture of denture base and reinforcing material. Conclusion: In limitation of this study, the glass fiber did not improve the fracture strength of repaired maxillary complete denture, and adhesive failure was occurred along the lines of glass fiber.

Vertical Dimension in Complete Denture : A Literature Review & Clinical Procedures (총의치 수직고경 설정에 대한 고찰)

  • Chung, Jun-Yong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.185-195
    • /
    • 2002
  • Purpose This article describes the historic and clinical aspects of the determination of the vertical dimension of occlusion and the synoptic procedure of the determination of the vertical dimension of occlusion in complete denture. The determining procedure of the susceptible vertical dimension of occlusion is one of the most important steps in construction of complete denture and prosthodontic treatment. It is considered essential for the improvement and the recovery of facial esthetics and stomatognathic functions. Results Several methods have been suggested for measurement of the vertical dimension of occlusion in the construction of complete denture and the prosthodontic rehabilitation. These range from pre-extraction records to the use of physiologic rest position, swallowing, phonetics, esthetics and facial proportion, etc. But, there is no universally accepted or completely accurate method. There seems to be no significant advantages of one technique other than those of cost, time and equipment requirements, and seems to be in controversial in determining the vertical dimension. Conclusion The vertical dimension of occlusion should be determined and reinspected carefully by dentist for a successful prosthesis with several methods. The more investigations are necessary for more objective and scientific techniques in determining the vertical dimension of occlusion.

A COMPARATIVE STUDY ON THE SEVERAL METAL REINFORCEMENT METHODS OF MAXILLARY COMPLETE ACRYLIC RESIN DENTURE BASE (수종의 상악 총의치수지상 금속보강법에 관한 비교연구)

  • Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.363-372
    • /
    • 1996
  • A common site of fracture in maxillary complete denture is on the anteroposterior midline that coincides with the notch for relief of the labial frenum. Various approaches to reduce the incidence of this type of fracture have been suggested. The most widely used technique is the reinforcement of acrylic resin denture base with several solid metal forms. But few comparative studies on the efficacy of metal reinforcements have been reported. This study was conducted to compare reinforcing effects of commonly available metal reinforcements, which include wire, metal mesh embedded in the denture base and metal plate affixed to the impression surface of denture base by silicoating technique. This was load on the posterior. The strain gauges were oriented perpendicular to the anteroposterior midline of maxillary polished denture surface at one labial and the four palatal sites Non-renforced denture was used as control. The results were as follows : 1. In the non-reinforced denture group, only tensile strains on the palatal polished surface were observed. The tensile strains decreased in the order of incisive papilla, posterior denture border area, mid palatal area and rugae area. Compressive strain was observed on the labial polished surface. 2. As compared with the non-reinforced denture group, the metal plate or the metal mesh reinforced denture groups showed reduced palatal tensile strains,and the metal mesh reinforcement had a better reinforcing effect than the metal plate. But both reinforced denture groups showed no difference in the amount of compressive strain on the labial polished surface when compared to the non-reinforced denture group. 3. The metal wire positioned just above the labial notch decreased the compressive strain on the labial polished surface. But the presence of metal wires in the palatal polished surface caused increase in tensile strains in the area.

  • PDF

Fabrication of immediate complete denture using Campagna tray technique (전악 발치 환자에서 캠퍼그나 트레이를 적용한 즉시의치 수복 증례)

  • Kim, Nam-Hoon;Kim, Jong-Eun;Oh, Kyung Chul;Chung, Moon-Kyu;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.331-335
    • /
    • 2017
  • An immediate complete denture is considered as restoration for lost natural teeth, which is fabricated following the extraction of the remaining teeth. Current esthetics and function can be retained by using immediate denture without edentulous period. However, the major disadvantages of immediate denture relate to the difficulties associated with taking accurate definitive impression and predicting the results of immediate denture. In this case report, the Campagna tray technique was used to take the final impression in a 49-year-old male patient presented with all remaining teeth diagnosed as hopeless teeth. Surgical templates were used for alveoloplasty after extraction. The immediate complete dentures were then delivered. The clinical assessments of immediate dentures showed good esthetic and functional outcomes. The patient showed high level of satisfaction.

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Shah, Farhan Khalid;Gebreel, Ashraf;Elshokouki, Ali Hamed;Habib, Ahmed Ali;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.61-71
    • /
    • 2012
  • PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.

Fabrication of CAD-CAM complete denture using existing provisional denture and digital facebow transfer (기존 임시의치와 디지털 안궁이전을 이용하여 상하악 CAD-CAM 총의치 수복 증례)

  • Jaehyeok Ro;Haemin Bang;Sangwon Park;Hyun-Pil Lim;Kwi-Dug Yun;Chan Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.268-274
    • /
    • 2023
  • In this case, a CAD-CAM complete denture that can be easily remanufactured and reduced the number of visits was decided in consideration of the fact that it was difficult to visit the dental hospital and many existing dentures were lost because the patient was inpatient in a nursing hospital. In order to reflect the shape, vertical dimension, and maxillomandibular relationship of the existing provisional dentures adapted by the patient to the fabrication of the final denture, the existing provisional dentures were scanned and closed mouth impression was taken with the printed individual tray. After digital facebow transfer using UTS CAD and arranging artificial teeth in CAD software, the maxillary and mandibular complete dentures were fabricated by milling the denture base and artificial teeth at once with the monolithic disc.

A Study of Complete Denture Stability (총의치 안정에 대한 연구)

  • Lee, Jai-Youl
    • Journal of Technologic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.15-18
    • /
    • 1984
  • A denture that shifts easily in response to latterally applied forces can cause a disruption in the border seal or prevent the denture base from Correctly relating to the supporting tissue. The factors that Contribute to stability include ridge height and conformation, base adaptation, residual ridge relationships, occlusion harmony, and Muscle control. These factors can be condensed into the following categories; 1. The relationship of the denture base to the underlying tissue. 2. The relationship of occlusal harmony. 3. The relationship of the denture surface and border to the surrounding muscle. 4. The location of artificial tooth.

  • PDF

A case of removable partial denture restoration using implant supported surveyed crown in a maxillary edentulous patient (상악 무치악 환자에서 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복 증례)

  • Seong, Si Young;Choi, Yeon Jo;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • When planning oral rehabilitation for maxillary edentulous patients, fixed prosthetic restoration using implants, complete denture restoration or overdentures using implants can be considered as treatment methods. In the case of complete denture restoration, it does not require additional surgery and is relatively economical. In the case of implant-supported fixed prostheses, the functional part is generally superior to that of complete denture restoration, but there are cases in which implant placement is clinically difficult. Recently in consideration of the patient's needs and the condition of the remaining alveolar bone, after partial implant placement, a method of restoring with a removable partial denture using implant-supported surveyed crown is also being attempted. This case is a case of performing a removable partial denture restoration using implant-supported surveyed crown in the anterior maxilla, and showing satisfactory esthetic and functional results.

Complete Denture Occlusion (총의치 교합)

  • Paek, Janghyun
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.82-89
    • /
    • 2017
  • Proponents of bilaterally balanced occlusion believe that this occlusal concept is important for denture retention and stability. However, the critical appraisal of the literature reveals no scientific evidence to support the bilaterally balanced occlusion as the ideal occlusal concept for conventional complete dentures. Current evidence suggests that the occlusal concept has little influence on clinical outcomes or patient satisfaction. Additional randomized controlled clinical trials should be developed taking into account the influence of mucosal resiliency, alveolar ridge anatomy, and parafunctional activities on occlusal concept choice. In this paper, various types of complete denture occlusion (bilaterally balanced occlusion, lingualized occlusion, canine-guided occlusion) will be reviewed and compared.

  • PDF