• 제목/요약/키워드: Comfort air-conditioning

검색결과 243건 처리시간 0.025초

난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발 (A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating)

  • 김용기;우남섭;이태원;안병천
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구 (A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

건축물 축열성능 향상을 위한 Octadecane/xGnP SSPCM 제조 및 열적성능 분석 (Preparation and Thermal Properties of Octadecane/xGnP Shape-Stabilized Phase Change Materials to Improve the Heat Storage Performance of Buildings)

  • 김석환;정수광;이정훈;김수민
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.126-130
    • /
    • 2013
  • In this study, a shape-stabilized phase change material (SSPCM) was prepared by octadecane and exfoliated graphite nanoplate (xGnP) in a vacuum, to improve thermal storage performance. The octadecane as an organic phase change material (PCM) is very stable against phase separation of PCM, and has the proper temperature range for thermal comfort in the building; and the xGnP is a porous carbon nano-material. Scanning electron microscope (SEM) and Fourier transformation infrared spectrophotometer (FT-IR) were used to confirm the chemical and physical stability of the Ocatadecane/xGnP SSPCM. In addition, thermal properties were determined by Deferential scanning calorimeter (DSC), and Thermogravimetric analysis (TGA). The specific heat of Octadecane/xGnP SSPCM was $14.1J/g{\cdot}K$ at $31.3^{\circ}C$. The melting temperature ranges of melting and freezing were found to be $26{\sim}35^{\circ}C$ and $26{\sim}19^{\circ}C$, respectively. At this time, the latent heats of melting and freezing were 110.9 J/g and 104.5 J/g, respectively. The Octadecane was impregnated into xGnP by as much as about 56.0% of the Octadecane/xGnP SSPCM's mass fraction.

복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향 (Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center)

  • 최병보;전현식;윤석일;김석환;이상진;김수민
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

표준실내기후 설정에 관한 기초조사연구 -열환경요소와 착의량이 온냉감반응에 미치는 영향- (A Field Survey on the Standard Establishment of Thermal Indoor Climate - with the effect of thermal environmental factors, and clothing to the thermal sensation -)

  • 최혜선
    • 대한설비공학회지:설비저널
    • /
    • 제16권6호
    • /
    • pp.590-605
    • /
    • 1987
  • The purpose of this study was to investigate thermal environmental factors, thermal clothing properties, and thermal sensation of the office workers in four selected office buildings in Seoul, and to determine the effect of thermal environmental factors and clothing insulation to the thermal sensation of the subjects. The subjects selected from each office were 5 males and 5 females at a time. Thermal environmental factors(DBT, GT, RH, MRT, $ET^{\ast}$) and clothing variables such as clothing weight per body surface $area(g/m^2)$ and estimated clothing insulation values(clo) were significantly different among each seasons(p<0,001). Means of $ET^{\ast}$ and estimated clothing insulation values of each season were as follows; Winter; $20.84^{\circ}C$ $ET^{\ast}$ with 0.72 clo for male and 0.79 clo for female Spring and fall; $23.65^{\circ}C$ $ET^{\ast}$ with 0.59 clo for male and 0.68 clo for female Summer; $26.00^{\circ}C$ $ET^{\ast}$ with 0.47 clo for male and 0.53 clo for female. In comparison these data with ASHRAE Standard, the subjects were predicted to feel comfort-able in spring and fall, and slightly hot in summer and slightly cold in winter because of high and low clo respectively. But the result of this survey showed more than $80\%$ of the occupants were thermally comfortable at a given environmental temperature and clo.

  • PDF

IoT 센서를 이용한 공기 자동조절 스마트 에어카시트 제어 시스템 개발 (Development of Smart Air Car Seat Control System for Automatic Air Conditioning using IoT Sensor)

  • 김대훈;정수은;박수현
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.208-210
    • /
    • 2021
  • 인터넷에 연결되는 사물의 수가 급격히 증가함에 따라 센서와 통신 기능을 포함해서 단순 모니터링 기능을 하거나, 서버로 전달하는 기능에서 벗어나 점점 인간에게 직접 가치를 제공하는 지능형 디바이스 개발 사업이 확장되고 있다. 따라서 디바이스가 주변 센싱 정보를 분석해서 주변 환경을 사용자들의 기호나 안전을 고려해서 변경하는 기술을 개발할 전망으로. 공기를 이용하여 다양한 효과를 가져올 수 있는 개발 제품에 생체신호 측정 시스템을 구축함으로써, 착좌 시 압력 분포의 변화 패턴을 통해 사용자의 상태를 파악할 수 있게 할 예정이다. 온도측정 센서와 사용자의 접촉을 통해 에어카시트 사용에 쾌적함을 높이고, 본 논문에서는 생체신호 측정 데이터에 의한 에어펌프 제어 시스템을 연계하여 구축하여 측정된 생체신호는 스마트폰 애플리케이션을 통해 보호자가 확인 및 조절을 할 수 있도록 하여 효과적으로 관리가 가능한 구축 시스템을 제안한다.

  • PDF

전동차용 Blow-Down HVAC 덕트 시스템의 유동 균일도 향상을 위한 수치적 연구 (Numerical Study to Improve the Flow Uniformity of Blow-Down HVAC Duct System for a Train)

  • 김준형;노주현
    • 한국유체기계학회 논문집
    • /
    • 제19권1호
    • /
    • pp.18-23
    • /
    • 2016
  • A HVAC(Heating Ventilation and Air Conditioning) is adapted to increase the comfort of the cabin environment for train. The train HVAC duct system has very long duct and many outlets due to the shape of a train set. the duct cross section shape is limited by a roof structure and equipments. Therefore, the pressure distribution and flow uniformity is an important performance indicator for the duct system. In this study, the existing blow down type HVAC duct system for a train was supplemented to improve the flow uniformity by applying a design method combining design of experiment (DOE) with numerical analysis. The design variables and the test sets were selected and the performance for each test set was evaluated using CFD(Computational Fluid Dynamics). The influence of each design variable on the system performance was analysed based on the results of the performance evaluation on the test sets. Furthermore, the optimized model, whose the flow uniformity was improved was produced using the direct optimization(gradient-based method). Finally, the performance of the optimized model was evaluated using numerical analysis, and it was confirmed that its flow uniformity has indeed improved.

기상 데이터 산정 기간에 따른 국내의 설계용 외기온도 분석 (Analysis of South Korea Outdoor Design Temperature with respect to Assigned Period of the Weather Data)

  • 남아영;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Outdoor design temperature is important for selecting proper capacity of heating and cooling systems of a building to implement indoor thermal comfort and save energy consumption. The purpose of this study is to investigate the change of South Korea outdoor design temperature according to the assigned period. When outdoor design temperature of 8 locations calculated with the latest weather data during 2008~2015 years using ASHRAE Bin method are compared to the standard temperature of Ministry of Land, Infrastructure and Transport which is widely used for designing South Korea air-conditioning system at present, the maximum temperature difference becomes $0.97^{\circ}C$ for cooling, and $1.94^{\circ}C$ for heating. Due to wide outdoor temperature variation, update of outdoor design temperature based on recent weather data is recommended.

남측외벽에 적용한 혼합형 태양열시스템의 성능 분석 (Performance Analysis of Combined Passive Solar System for Building South Wall)

  • 윤태균;이현수;장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.42-49
    • /
    • 2012
  • In this article, the author carried out a theoretical study on the application techniques of a new Combined Passive Solar System (hereinafter referred to as the CPSS) of direct gain and trombe walls to get quick morning heating and to prevent afternoon overheating for office building. The numerical model proposed in this study can be used for the performance analysis of the CPSS in the winter and summer. Heating and Cooling loads are analysed for building energy consumption reduction using this numerical model. The results indicate that CPSS in the winter and summer modes could provide profitable conditions for improvement of indoor thermal comfort control and energy saving. consequently, the application of CPSS will not lead to significant reductions in the auxiliary air conditioning demand but also realize the environmentally friendly building.

복합 공간 구성 건물의 공조구역 운영 전략에 따른 에너지부하 특성 연구 (Study on the Operation Strategy of A Building with Multi-Complex Spaces)

  • 육인수;김민환;남현진;김동호;설동문;이건태;김진호;김재민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.108-113
    • /
    • 2009
  • Buildings with multi-complex spaces designed for architectural values and functional requirements give rise to technical challenges in terms of energy efficiency and thermal comfort. Since spaces in such buildings are connected with openings with geometrical complexity, it is hard to define zoning plan and to control heating/cooling loads effectively. This paper presents a case study on the evaluation of operation strategy for a building with multi-complex spaces using computer simulation. The modelling methodology and the results of the simulations are also described.

  • PDF