A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI (1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Han-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.244-252
    • /
    • 2009
  • The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$ $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:$-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90:$-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110:$-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130:$-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.

  • PDF

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

An Exploration For Future Emerging Technologies by Science Mapping and a Dynamic Portfolio Setting for Government R&D Strategy (과학지도 작성을 통한 미래기술 발굴 및 정부R&D의 동적 투자방향성 설정 연구)

  • Yang, He-Young;Son, Suk-Ho;Han, Min-Kyu;Han, Jong-Min;Yim, Hyun
    • Journal of Technology Innovation
    • /
    • v.19 no.3
    • /
    • pp.1-29
    • /
    • 2011
  • Korean government built "2040 Science and Technology Future Vision" in order to show positive future scenarios and suggest a long-term guideline for a progress in science and technology. The S&T Future Vision was built based on an analysis of global megatrends and a prospect of domestic social change. After building S&T Future Vision, the "Government R&E Strategy"s was established as a follow-up action plan. The Government R&D Strategy consists of lists of future emerging technologies for future leadership, government R&D investment status and investment portfolio plans. Exploring future emerging technologies aggressively and making a governmental R&D strategic policy are requirements for national competitiveness, leadership in the world. Therefore search and selection for future emerging technologies is getting more and more important recently. Generally qualitative methodologies have been used such as expert-panel discussion method and portfolio analysis with expert valuation method in order to explore future technologies. These experts-based qualitative methodologies are well defined but lacking in some objectivity because size of expert-panels has limitations. We suggest a quantitative methodology, science mapping method to compensate this shortcoming in this study. There is another limitation related governmental R&D strategy which is that general R&D portfolios are static until a point of technology realization. We also propose a dynamic R&D investment portfolio which present different portfolios at a intermediate point and a point of technology realization. We expect this try with science mapping method and a dynamic R&D portfolio could strengthen strategic aspect of government R&D policy.

  • PDF

A Study on Commemoration Culture of Vietnam War Memorials in Vietnam (베트남전쟁 메모리얼에 나타난 기념문화)

  • Lee, Sang-Suk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.26-38
    • /
    • 2011
  • The purpose of this study was to analyze the commemoration culture of Vietnam War Memorials (VWM) in Vietnam. Through site survey, the researcher selected 23 VWM in Vietnam and analyzed 5 categories: memorial type, design concept and narratives, location and spatial form, landscape elements, and content expressed in landscape details. The results are as follows: 1. Because of the long, drawn out Vietnam War, which lasted from 1955 to 1975, VWM were divided into 10 types mainly as soldier cemeteries based on a traditional memorial style, battlefields and places of tragedies considering sense of place, war museums representing victory and atrocity in war, and peace parks promoting reconciliation and peacemaking. 2. The analysis revealed that the main concepts and narratives of VWM were to value the victims of the Vietnam War, remember soldiers' contributions, highlight the victory in war and resistance to the United States, and express a sense of place. Peacemaking applied only to My Lai Peace Park and Han-Viet Hoa Binh Cong Vien, built by international cooperation. 3. Cemeteries and appreciation memorials were designed to follow a traditional memorial space form that highly regard both axis and symmetry. The design concept at battlefields and places where tragedies occurred depended mainly upon a sense of place and used symbolic landscape elements to compensate for the undefined concept. 4. Sculptures and towers were mainly used to highlight war victory and resistance as the representative style of a Socialist country, weapons and pictures exhibited in war museums and battlefield showed the reality and strain of war. Symbolic elements of Buddhism and Confucianism were often introduced as a way to venerate the memory of deceased persons. 5. The state and heroic actions in the Vietnam War were realistically depicted on sculptures and walls. Also, the symbolic phrase, 'TO-QUOC-GUI-CONG' meaning 'our country remember your achievement', were written on the memorial tower and 'Quagmiire' was used to metaphorically represent the difficulties faced by the U.S. military on battlefields during the war and the uncertainly that pervaded U.S. society in those days. 6. In VWM, ideologies like nationalism, patriotism, socialism, capitalism were mixed and traditional cultures like Buddhism, Confucianism, Taoism were inherent. Differing from their Confucianism culture, war heroes, particularly including women, were often described by sculpture, monument, and pictures and the conflict in and outside the country regarding the Vietnam War was shown. Further study will be required to analyze design characteristics of VWM in the u.s. and to understand the difference in commemoration cultures between Vietnam and the U.S.

Carbofuran Cytotoxicity on Rat Fibroblast Cells and Compensation Effects of Phenobarbital Sodium and 3-Methycholanthrene on Its Toxicity (살충제 Carbofuran이 쥐의 NIH3T3 섬유모세포에 끼치는 독성 및 Phenobarbital Sodium과 3-Methylcholanthrene에 의한 보상효과)

  • Han, Seong-Soo;Rim, Yo-Sup
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 1997
  • This study was carried out to investigate the effects of phenobarbital sodium(PB) and 3-methylcholanthrene(3-MC) on carbofuran cytotoxicity and to develop antitoxic agents based on the effectivness. Experimental groups for carbofuran cytotoxicity were divided into five groups ; medium alone and four treatments of carbofuran (1, 25, 50 and $100{\mu}M)$, and those for compensation effects were divided into six groups ; medium alone, $IC_{50}$ carbofuran and four combinations of carbofuran and PB or 3-MC($IC_{50}$ carbofuran plus 1, 25, 50, $100{\mu}M$ of PB and 3-MC, respectively). After incubation for 48 hrs under the same conditions, MTT(Tetrazolium MTT), NR(Neutral red) and SRB(Sulforhodamine B protein) assay were performed. Fifty percentage inhibition of MTT, NR, and SRB against carbofuran in rat fibroblast cell were 60.7, 82.5 and $87.0{\mu}M$, respectively. At the combination treatments of $IC_{50}$ of carbofuran and $100{\mu}M$ of PB, the significant compensation effects were observed from the results of MTT and NR but not from that of SRB absorbance. And at the combination treatments of $IC_{50}$ of carbofuran and 3-MC, the relatively significant compensation effects were found at $50{\mu}M$ 3-MC from the results of MTT and at $100{\mu}M$ 3-MC from that of NR and SRB absorbances, respectively. From the results of light microscopy, combination treatments of $carbofuran(IC_{50})$ and PB or 3-MC showed good regeneration in carbofuran toxicity of rat fibroblast cells. These results suggest that PB or 3-MC can compensate the cytotoxity of carbofuran insecticide in rat NIH3T3 fibroblast cells.

  • PDF

Characteristic of Aromatic Amino Acid Substitution at α96 of Hemoglobin

  • Choi, Jong-Whan;Lee, Jong-Hyuk;Lee, Kwang-Ho;Lee, Hyean-Woo;Sohn, Joon-Hyung;Yoon, Joon-Ho;Yeh, Byung-Il;Park, Seung-Kyu;Lee, Kyu-Jae;Kim, Hyun-Won
    • BMB Reports
    • /
    • v.38 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • Replacement of valine by tryptophan or tyrosine at position $\alpha$96 of the $\alpha$ chain ($\alpha$96Val), located in the ${\alpha}_1{\beta}_2$ subunit interface of hemoglobin leads to low oxygen affinity hemoglobin, and has been suggested to be due to the extra stability introduced by an aromatic amino acid at the $\alpha$96 position. The characteristic of aromatic amino acid substitution at the $\alpha$96 of hemoglobin has been further investigated by producing double mutant r Hb ($\alpha$42Tyr$\rightarrow$ Phe, $\alpha$96Val$\rightarrow$Trp). r Hb ($\alpha$42Tyr$\rightarrow$Phe) is known to exhibit almost no cooperativity in binding oxygen, and possesses high oxygen affinity due to the disruption of the hydrogen bond between $\alpha$42Tyr and $\beta$99Asp in the ${\alpha}_1{\beta}_2$ subunit interface of deoxy Hb A. The second mutation, $\alpha$96Val$\rightarrow$Trp, may compensate the functional defects of r Hb ($\alpha$42Tyr$\rightarrow$Phe), if the stability due to the introduction of trypophan at the $\alpha$96 position is strong enough to overcome the defect of r Hb ($\alpha$42Tyr$\rightarrow$Phe). Double mutant r Hb ($\alpha$42Tyr$\rightarrow$Phe, $\alpha$96Val$\rightarrow$Trp) exhibited almost no cooperativity in binding oxygen and possessed high oxygen affinity, similarly to that of r Hb ($\alpha$42Tyr$\rightarrow$Phe). $^1$H NMR spectroscopic data of r Hb ($\alpha$42Tyr$\rightarrow$Phe, $\alpha$96Val$\rightarrow$Trp) also showed a very unstable deoxy-quaternary structure. The present investigation has demonstrated that the presence of the crucible hydrogen bond between $\alpha$42Tyr and $\beta$99Asp is essential for the novel oxygen binding properties of deoxy Hb ($\alpha$96Val$\rightarrow$Trp).

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Phoria Changes Caused by Lens Adaptation after Wearing of Horizontal Prism Lens and Spherical Lens (수평 프리즘렌즈와 구면렌즈 착용 후 렌즈적응에 의한 사위도의 변화)

  • Lee, Min Jae;Kim, Sang-Yeob;Wee, Sung-Hyun;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.53-59
    • /
    • 2016
  • Purpose: To investigate an individual phoria compensating effect by measuring the lens adaptation after wearing horizontal prism or spherical lenses at near. Methods: 103 subjects (63 males and 40 females) aged $22.43{\pm}2.07years$ participated for this study. Refractive errors of subjects were fully corrected, and subjects were classified into three groups; esophoria, orthophoria and exophoria. The adaptation test of prism and spherical lenses was performed immediately, 15 minutes and 30 minutes after wearing lenses with $OU\;2\;{\Delta}\;BO$ and S+1.00 D for an esophoria group and $OU\;2\;{\Delta}\;BI$ and S-1.00 D for orthophoria and exophoria groups, respectively. Each measured phoria was compared to phoria measured with fully corrected condition, and the phoria changing effects about both lenses was analyzed. Results: The mean of phoria by prism lenses significantly decreased for every group. The mean of phoria by spherical lenses also significantly decreased in orthophoria and exophoria groups. The esophoria group showed a decreasing tendency but has no significance. The decreased phoria value by prism lens was classified into three steps; 90~100%, 0~10% and 50% or more. According to results of individual distribution ratio, it was 5, 64 and 24 subjects at 30 minutes after wearing lenses, respectively. The decreased phoria value by spherical lens was classified into three steps; 90~100%, 0~10% and 50% or more. According to results of individual distribution ratio, it was 37, 53 and 41 subjects at 30 minutes after wearing lenses, respectively. The subjects having no phoria changed by both prism and spherical lenses were 37.9%. Conclusions: When prescribing to compensate the near horizontal phoria using prism or spherical lens, the pretest for lens adaptation should be taken before prescription.

Feasibility Study of Isodose Structure Based Field-in-Field Technique for Total Body Irradiation (전신조사방사선치료 시 Isodose Structure를 이용한 Field-in-Field Technique의 유용성 평가)

  • Lee, Yoon Hee;Ban, Tae Joon;Lee, Woo Seok;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: In Asan Medical Center, Two parallel opposite beams are employed for total body irradiation. Patients are required to be in supine position where two arms are attached to mid axillary line. Normally, physical compensators are required to compensate the large dose difference for different parts of body due to the different thicknesses compared to the umbilicus separation. There was the maximum dose difference up to 30% in lung and chest wall compared to the prescription dose. In order to resolve the dose discrepancy occurring on different body regions, the feasibility of using Fieid-in-Field Technique is investigated in this study. Materials and Methods: CT scan was performed to The RANDO Phantom with fabricated two arms and sent to Eclipse treatment planning system (version 10.0, Varian, USA). Conventional plan with physical lead compensator and new plan using Field-in-Field Technique were established on TPS. AAA (Anisotropic Analytical Algorithm) dose calculation algorithm was employed for two parallel opposite beams attenuation. Results: The dose difference between two methods was compared with the prescription dose. The dose distribution of chest and anterior chest wall uncovered by patient arms was 114~124% for physical lead compensator while Field-in-Field Technique gave 106~107% of the dose distribution. In-vivo dosimetry result using TLD showed that the dose distribution to the same region was 110~117% for conventional physical compensator and 104~107% for Field-in-Field Technique. Conclusion: In this study, the feasibility of using FIF technique has been investigated with fabricated arms attached Rando phantom. The dose difference was up to 17% due to the attached arms. It is shown that the dose homogeneity is within ${\pm}10%$ with the CT based 3-dimensional 4 step FIF technique. The in-vivo dosimetry result using TLD was showed that 95~107% dose distribution compared to prescription dose. It is considered that CT based 3-dimensional Field-in-Field Technique for the total body irradiation gives much homogeneous dose distribution for different body parts than the conventional physical compensator method and might be useful to evaluate the dose on each part of patient body.

  • PDF