• Title/Summary/Keyword: Combustible materials

Search Result 161, Processing Time 0.026 seconds

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

Studies on the Morphology of Smoke Particles for Each Type of Fire by Using Steady State Tube Furnace (등속공급 튜브연소로를 이용한 각 연소조건에서의 연기입자 형상 분석)

  • Goo, Jaehark
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.44-51
    • /
    • 2014
  • Smoke from fire is a mixture of combustion gases and particles which include micro-droplets formed from condensed organic vapors and carbonaceous agglomerates. The inhalation of smoke particles causes adverse health effects, and it is prerequisite for the hazard and risk analysis of the smoke particles to know how they behaviour in the respiratory tract. The characteristics of the absorption and adsorption of toxic gases and the amount and location of the particle deposition within the respiratory tract that determine the adverse health effects are related to the morphology and the size distribution of smoke particles. In the present work, as a preliminary study for the adverse health effects of smoke particles, the morphologies of the smoke particles from combustible materials were investigated for each fire stage: smouldering, well-ventilated flaming, small under-ventilated flaming, fully-developed under-ventilated fire. The steady-state tube furnace method given in ISO/TS 19700 was used for the generation of smoke particles. The fire stages were controlled by changing furnace temperature and equivalent ratio. The morphologies were analyzed by using Transmission Electron Microscope (Bio-TEM) by collecting the particles on TEM grids put on each stage of a cascade impactor.

Experimental Study on Moisture Content According to Addition of Surfactants (계면활성제 첨가에 따른 함수율에 관한 실험적 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.79-83
    • /
    • 2015
  • The fire accident is a representative type of disaster that can largely impact on business. Therefore, precautionary measures and rapid initial response is very important when a disaster occurs. The storage of porous combustibles is inevitable in coal yard, plywood processing industry, and others that are currently operating. Initial fire fighting of fire and identifying the ignition point in such a porous combustible storage space are so difficult that if the initial response is failed, being led to deep-seated fire, surface fire is likely to result in secondary damage. In addition, deep-seated fire can cause personal injuries and property damage due to a large amount of toxic gases and reignition. Therefore damage reduction measures is required around the storage space to handle a porous flammable. Improving the penetration performance of the concentration of the surfactant is carried out as underlying study, which is about an deep-seated fire extinguishing efficiency augmentation when using wetting agents. The porous materials used in the experiments is radiata pine wood flour, which occupies more than 75% of the domestic wood market. Fire fighting water is selected as Butyl Di Glycol (BDG), which is being used for infiltration extinguishing agent, and the experiment was carried out by producing a standard solution. The experiment was carried out on the basis of the Deep-Seated Fire Test of NFPA 18. The amount of watering, porous material to the internal amount of penetration, and runoff measurement out of the porous material was conducted. According to experimental results, as the surface tension is reduced, the surfactant concentration macroscopic penetration rate decreases, but infiltration to a porous material is shown to have growth characteristics.

Research on Fire Safety of Mortar-Containing Waste Tire Powders and Flame Retardant (폐타이어 분말과 난연제가 혼입된 모르타르의 화재안전에 관한 연구)

  • Park, Jeong-Jin;Son, Ki-Sang
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.12-17
    • /
    • 2010
  • The purpose of this study is to determine how effectively waste tire recycled material mixed with flame retardant work in combating fire. As discovered in the previous study, waste tire mixed with cement mortar has more insulation capacity. However, this mortar is weak against fire. Therefore flame retardant, with a specific proportional mix, will be added to increase its fire prevention capacity. Tests will be made in accordance with ISO 5657 procedures for measuring fire ignition time, flame and shape variation of test pieces at the Building Material Test Institute. The test piece will be set up with horizontal levels having a constant radiation heat of $1{\sim}5W/cm^2$. Temperature transfers and increases from the surface into the interior. Combustible gases result due to pyrolysis, and regular contact is maintained between the fire source and the center of the test piece for assessment purposes. Ignition has not been occurred without adding retardant meaning that there is almost no possibility of ignition of waste tire particle. This fact can be considered as fire load to appreciate a volume of combustion materials. Flame is not occurred due to heat-absorbing effect by adding non-organic series retardant into waste tire particle. Conclusions have been summarized as follows; 1) Combustion of building material can be decreased by adding retardant to waste tire-mixing mortar. But compressive strength and insulation capacity of the material should be measured later. 2) Firing prevention and ignition are main points of building fire. Reasonable fire engineering assessment of interior material should be made for establishing effective disaster prevention system.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

Feasibility Study on Use of Livestock Manure as Solid Refuse Fuel by Torrefaction Method (반탄화 기술을 이용한 가축분뇨의 고형연료화 가능성 연구)

  • Lee, Yongho;Sanjusren, Oyun-Erdene;Pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.560-571
    • /
    • 2019
  • In the study, used torrefaction method to make sample from organic waste of livestock manure for Biomass-solid refuse fuel feasibility study of torrefied materials. Fallen leaves and sawdust added in torrefaction methods with livestock manure, that additives were used to improve the lower calorific value of livestock manure. During the torrefaction experiment, the reaction temperature was varied from $200^{\circ}C$ to $260^{\circ}C$ and $20^{\circ}C$ to prepare a sample. The reaction time was divided into 15, 30 and 45min to determine the effect of the experimental conditions on the torrified products. The additives were mixed at a ratio of 9:1 and 8:2 (Cow manure: additive) relative to the livestock manure. Through this experiment, it was obtained 3,500 kcal/kg standard product of solid fuel produced in Korea and improved product was obtained by adding additives.

Proposal for Ignition Source and Flammable Material Safety Management through 3D Modeling of Hazardous Area: Focus on Indoor Mixing Processes (폭발위험장소 구분도의 3D Modeling을 통한 점화원 및 가연물 안전관리 방안 제안: 실내 혼합공정을 중심으로)

  • Hak-Jae Kim;Duk-Han Kim;Young-Woo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 2024
  • Purpose: This study aims to propose measures for the prevention of fire and explosion accidents within manufacturing facilities by improving the existing classification criteria for hazardous locations based on the leakage patterns of flammable liquids. The objective is to suggest ways to safely manage ignition sources and combustible materials. Method: The hazardous locations were calculated using "KS C IEC 60079-10-1," and the calculated explosion hazard distances were visualized in 3D. Additionally, the formula for the atmospheric dispersion of flammable vapors, as outlined in "P-91-2023," was utilized to calculate the dispersion rates within the hazardous locations represented in 3D. Result: Visualization of hazardous locations in 3D enabled the identification of blind spots in the floor plan, facilitating immediate recognition of ignition sources within these areas. Furthermore, when calculating the time taken for the Lower Explosive Limit (LEL) to reach within the volumetric space of the hazardous locations represented in 3D, it was found that the risk level did not correspond identically with the explosion hazard distances. Conclusion: Considering the atmospheric dispersion of flammable liquids, it was concluded that safety management should be conducted. Therefore, a method for calculating the concentration values requiring detection and alert based on realistically achievable ventilation rates within the facility is proposed.

The Effects of Solidified Sewage Sludge as a Soil Cover Material for Cultivation of Bioenergy Crops in Reclaimed Land (에너지작물 재배를 위한 간척지 토양의 토양복토재로써 하수슬러지 고화물의 이용효과)

  • An, Gi-Hong;Koo, Bon-Cheol;Choi, Yong-Hwan;Moon, Youn-Ho;Cha, Young-Lok;Bark, Surn-Teh;Kim, Jung-Kon;Yoon, Yong-Mi;Park, Kwang-Guen;Kim, Jang-Taeck
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.3
    • /
    • pp.238-247
    • /
    • 2012
  • To determine the possibility of solidified se wage sludge for use as a soil cover material in reclaimed land, the growth of energy crops and soil chemical properties investigated in each experimental plots during 2 years (2010 and 2011). The experimental plots consisted of the mixing with solidified sewage sludge plot (SS50), the covering with solidified sewage sludge plot (SS100), and the original reclaimed land plot (ORL) on reclaimed land for the intended landfill in Sudokwon Landfill Site Management Corporation (SLC). Plant height, measured in the second year (2011), was highest in the Geodae 1 grown at plots treated with solidified sewage sludge. The growth of energy crops cultivated in both SS50 and SS100 were better than in ORL. The contents of organic matter (OM) and total nitrogen (T-N) at both SS50 and SS100 were considerably higher than that of the ORL over 2 years. However, the soil from ORL showed higher salinity with high contents of exchangeable $Na^+$ cation than that of SS50 and SS100 over 2 years. We consider that soil chemical and physical properties on reclaimed land used in this study could be improved by the application of solidified sewage sludge due to following reasons. Firstly, the application of solidified sewage sludge may provide soil nutrients on reclaimed land i.e. the growth of energy crops better than in ORL, resulted in more OM and T-N contents in SS50 and SS100. Secondly, the top layers mixed or covered with solidified sewage sludge on reclaimed land may be prevented the salinity accumulation due to capillary rise to surface soil, and improved the cultivation layer for effectively propagating the rhizomes of energy crops. Thus the solidified sewage sludge may be a great soil cover materials for cultivation of bioenergy crops in reclaimed land.

Thermal Conductivity and Pore Characteristics of Low-Temperature Sintered Lightweight Aggregates Mode from Waste Glass and Bottom Ash (바텀애쉬와 폐유리를 사용하여 제조한 저온소성 경량골재의 열전도율과 기공특성)

  • Lee, Han-Baek;Ji, Suk-Won;Seo, Chee-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.851-858
    • /
    • 2010
  • In this study, waste glass and bottom ash were used as basic materials in order to secure a recycling technology of by-products which was mostly discarded and reclaimed. In addition, because softening point of waste glass is less than $700^{\circ}C$ and bottom ash includes combustible material, it was possible to manufacture low-temperature sintering lightweight aggregates for energy saving at $800{\sim}900^{\circ}C$ that it is as much as 20~30% lower than sintering temperature of existing lightweight aggregates. Thermal conductivity of newly-developed lightweight aggregates was 0.056~0.105W/m. K and its porosity was 40.36~84.89%. A coefficient of correlation between thermal conductivity and porosity was -0.97, it showed very high negative correlationship. With this, we were able to verify that porosity is key factor to affect thermal conductivity. Microstructure of lightweight aggregates by $CaCO_3$ content and replacement ratio of bottom ash in the variation of temperature were that $CaCO_3$ content increased along with pore size while replacement ratio of bottom ash increased as pore size decreased. Specially, most pores were open pore instead of closed pore of globular shape when replacement ratio of bottom ash was 30%, and pore size was small about 1/10~1/5 as compared with case in bottom ash 0~20%. In addition, open pore shapes were remarkably more irregular form of open pore in $900^{\circ}C$ than $700^{\circ}C$ or $800^{\circ}C$ when replacement ratio of bottom ash was 30%. We reasoned hereby that these results will influence on absorption increase, strength and thermal conductivity decrease of lightweight aggregates.