• Title/Summary/Keyword: Comfort Survey

Search Result 397, Processing Time 0.021 seconds

A Field Survey of Thermal Comfort in Office Building with Thermal Environment Standard (온열환경기준에 따른 여름철 사무실의 열쾌적성 평가)

  • Kong, Hyo-Joo;Yun, Geun-Young;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.37-42
    • /
    • 2011
  • This study aims to analyze the field survey of thermal comfort in office building with national thermal environment standard. Internal and external temperatures were measured at ten minute intervals and compared in accordance with the national standard for thermal environment. Sixty two workers filled in the questionnaire survey forms five times a day for 40 days. Field monitoring of offices in Seoul, Korea were conducted from 20 July to 28 August. Result for the comfort temperature was set a $26.30^{\circ}C$. This indicates that the 26 degree is reliable for the Korean standard. Indoor temperature standard can reduce energy use by air-conditioned buildings and the temperature would be offer comfort to occupants.

Evaluation on comfort in P.C. Apartment (공업화 주택의 쾌적성에 대한 거주자 반응)

  • 이지숙
    • Journal of the Korean housing association
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 1997
  • This thesis is dealt with the thermal environment, the indoor air environment, the sound environment and the light environment in P.C apartment house. The purpose of this study is to analyze degrees of 'the cognition'. 'the importance', and ‘the satisfaction' on indoor environmental factors and to evaluate comfort of indoor environment based on residents' responses. The questionnaire survey was given to the residents at P.C apartment complex in Rowon-Gu, Seoul. The following are the results obtained in this thesis. The results of Path analysis on comfort revealed that factors of direct effect to comfort were the satisfaction on indoor air environment and sound environment and the cognition on indoor air environment and sound environment. The satisfaction on indoor air environment was the biggest variable which decided the comfort. By the survey of P.C apartment residents' responses, the level of P.C apartment indoor comfort was found uncomfortable. It is meaningful to su99est the model evaluating comfort by residents' responses .

  • PDF

Development of Comfort Control Logic for VRF System in Summer Season by using 3 Environment Factors(Temperature, Humidity and Air flow) (온도, 습도, 기류를 이용한 하절기 VRF 시스템의 쾌적 제어 알고리즘 개발)

  • Kim, Jong-Min;Choi, Jae-Boong;Lee, Sang-Won;Cho, Doo-Ho;Lee, Pil-Ho;Kim, Young-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.610-619
    • /
    • 2011
  • This paper investigates the simplified comfort index and control logic for VRF (Variable Refrigerant Flow) system by using 3 environmental factors such as temperature, humidity and air flow. Indoor test under thermal load was conducted to explore relationship of each environment factors that is related to simplified comfort index. Simplified comfort function that has 3 environmental variables was proposed based on survey results. Each factor is measured and comfort preference was surveyed by more than 30 subjects in the indoor comfort test. Moreover, control logic for VRF system was developed and then simulated by using thermal load calculation method and verified with test. The proposed comfort function was in good agreement with survey results, and also verification test trend of comfort change and maintenance are quite similar with survey. Furthermore, through the additional test data analysis some differences of comfort according to position of people staying in the test room were additionally investigated by air flow. People being under an exit of air in the indoor air-conditioner feel more comfortable condition and speed of response to comfort change is relatively fast.

A Survey on Satisfaction of Protective Clothing for Riot Policemen (남자경찰보호복 착용실태 및 만족도에 관한 연구)

  • Kim, Jihyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.3
    • /
    • pp.419-432
    • /
    • 2015
  • This paper examines the protective clothing satisfaction rate of riot policemen. The protective clothing currently in use is the version that underwent enhancement and was distributed in 2009. This version underwent significant enhancements compared to the protective clothing introduced in 1996 in terms of safety and body fitness; however, there is room for further enhancement in terms of activity, thermal comfort and easiness. In this research, a questionnaire survey was conducted on 386 riot policemen working at the Seoul Riot Police Station to study their use of protective clothing and satisfaction rate. The survey questions included safety, activity and body fitness in terms of functionality and comfort as well as easiness and design in terms of wearing comfort. Activity scored the lowest (2.89) in terms of functionality as well as comfort (2.40) that scored the lowest in terms of wearing comfort. It is concluded that, in order to correct deficiencies, the weight of protective clothing must be reduced and design changes must be made to eliminate unnecessary areas in clothing and facilitate faster dressing/undressing. In addition, it is strongly recommended that shock absorption materials be inserted only in vital areas in order to enhance thermal comfort.

Thermal Comfort in Outdoor Environment by Questionnaire Survey : Using the Logistic Regresstion (로지스틱 회귀분석을 활용한 옥외공간에서의 온열쾌적감에 대한 피험자 설문 분석)

  • Lim, Jong-Yeon;Hwang, Hyo-Keun;Ryu, Min-Kyung;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.97-101
    • /
    • 2009
  • Calculating and predicting the thermal comfort in outdoor environment are difficult than in indoor environment because composition parameters are variable, interrelations among parameters are very complex and human activities in outdoor are diverse. Moreover, the thermal expectancy of subject in outdoor environment is different from that of indoor environment. The aims of this study are to examine the difference between indoor and outdoor thermal comfort range. With this in mind, field measurement for estimating outdoor thermal environment and a questionnaire survey with simultaneous measurement around the subject were conducted.

  • PDF

Evaluating Comfort of Indoor Environment Based on Residents' Responses (신도시 아파트 거주자의 실내환경 쾌적성 평가)

  • 이지숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.213-219
    • /
    • 1997
  • The purpose of this study is to propose a model for evaluating comfort of indoor environment based on residents' subjective respones. The questionnaire survey was given to the residents at apartment complex located in Ilsan, Kyunggi-Do. The following are the results obtained in this thesis. The results of path analysis on comfort revealed that direct effects to comfort were the satisfaction on thermal environment, indoor air environment and sound environment, and the cognition on indoor air environment and sound environment. An evaluation formula of comfort by the factors of direct effects was given. This formula is recommended to evaluate comfort for pp.O.E(post occupancy evaluation)by residents.

  • PDF

Evaluation of Car Seat Using Reliable and Valid Vehicle Seat Discomfort Survey

  • Deros, Baba Md.;Daruis, Dian Darina Indah;Nor, Mohd Jailani Mohd
    • Industrial Engineering and Management Systems
    • /
    • v.8 no.2
    • /
    • pp.121-130
    • /
    • 2009
  • Subjective evaluation has always been regarded as a branch of social science research. Hence, in scientific and especially engineering points of view, its development is always taken for granted despite the importance of its effects on the design and development decisions. In the past, at least two automotive seat survey questionnaires have been developed with high statistical validity and reliability. Nonetheless, both were not local while subjective perception very much depends on demographic background factors. It is felt that since vehicle seat comfort is an important aspect in a seat design, a local sense should be put into the survey that is used as the subjective tool. The proposed vehicle seat discomfort survey questionnaire was developed in dual languages; English and Malay. Malay language is the national language of Malaysia, where the survey was tested. Beside inputs from literatures, key informant interviews helped in establishing the appropriate terms used as survey items. Three experimental runs on two different seats by 22 paid subjects showed that the developed questionnaire is reliable and valid. Furthermore, criterion validity analysis on the survey and previously developed survey showed significant correlation at 0.01 significance level.

Visual Comfort Evaluation of Interior Spaces by Daylighting Systems (채광시스템 유형별 실내공간의 시각적 쾌적성에 관한 평가)

  • Jeong, In Young;Choi, Yoon Seck;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Daylight is a critical factor in architecture, as it enhances the working efficiency and visual comfort of the people working inside. Even though, low transmittance glazing has been used in the most office buildings in Korea. And it is reduced visual comfort in a indoor environment. So, we need to evaluation of quality for various daylighting systems to improve visual comfort This study aims to evaluate the visual comfort in a indoor environment by different daylighting system. For the purpose, four different daylighting systems-conventional window, conventional window with interior lightshelf, differentiated window, differentiated window with interior lightshelf-were selected and a questionnaire survey with 50 subjects were conducted. The results are as follows. Regardless daylighting systems, a view has an effect on visual comfort. A conventional system and conventional system with lightshelf were highly correlated between comfort and warmth. In case of differentiated window system were correlated between comfort and openness. Also, differentiated window with interior lightshelf were highly correlated between comfort and stability.

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

Indoor Environment Due to Multi-cultural Complex Space Structure Impact on the Choice of Guests (복합 문화공간 구조에 따른 실내환경이 이용객의 선택에 미치는 영향)

  • Kang, Jin-Young;Won, Young-Suk;Cha, Jung-Hoon;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.4
    • /
    • pp.278-286
    • /
    • 2011
  • Today, people are becoming more conscious regarding environmental-friendliness, and the society as a whole is becoming more aware of it. With such phenomenon, the purpose of this research is to examine how comfort and pleasantness of indoor environment influences when selecting a place for multi-cultural complex. To demonstrate the stated hypothesis, I have preceded the experiment by selecting the C multi-cultural complex of closed-type structure and T multi-cultural complex of open-type structure. The next step I took, in order to validate the public's awareness of environmental-friendliness, was conducting a survey. I then deducted a conclusion through comparison and analysis of experiment measures with survey result. As a result of the research, the experiment measures of each air, light, heat condition of the T multi-cultural complex of open-type structure had a higher measurement for the comfort and pleasantness than the C multi-cultural complex of closed-type structure. Moreover, after validating the consciousness of the public through the survey, they had a tendency preferring T multi-cultural complex of open-type structure over C multi-cultural complex of closed-type structure in terms of comfort and pleasantness. To summarize, it is proper to conclude that the criteria - comfort and pleasantness of indoor environment - has influenced significantly when it comes to selecting a multi-cultural complex through both the experiment and the survey result.

  • PDF