• Title/Summary/Keyword: Comparison-Group Method

Search Result 1,633, Processing Time 0.04 seconds

The Characteristics of Population Flows in kwangju Metropolitan Area (光州 中心의 人口移動 特性에 관한 硏究)

  • Chouh, Hae-Chong
    • Journal of the Korean Geographical Society
    • /
    • v.28 no.1
    • /
    • pp.40-57
    • /
    • 1993
  • This paper aims to show the various aspects of migration in Kwangju merropolitan area, southwestern Korea, for a period of years 1980-1985. Migratory patterns are spatially extensive in countryside around Kwanfju, and due to high accessibility to the metropolitan area urban implosion emerges in the city. In Chonnam province where Kwangju is loca-ted, all cities and counties except for such in-dustrial areas as Yochon, and Kwangyang are experiencing population losses in terms of net migration by survival rate methods. Kwangju is the exceptionally one of in-migration areas in Chonnam, though its central part(Dong-Gu) is also an out-migrated area. Predominantly in-migration urban areas have high proportions of a student age group between 15-19 years, and that reflects the importance of the educational factor in migration analysis. The municipal authorities of Kwangju are planning to block the way of the middle sxhool students who live in the outskirts of Kwangju to entrance to high school in the city. Thant may stir up migrations into Kwangju for the elementary and middle school students, because the city id expected to provide educational opportunities higher and better than remaining Chonnam areas. Population of Kwangju would, therefore, grow as the students migrate into the city. The findings on the residential intra-city movement in selected 5 Dongs indicate that implications of a short-distance movement re noteworthy; neighbour to neighbour, and the nearest stop in the way from the outer Kwangju as well. Trends in a short-distance movement are in accord with Ravensteins's "law of migra-tion". But in casw of the inter-provincial migra-tion to Kwangju, the number of in-migrants from remoter Seoul is more than that from nearer Chonbuk province. Therefore it supports the fact that the movement between capital region and far off local cities overcomes a distance barrier. The temporary mobility for a day has been increased as the standard of living has improved and it reaches a peak on weekend or on con-secutive holidays. The number of temporal movers to Kwangju from capital region and Yongnam area, southeastern Korea has a greatincrease in terms of the frequency of the passengers' mobility, in particular on Myongjol(the ethnic and traditional festival day) in com-parison with on weekdays. By comparison with two largest Myongjols, the number of movers is more on Chusok(The Full Moon festival on lunar August) than on Sol (lunar new year's day). Annual peak point of weekday movers appears in August because of summer vacation. But the lowest one appears in June, which is related to the busy farming season. A patients' move for medical services in on the increase with a change of living conditions. It is especially true in the industrial counties such as Kwangyang and Yochon. By way of conclusion, it should be pointed out that one of the problems we face in survey of migration volume by the survival rate method is that the survival rate somtimes exceeds the value 1.0, in normal states of which should be under 1.0. it may be due to the shortcoming from the census statistics. We should not give therefore too much stress on the importance of migrations or moves as an element of changes in spatial pattern. In cinclusion, the results of the study show some geographic facts as the followings: 1. One of the outstanding phenomena in all types of movement is the seletivity of ages. The most important factors are related to education and employment. 2. Short-distance movement is carried out in accordance with Ravenstein's law, but in case long-distance movement, in-migration from capital region is prominent in spite of remoten-ces. The gravity between large cities such as Kwangju and Seoul, which has a frequent human movenent, causes urban implosion of small cities between those cities. 3. The temporary mobility for a day, in con-trast to that of permanent movement, is more related to transportation, and its volumes and annual variations are a large-scale. 4. Passengers' mobility is high in industrial cities. And the scope of patients' mobility is narrower than passengers'.

  • PDF

Comparison of an Automated Most-Probable-Number Technique TEMPO®TVC with Traditional Plating Methods PetrifilmTM for Estimating Populations of Total Aerobic Bacteria with Livestock Products (축산물가공품에서 건조필름법과 TEMPO®TVC 검사법의 총세균수 비교분석)

  • Kim, Young-Jo;Wee, Sung-Hwan;Yoon, Ha-Chung;Heo, Eun-Jeong;Park, Hyun-Jeong;Kim, Ji-Ho;Moon, Jin-San
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2012
  • We compared between an automated most-probable-number technique $TEMPO^{(R)}$TVC and traditional plating methods $Petrifilm^{TM}$ for estimating populations of total aerobic bacteria in various livestock products. 257 samples randomly selected in local retail stores and 87 samples inoculated with $E.$ $coli$ ATCC 25922, $Staphylococcus$ $aureus$ ATCC 12868 were tested in this study. The degree of agreement was estimated according to the CCFRA (Campden and Chorleywood Food Research Association Group) Guideline 29 and the agreement indicates the difference of two kinds methods is lower than 1 log base 10($log_{10}$). The samples of hams, jerky products, ground meat products, milks, ice creams, infant formulas, and egg heat formed products were showed above 95% in the agreement of methods. In contrast, proportion of agreement on meat extract products, cheeses and sausages were 93.1%, 92.1%, 89.1%, respectively. One press ham and five sausages containing spice and seasoning, two pork cutlets containing spice and bread crumbs, two meat extract product and two natural cheeses and one processing cheese with a high fat content, and one ice cream containing chocolate of all samples showed the discrepancy. Our result suggest that $TEMPO^{(R)}$TVC system is efficient to analyses total aerobic bacteria to compare manual method in time-consuming and laborious process except livestock products having limit of detection.

Comparison of the Rate of Demineralization of Enamel using Synthetic Polymer Gel (합성 폴리머 겔의 법랑질 탈회 속도 비교)

  • Lee, June-Hang;Shin, Jisun;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.190-199
    • /
    • 2019
  • $Carbopol^{(R)}$ 907 used as surface protecting agent in White's method is the one of the artificial caries lesion producing solution was discontinuing of production. New surface protecting material to substitute of $Carbopol^{(R)}$ 907 was required. The author prepared an artificial caries lesion producing solution as follows White's method with $Carbopol^{(R)}$ 907 and also another artificial caries lesion producing solution with $Carbopol^{(R)}$ $2050^{(R)}$. 96 flattened and polished enamel samples were immersed in a demineralizing solution of 0.1 mol/L lactic acid, 0.2% carboxyvinylpolymer and 50% saturated hydroxyapatite for 1, 2, 3, 4, 5, 6, 7, 9, 11, 15, 18 and 20 days. All samples from each group were subjected to polarized microscopy observed and image analysis for measuring the lesion depth. From the review of polarized images, the artificial caries lesion producing solution using $Carbopol^{(R)}$ 907 and $Carbopol^{(R)}$ 2050 can produced an artificial caries that was very similar to natural caries characters. From the regression analysis of the lesion depth produced by the artificial caries lesion producing solution using $Carbopol^{(R)}$ 907 and $Carbopol^{(R)}$ 2050, $Carbopol^{(R)}$ 2050 estimate as Y = 9.8X + 8.0 and $Carbopol^{(R)}$ 907 was Y = 8.4X - 0.4. R square value of $Carbopol^{(R)}$ 2050 and $Carbopol^{(R)}$ 907 was 0.965 and 0.945 respectively. The rate of demineralization by the artificial caries lesion producing solution using $Carbopol^{(R)}$ 2050 was faster than that of $Carbopol^{(R)}$ 907. And R square value of $Carbopol^{(R)}$ 2050 and $Carbopol^{(R)}$ 907 were very high and it means that the lesion depth was very high coefficient to demineralization period.

A Comparison of Tiotropium 18㎍, Once Daily and Ipratropium 40㎍, 4 Times Daily in a Double-Blind, Double-Dummy, Efficacy and Safety Study in Adults with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 Tiotropium 1일 1회, 1회 18㎍ 요법과 Ipratropium 1일 4회, 1회 40㎍ 요법의 치료효과 및 안전성 비교)

  • Kim, Seung Joon;Kim, Myung Sook;Lee, Sang Haak;Kim, Young Kyoon;Moon, Hwa Sik;Park, Sung Hak;Lee, Sang Yeub;In, Kwang Ho;Lee, Chang Youl;Kim, Young Sam;Kim, Hyung Jung;Ahn, Chul Min;Kim, Sung Kyu;Kim, Kyung Rok;Cha, Seung Ick;Jung, Tae Hoon;Kim, Mi Ok;Park, Sung Soo;Choi, Cheon Woong;Yoo, Jee Hong;Kang, Hong Mo;Koh, Won Jung;Ham, Hyoung Suk;Kang, Eun Hae;Kwon, O Jung;Lee, Yang Deok;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun;Shin, Won Hyuk;Kwon, Sung Yeon;Kim, Woo Jin;Yoo, Chul Gyu;Kim, Young Whan;Shim, Young Soo;Han, Sung Koo;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Mi Hye;Lee, Won Yeon;Yong, Suk Joong;Shin, Kye Chul;Choi, Byoung Whui;Oh, Yeon Mok;Lim, Chae Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Jung, Sung Soo;Kim, Ju Ock;Ko, Young Chun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.498-506
    • /
    • 2005
  • Background : This study compared the bronchodilator efficacy and safety of tiotropium inhalation capsules ($18{\mu}g$ once daily) with a ipratropium metered dose inhaler (2 puffs of $20{\mu}g$ q.i.d.) in patients with chronic obstructive pulmonary disease (COPD). Method : After the initial screening assessment and a two-week run-in period, patients received either tiotropium $18{\mu}g$ once daily or ipratropium $40{\mu}g$ four times daily over a period of 4 weeks in a double blind, double dummy, parallel group study. The outcome measures were the lung function, the daily records of the peak expiratory flow rate (PEFR), the patients' questionnaire, and the use of concomitant salbutamol. The forced expiratory volume in one second ($FEV_1$) and the forced vital capacity (FVC) were measured 5 minutes before inhalation, and 0.5, 1, 2 and 3 hours after inhaling the study drug on days 0, 14 and 28. Result : In 16 centers, 134 patients with a mean (SD) age of 66 (7) years and a predicted $FEV_1$ of 42 (12)% were analyzed. The trough $FEV_1$ response was significantly higher in the tiotropium group than in the ipratropium group after a four-week treatment period. The weekly mean morning PEFR of the tiotropium group was consistently higher than that of the ipratropium group during the 4-week treatment period with differences ranging from 12.52 to 13.88 l/min, which were statistically significant. Tiotropium was well tolerated by the COPD patients during the 4-week treatment period and had a similar safety profile to ipratropium. Conclusion : This study shows that tiotropium administrated once daily has a superior bronchodilator effect with a similar safety profile in treating COPD patients compared with ipratropium, inhaled four times daily.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Operative Treatment of Congenitally Corrected Transposition of the Great Arteries(CCTGA) (교정형 대혈관 전위증의 수술적 치료)

  • 이정렬;조광리;김용진;노준량;서결필
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.621-627
    • /
    • 1999
  • Background: Sixty five cases with congenitally corrected transposition of the great arteries (CCTGA) indicated for biventricular repair were operated on between 1984 and september 1998. Comparison between the results of the conventional(classic) connection(LV-PA) and the anatomic repair was done. Material and Method: Retrospective review was carried out based on the medical records of the patients. Operative procedures, complications and the long-term results accoding to the combining anomalies were analysed. Result: Mean age was 5.5$\pm$4.8 years(range, 2 months to 18years). Thirty nine were male and 26 were female. Situs solitus {S,L,L} was in 53 and situs inversus{I,D,D} in 12. There was no left ventricular outflow tract obstruction(LVOTO) in 13(20%) cases. The LVOTO was resulted from pulmonary stenosis(PS) in 26(40%)patients and from pulmonary atresia(PA) in 26(40%) patients. Twenty-five(38.5%) patients had tricuspid valve regurgitation(TR) greater than the mild degree that was present preoperatively. Twenty two patients previously underwent 24 systemic- pulmonary shunts previously. In the 13 patients without LVOTO, 7 simple closure of VSD or ASD, 3 tricuspid valve replacements(TVR), and 3 anatomic corrections(3 double switch operations: 1 Senning+ Rastelli, 1 Senning+REV-type, and 1 Senning+Arterial switch opera tion) were performed. As to the 26 patients with CCTGA+VSD or ASD+LVOTO(PS), 24 classic repairs and 2 double switch operations(1 Senning+Rastelli, 1 Mustard+REV-type) were done. In the 26 cases with CCTGA+VSD+LVOTO(PA), 19 classic repairs(18 Rastelli, 1 REV-type), and 7 double switch operations(7 Senning+Rastelli) were done. The degree of tricuspid regurgitation increased during the follow-up periods from 1.3$\pm$1.4 to 2.2$\pm$1.0 in the classic repair group(p<0.05), but not in the double switch group. Two patients had complete AV block preoperatively, and additional 7(10.8%) had newly developed complete AV block after the operation. Other complications were recurrent LVOTO(10), thromboembolism(4), persistent chest tube drainage over 2 weeks(4), chylothorax(3), bleeding(3), acute renal failure(2), and mediastinitis(2). Mean follow-up was 54$\pm$49 months(0-177 months). Thirteen patients died after the operation(operative mortality rate: 20.0%(13/65)), and there were 3 additional deaths during the follow up period(overall mortality: 24.6%(16/65)). The operative mortality in patients underwent anatomic repair was 33.3%(4/12). The actuarial survival rates at 1, 5, and 10 years were 75.0$\pm$5.6%, 75.0$\pm$5.6%, and 69.2$\pm$7.6%. Common causes of death were low cardiac output syndrome(8) and heart failure from TR(5). Conclusion: Although our study could not demonstrate the superiority of each classic or anatomic repair, we found that the anatomic repair has a merit of preventing the deterioration of tricuspid valve regurgitations. Meticulous selection of the patients and longer follow-up terms are mandatory to establish the selective advantages of both strategies.

  • PDF

Development of Detection Method for Oilfish (Ruvettus pretiosus and Lepidocybirium flavobrunneum) as a Food Materials not Usable in Foods (식품원료로 사용금지 대상인 기름치 (기름갈치꼬치 및 흑갈치꼬치) 판별법 개발)

  • Park, Yong-Chjun;Kim, Mi-Ra;Jung, Yong-Hyun;Shin, Joon-Ho;Kim, Kyu-Heon;Lee, Jae-Hwang;Cho, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • Since 1 June 2012, it is prohibited to sell oilfish as a food material but there are still many illegal cases of selling oilfish as if it is tuna or grilled Patagonian toothfish. So it is absolutely crucial to construct the system to distinguish the real food material from oilfish. There are two sorts of oil fish called Ruvettus pretiosus and Lepidocybirium flavobrunneum involved in Percifomes order and Gempylidae class. 16S DNA gene region in mitochondria was selected to design the specific primers. For design species-specific primer, the theoretical experiment were performed for the sequences of R. pretiosus, L. flavobrunneum, Thunnus thynnus, Thunnus albacores, Makaira mitsukurii and Xiphias gladius, registered at the Gene bank from the National Centre for Biotechnology Information, using BioEdit 7.0.9.0. program. Through the analysis of the result from experiments, it was possible to design the 4 kinds of primers to distinguish R. pretiosus and L. flavobrunneum. As a comparison group, 3 kinds of tuna and 4 kinds of billfishes were selected and experimental verification was performed. As a result, for R. pretiosus and L. flavobrunneum, R.P-16S-006-F/R.P-16S-008-R and L.F-16S-004-F/L.F-16S-006-R primers were selected eventually and PCR condition was established. In addition, 178bp and 238bp of PCR products were confirmed from the established condition and non-specific band was not amplified among similar species. Therefore, the species-specific primers developed in this study would be very useful and used in various ways such as internet shopping mall and illegal distributions with fast and scientific results.

Overview of Research Trends in Estimation of Forest Carbon Stocks Based on Remote Sensing and GIS (원격탐사와 GIS 기반의 산림탄소저장량 추정에 관한 주요국 연구동향 개관)

  • Kim, Kyoung-Min;Lee, Jung-Bin;Kim, Eun-Sook;Park, Hyun-Ju;Roh, Young-Hee;Lee, Seung-Ho;Park, Key-Ho;Shin, Hyu-Seok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.236-256
    • /
    • 2011
  • Forest carbon stocks change due to land use change is an important data required by UNFCCC(United Nations framework convention on climate change). Spatially explicit estimation of forest carbon stocks based on IPCC GPG(intergovernmental panel on climate change good practice guidance) tier 3 gives high reliability. But a current estimation which was aggregated from NFI data doesn't have detail forest carbon stocks by polygon or cell. In order to improve an estimation remote sensing and GIS have been used especially in Europe and North America. We divided research trends in main countries into 4 categories such as remote sensing, GIS, geostatistics and environmental modeling considering spatial heterogeneity. The easiest way to apply is combination NFI data with forest type map based on GIS. Considering especially complicated forest structure of Korea, geostatistics is useful to estimate local variation of forest carbon. In addition, fine scale image is good for verification of forest carbon stocks and determination of CDM site. Related domestic researches are still on initial status and forest carbon stocks are mainly estimated using k-nearest neighbor(k-NN). In order to select suitable method for forest in Korea, an applicability of diverse spatial data and algorithm must be considered. Also the comparison between methods is required.

Comparison of Antioxidant and Physiological Properties of Jerusalem Artichoke Leaves with Different Extraction Processes (추출방법에 따른 돼지감자 잎의 항산화 및 생리활성 비교)

  • Kim, Jae-Won;Kim, Jong-Kyoun;Song, In-Seong;Kwon, Eun-Sung;Youn, Kwang-Sup
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.1
    • /
    • pp.68-75
    • /
    • 2013
  • The physiological properties of water extracts from Jerusalem artichoke (Helianthus tuberosus L.) leaves (JAL) with different extraction processes (stirrer extraction, SE; reflux extraction, RE; autoclave extraction, AE; low temperature high pressure extraction, LTPE) were investigated. The freeze-dried powder yields of SE, RE, AE, and LTPE were 22.33%, 29.88%, 31.65, and 15.74%, respectively. AE showed the highest value of extract yield. The $a^*$ and $b^*$ values were higher in AE compared to other extracts. Total polyphenolics and flavonoids contents in AE was significantly higher than in other extracts. The amount of proanthocyanidin related substances were highest in LTPE (29.36 mg/g), followed by RE (21.57 mg/g), SE (20.35 mg/g), and AE (13.02 mg/g). The electron donating abilities of SE, RE, AE, and LTPE at a concentration of $500{\mu}g/mL$ (w/v) were 76.16%, 39.55%, 25.50%, and 12.59%, respectively. Reducing power for the four different processes was 1.79, 1.60, 1.51, and 1.17, respectively. Additionally the same tendency was observed with electron donating ability and reducing power for ABTS radical and nitrite scavenging abilities. AE and LTPE showed relatively high antioxidant activities. Alpha-glucosidase, xanthine oxidase, and angiotensin I-converting enzyme inhibitory activities of LTPE at a concentration of $500{\mu}g/mL$ (w/v) were somewhat higher than other extracts. Additionally, there was significantly higher or little lower inhibitory activity compared to the control group. In conclusion, we provided experimental evidence that extracts of JAL have potential as functional materials, and component analysis of JAL could be used as new cosmeceuticals. Also, LTPE is the superior method for the enhancement of biological activity.

The Effects of the Warm Ischemic Time, the Preserving Temperature and the Cryopreservation Solution on the Viability of Tracheas (온혈허혈시간과 냉동보존온도와 보존액 조성에 따른 기관의 생육성 비교)

  • Sa, Young-Jo;Park, Jae-Kil;Sim, Sung-Bo;Jin, Ung;Moon, Young-Kyu;Lee, Sun-Hee;Jo, Kuhn-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.283-291
    • /
    • 2009
  • Background: Tracheal reconstruction after extended tracheal resection still remains as a major surgical challenge because good clinical outcomes are usually correlated with limited tracheal resection. Recent investigations with a using cryopreserved trachea for the reconstruction of a trachea have been carried out to overcome this problem. In this study, we analyzed viability of tracheas, which is an important determining factor for the success of transplanting a cryopreserved trachea and the development of post-transplantation tracheal stenosis, according to three different experimental factors: 1) the warm-ischemic time, 2) the cryopreservation solution and 3) the preserving temperature, to determine a better cryopreservation protocol and a better composition of the cryopreservation solution. Material and Method: Rats tracheas were harvested for different warm-ischemic times (0 hr, 12 hrs, 24 hrs). The tracheas were treated with recombinant insulin growth factor-1 (IGF) and they were stored at three different temperatures $(4^{\circ}C,\;-80^{\circ}C,\;-196^{\circ}C)$ for two weeks. After two weeks, we thawed the stored trachea and isolated the cells of the tracheas with using type II collagenase. We cultured the cells for seven days and then we compared the cellular viability by the MTT reduction assay. Result: Though cryopreservation is required to preserve a trachea for a longer time period, the viability of the tracheas stored at $-80^{\circ}C$ and $-196^{\circ}C$ was significantly reduced compared to that of the tracheas stored at $4^{\circ}C$. The viability of the tracheas with warm-ischemic times of 12 hrs and 24 hrs was also reduced in comparison to the tracheas with a warm-ischemic time of 0 hrs. Our data showed that the warm ischemic time and the parameters of crypreservation negatively affect on trachea viability. However, a cryopresrvation solution containing IGF-1 improved the cellular viability better than the existing cryopreservation solution. For the warm ischemic time group of a 0 hr, the addition of IGF-1 improved the viability of trachea at all the preserving temperatures. Conclusion: These experiments demonstrate that the viability of cryopreserved trachea can improved by modifying the components of the crypreservation solution with the addition of IGF-1 and reducing the warm-ischemic time.