• Title/Summary/Keyword: Common-mode

검색결과 854건 처리시간 0.037초

Reducing Common-Mode Voltage of Three-Phase VSIs using the Predictive Current Control Method based on Reference Voltage

  • Mun, Sung-ki;Kwak, Sangshin
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.712-720
    • /
    • 2015
  • A model predictive current control (MPCC) method that does not employ a cost function is proposed. The MPCC method can decrease common-mode voltages in loads fed by three-phase voltage-source inverters. Only non-zero-voltage vectors are considered as finite control elements to regulate load currents and decrease common-mode voltages. Furthermore, the three-phase future reference voltage vector is calculated on the basis of an inverse dynamics model, and the location of the one-step future voltage vector is determined at every sampling period. Given this location, a non-zero optimal future voltage vector is directly determined without repeatedly calculating the cost values obtained by each voltage vector through a cost function. Without utilizing the zero-voltage vectors, the proposed MPCC method can restrict the common-mode voltage within ± Vdc/6, whereas the common-mode voltages of the conventional MPCC method vary within ± Vdc/2. The performance of the proposed method with the reduced common-mode voltage and no cost function is evaluated in terms of the total harmonic distortions and current errors of the load currents. Simulation and experimental results are presented to verify the effectiveness of the proposed method operated without a cost function, which can reduce the common-mode voltage.

공통모드 초크의 간단한 고주파 모델링 기법 (Method for High-Frequency Modeling of Common-Mode Choke)

  • 정현종;윤석;김유선;배석;임영석
    • 한국전자파학회논문지
    • /
    • 제28권12호
    • /
    • pp.964-973
    • /
    • 2017
  • 본 연구는 공통모드 초크의 기생 성분이 공통모드와 차동모드에 미치는 영향을 광대역에서 분석하고, 간단한 고주파 모델링 방법을 제시한다. 공통모드와 차동모드의 2-port 회로망을 각각 구성하여 각 모드에서의 S-parameter를 Network Analyzer로 측정하였다. 측정 결과로부터 등가회로 소자를 추출하여 고주파 등가회로를 모델링하고, 측정치와 시뮬레이션 결과를 비교함으로써 타당성을 검증하였다. 이는 정확하고 예측 가능한 EMI 필터를 설계하는데 적용될 수 있다.

DSP320F240을 이용한 PWM-Inverter구동 시스템에서의 전도노이즈 저감을 위한 스위칭 기법 (A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter System using the DSP320F240)

  • 박현석;박규현;김이훈;한성용;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.355-359
    • /
    • 2002
  • Much attention has been given to EMI effects created in variable speed ac drive system. Zero switching states of inverter control invoke large common mode voltage. This paper focuses on the switching techniques to mitigate common mode voltage. This paper proposes a common-mode voltage reduction method based on sinusoidal pulse width modulation in three phase PWM inverter system. By using three carriers wave displaced by 120 degrees, it is possible to eliminate a common mode voltage pulse In one control period. Simulation and experimental results show that common mode voltages In the proposed technique are reduced more than conventional technique.

  • PDF

COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

Common-Mode Current Cancellation Scheme of Half-Bridge Switch-Mode Converter for DC Motor Drive

  • Srisawang, Arnon;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1876-1879
    • /
    • 2003
  • Due to the conventional half-bridge switch-mode converters for dc motor drive have been usually using unbalanced circuit topologies which generate common-mode currents through parasitic capacitors distributed between the ground and the dc motor frame such as the heat-sink of switching devices or the frame of the dc motor. This paper describes methods that cancel common-mode current generated in half-bridge switch-mode converters by using circuit balancing technique. The circuit balancing is to make the noise pickup or occurring in both conductor lines, signal and return pathes, is equal in amplitude and opposite in phase so that it will be canceled out in the ground plane. The common-mode current cancellation in the proposed converter is confirmed by experimental results.

  • PDF

동상분 제거에 의한 입체음향의 채널 분리도 개선 (An Enhancement of Channel Separability for Stereophonic Signals by Common Mode Rejection Method)

  • 권호열
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.439-442
    • /
    • 1998
  • In this paper, we firstly suggested C&D (Common mode and Differential mode) model for the representation of a stereophonic signal. Then a measure of stereophonic channel separability is defined as the ratio of differential mode energy to total energy in frequency domain. After that, a new channel separability enhancement scheme is proposed by the control of common mode rejection. Finally, some experimental results are presented in order to verify our scheme.

  • PDF

3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감 (Common-mode Voltage Reduction of Three Level Four Leg PWM Converter)

  • 지승준;고상기;김현식;설승기
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

다기능 케이블을 위한 연성 회로 기판에 내장된 공통 모드 필터 (Common Mode Filter Embedded in Flexible Printed Circuit Board for Multi-Function Cable)

  • 변진도;정상운;이근형;이해영
    • 한국전자파학회논문지
    • /
    • 제19권3호
    • /
    • pp.343-351
    • /
    • 2008
  • 본 논문에서는 FPC(Flexible Printed Circuit) 케이블에 적층된 나선형 인덕터를 내장하여 다기능 케이블을 위한 공통 모드 필터를 제안하였다. 공통 모드 필터가 내장된 FPC 케이블은 별도의 SMD(Surface Mounted Device) 필터 없이 연성 케이블과 공통 모드 차단 특성을 가짐으로서, 다기능 케이블이라는 새로운 개념을 제시한다. 내장된 공통 모드 필터는 광대역의 공통 모드 차단 대역을 가지고 손실이 큰 페라이트와 같은 자성 물질을 사용하지 않아 차동 모드 삽입 손실 및 반사 손실이 향상되었다. 3-turn 인덕터를 가진 공통 모드 필터는 공통 모드차단 대역이 $0.4{\sim}3.12GHz$이며, 페라이트를 적용한 상용 LTCC(Low Temperature Co-fire Ceramic) 공통 모드 필터에 비해 3 GHz에서 1.95 dB, 8 GHz에서 6.97 dB의 향상된 차동 모드 삽입 손실을 갖는다.

DC Motor Drive with Circuit Balancing Technique to Reduce Common Mode Conducted Noise

  • Jintanamaneerat, Jintanai;Srisawang, Arnon;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1881-1884
    • /
    • 2003
  • In some requirements of dc motor drive circuit applications are high quality output with generation of low internal conducted EMI. However the conventional dc motor drive circuits have been usually using unbalanced circuit which generates the high conducted EMI to the frame ground. This paper presents a balanced dc motor drive circuit which is effective way to reduce the common-mode noise. The circuit balancing is to make the noise pick up or occurring in both conductor lines, signal path and return path is equal in amplitude and opposite phase so that it will cancel out in the frame ground. The common-mode conducted noise reduction of this proposed dc motor drive is confirmed by experimental results.

  • PDF

간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계 (The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.