• Title/Summary/Keyword: Commercial Test

Search Result 2,684, Processing Time 0.049 seconds

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

Antimicrobial resistance patterns of Listeria species and Staphylococcus aureus isolated from poultry carcasses in Korea (계육에서 분리한 Listeria species 와 Staphylococcus aureus의 항생제 내성패턴)

  • Hur, Jin;Kim, Jun Man;Kwon, Nam Hoon;Park, Kun Taek;Lim, Ji Youn;Jung, Woo Kyoung;Hong, Soon Keun;Park, Yong Ho
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.217-224
    • /
    • 2004
  • This study was carried out to investigate the antibiotic resistance pattern of Listeria spp. and Staphylococcus aureus. A total of 17 (14.8%) L. monocytogenes, 13 (11.3%) L. innocua, 7 (7%) L. welshimeri, and 83 (72.2%) S. aureus were isolated from commercial poultry carcasses in Seoul and Kyonggi province during the period between 2001 and 2003. Antibiotic susceptibility test of all Listeria strains isolated was performed by the disk agar diffusion method. Antibiotics used in the study were as follows; Amikacin (An), Ampicillin (Am), Cephalothin (Cf), Chloramphenicol (C), Ciprofloxacin (Cip), Erythromycin (E), Gentamicin (Gm), Imipenem (Ipm), Kanamycin (K), Minocycline (Mi), Neomycin (N), Norfloxacin (Nor), Ofloxacin (Ofx), Penicillin (P), Streptomycin (S), Tetracycline (Te), Tobramycin (Nn), Trimethoprim (Tmp), Trimethoprim/Sulfamethoxazloe (Sxt), and Vancomycin (Va). The antibiotic resistance pattern of S. aureus isolates was performed by the disk agar diffusion method. For the latter program, antibiotics used to the study were as follows; Cf, C, Cip, Clindamycin (Cc), E, Gm, Ipm, Nafcillin (Nf), Oxacillin (Ox), P, Te, Sxt, and Va. Of the 17 L. monocytogenes isolates, 94.1% were resistant to Te, 88.2% to Mi, 11.8% to Nor, 11.8% to S, 5.9% to Cip, and 5.9% to C. Of 13 L. innocua, 53.8% were resistant to Te, 23.1% to Mi, 23.1% to S, 7.7% to Cip, and 7.7% to Nor. Of 7 L. welshimeri, 57.1% were resistant to Te, and 14.3% to Am. Of 83 S. aureus, 100% were resistant to Te, 86.7% to Gm, 34.9% to P, 15.7% to Cip, 12% to Cc, 9.6% to E. The multiple antibiotic resistance patterns of L. monocytogenes isolates were observed in Te Mi Cip (5.9%), Te Mi Nor (5.9%), Te Mi (76.5%), and Te Nor (5.9%). Multiple antibiotic resistance was also found in L. innocua isolates. Resistant to Te Mi S Cip Nor was 7.7%, Te Mi S (7.7%), Te Mi (7.7%), and was 7.7% to Te S. Antibiotic resistance patterns for S. aureus isolats were demonstrated to Te Gm P Cip Cc E (6.0%), Te Gm Cip Cc E (3.6%), Te Gm P Cc (1.2%), Te Gm P (15.6%), Te Gm Cip (2.4%), Te P Cip (2.4%), Te Gm Cc (1.2%), Te Gm (56.6%), Te P (9.6%), and to Te Cip (1.2%). The results of this study suggest a high incidence of Lsteria spp. and S. aureus on poultry carcasses. The contaminated poultry carcasses may be a potential vehicle for foodborne infections due to multiple antimicrobial resistant organisms.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Purification of Vibrio anguillarum Growth Inhibition Factor Produced by Bacillus amyloliquefaciens H41. (Bacillus amyloliquefaciens H41이 생산하는 Vibrio anguillarum 생육 저해인자의 정제)

  • Shin, Hyun-Chul;Chung, Kyung-Tae;Kim, Kwang-Hyun;Kim, Byung-Woo;Kwon, Hyun-Ju;Lee, Eun-Woo;Yum, Jong-Hwa;Rhu, Eun-Ju;Jeong, Yu-Jeong;Kim, Young-Hee
    • Journal of Life Science
    • /
    • v.18 no.6
    • /
    • pp.789-795
    • /
    • 2008
  • To study the possible use of probiotics in fish farming, we evaluated antagonism of antibacterial strain Bacillus amyloliquefaciens H41 against the fish pathogenic bacterium Vibrio anguillarum NCMB1. The purification of growth inhibition factor produced by B. amyloliquefaciens H41 was achieved by obtaining supernatant of this bacterium. The growth inhibition factor was purified to homogeneity by 70% ammonium sulfate precipitation, DEAE-sephadex A-50 ion exchange chromatography, sephadex G-200 gel filtration column chromatography, and sephadex G-50 gel filtration column chromatography with 40.8 fold of purification and 2.9% yield. The molecular weight of the purified growth inhibition factor was 48 kDa as determined by sodium dodecyl sulfate polyacrylamide gel electrophoresis. The optimum pH and temperature for the growth inhibition factor were pH 7.5 and $30^{\circ}C$, respectively. The activity of growth inhibition factor was enhanced slightly by some metal ions, such as $Mg^{+2}$, $Mn^{+2}$, but was inhibited by the addition of $Co^{+2}$, $Hg^{+2}$, $Zn^{+2}$ and $Ag^{+2}$. NaCl stability of the growth inhibition factor was observed with 50% residual activity at 3% NaCl concentration. Toxicity test showed that the purified B. amyloliquefaciens H41 growth inhibition factor did not affect the live of Japanese flounder (Paralichthys olivaceus) and the effectiveness was 78% of residual lethality compared to commercial antibacterial agents.

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF

Assessment of Both Standard and Isolated Vibrio parahaemolyticus on Efficacy of Commercial Sanitizers and Disinfectants (Vibrio parahaemolyticus 표준 및 식품분리 균주에 대한 살균소독제 유효성분별 감수성 평가)

  • Kim, Il-Jin;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.127-131
    • /
    • 2007
  • This study evaluated the bactericidal effect of 10 sanitizers and disinfectants such as ethanol (75 and 95%), iodine (15 and 25 ppm), chlorine (100 and 200 ppm), quaternary ammonium, acid, hydrogen peroxide, and peroxide acetic acid against V. parahaemolyticus. Ten strains of V. parahaemolyticus isolated from Korean foods and 4 strains of standard V. parahaemolyticus were compared for efficacies of various sanitizers and disinfectants by EN 1276 method based on quantitative suspension test. Ethanol (75 and 95%), 25 ppm of iodine, 100 ppm of quaternary ammonium, 145 ppm of hydrogen peroxide and acid showed more than $5log_{10}CFU/mL$ reduction in both clean and dirty conditions. Tests result of chlorine (100 ppm) showed more than $5log_{10}CFU/mL$ reduction in clean condition. Iodine (15 ppm) showed more than $5log_{10}CFU/mL$ reduction except 4 isolated and 1 standard V. parahaemolyticus in clean condition. iodine (15 ppm) also showed under $5log_{10}CFU/mL$ reduction $(0.93{\sim}3.73log_{10}CFU/mL)$ in dirty condition. Eleven hundred ppm of hydrogen peroxide was evaluated as weak sanitizer and disinfectant due to their $0.99{\sim}4.79log_{10}CFU/mL$ reduction on both clean and dirty conditions. Consequently, ethanol, iodine (25 ppm), chlorine (200 ppm), quaternary ammonium, acid and peroxide acetic acid were thought to be effective sanitizer and disinfectant against V. parahaemolyticus.

The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design - (수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로-)

  • 박문갑;윤갑동;김석제;윤종락
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.302-307
    • /
    • 2001
  • The underwater background noise measured in Geoje and Tongyoung diving fishing ground from May to December, 2000 and analyzed to get optimum carrier frequency and transmitter power level for underwater wireless telephone design. The results obtained are summarized as follows: 1. At the Geoje and Tongyoung diving fishing ground, the lowest ambient noise band was 25~30kHz with 57dB and 52dB re 1$\mu$Pa, respectively. 2. At the Geoje and Tongyoung diving fishing ground, the lowest noise band during fishing activity was 67dB and 62dB re 1$\mu$Pa, respectively. 3. At the Geoje diving fishing ground, the noise of water jetter which is a digging machine for subbottom shells was 102dB re 1$\mu$Pa. 4. Considering the design parameters of underwater wireless telephone, it is found that the optimum carrier frequency band is around 30kHz and the transmitter source level should be at least 131dB re 1$\mu$Pa for 500m range telephone.

  • PDF

Development and Validation of Real-time PCR to Determine Branchiostegus japonicus and B. albus Species Based on Mitochondrial DNA (Real-time PCR 분석법을 이용한 옥돔과 옥두어의 종 판별법 개발)

  • Chung, In Young;Seo, Yong Bae;Yang, Ji-Young;Kim, Gun-Do
    • Journal of Life Science
    • /
    • v.27 no.11
    • /
    • pp.1331-1339
    • /
    • 2017
  • DNA barcoding is the identification of a species based on the DNA sequence of a fragment of the cytochrome C oxidase subunit I (COI) gene in the mitochondrial genome. It is widely applied to assist with the sustainable development of fishery-product resources and the protection of fish biodiversity. This study attempted to verify horse-head fish (Branchiostegus japonicus) and fake horse-head fish (Branchiostegus albus) species, which are commonly consumed in Korea. For the validation of the two species, a real-time PCR method was developed based on the species' mitochondrial DNA genome. Inter-species variations in mitochondrial DNA were observed in a bioinformatics analysis of the mitochondrial genomic DNA sequences of the two species. Some highly conserved regions and a few other regions were identified in the mitochondrial COI of the species. In order to test whether variations in the sequences were definitive, primers that targeted the varied regions of COI were designed and applied to amplify the DNA using the real-time PCR system. Threshold-cycle (Ct) range results confirmed that the Ct ranges of the real-time PCR were identical to the expected species of origin. Efficiency, specificity and cross-reactivity assays showed statistically significant differences between the average Ct of B. japonicus DNA ($21.85{\pm}3.599$) and the average Ct of B. albus DNA ($33.49{\pm}1.183$) for confirming B. japonicus. The assays also showed statistically significant differences between the average Ct of B. albus DNA ($22.49{\pm}0.908$) and the average Ct of B. japonicus DNA ($33.93{\pm}0.479$) for confirming B. albus. The methodology was validated by using ten commercial samples. The genomic DNA-based molecular technique that used the real-time PCR was a reliable method for the taxonomic classification of animal tissues.

Efficacy of Antibacteriocidal Yeast That Producing Bacteriocin OR-7 in Chicken (박테리오신 OR-7을 생산하는 항균 효모의 양계에서의 사양시험 효과)

  • Cho, Dong-In;Kang, Sang-Mo;Lee, Jae-Hwa;Lee, Sang-Hyeon;Kim, Nam-Young;Kim, Ki-Seuk
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.391-398
    • /
    • 2010
  • This study was conducted to investigate the effects of feeding probiotics(gene modified yeast) on the egg quality in laying hens. The laboratory method of this study is as follow: In hens, 300, 36 weeks old ISA brown commercial layer, were employed in 13weeks feeding trial with a 7 days adjustment period. Dietary treatments are 1) control (basal diet) 2) Y0.3 (basal diet+0.3% probiotics), 3) Y0.5% (basal diet+0.5% probiotics), 4) PY0.3% (basal diet+0.3% plasmid modified probiotics), 5) PY0.5% (basal diet+0.5% plasmid modified probiotics). For overall period, hen-day egg production, egg weight (p<0.05) by dietary probiotic supplementation were recorded. Eggs were collected and weighed every day. Egg production number and egg production rate, egg weight, failure egg ratio and trouble egg ratio were recorded for 13weeks days. Diets PY0.3 and PY0.5 improved Egg production rate, egg production number and egg weight, compared to control diet (linear effect. p<0.05). And, diets PY0.3 and PY0.5 improved Egg production rate, egg production number, compared to Y0.3 and Y0.5 (linear effect. p<0.05). But, in Inferior egg and cracked egg, diets PY0.3 and PY0.5 did not tended to increase by dietary probiotic supplementation compared to control diet and Y group (0.3, 0.5) (linear effect. p<0.05). The productivity enhance on the egg quality in laying hens is considered from the effects of feeding probiotics(gene modified yeast).

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).