• 제목/요약/키워드: Common Leg

Search Result 178, Processing Time 0.021 seconds

The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement (간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

Crossover bypass in the Obstruction of the Common Iliac Vein Using with Saphenous Vein Graft - A Report of Case - (외상성 총장골정맥폐쇄에서 Palma 씨 수술치험 1례)

  • 이종락
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.337-341
    • /
    • 1989
  • A 40-year-old male developed the swelling of the right leg one month after trauma on cycling. Conservative measures to relieve the swelling of the right leg for three months were failed. Venogram showed complete obstruction of the right common iliac vein. Crossover bypass [Palmas operation] with great saphenous vein graft for relief of venous stasis of the right leg was performed. Postoperatively, the swelling of the right leg was subsided and able to walk without edema of the right leg.

  • PDF

Common-mode Voltage Reduction of Three Level Four Leg PWM Converter (3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감)

  • Chee, Seung-Jun;Ko, Sanggi;Kim, Hyeon-Sik;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

A New SVM Method to Reduce Common-Mode Voltage of Five-leg Indirect Matrix Converter Fed Open-End Load Drives

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.641-652
    • /
    • 2017
  • This paper proposes a cost-effective topology to drive a three-phase open-end load based on a five-leg indirect matrix converter (IMC) and a space vector modulation (SVM) method. By sharing an inverter leg with two load terminals, the proposed topology can reduce the number of power switches when compared to topologies based on a direct matrix converter or a six-leg IMC. The new SVM method uses only the active vectors that do not produce common-mode voltage (CMV), which results in zero CMV across the load phase and significantly reduces the peak value of the CMV at the load terminal. Furthermore, the proposed drive system can increase the voltage transfer ratio up to 1.5 and provide a superior performance in terms of an output line-to-line voltage with a three-level pulse-width modulation waveform. Simulation and experimental results are given to verify the effectiveness of the proposed topology and the new SVM method.

Compact T/R Module Having Improved T/R Isolation Using a Bias Timing Scheme (바이어스 타이밍 기법을 이용하여 송수신 격리도가 개선된 소형 송수신 모듈)

  • Park, Sung-Kyun;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1380-1387
    • /
    • 2012
  • The transmit/receive(T/R) module is a key component in the active phased array system. The brick-type T/R module has been widely used and the miniaturization has been an important factor to get the flexibility of the system configuration. For the miniaturization, multi-function chips(MFC) having a common leg configuration are suitable to reduce the number of required MMICs and a high isolation between transmit and receive paths is necessary for the high gain T/R modules. In this work, we propose a bias timing scheme for the compact T/R module and show the optimum timing based on measurements, in order to improve the feed-back path loop problem and the consequent isolation problem of the common leg configuration. We have implemented high power(7 W/channel) and high T/R gain(35 dB transmit and 30 dB receive gains) within the half size($140{\times}80{\times}16mm^3$) of the conventional T/R modules.

Cancellation of Common-Mode Voltages in Three-Level NPC Inverters with Auxiliary Leg (3-레벨 NPC 인버터에서 보조 레그를 이용한 공통 모드 전압 제거)

  • Le, Quoe Anh;Le, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.487-488
    • /
    • 2016
  • In this paper, a new active circuit for common-mode voltage (CMV) cancellation in three-level NPC (neutral-point clamped) inverters is proposed, which can avoid the saturation of the common-mode transformer (CMT). The proposed circuit utilizes an additional three-level leg to produce the compensating CMV of the NPC inverters, which eliminates the CMV of the inverter through the CMT.

  • PDF

Design and Build of Transmit/Receive Module for X Band (X 대역 T/R 모듈의 설계 및 구현)

  • Park, Sung-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.168-173
    • /
    • 2008
  • In this paper, we have designed transmit/receive Module for X band which can be applied to active phase array radar system. AESA(active electrically beam steered array) is able to transmit high power as like TWTA with composition of TH Module and steer a main beam faster than mechanically steering system. The proposed structure of T/R Module for X band is brick type for physical structure, common leg structure electrically and small size design as MCM(multi chip module). The results show that the characteristic of proposed T/R module can fully cover the specification of required military radar application.

Novel Single-State PWM Technique for Common-Mode Voltage Elimination in Multilevel Inverters

  • Nguyen, Nho-Van;Quach, Hai-Thanh;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.548-558
    • /
    • 2012
  • In this paper, a novel offset-based single-state pulse width modulation (PWM) method for achieving zero common-mode voltage (CMV) and reducing switching losses in multilevel inverters is presented. The specific active switching state of the zero common-mode (ZCM) voltage that approximates the reference voltage can be deduced from the switching state sequence of the reduced CMV phase disposition PWM (CMV PD PWM) method. From the reference leg voltages for the zero common-mode voltage, an N-to-2-level transformation defines a virtual two-level inverter and the corresponding nominal leg voltage references. The commutation process of the reduced CMV PD PWM method in a multilevel inverter and its outputs can be simply followed in a nominal switching time diagram for the virtual inverter. The characteristics of the reduced CMV PD PWM and the single-state PWM for zero common-mode voltage are analyzed in detail in this paper. The theoretical analysis of the proposed PWM method is verified by experimental results.

A Study on Performance of Indirect-contact Driven-right-leg Ground in Indirect-contact ECG Measurement (간접접촉 심전도 측정에서의 간접접촉 오른발 구동 접지 성능에 대한 연구)

  • Lim, Yong-Gyu;Kim, Ko-Keun;Park, Kwang-Suk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2008
  • For the reduction of common-mode noise level in Indirect-contact ECG (IDC-ECG) measurement a driven-right-leg grounding method was a lied to the IDC-ECG. Because the IDC-ECG does not require any direct contact between the electrodes and the human skin. it is adequate for un-constraining long-term ECG measurement at home and its various applications are now under development. However, larger 60 Hz noise induced by power line a ears in IDC-BCG than in conventional ECG, that is a restriction of IDC-ECG a application. In this study, the driven-right-leg ground which has been used in conventional direct-contact ECG, was adapted to the IDC-ECG measurement by feedback of the inversion of amplified common-mode noise to the body through the conductive fertile laid on the chair seat By this study, indirect-contact driven-right-leg ground was developed and it was shown to work stably. It was shown that the level of 60Hz power line noise was reduced to about -40 dB when the driven-right-leg gain was 1000. This study shows that we can extend the upper limit of the frequency band of IDC-ECG to 100Hz from 30Hz which is conventional upper limit in IDC-ECG, and we can raise the ground impedance between the body and conductive textile. So it is expected that the application area of the IDC-ECG will be extended by the results of this study.

  • PDF

The Change of Muscle Activities of Trunk Muscles during Various Leg-Crossing Positions in Low Back Pain Patients (다양한 다리 꼬기 자세가 요통환자의 체간근 활성도에 미치는 영향)

  • Kim, Tae-Ho;Seo, Hyun-Kyu;Gong, Won-Tae
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.5
    • /
    • pp.1-10
    • /
    • 2007
  • Purpose: Leg-crossing sitting is very common for men and woman. No solid evidence exists for either a beneficial or a detrimental effect of this posture. This study investigated the change of activities of trunk muscles between the normal group and the low back pain group during various leg-crossing positions. Methods: The subjects were consisted of 10 subjects who don't have low back pain and 10 subjects who have low back pain. In this study, we used electromyography(EMG) to evaluate the activities of both the trunk muscles (rectus abdominis, external oblique, internal oblique, and multifidus) during various leg-crossing positions (up-right, leg-crossing, tailor-crossing, and ankle-crossing). We analyzed the data by using repeated one way ANOVA. Results: In normal group, there were increased in EMG activities of trunk muscles, but no significant differences during leg-crossing positions. In back pain group, there were increased in EMG activities of right external oblique, left. internal oblique, and both multifidus muscles in leg-crossing and tailor-crossing position, but no significant differences during leg-crossing positions. There was no significant difference of muscle activity of trunk muscles between the back pain group and the normal group. Conclusion: We suggest that low back pain people who have weak muscles of rectus abdominis, external and internal oblique are often experienced in leg-crossing posture than normal. To compensate this unstability of trunk, leg-crossing posture is substituted passive structure for activities of active muscle.

  • PDF