• Title/Summary/Keyword: Compare between Korea and USA

Search Result 70, Processing Time 0.029 seconds

Change in the Concentration of Fine Particles, Temperature, and Relative Humidity as Affected by Different Volume Ratios of Interior Greening in Real Indoor Space (실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향)

  • Ju, Jin-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • The study objective was to compare the interior greening volume ratios for the change in concentration of fine particle, temperature and relative humidity, and to identify the level of interior landscape volume ratio as a suitable condition to achieve the desired indoor properties. Plants were moved into a room (88m3) randomly. After moving, the volume ratio of the interior greening level was set at 0%, 1%, 2% and 3%. The concentration of fine particles was measured with a mini-volume portable air sampler (Air Metrics, USA). The temperature and relative humidity were recorded with a digital sensor (Kiwi-LTH, USA) during the experiment under different volume ratios with three replications. 1. The results of the change in concentration of the fine particles revealed a trend towards an increased volume ratio of interior greening with decreasing concentration of fine particles, compared to non-plants (0%). The concentration of fine particles at volume ratios of 0%, 1%, 2% and 3% was 55ug/$m^3$, 233ug/$m^3$, 40ug/$m^3$ and 30ug/$m^3$, respectively. 2. The change in temperature, at volume ratios of 0%, 1%, 2% and 3% was $21.2^{\circ}C$, $17.4^{\circ}C$, $16.7^{\circ}C$ and $18.9^{\circ}C$, respectively, in near interior greening, and $22.1^{\circ}C$, $18.7^{\circ}C$, $18.4^{\circ}C$ and $20.5^{\circ}C$ respectively, at a distance of 3m from the interior greening. These study results suggested that temperature was affected by volume ratio and distance from the interior greening. 3. The relative humidity, at volume ratios of 0%, 1%, 2% and 3% was 34.2%, 32.5%, 36.7%, and 46.9%, respectively, in near interior greening, and 31.2%, 26.9%, 31.4% and 38.3%, respectively, at a distance of 3m from the interior greening. With increasing volume ratio of interior landscape, there were positive and significant results between the distance difference and the relative humidity more than temperature.

Effect of loading time on marginal bone loss around hydroxyapatite-coated implants

  • Kim, Young-Kyun;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Minkyoung;Yang, Hong-So;Yi, Yang-Jin;Bae, Ji-Hyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.161-167
    • /
    • 2013
  • Objectives: The objective of this study is compare the rate of marginal bone resorption around hydroxyapatite-coated implants given different loading times in order to evaluate their stability. Materials and Methods: The study was conducted retrospectively for one year, targeting 41 patients whose treatment areas were the posterior maxilla and the mandible. Osstem TS III HA (Osstem Implant Co., Busan, Korea) and Zimmer TSV-HA (Zimmer Dental, Carlsbad, CA, USA), which employ the new hydroxyapatite coating technique, were used. The patients were divided into two groups - immediate and delayed loading - and the bone level at the time of loading commencement and after one year of loading was measured using periapical radiography. Differences between the groups were evaluated using Mann-Whitney (${\alpha}$=0.05). Results: For all patients as a single group, the survival rate of the implants was 100%, and the mean marginal bone loss was $0.26{\pm}0.59mm$. In comparison of the differences by loading, mean marginal bone loss of $0.32{\pm}0.69mm$ was recorded for the immediate loading group whereas the delayed loading group had mean marginal bone loss of $0.16{\pm}0.42mm$. However, the difference was not significant (P>0.05). Conclusion: Within the limited observation period of one year, predictable survival rates can be expected when using immediately loaded hydroxyapatite-coated implants.

Comparison of optical reflectance spectrum at blade and vein parts of cabbage and kale leaves

  • Ngo, Viet-Duc;Ryu, Dong-Ki;Chung, Sun-Ok;Park, Sang-Un;Kim, Sun-Ju;Park, Jong-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • Objective of the study was to compare reflectance spectrum in the blade and the vein parts of cabbage and kale leaves. A total 6 cabbage and kale leaves were taken from a plant factory in Chungnam National University, Korea. Spectra data were collected with a UV/VIS/NIR spectrometer (model: USB2000, Ocean Optics, FL, USA) in the wavelength region of 190 - 1130 nm. Median filter smoothing method was selected to preprocess the obtained spectra data. We computed reflectance difference by subtraction of averaged spectrum from individual spectrum. To estimate correlation at different parts of cabbage and kale leaves, cross - correlation method was used. Differences between cabbage and kale leaves are clearly manifested in the green, red and near - infrared ranges. The percent reflectance of cabbage leaves in the NIR wavelength band was higher than that of kale leaves. Reflectance in the blade part was higher than in the vein part by 18%. Reflectance difference in the different parts of cabbage and kale leaves were clear in all of the wavelength bands. Standard deviation of reflectance difference in the vein part was greater for kale, while the value in the blade part was greater for cabbage leaves. Standard deviation of cross - correlation increased from 0.092 in the first sensor (UV/VIS) and 0.007 in the second sensor (NIR) to 0.099 and 0.015, respectively.

Standard Curve Validation using Trendlines in Excel (Excel의 추세선을 이용한 표준곡선 검증)

  • Lee, Kyung-Hwa;Park, Hyung-Ki;Shin, Young-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Purpose Using a regression formula of the trendline near the coefficient of determination (R2) "1" by substituting the dependent variable of the standard curve to calculate the values of the independent variable. To determine the suitability of a regression equation by comparing the difference between the independent variables of the standard curve and the predicted independent variables. Materials and Methods Perkin Elmer Gamma-Counter machine was used for Standard curve of regression methods. TSH. TG-Ag (Thyroglobulin Antigen), Insulin that used materials and method test to compare the result from the Excel trendline of the regression formula. Results Each of the value of coefficient of determination ($R^2$) and Trendline $R^2=1$, Polynomial Trendline for TSH, $R^2=1$, Polynomial Trendline for TG-Ag, $R^2=0.9994$, Polynomial Trendline for Insulin. Conclusion We confirmed that IRMA immune method is found to the nearest trends elected a standard curve using polynomial trendline. The independent variables to predict the trend by using a polynomial trendline formula containing the error was a limitation.

  • PDF

Evaluation of the $HApS^{TM}$ Method for the Enumeration of Aerobic Microorganisms and Coliforms in Retailed Meat Samples in Korea

  • Keun-Seok Seo;Wonki Bae;So-Hyun Kim;Nam-Hoon Kwon;Ji-Yeun Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.194-199
    • /
    • 2001
  • This study was designed to compare the effectiveness and applicability of the HApS$^{TM}$ (Hazard Analysis process System; HUKO, Seoul, Korea) based on Petrifilm$^{TM}$ (3M, St. Paul, MN, USA) with the AOAC (the Association of Official Analytical Chemists) standard total aerobic count (TAC) method and coliform count (CC) method for meat products. The comparisons were carried out using 230 meat samples collected from various retailers: 80 pork samples, 80 chicken samples, and 70 beef samples. In the comparison of the correlation coefficient (r) between conventional method and HApS$^{TM}$ method by a linear regression analysis, the correlation coefficients in total microorganism were 0.97767, 0.90712, and 0.95594 in pork, beef, and chicken samples, respectively. The correlation coefficients in coliform count were 0.82062, 0.94833, and 0.96839 in pork, beef and chicken samples, respectively. All the independent t-test on measurement values between conventional method and HApS$^{TM}$ method represented no significant differences in the means between two methods at the 0.05 of significance level($\alpha$=0.05). Based on the high correlation between HApS$^{TM}$ and the AOAC standard methods in the TAC and CC, it might be compatible to employ the HApS$^{TM}$ method to measure the microbial contamination in livestock products. HApS$^{TM}$ method was simpler and less time-consuming in sample preparation and procedures faster than the conventional method. These results suggested that the HApS$^{TM}$ method could be substitute for the conventional methods in the analysis of microbial contamination measurement in meat products.n meat products.

  • PDF

Dietary Copper Intakes and Nutritional Status of Copper in Serum among Elementary Schoolchildren in Chungnam Province in Korea: Comparison between Remote Rural and Urban Areas (일부 학령기 아동의 구리 섭취량 및 구리 영양 상태에 관한 연구: 충남 벽지농촌과 도시간의 비교)

  • Kim Sun-Hyo
    • Journal of Nutrition and Health
    • /
    • v.39 no.4
    • /
    • pp.381-391
    • /
    • 2006
  • This study is performed to compare the dietary intakes and food sources of copper (Cu) using the database of Cu content developed in this study between the elementary schoolchildren in remote rural areas (RA, n=58, $9.9{\pm}1.7$ yrs) and those in urban area (UA, n=60, $9.4{\pm}1.8$ yrs), and to analyze the relationship between serum Cu concentration and serum antioxidant status in the RA. The results obtained in this study were as followings: 1) Dietary intakes of calorie, calcium and iron in the RA were in the 3/5-4/5 of the Korean RDA while the UA were similar to or more than the Korean RDA, 7th ed. except iron. 2) More than 273 kinds of food consumed by the subjects were analyzed the content of Cu and database of Cu content were developed in the present study. The mean dietary intake of Cu per day in the RA was $0.99{\pm}0.07mg/d$ ($170.0{\pm}13.2%$ of the USA RDA) while it was $1.22{\pm}0.07mg/d$ ($203.4{\pm}13.1%$ of the RDA) in the UA. The percentage of dietary intakes of Cu less than 213 of the RDA was 8.6% in the RA in comparison to 0% in the UA. 3) The RA and the UA consumed more than 80% of total dietary intakes of Cu from plant foods. Thus, the RA and the UA consumed Cu from cooked rice, vegetables and fruits as a major source. However the RA had less Cu from meat and their products than did the UA (p<0.05) .4) Crab stew including crab and juice was the highest food source of Cu for the total subjects, followed by seasoned bud of aralia, cooked; beef rib meat, roasted; soybean paste soup w/mallow; and soybean paste soup w/mallow & beef. Major food source of Cu was similar for the RA and the UA such as cooked rice, vegetables and fruits. 5) Mean concentration of serum Cu in the RA was $18.1{\pm}0.7{\mu}M/L$ that was in the normal value, and all subjects in this group were in more than normal value. In the RA serum Cu concentration related positively with serum ceruloplasmin concentration, serum vitamin C concentration and EC SOD activity, respectively. However, serum Cu concentration did not relate with serum TBARS concentration in the RA. Above results showed that the RA had good status of Cu nutrition based upon dietary intake and serum concentration, however some of the RA had lower intake of Cu than the RDA. The overall children in the UA had good Cu nutrition. Therefore, the subgroup of the RA should be supported to improve their Cu nutrition, and this support could give them better antioxidant status based upon positive relationship between serum Cu concentration and serum antioxidant status in the RA.

Histomorphometric Study of Sinus Bone Graft using Various Graft Material (다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가)

  • Lee, Ji-Young;Kim, Young-Kyun;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • The aim of this study was to evaluate histomorphometrically and compare the efficiency of various bone graft material and autogenous tooth bone graft material which were used in sinus bone graft procedure. Subjects were the 24 patients who had treated with sinus bone graft using lateral approach from October 2007 to September 2009 at SNUBH. The average age was $52.51{\pm}11.86$ years. All cases was taken after 4month of procedure and divided into 3 groups according to bone graft material. Group 1: autogenous tooth bone graft material, Group 2: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), group 3: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). Total 37 implant placement area were included and evaluated(7 in group 1, 10 in group 2, 20 in group 3). Evaluation of new bone formation, ratio of woven bone to lamellar bone, ratio of new bone to graft material were performed on each tissue section. Kruskal-Wallis test was used for statistical analysis(SPSS Ver. 12.0, USA). New bone formation were $52.5{\pm}10.7%$ in group 1, $52.0{\pm}23.4%$ in group 2, $51.0{\pm}18.3%$ in group 3. There were no statistical significant differences between each groups. Ratio of woven bone to lamella bone were $82.8{\pm}15.3%$ in group 1, $36.7{\pm}59.3%$ in group 2, $31.0{\pm} 51.2%$ in group 3. Ratio of new bone to graft material were $81.3{\pm}10.4%$ in group 1, $72.5{\pm}28.8%$ in group 2, $80.3{\pm}24.0%$ in group 3. After 4 month of healing period, all group showed favorable new bone formation and around graft material and implant. Within limitation of our study, it is suggested that autogenous tooth bone graft material might be used as novel bone graft material for sinus bone graft.

WEAR AND CHEMICAL DEGRADATION OF ESTHETIC RESTORATIVE MATERIALS (차세대 레진 개발을 위한 광중합형 복합레진의 화학적 분해와 마모에 관한 연구)

  • Yang, Kyu-Ho;Choi, Eun-Young;Choi, Nam-Ki;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.557-568
    • /
    • 2005
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four esthetic restorative materials in an alkaline solution(0.1N NaOH). The brands studied were MetafilCX(Sun medical, Japan) Solitaire 2(Heraeus Kulzer, USA), Composan LCM(Promedica, Germany), DenFil(Vericom, Korea). The results were as follows: 1. The mass loss of each brand was 0.74~7.94% and highest value in Metafil($7.94{\pm}0.39%$). 2. The sequence of the degree of degradation layer depth was in descending order by Metafil, Solitaire 2, DenFil, Composan LCM. There were significant differences between Metafil and the others(p<0.05). 3. The sequence of the Si loss was in descending order by Metafil, Solitaire 2, Composan LCM, DenFil. There were significant differences among the materials(p<0.05). 4. On SEM, destruction of bonding between matrix and filler and on CLSM, the depth of degradation layer of specimen surface was observed. 5. The sequence of maximum wear depth was in descending order by Metafil, Solitaire 2, Composan LCM and DenFil. There were significant differences among the materials(p<0.05). 6. The correlation coefficient between Si loss and degradation layer depth (r=0.491, p<0.05) and Vicker's hardness number and maximum wear depth (r=-0.942, p<0.05) were relatively high. These results indicate that hydrolytic degradation and wear may consider as a evaluation factors of composite resins.

  • PDF

Study on the Application of 2D Video Disdrometer to Develope the Polarimetric Radar Data Simulator (이중편파레이더 시뮬레이터 개발을 위한 2차원 영상우적계 관측자료의 활용가능성 연구)

  • Kim, Hae-Lim;Park, Hye-Sook;Park, Hyang Suk;Park, Jong-Seo
    • Atmosphere
    • /
    • v.24 no.2
    • /
    • pp.173-188
    • /
    • 2014
  • The KMA has cooperated with the Oklahoma University in USA to develop a Polarimetric Radar Data (PRD) simulator to improve the microphysical processes in Korea Local Analysis and Prediction System (KLAPS), which is critical for the utilization of PRD into Numerical Weather Prediction (NWP) field. The simulator is like a tool to convert NWP data into PRD, so it enables us to compare NWP data with PRD directly. The simulator can simulate polarimetric radar variables such as reflectivity (Z), differential reflectivity ($Z_{DR}$), specific differential phase ($K_{DP}$), and cross-correlation coefficient (${\rho}_{hv}$) with input of the Drop Size Distribution (DSD) and scattering calculation of the hydrometeors. However, the simulator is being developed based on the foreign observation data, therefore the PRD simulator development reflecting rainfall characteristics of Korea is needed. This study analyzed a potential application of the 2-Dimension Video Disdrometer (2DVD) data by calculating the raindrop axis ratio according to the rain-types to reflect Korea's rainfall characteristics into scattering module in the simulator. The 2DVD instrument measures the precipitation DSD including the fall velocity and the shape of individual raindrops. We calculated raindrop axis ratio for stratiform, convective and mixed rainfall cases after checking the accuracy of 2DVD data, which usually represent the scattering characteristics of precipitation. The raindrop axis ratio obtained from 2DVD data are compared with those from foreign database in the simulator. The calculated the dual-polarimetric radar variables from the simulator using the obtained raindrop axis ratio are also compared with in situ dual-polarimetric observation data at Bislsan (BSL). 2DVD observation data show high accuracies in the range of 0.7~4.8% compared with in situ rain gauge data which represents 2DVD data are sufficient for the use to simulator. There are small differences of axis ratio in the diameter below 1~2 mm and above 4~5 mm, which are more obvious for bigger raindrops especially for a strong convective rainfall case. These differences of raindrop axis ratio between domestic and foreign rainfall data base suggest that the potential use of disdrometer observation can develop of a PRD simulated suitable to the Korea precipitation system.

Comparison of Biomechanical Characteristics for the Skill Level in Cycle Pedaling

  • Lee, Geun-Hyuk;Kim, Jai-Jeong;Kang, Sung-Sun;Hong, Ah-Reum;So, Jae-Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • Objective: This study aimed to compare biomechanical data between elite and beginner cyclists during cycle pedaling by performing a comparative analysis and to provide quantitative data for both pedaling performance enhancement and injury prevention. Methods: The subjects of this study included 5 elite cyclists (age: $18{\pm}0years$, body mass: $64.8{\pm}9.52kg$, height: $173.0{\pm}4.80cm$) and 5 amateur cyclists (age: $20{\pm}0years$, mass: $66.6{\pm}2.36kg$, height: $175.6{\pm}1.95cm$). The subjects pedaled on a stationary bicycle mounted on rollers of the same gear (front: 50 T and rear: 17 T = 2.94) and cadence of 90. The saddle height was adjusted to fit the body of each subject, and all the subjects wore shoes with cleats. In order to obtain kinematic data, 4 cameras (GR-HD1KR, JVC, Japan) were installed and set at 60 frames/sec. An electromyography (EMG) system (Telemyo 2400T, Noraxon, USA) was used to measure muscle activation. Eight sets of data from both the left and right lower extremities were obtained from 4 muscles (vastus medialis oblique [VMO], vastus lateralis oblique [VLO], and semitendinosus [Semitend], and lateral gastrocnemius [Gastro]) bilaterally by using a sampling frequency of 1,500 Hz. Five sets of events ($0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, and $360^{\circ}$) and 4 phases (P1, P2, P3, and P4) were set up for the data analysis. Imaging data were analyzed for kinematic factors by using the Kwon3D XP computer software (Visol, Korea). MyoResearch XP Master Edition (Noraxon) was used for filtering and processing EMG signals. Results: The angular velocity at $360^{\circ}$ from the feet was higher in the amateur cyclists, but accelerations at $90^{\circ}$ and $180^{\circ}$ were higher in the elite cyclists. The amateur cyclists had greater joint angles at $270^{\circ}$ from the ankle and wider knee joint distance at $0^{\circ}$, $180^{\circ}$, and $360^{\circ}$ than the elite cyclists. The EMG measurements showed significant differences between P2 and P4 from both the right VLO and Semitend. Conclusion: This study showed that lower body movements appeared to be different according to the level of cycle pedaling experience. This finding may be used to improve pedaling performance and prevent injuries among cyclists.