• 제목/요약/키워드: Compact bone

검색결과 71건 처리시간 0.026초

치성 및 비치성 조직이 악골 창상치유에 미치는 영향에 관한 실험적 연구 (THE EFFECTS OF ODONTOGENIC AND NONODONTOGENIC TISSUES ON BONE HEALING IN GUINEA PIG MANDIBLE)

  • 김소정;황의환;이상래;홍정표
    • 치과방사선
    • /
    • 제26권2호
    • /
    • pp.33-44
    • /
    • 1996
  • This study was for comparing healing patterns and effects between with odontogenic and nonodontogenic tissues on the defected mandible. Experimental bone defects that measured 3 mm in diameter were created on the mandibular body of guinea pig by removal of bone with the use of trephine burs and bone defects were grafted with Biogran(Orthovita Co., U.S.A.) and covered with Dura Mata(Pfrimmer-Viggo GmbH Co., Germany). Guinea pigs were serially terminated by fours on the 3 days, the 1 week, the 2 weeks, the 3 weeks, the 4 weeks, and the 5 weeks after experiment, and the mandibular body was removed and fixed with 10% neutral formalin. They were decalcified and embedded in paraffin as using the usual methods. The specimen sectioned and stained with hematoxylin and eosin and toluidine blue. They were observed with a light microscope and a polarizing microscope. The obtained results were as follows : 1. Defected bone was healed fast from the odontogenic tissues in early stage of the experiment. 2. The arrangement of the bone matrix was relatively regular in the bone from the nonodontogenic tissues, but irregular in the bone from the odontogenic tissues. 3. Compact bone has started to be resorbed and changed to the pattern of matrix bone tissue from 3 weeks after experiment.

  • PDF

THE EFFECT OF THE BIORESORBABLE COLLAGEN MEMBRANE ON THE REGENERATION OF BONE DEFECT BY USING THE MIXTURE OF AUTOGRAFT AND XENOGRAFT BONE

  • Lee Jung-Min;Kim Yung-Soo;Kim Chang-Whe;Han Jung-Suk
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.325-341
    • /
    • 2003
  • Statement of problem: In cases where bony defects were present, guided bone regenerations have been performed to aid the placement of implants. Nowadays, the accepted concept is to isolate bone from soft tissue by using barrier membranes to allow room for generation of new bone. Nonresorbable membranes have been used extensively since the 1980's. However, this material has exhibited major shortcomings. To overcome these faults, efforts were made to develop resorbable membranes. Guided bone regenerations utilizing resorbable membranes were tried by a number of clinicians. $Bio-Gide^{(R)}$ is such a bioresorbable collagen that is easy to use and has shown fine clinical results. Purpose: The aim of this study was to evaluate the histological results of guided bone regenerations performed using resorbable collagen membrane($Bio-Gide^{(R)}$) with autogenous bone, bovine drived xenograft and combination of the two. Surface morphology and chemical composition was analyzed to understand the physical and chemical characteristics of bioresorbable collagen membrane and their effects on guided bone regeneration. Material and methods: Bioresorbable collagen membrane ($Bio-Gide^{(R)}$), Xenograft Bone(Bio-Oss), Two healthy, adult mongrel dogs were used. Results : 1. Bioresorbable collagen membrane is pure collagen containing large amounts of Glysine, Alanine, Proline and Hydroxyproline. 2. Bioresorbable collagen membrane is a membrane with collagen fibers arranged more loosely and porously compared to the inner surface of canine mucosa: This allows for easier attachment by bone-forming cells. Blood can seep into these spaces between fibers and form clots that help stabilize the membrane. The result is improved healing. 3. Bioresorbable collagen membrane has a bilayered structure: The side to come in contact with soft tissue is smooth and compact. This prevents soft tissue penetration into bony defects. As the side in contact with bone is rough and porous, it serves as a stabilizing structure for bone regeneration by allowing attachment of bone-forming cells. 4. Regardless of whether a membrane had been used or not, the group with autogenous bone and $Bio-Oss^{(R)}$ filling showed the greatest amount of bone fill inside a hole, followed by the group with autogenous bone filling, the group with blood and the group with $Bio-Oss^{(R)}$ Filling in order. 5. When a membrane was inserted, regardless of the type of bone substitute used, a lesser amount of resorption occurred compared to when a membrane was not inserted. 6. The border between bone substitute and surrounding bone was the most indistinct with the group with autogenous bone filling, followed by the group with autogenous bone and $Bio-Oss^{(R)}$ filling, the group with blood, and the group with $Bio-Oss^{(R)}$ filling. 7. Three months after surgery, $Bio-Gide^{(R)}$ and $Bio-Oss^{(R)}$ were distinguishable. Conclusion: The best results were obtained with the group with autogenous bone and $Bio-Oss^{(R)}$ filling used in conjunction with a membrane.

족관절 해면골의 미세 구조 분석 (Micro-Structural Profiles of Trabecular Bone at the Ankle Joint)

  • 김현정;안태선;백명현;최문권;원예연
    • 대한족부족관절학회지
    • /
    • 제8권2호
    • /
    • pp.157-160
    • /
    • 2004
  • Purpose: This study aimed to investigate and compare the micro-structural profiles of trabecular bone from different facets at the ankle joint. Materials and Methods: In a fresh cadaver ankle, four cored 10 mm of diameter cylindrical specimens of trabecular bone were harvested from the distal tibia, the talar dome, the medial malleolus, and the lateral malleolus. Using a micro-computed tomography, two-dimensional and three-dimensional micro-structural indices of the trabecular bone were analyzed. Results: Each specimen from the tibia, talus, medial malleolus, and the lateral malleolus showed unique micro-structural pattern. Tibia versus talus, the talus was seen a higher bone volume fraction and a wider supporting zone subchondrally whereas the tibia was seen a relatively lower bone volume fraction and a much narrower supporting zone subchondrally. Lateral malleolus versus medial malleolus, the lateral malleolus was seen the thicker but sparse trabeculae pattern whereas the medial malleolus was seen the thinner but more compact trabecular pattern. Conclusion: Each four locations from the different facet at the ankle joint have distinct own micro-structural patterns of the trabecular bone, suggesting different mechanical properties.

  • PDF

보철물(補綴物) 장착시(裝着時) 치근막(齒根膜)과 치조골(齒槽骨)의 변화(變化)에 관(關)한 X선학적(線學的) 연구(硏究) (Roentgenologic Studies on the Periodontal Ligaments and Alveolar Bone Changes in Various Prosthesis)

  • 이재희
    • 대한치과보철학회지
    • /
    • 제9권1호
    • /
    • pp.17-22
    • /
    • 1969
  • Intra-oral films of 155 patients were taken on the areas of Gold Crown-Bridges, S. P. Bridges and Partial Dentures. And the author observed periodontal ligaments widening rates, the presence of periapical lesions and the alveolar bone patterns on the Partial Denture Saddle portions. The results were as follows : 1. Periodontal ligaments a) Periodontal ligaments widening rate increased obviously with the duration of wearing those prosthetic appliances. b) Periodontal ligaments widening rate was the highest in partial denture wearing patients, and then that of S. P. Crown Bridge patients, Gold Crown Bridge wearing females, Gold Crown Bridge males were the sequences. 2. Periapical lesions a) Periapical lesions increased with the wearing duration of those prosthetic appliances. But they did not increase in proportion to the duration. Periapical lesions were about the same in the teeth with those appliances showing relatively higher rate in Partial Denture abutment teeth and the lowest in Gold-Bridge abutment teeth. 3. Alveolar bone of Partial Denture saddle portion One third of all(32%) were normal with their smooth and compact bone pattern so that they were considered to perform normal function.

  • PDF

두 종류의 치과 임플란트 식립후 조직의 반응에 대한 비교연구 (Tissue Responses Around Two Types of Dental Implant in Beagle Dog)

  • 정형근;권영혁;이만섭;박준봉
    • Journal of Periodontal and Implant Science
    • /
    • 제29권4호
    • /
    • pp.929-942
    • /
    • 1999
  • Three beagle dogs aged over one and half years were used in this study. All mandibular premolars were carefully extracted. Two AVANA implants(Sumin, Korea) and two 3i implants(Implant Innovation, USA) were installed at each right and left side respectively. Each dog was sacrificed at 4, 8. 12 weeks. Non-decalcified specimens were made and stained for a light microscopic study. The results were as follows ; 1. Inflammation was not observed in the area of bone tissue adjacent to the implant body. 2. With time, quantity of osseointe-gration increased in each type of den-dental implant. There was no difference between AVANA implant and 3i implant. 3. Maturation of the bone around each type of the dental implant increased with time. 12 weeks after implant installation, the bone around dental implant represented compact bone-like appreance. 4. In case implants were located adjacent to a root, newly-formed periodontal ligament tissue was observed around the implant. And the direction of the periodontal ligament fiber was parallel to the surface of the implant . Within the results of this study, AVANA implants represented similar osseointegra-tion in comparision with 3i implants.

  • PDF

임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구 (EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE)

  • 강상규;이종호;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권1호
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF

Solitary peripheral osteomas of the jaws

  • Franca, Talita Ribeiro Tenorio De;Gueiros, Luiz Alcino Monteiro;Castro, Jurema Freire Lisboa De;Catunda, Ivson;Leao, Jair Carneiro;Perez, Danyel Elias Da Cruz
    • Imaging Science in Dentistry
    • /
    • 제42권2호
    • /
    • pp.99-103
    • /
    • 2012
  • Osteoma is a benign osteogenic tumor composed of cancellous or compact bone, classified as peripheral, central, or extraskeletal. Peripheral osteomas are uncommon. Excluding the maxillary sinuses, the maxilla is a rare site for osteomas. The purpose of this report was to describe clinicopathological and radiological features of two peripheral osteomas occurring in the jaws, one located in the mandible and another in the edentulous maxillary alveolar ridge. The tumors were asymptomatic and were fully excised without any complications or recurrence. The lesions were submitted to histopathological analysis and diagnosed as peripheral osteoma, compact type.

임플란트 보철물의 연결 여부에 따른 유한요소응력분석 (Finite Element Analysis on the Supporting Bone according to the Connection Condition of Implant Prosthesis)

  • 강재석;정제옥;이승훈
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.31-42
    • /
    • 2007
  • The purpose of this study was to compare the stress distribution according to the splinting condition and non-splinting conditions on the finite element models of the two units implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on the mandibular 1st and 2nd molars. A cemented abutment and gold screw were used for superstructures. A FEA models assumed a state of optimal osseointegration, as the bone quality, inner cancellous bone and outer 2 mm compact bone was designed. This concluded that the cortical and trabecular bone were assumed to be perfectly bonded to the implant. Splinting condition had 2 mm contact surface and non-splinting condition had $8{\mu}m$ gap between two implant prosthesis. Two group (Splinting and non-splinting) were loaded with 200 N magnitude in vertical axis direction and were divided with subdivision group. Subdivision group was composed of three loading point; Center of central fossa, the 2 mm and 4 mm buccal offset point from the central fossa. Von Mises stress value were recorded and compared in the fixture-bone interface and bucco-lingual sections. The results were as follows; 1. In the vertical loading condition of central fossa, splinting condition had shown a different von Mises stress pattern compared to the non-splinting condition, while the maximum von Mises stress was similar. 2. Stresses around abutment screw were more concentrated in the splinting condition than the non-splinting condition. As the distance from central fossa increased, the stress concentration increased around abutment screw. 3. The magnitude of the stress in the cortical bone, fixture, abutment and gold screw were greater with the 4 mm buccal offset loading of the vertical axis than with the central loading.

백서의 하악골 결손부 치유시 골형성단백질 2/4의 발현에 관한 연구 (IMMUNOHISTOCHEMICAL STUDY FOR THE EXPRESSION OF BMP-2/4 ON THE HEALING PROCESS IN THE MANDIBULAR BONE DEFECT OF RAT)

  • 최재용;이상철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권4호
    • /
    • pp.325-336
    • /
    • 2000
  • Bone morphogenetic protein-2/4 are members of Transforming Growth Factor-$\beta$(TGF-$\beta$) superfamily and they may induce formation of cartilage and bone in vivo. This study was performed to investigate the cellular target and period of action of BMP-2/4 and understanding of actions of BMP-2/4 at cellular level. The appearance of BMP-2/4 during healing of mandibular and periodontal defect in rat was evaluated immunohistochemically. 40 Sprague-Dawley strain white male rats, each weighing about 300gm were used. Bony defect was performed in the mandible and they were sacrificed at the day of 3rd, 10th, 20th, 30th after operation. The specimens were harvested and examined histologically and immunohistochemically by localization of anti-BMP-2/4. The results were as follows: 1. Woven bone was observed at 10th day and perfect healing of defect with compact bone and periodontal ligment space at 30th day. 2. Osteoprogenitor cells, osteoblastic cells and periosteum were positive reaction to immunohistochemical stain at 10th day. 3. Cells of bone marrow space and surface cells of osteocytes and cementoblasts were positive reaction to immunohistochemical stain at 20th day. 4. Newly formed osteocytes and cementocytes were positive reaction to immunohistochemical stain at 30th day. From the above findings, we could conclude that BMP-2/4 acted significant roles as factors of induction, proliferation and differentiation during bone healing process.

  • PDF

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF