• 제목/요약/키워드: Comparison of efficiency

검색결과 3,230건 처리시간 0.037초

이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 - (A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor -)

  • 우인성;;황명환
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

전탕방법에 따른 전탕액의 추출률 비교연구 - 평위산 전탕액의 Hesperidin HPLC 분석 - (Comparative Study of Extraction Efficiency of Water Decoction with or Without Non-woven Fabric)

  • 양웅모;정규진;김경욱;배현수;장문석;박성규
    • 대한본초학회지
    • /
    • 제25권1호
    • /
    • pp.9-12
    • /
    • 2010
  • Objectives : To evaluate the extraction efficiency of water decoction with or without non-woven fabric underlying comparison of the HPLC (high-performance liquid chromatography) profiles of the hesperidin which is the standard of Citri Pericarpium. Methods : Pyungwisan, which is comprised of Atractylodis Rhizoma, Magnoliae Cortex, Citri Pericarpium, Glycyrrhizae Radix, Zingiberis Rhizoma, and Ziziphy Fructus, was extracted in boiling water with non-woven fabric or without non-woven fabric. Then hesperidin content was analyzed by HPLC. Results : The contents of hesperidin in the water extract of Pyungwisan which was decocted without non-woven fabric showed $219.57{\pm}2.51\;mg/g$ and $138.90{\pm}6.32\;mg/g$ in with non-woven fabric decoction. Conclusions : These results suggest that herbal decoction without non-woven fabric might increase extraction efficiency.

제설제가 환경에 미치는 영향 연구 (A study of effects on environment from road deicings)

  • 신진호;허항록;신정식;김민영;신재영
    • 환경위생공학
    • /
    • 제16권4호
    • /
    • pp.31-37
    • /
    • 2001
  • Deicers have used for melting snow on the road during winter season, but they have largely influenced on environment and public assets and human health. The pollution level of snow and soil contained deicer was analyzed and evaluated the characteristics of deicers. The results were as follows 1. In the result of measurement of pollutants in snow contained deicer, the pH was a little higher than a comparative group and the concentration of $Cl^{-}$ ranged from 0.5% to 0.87%, and the electric conductivity ranged 12.4 to 24.6 mmho/cm. The concentration of Cd, As, and Hg was not detected, but those of Cu, Pb, Cr was higher than a comparative group. 2. In soil of the road spreaded with deicer, the pH is getting alkalized and the concentration of $Cl^{-}$ was high in January and returned the level of a comparative grout) in November by physical and chemical reaction with deicer, but the concentration of heavy metals were not connected with deicers. 3. In comparison of deicing efficiency, the concentration of $Cl^{-}$ was 3.3~5times high in spreading with deicer before snowing than after snowing. The concentration of $Cl^{-}$ in NaCl was higher than $CaCl_2$, but the deicing efficiency of Nacl was better than that of $CaCl_2$. Moreover, the new deicer have no salt, but deicing efficiency of new deicer was less than that of NaCl and $CaCl_2$.

  • PDF

Comparison of Circuit Reduction Techniques for Power Network Noise Analysis

  • Kim, Jin-Wook;Kim, Young-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권4호
    • /
    • pp.216-224
    • /
    • 2009
  • The endless scaling down of the semiconductor process made the impact of the power network noise on the performance of the state-of-the-art chip a serious design problem. This paper compares the performances of two popular circuit reduction approaches used to improve the efficiency of power network noise analysis: moment matching-based model order reduction (MOR) and node elimination-based MOR. As the benchmarks, we chose PRIMA and R2Power as the matching-based MOR and the node elimination-based MOR. Experimental results indicate that the accuracy, efficiency, and memory requirement of both methods very strongly depend on the structure of the given circuit, i.e., numbers of the nodes and sources, and the number of moments to preserve for PRIMA. PRIMA has higher accuracy in general, while the error of R2Power is also in the acceptable range. On the other hand, PRIMA has the higher efficiency than R2Power, only when the numbers of nodes and sources are small enough. Otherwise, R2Power clearly outperforms PRIMA in efficiency. In the memory requirement, the memory size of PRIMA increases very quickly as the numbers of nodes, sources, and preserved moments increase.

이종 전극에 의한 OLED 전기적 특성 연구 (Electrical Characteristics of OLED using the Hetero-Electrode)

  • 이정호;서정하;정지훈;김영관;김영식;김영찬
    • 한국응용과학기술학회지
    • /
    • 제21권4호
    • /
    • pp.274-278
    • /
    • 2004
  • In this study, hetero-electrode structures have been fabricated to increase luminescence efficiency. The presence of a thin layer of Sn or Ag at the organic-aluminum interface enhanced both electron injection efficiency and electroluminescence when compared to OLEDs using homogeneous electrode. In this paper, the effect of the cathode using Sn/Al hetero electrode structure is observed. Electric properties of the OLED using Sn/Al hetero cathode are improved in comparison of only Al cathode. The hetero-electrode existing different energy level induces the advanced structure of OLED can accumulate electron density. The luminescence efficiency of OLED with Sn/Al of Ag/Al cathode is higher because of their higher electron injection efficiency. And, the turn on voltage of the OLED device using Sn thin layer is lowest as about 10 V.

Comparison of the effects of zinc oxide and zinc aspartic acid chelate on the performance of weaning pigs

  • Sarbani Biswas;De Xin Dang;In Ho Kim
    • Journal of Animal Science and Technology
    • /
    • 제66권1호
    • /
    • pp.125-134
    • /
    • 2024
  • In this research, the growth efficiency, nutritional utilization, fecal microbial levels, and fecal score of weaned pigs were evaluated using therapeutic zinc oxide (ZnO) and zinc aspartic acid chelate (Zn-Asp). In a 42-day feeding trial, 60 weaned pigs ([Yorkshire × Landrace] × Duroc) were arbitrarily allotted (age: 21 days; 7.01 ± 0.65 kg preliminary body weight) to 3 different treatment groups with 5 repetitions (2 male and 2 female piglets) in each pen. The trial had 2 different phases, including 1-21 days as phase 1, and 22-42 days as phase 2. The nutritional treatments were: basal diet as control (CON), basal diet incorporated with 3,000 ppm ZnO as TRT1, and basal diet incorporated with 750 ppm Zn-Asp as TRT2. In comparison to the CON group, the pigs in the TRT1 and TRT2 groups had greater (p < 0.05) body weight on day 42; an average daily gain, and an average daily feed intake on days 22-42. Furthermore, during days 1-42, the average daily gain in the treatment groups trended higher (p < 0.05) than in the CON group. Additionally, the fecal score decreased (p < 0.05) at week 6, the lactic acid bacteria count tended to increase (p < 0.05), and coliform bacteria presented a trend in reduction (p < 0.05) in the TRT1 and TRT2 groups compared to the CON group. However, there was no difference in nutrient utilization (p > 0.05) among the dietary treatments. Briefly, the therapeutic ZnO and Zn-Asp nutritional approaches could decrease fecal score and coliform bacteria, increase lactic acid bacteria, and improve growth efficiency; moreover, Zn-Asp (750 ppm) can perform a comparable role to therapeutic ZnO (3,000 ppm). So we can use Zn-Asp (750 ppm) instead of therapeutic ZnO (3,000 ppm) for the better performance of weaning pigs and the reduction of environmental pollution, as therapeutic ZnO is responsible for environmental pollution.

전기화학형 광전변환 셀의 고효율 전해질 제작에 관한 실험적 고찰 (Experimental Investigation on High Efficient Electrolytes of Electrochemical Photovoltaic Cells)

  • 김두환;한치환;성열문
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.100-104
    • /
    • 2011
  • In this work, an optimum condition of electrolytes preparation for photovoltaic cells application was investigated experimentally in terms of impedance and conversion efficiency of the cells. 3-methoxyppropionitrie and redox pairs with LiI and $I_2$ were used as stable solvents for fabrication of electrolyte. Efficiency comparison of the prepared cells carried out for various additives and ionic liquids. From the results, there was an optimum concentration (about 0.3 M) of ionic liquids for efficient cell fabrication. For case of electrolyte using single DMAp additive, the maximum conversion efficiency of the cell was 6.4%($V_{oc}$: 0.78V, $J_{sc}$: 14.4 mA/$cm^2$, ff: 0.57). For case of electrolyte using both DMAp and CEMim additives, the maximum conversion efficiency of the cell was 7.2%($V_{oc}$: 0.79V, $J_{sc}$: 16 mA/$cm^2$, ff: 0.57). From the result of electrochemical impedance measurement, both Z1 and Z3 values of binary additives-based cell decreased compared to those of single additive-based. This is due to the decreased in internal and charge transfer resistivities of the cells.

줄눈형식에 따른 공항 콘크리트 포장 하중전달율 비교 (Comparison with Load Transfer Efficiency for Joint Types in Airport Concrete Pavements)

  • 안지환;전성일;권수안;김민우
    • 한국도로학회논문집
    • /
    • 제16권3호
    • /
    • pp.9-20
    • /
    • 2014
  • PURPOSES : This study is to compare load transfer efficiency of key joint and dowel joint for airport concrete pavement. METHODS : As AC150/5320-6D of FAA's [Advisory Circular] was changed into AC150/5320-6E, Key joint type of rigid pavement were excluded from Construction Joints. LTE(Load Transfer Efficiency) of dowel joint and key joint were compared by times and seasons through pavement temperature measurement, ocular investigation and HWD measurement. RESULTS : For the joint performance grade of No. 2(The second) runway of airport, 12% of poor rate was observed in key joint and 2% of poor rate in dowel joint. Poor rate of key joint was increased to 17%, if only No. 3~No. 6 slabs, which are mostly loaded from the airplanes, were applied for the study. In apron area, LTE poor rate of key joint was high in winter, and LTE poor rate of dowel joint was at least above 'Fair' grade. In summer, 'Fair' for key joint, 'Acceptable' for dowel joint appeared. CONCLUSIONS : As results, dowel joint was superior than key joint for LTE. Deviations of seasons and times were smaller in dowel joint's result. And LTE in winter was lower than LTE in summer.

주석 페로브스카이트 태양전지에 관한 고찰: 재료 및 장치적 특성 (Review on Tin Perovskite Solar Cells: Material and Device Properties)

  • 최다영;임세영;김한결
    • Current Photovoltaic Research
    • /
    • 제11권1호
    • /
    • pp.18-26
    • /
    • 2023
  • Tin perovskite solar cells have attracted a lot of attention due to their potential to address the toxicity of lead, which is the biggest barrier to commercialization of perovskite solar cells. Unlike other lead-free perovskite, tin perovskite have a direct bandgap, which is suitable for use as light harvesting, and relatively good stability, which has led to a lot of attention. Since the first tin perovskite solar cell was reported in 2014, it has achieved an impressive power conversion efficiency of 14.81%. However, this efficiency is still low compared to that of lead perovskite solar cells, and the stability of tin perovskite solar cells is also an issue that needs to be addressed. In this review, we will discuss the basic properties of the tin atom in comparison to the lead atom, and then discuss the crystal structure, phase transition, and basic properties of tin perovskite. We will then discuss the advantages, applications, challenges, and strategies of tin perovskite, In particular, we will focus on how to prevent the oxidation of tin, which is arguably the biggest challenge for using tin perovskite solar cells. At the end, we summarize the key factors that need to be addressed for higher efficiency and stability, emphasizing what is needed to commercialize tin perovskite solar cells.

기어 물림 상태의 타행 주행 저항을 이용한 엔진 운전 조건의 분석 (Analysis of Engine Operation Condition by Using Coastdown Test under Gear Engaged Condition)

  • 심범주;박경석;박준수;민병두
    • 한국자동차공학회논문집
    • /
    • 제20권6호
    • /
    • pp.61-66
    • /
    • 2012
  • Conventional method to transform vehicle driving condition to engine operation mode is to use vehicle road load under neutral gear and mechanical efficiency of drivetrain. But this method requires additional measurement of efficiency of drivetrain on a test rig. And this measurement is normally done at fixed speed and thus estimated accuracy of engine operation mode is not considered to be high enough. This study suggests new method to calculate engine operation mode for prescribed driving mode such as NEDC using vehicle coastdown test under gear engaged condition without measurement of mechanical efficiency of drivetrain. Coastdown test was done under neutral and gear engaged condition for comparison and also trial to extract mechanical loss of drivetrain was carried out. Calculated engine torque by conventional and newly suggested method was compared with actually measured torque of a vehicle on a chassis dynamometer during NEDC. Newly suggested method showed slightly higher accuracy of accumulated brake work during NEDC.