• Title/Summary/Keyword: Comparison-Group Method

Search Result 1,633, Processing Time 0.033 seconds

Validation of a physical activity classification table in Korean adults and elderly using a doubly labeled water method (한국 성인과 노인을 대상으로 이중표식수법을 이용한 신체활동분류표 타당도 평가)

  • Hye-Ji Han ;Ha-Yeon Jun;Jonghoon Park;Kazuko Ishikawa-Takata;Eun-Kyung Kim
    • Journal of Nutrition and Health
    • /
    • v.56 no.4
    • /
    • pp.391-403
    • /
    • 2023
  • Purpose: This study evaluated the validity of a physical activity classification table (PACT) based on total energy expenditure (TEE) and physical activity level (PAL) measured using the doubly labeled water (DLW) method in Korean adults and the elderly. Methods: A total of 141 (male 70, female 71) adults and elderly were included. The reference standards TEEDLW, PALDLW were measured over a 14-day period using DLW. A 24-hour physical activity diary was kept for three days (two days during the week and one day on the weekend). PALPACT was calculated by classifying the activity type and intensity using the PACT. PALPACT was multiplied by resting energy expenditure measured by indirect calorimetry to estimate TEEPACT. Results: The mean age of the study participants was 50.5 ± 18.8 years, and the mean body mass index was 23.4 ± 3.3 kg/m2. A comparison of TEEDLW and TEEPACT by sex and age showed no significant differences. The bias, the difference between TEEDLW and TEEPACT, was male 17.3 kcal/day and female -4.5 kcal/day. The percentage of accurate predictions (values within ± 10% of the TEEDLW) of TEEPACT was 58.6% in males and 54.9% in females, with the highest prediction values in the age group 40-64 years (70.9%) in males and over 65 years (73.9%) in females. The spearman correlation coefficient (r) between TEEPACT and TEEDLW was 0.769, indicating a significant positive correlation (p < 0.001). Conclusion: In this study, the use of a new PACT for calculating TEE and PAL was evaluated as valid. A web version of the software program and a smartphone application need to be developed using PACT to make it easier to apply for research purposes.

Comparison of vitamin K contents in different meats commonly consumed in Korea (국내에서 소비되는 육류의 부위별 비타민 K 함량 분석 및 비교)

  • Kim, Daedong;Lee, Seogyeong;Kang, Yuri;Shin, Jaehong;Park, Jin Ju;Kim, Hyun Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.1
    • /
    • pp.109-113
    • /
    • 2022
  • Vitamin K is a group of fat-soluble vitamins that naturally exist in phylloquinone (vitamin K1) and menaquinone (vitamin K2). In this study, the vitamin K content in different meats commonly consumed in Korea was analyzed using HPLC, and the analytical method was validated. Vitamin K1 was not detected in any of the meat samples. Vitamin K2 contents in different cuts of beef ranged from 0.00 to 5.87 ㎍/100 g, whereas the corresponding value in different parts of chicken ranged from 16.59 to 46.64 ㎍/100 g. In the case of pork, vitamin K2 contents varied from 4.33 to 22.90 ㎍/100 g. Among the different types of meat, the highest vitamin K2 content was found in boiled chicken meat and skin (46.64 ㎍/100 g). The analytical method was found to be reliable and had high accuracy. These results provide accurate nutritional information and contribute a food composition database for meat consumption.

Comparison of Effects of Normothermic and Hypothermic Cardiopulmonary Bypass on Cerebral Metabolism During Cardiac Surgery (체외순환 시 뇌 대사에 대한 정상 체온 체외순환과 저 체온 체외순환의 임상적 영향에 관한 비교연구)

  • 조광현;박경택;김경현;최석철;최국렬;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.6
    • /
    • pp.420-429
    • /
    • 2002
  • Moderate hypothermic cardiopulmonary bypass (CPB) has commonly been used in cardiac surgery. Several cardiac centers recently practice normothermic CPB in cardiac surgery, However, the clinical effect and safety of normothermic CPB on cerebral metabolism are not established and not fully understood. This study was prospectively designed to evaluate the clinical influence of normothermic CPB on brain metabolism and to compare it with that of moderate hypothermic CPB. Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to receive normothermic (nasopharyngeal temperature >34.5 $^{\circ}C$, n=18) or hypothermic (nasopharyngeal temperature 29~3$0^{\circ}C$, n=18) CPB with nonpulsatile pump. Middle cerebral artery blood flow velocity (VMCA), cerebral arteriovenous oxygen content difference (CAVO$_{2}$), cerebral oxygen extraction (COE), modified cerebral metabolic rate for oxygen (MCMRO$_{2}$), cerebral oxygen transport (TEO$_{2}$), cerebral venous desaturation (oxygen saturation in internal jugular bulb blood$\leq$50 %), and arterial and internal jugular bulb blood gas analysis were measured during six phases of the operation: Pre-CPB (control), CPB-10 min, Rewarm-1 (nasopharyngeal temperature 34 $^{\circ}C$ in the hypothermic group), Rewarm-2 (nasopharyngeal temperature 37 $^{\circ}C$ in the both groups), CPB-off and Post-CPB (skin closure after CPB-off). Postoperaitve neuropsychologic complications were observed in all patients. All variables were compared between the two groups. Result: VMCA at Rewarm-2 was higher in the hypothermic group (153.11$\pm$8.98%) than in the normothermic group (131.18$\pm$6.94%) (p<0.05). CAVO$_{2}$ (3.47$\pm$0.21 vs 4.28$\pm$0.29 mL/dL, p<0.05), COE (0.30$\pm$0.02 vs 0.39$\pm$0.02, p<0.05) and MCMRO$_{2}$ (4.71 $\pm$0.42 vs 5.36$\pm$0.45, p<0.05) at CPB-10 min were lower in the hypothermic group than in the normothermic group. The hypothermic group had higher TEO$_{2}$ than the normothermic group at CPB-10 (1,527.60$\pm$25.84 vs 1,368.74$\pm$20.03, p<0.05), Rewarm-2 (1,757.50$\pm$32.30 vs 1,478.60$\pm$27.41, p<0.05) and Post-CPB (1,734.37$\pm$41.45 vs 1,597.68$\pm$27.50, p<0.05). Internal jugular bulb oxygen tension (40.96$\pm$1.16 vs 34.79$\pm$2.18 mmHg, p<0.05), saturation (72.63$\pm$2.68 vs 64.76$\pm$2.49 %, p<0.05) and content (8.08$\pm$0.34 vs 6.78$\pm$0.43 mL/dL, p<0.05) at CPB-10 were higher in the hypothermic group than in the normothermic group. The hypothermic group had less incidence of postoperative neurologic complication (delirium) than the normothermic group (2 vs 4 patients, p<0.05). Lasting periods of postoperative delirium were shorter in the hypothermic group than in the normothermic group (60 vs 160 hrs, p<0.01). Conclusion: These results indicate that normothermic CPB should not be routinely applied in all cardiac surgery, especially advanced age or the clinical situations that require prolonged operative time. Moderate hypothermic CPB may have beneficial influences relatively on brain metabolism and postoperative neuropsychologic outcomes when compared with normothermic CPB.

Evaluation of White Matter Abnormality in Mild Alzheimer Disease and Mild Cognitive Impairment Using Diffusion Tensor Imaging: A Comparison of Tract-Based Spatial Statistics with Voxel-Based Morphometry (확산텐서영상을 이용한 경도의 알츠하이머병 환자와 경도인지장애 환자의 뇌 백질의 이상평가: Tract-Based Spatial Statistics와 화소기반 형태분석 방법의 비교)

  • Lim, Hyun-Kyung;Kim, Sang-Joon;Choi, Choong-Gon;Lee, Jae-Hong;Kim, Seong-Yoon;Kim, Heng-Jun J.;Kim, Nam-Kug;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.115-123
    • /
    • 2012
  • Purpose : To evaluate white matter abnormalities on diffusion tensor imaging (DTI) in patients with mild Alzheimer disease (AD) and mild cognitive impairment (MCI), using tract-based spatial statistics (TBSS) and voxel-based morphometry (VBM). Materials and Methods: DTI was performed in 21 patients with mild AD, in 13 with MCI and in 16 old healthy subjects. A fractional anisotropy (FA) map was generated for each participant and processed for voxel-based comparisons among the three groups using TBSS. For comparison, DTI data was processed using the VBM method, also. Results: TBSS showed that FA was significantly lower in the AD than in the old healthy group in the bilateral anterior and right posterior corona radiata, the posterior thalamic radiation, the right superior longitudinal fasciculus, the body of the corpus callosum, and the right precuneus gyrus. VBM identified additional areas of reduced FA, including both uncinates, the left parahippocampal white matter, and the right cingulum. There were no significant differences in FA between the AD and MCI groups, or between the MCI and old healthy groups. Conclusion: TBSS showed multifocal abnormalities in white matter integrity in patients with AD compared with old healthy group. VBM could detect more white matter lesions than TBSS, but with increased artifacts.

Lower Limbs Muscle Comparative Research for Verification Effect of Rehabilitation Training Program of Total Hip Arthroplasty (재활운동 프로그램에 참가한 엉덩인공관절 수술자의 하지근력 변화에 대한 비교연구)

  • Jin, Young-Wan
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.543-548
    • /
    • 2010
  • The purpose of this study was to examine the differences in kinetics between 6 months of rehabilitation training and 12 months of rehabilitation training after total hip arthroplasty. 10 unilateral THA participants performed kinetic tests. Three dimensional kinematics and hip flexors and abductors electromyography (EMG) were collected during each trial. T-test was used for statistical analysis (p<0.05). There was no significant difference in EMG data between the two groups, but the mean comparison EMG data was higher in the 12 months rehabilitation training group than the 6 months rehabilitation training group. The moment value was found with motion-dependent interaction analyzing method which was used by Feltner and Dapena. There was no significant difference between moment values of the two groups. There was no significant difference between ground reaction forces of the two groups; however, there were some differences shown in Fz (vertical reaction force) between the two groups ($892{\pm}104\;N$, $820{\pm}87\;N$). The first peak impact force was about 9% lower in the 12 months group compared to the 6 months group. The second peak active force was nearly equal between the two groups. More research is necessary to determine exactly what constitutes optimal rehabilitation training biomechanics for patients with total hip arthroplasty.

Association between Critical Thinking Disposition and Grade Point Average Score in Dental Hygiene Students (치위생(학)과 학생의 학업성적에 따른 비판적 사고 성향)

  • Hwang, Hye-Rim;Kim, Eung-Kwon;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.12 no.1
    • /
    • pp.7-13
    • /
    • 2012
  • Critical thinking is a essential competency for dental hygiene education and practice. The purpose of this study was to examine critical thinking disposition between groups classified by GPA score in two dental hygiene educational program. A total 252 dental hygiene students responded. The study extracted six dimensions(intellectual eagerness/curiosity, prudence, healthy skepticism, intellectual integrity, objectivity, self-confidence) derived from 27 items with the exception of systematicity using factor analysis. The mean score for critical thinking disposition was 3.47 on a 5 point scale. The result showed a statistically significant correlation critical thinking disposition and age. Multivariate analysis of covariance(MANCOVA) was used to compare six subscales between the three groups. MANCOVA results revealed that intellectual eagerness/curiosity for three groups were significantly different(Wilks's lamda=0.914, F(6, 24)=1.869), p=0.01, partial eta square=0.044). Multiple comparison for intellectual eagerness/curiosity by Scheffe's method showed differences between high score group and mid score group(p=0.027), high score group and low score group(p=0.002). In this study, academic achievement and critical thinking tends to show significant correlations is known. Critical thinking skills by examining the actual grade compares the difference in propensity scores according to a case study in intellectual curiosity, passion, and could tell the difference to appear.

A comparative study of electroplating and electroless plating for diameter increase of orthodontic wire (교정용 선재의 직경 증가를 위한 전기도금법과 무전해도금법의 비교연구)

  • Kim, Jae-Nam;Cho, Jin-Hyoung;Sung, Young-Eun;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.145-152
    • /
    • 2006
  • The purpose of this study was to evaluate electroless plating as a method of increasing the diameter of an orthodontic wire in comparison with eletroplating. After pretreatment plating of the 0.016 inch stainless steel orthodontic wire, electroless plating was performed at $90^{\circ}C$ until the diameter of the wire was increased to 0.018 inch. During the process of electroless plating, the diameter of the wire was measured every 5 minutes to examine the increasing ratio of the wire's diameter per time unit. And to examine the uniformity, the diameter at 3 points on the electroless-plated orthodontic wire was measured. An X-ray diffraction test for analyzing the nature of the plated metal and a 3-point bending test for analyzing the physical property were performed. The electroless-plated wire group showed a increased tendency for stiffness, yield strength, and ultimate strength than the electroplated wire group. And there was a statistically significant difference between the two groups for stiffness and ultimate strength. In the electroless-plated wire group, the increasing ratio of the diameter was $0.00461{\pm}0.00003mm/5min$ (0.00092 mm/min). In the electroplated wire group, it was $0.00821{\pm}0.00015mm/min$. The results of the uniformity test showed a tendency for uniformity in both the plating methods. The results of this study suggest that electroless plating of the wire is closer to the ready-made wire than electroplating wire in terms of the physical property. However, the length of plating time needs further consideration for the clinical application of electroless plating.

Comparison of Production Performances between Early- and Late-feathering Chickens in Parent Stocks of Korean Native Chicken (토종종계에 있어 조우성 개체와 만우성 개체간 생산능력 비교 고찰)

  • Kim, Ki Gon;Cho, Eun Jung;Choi, Eun Sik;Kwon, Jae Hyun;Jung, Hyun Chul;Sohn, Sea Hwan
    • Korean Journal of Poultry Science
    • /
    • v.46 no.4
    • /
    • pp.279-286
    • /
    • 2019
  • Currently, feather-sexing, which is based on differences in feather development at hatching, is a widely used chick sexing method in the poultry industry. For effective chicken feather-sexing, paternal early-feathering (EF) chickens and maternal late-feathering (LF) chickens must be bred. Therefore, it is critical to identify the effect of EF and LF patterns on production traits in chickens. Thus, the purpose of this study is to analyze and compare the production performances between 522 EF and 232 LF chickens in order to establish the Korean native chicken feather-sexing lines. The results showed that the survival rate of the LF group was significantly higher than that of the EF group from hatching to 52 weeks of age (P<0.05). Body weight, however, was not significantly different between the two groups at all ages. LF and EF groups did not significantly differ in age at first egg laying. However, the hen-day and hen-housed egg production of the LF group were significantly higher than those of EF group (P<0.01). No significant differences were found between the EF and LF groups in all egg quality indicators such as egg weight, eggshell color, albumin height and Haugh unit. Because the breeding target of Korean native commercial chicken is meat-type chicken, feather-sexing strains of Korean native chicken should be established using weighing-based paternal EF lines and laying-based maternal LF lines. Therefore, these results are critical for establishing desirable and effective feather-sexing strains.

Comparison of Single-Incision, Single-Bundle Posterior Cruciate Ligament Reconstruction Using Allograft Tendon (동종건을 이용한 단일 절개, 단일 다발 후방십자인대 재건술의 비교)

  • Kyung, Hee-Soo;Cheon, Sang-Ho;Park, Kyung-Hyun;Jung, Jae-Wook
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.107-113
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the posterior cruciate ligament (PCL) reconstruction with single bundle, single-incision technique using Achilles tendon and tibialis anterior allograft with ligament remnant preservation. Materials and Methods: Twenty six patients underwent PCL reconstruction was included. There were 21 males and 5 females. Mean age was 32 years. Used graft was a fresh frozen Achilles tendon allograft (group I, 14 cases) and tibialis anterior allograft (group II, 12 cases). Arthroscopic PCL reconstruction was performed using transtibial, single-incision and single bundle technique with remnant preserving as possible. For clinical evaluation, range of motion, posterior drawer test, Lysholm score, Tegner activity scale, International Knee Documentation Committee (IKDC) grade and posterior stress radiograph were used. The mean follow-up period was 21.6 months (12-40 months). Associated injuries were 5 medial collateral ligament injuries, which were treated by conservative method. Results: Range of motion (ROM) was returned to normal range in 24 cases, but ROM deficit under $10^{\circ}$ flexion was 2 cases at final follow-up period. Preoperative posterior drawer test was 17 cases in grade II and 9 cases in grade III. At final follow-up 13 cases returned within normal grade, 7 cases grade I and 6 cases grade II posterior instability. Lysholm mean score was improved from preoperatively 62 to 90 at final follow-up period. Tegner activity mean scale improved from preoperatively 3.5 to 5.6 at final follow-up period. IDKC grade was grade A was 3 cases, grade B 17 cases, grade C 6 cases. In posterior stress radiograph, posterior displacement was improved from mean 12 mm preoperative to 4.5 mm at final follow-up. There were no statistical differences between two groups in clinical evaluations. There were two cases of re-rupture of graft at the bone-tendon junction in group I. Conclusion: We had successful results of PCL reconstruction with single-incision, single bundle technique using Achilles and tibialis anterior allograft without difference between two groups in patients with PCL injury. There were more re-rupture of graft in Achilles tendon group.

  • PDF

THE COMPARISON OF RELATIVE RELIABILITY ON BIAXIAL AND THREE POINT FLEXURAL STRENGTH TESTING METHODS OF LIGHT CURING COMPOSITE RESIN (광중합형 레진의 3점 굴곡 강도와 이축 굴곡 강도 측정 방법에 대한 상대적 신뢰도의 비교)

  • Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.58-65
    • /
    • 2006
  • The possibility of applying a hi-axial flexure strength test on composite resin was examined using three point and hi-axial flexure strength tests to measure the strength of the light-cured resin and to compare the relative reliability using the Weibull modulus. The materials used in this study were light-curing restorative materials, $MICRONEW^{TM},\;RENEW^{(R)}$ (Bisco, Schaumburg, USA). The hi-axial flexure strength measurements used the piston-on-3-ball test according to the regulations of the International Organization for Standardization (ISO) 6872 and were divided into 6 groups, where the radius of the specimens were 12mm (radius connecting the 3-balls: 3.75mm), 16 mm(radius connecting the 3-balls: 5mm), and the thickness were 0.5mm, 1mm, 2mn for each radius. The hi-axial flexure strength of the $MICRONEW^{TM}\;and\;RENEW^{(R)}$ were higher than the three point flexure strength and the Weibull modulus value were also higher in all of the bi-axial flexure strength groups, indicating that the hi-axial strength test is relatively less affected by experimental error. In addition, the 2 mm thick specimens had the highest Weibull modulus values in the hi-axial flexure strength test, and the $MICRONEW^{TM}$ group showed no significant statistical difference (p>0.05). Besides the 2mm $MICRONEW^{TM}$ group, each group showed significant statistical differences (p<0.05) according to the thickness of the specimen and the radius connecting the 3-balls. The results indicate that for the 2mm group, the hi-axial flexure strength test is a more reliable testing method than the three point flexure strength test.