• 제목/요약/키워드: Combined-Array

검색결과 219건 처리시간 0.027초

Activities of East Asian VLBI network

  • Kobayashi, Hideyuki;Wajima, Kiyoaki;Hada, Yasuhiro;Shen, Zhiqiang;Honma, Mareki;Fujisawa, Kenta;Byon, Do-Young;Matsushita, Satoki
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.59.3-59.3
    • /
    • 2017
  • We will present the activities of East Asian VLBI Network, EAVN, which consists of around 20 radio telescopes in Japan, Korea, and China with 6,500 km extend. It is a most sensitive and highest VLBI array in the world. We have conducted science verification observations at mainly 8 and 22 GHz. And Japanese VLBI array, VERA, and Korean VLBI array, KVN have combined as KaVA, Korean and VERA Array, and started science observations with open use at 22 and 43 GHz. We will presents some commissioning and science results based on it. Moreover Taiwan is constructing the Greenland telescope to be a millimeter and submillimeter VLBI station, which will be a very powerful station in Global millimeter and submillimeter VLBI array. These activities will be introduced as well.

  • PDF

Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI

  • Ryu, Yeun Chul
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.238-243
    • /
    • 2017
  • In this research, we report the preliminary results of an insertional type parallel transmission (pTx) array that has 7-elements that are placed in the space above a patient table as a transmit (Tx) coil to give an RF transmission ($B_1{^+}$) field for the body object of a 3 Tesla (T) MRI system. In previous research, we have tried to compare the performances of different coil elements and array geometries for a pTx body image. Based on these results, we attempt to obtain a human image with the proposed pTx array. Through the simulation and experimental results, we introduce a possible structure of multi-channel Tx array and verify the utility of a multi-channel Tx body image using $B_1{^+}$ shimming. The insertional pTx array, combined with a receiver (Rx) array coil, provides an enhanced $B_1{^+}$ field homogeneity in a large ROI image as a result of $B_1{^+}$ shimming applied over the full body size object. Through this research, we hope to determine the usefulness of the proposed insertional type RF coil combination for 3 T body imaging.

유한요소법과 하이브리드형 무한요소법의 결합에 의한 축대칭 변환기의 음향 특성해석(II) ;광대역 배열 변환기의 설계 및 그 음향특성 (Acoustic Characteristics Analysis of the Axi-symmetric Transducer by the combined Finite Element Method and Hybrid Type Infinite Element Method, Part II : Wideband Array Transducer Design and its Acoustic Characteristics)

  • 김천덕;김원호;김대환;윤종락
    • 한국음향학회지
    • /
    • 제13권2호
    • /
    • pp.68-75
    • /
    • 1994
  • 본 논문은 두 편으로 연결된 논문의 둘째편으로 광대역 배열변환기의 설계방법과 설계된 변환기의 음향특성을 제시한다. 아울러 유한요소법과 하이브리드형 무한요소법의 결합기법에 의한 설계된 변환기의 음향특성 결과가 등가회로 해석 기법에 의한 결과보다 양호함을 확인하였다. 따라서 제시된 변환기 해석기법이 광대역 배열 변환기의 설계 및 음향특성 해석에 응용될 수 있을 것으로 판단된다.

  • PDF

Investigation of nuclear material using a compact modified uniformly redundant array gamma camera

  • Lee, Taewoong;Kwak, Sung-Woo;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.923-928
    • /
    • 2018
  • We developed a compact gamma camera based on a modified uniformly redundant array coded aperture to investigate the position of a $UO_2$ pellet emitting characteristic X-rays (98.4 keV) and ${\gamma}-rays$ (185.7 keV). Experiments using an only-mask method and an antimask subtractive method were conducted, and the maximum-likelihood expectation maximization algorithm was used for image reconstruction. The images obtained via the antimask subtractive method were compared with those obtained using the only-mask method with regard to the signal-to-noise ratio. The reconstructed images of the antimask subtractive method were superior. The reconstructed images of the characteristic X-rays and the ${\gamma}-rays$ were combined with the obtained image using the optical camera. The combined images showed the precise position of the $UO_2$ pellet. According to the self-absorption ratios of the nuclear material and the minimum number of effective events for image reconstruction, we estimated the minimum detection time depending on the amount of nuclear material.

Distance Extraction by Means of Photon-Counting Passive Sensing Combined with Integral Imaging

  • Yeom, Seok-Won;Woo, Yong-Hyen;Baek, Won-Woo
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.357-361
    • /
    • 2011
  • Photon-counting sensing is a widely used technique for low-light-level imaging applications. This paper proposes a distance information extraction method with photon-counting passive sensing under low-lightlevel conditions. The photo-counting passive sensing combined with integral imaging generates a photon-limited elemental image array. Maximum-likelihood estimation (MLE) is used to reconstruct the photon-limited image at certain depth levels. The distance information is extracted at the depth level that minimizes the sum of the standard deviation of the corresponding photo-events in the elemental image array. Experimental and simulation results confirm that the proposed method can extract the distance information of the object under low-light-level conditions.

직접법과 반복법(LMS법)의 합성 알고리즘을 이용한 직선배열 점음원의 적응 지향성 합성 SIMULATION (Adaptive directivity synthesis simulation of point source array using algorithm combined directive and recursive method(LMS method))

  • 조기량
    • 한국통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1453-1462
    • /
    • 1996
  • A numerical simulation is carried out on the directiveity synthesis of ultrasonic transducers by point source array. Directive method with combined LMS(Least-Mean-Square) method is practiced by means of a iterative method to realize the desired directivity. The directiviey of quasi-ideal beam with a beam width and a directive arbitrary specified was chosen. On the numerical resut, Proposed algorithm shows higher speed of clculating simulation than that of LMS method, and make adaptive control, which enables the desired directivity. Numerical simulations are carried out by PC(CPU:80486 DX2, RAM 16Mbyte).

  • PDF

High-Resolution Microarrays for Mapping Promoter Binding sites and Copy Number Variation in the Human Genome

  • Albert Thomas
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2006년도 Principles and Practice of Microarray for Biomedical Researchers
    • /
    • pp.125-126
    • /
    • 2006
  • NimbleGen has developed strategies to use its high-density oligonucleotide microarray platform (385,000 probes per array) to map both promoter binding sites and copy number variation at very high-resolution in the human genome. Here we describe a genome-wide map of active promoters determined by experimentally locating the sites of transcription imitation complex binding throughout the human genome using microarrays combined with chromatin immunoprecipitation. This map defines 10,567 active promoters corresponding to 6,763 known genes and at least 1,196 un-annotated transcriptional units. Microarray-based comparative genomic hybridisation (CGH) is animportant research tool for investigating chromosomal aberrations frequently associated with complex diseases such as cancer, neuropsychiatric disorders, and congenital developmental disorders. NimbleGen array CGH is an ultra-high resolution (0.5-50 Kb) oligo array platform that can be used to detect amplifications and deletions and map the associated breakpoints on the whole-genome level or with custom fine-tiling arrays. For whole-genome array CGH, probes are tiled through genic and intergenic regions with a median probe spacing of 6 Kb, which provides a comprehensive, unbiased analysis of the genome.

  • PDF

Laser Generation of Focused Lamb Waves

  • Jhang, Kyung-Young;Kim, Hong-Joon;Kim, Hyun-Mook;Ha, Job
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.637-642
    • /
    • 2002
  • An arc-shaped line array slit has been used for the laser generation of focused Lamb waves. The spatially expanded Nd:YAG pulse laser was illuminated through the arc-shaped line array slit on the surface of a sample plate to generate the Lamb waves of the same pattern as the slit. Then the generated Lamb waves were focused at the focal point of which distance from the slit position is dependent on the curvature of slit arc. The proposed method showed better spatial resolution than the conventional linear array slit in the detection of laser machined linear defect and drill machined circular defect on aluminum plates of 2mm thickness. Using the focused waves, we could detect the linear defect and the circular defect with the improvement of spatial resolution. The method can also be combined with the scanning mechanism to get an image just like by the scanning acoustic microscope(SAM).

Array Antenna Design for Ku-Band Terminal of L.E.O Satellite Communication

  • Kang, Seo;Kang, JeongJin;Rothwell, Edward J.
    • International journal of advanced smart convergence
    • /
    • 제11권4호
    • /
    • pp.41-46
    • /
    • 2022
  • This study is a Ku-band array antenna for the manufacture of low-orbit satellite communication terminals, designed to have miniaturization, high gain, and wide beam width. The transmission of low-orbit satellite communication has a right-rotating circularly polarized wave, and the reception has a left-rotating circularly polarized wave. The 4×8 array antenna was separated for transmission and reception, and it was combined with the RF circuit part of the transmitter and receiver, and was terminated in the form of a waveguide for RF signal impedance matching in the form of a transition from the microstrip line to the waveguide. The 30° beam width of the receiver maximum gain of 19 dBi and the 29° beam width of the transmitter maximum gain of 18 dBi are shown. Through this antenna configuration, the system was configured to suit the low-orbit satellite transmission/reception characteristics.

Polydeoxyribonucleotide and Microlens Array-type, Nanosecond-domain Neodymium:Yttrium-aluminum-garnet Laser Treatment for Scars from Costal Cartilage Harvest Surgery: Case Series of 9 Patients

  • Ahn, Keun Jae;Kim, Do Yeon;Cheon, Gwahn-Woo;Park, Hyun Jun;Ahn, Tae Hwan
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.90-95
    • /
    • 2021
  • Background and Objectives Surgery for harvesting costal cartilage is often required for revision septorhinoplasty due to a lack of septal cartilage in patients with a severely contracted nose, and postoperative scarring on the anterolateral rib cage commonly requires additional treatment. This study aimed to evaluate the therapeutic efficacy and safety of combined polydeoxyribonucleotide (PDRN) and microlens array (MLA)-type nanosecond-domain neodymium (Nd):yttrium-aluminum-garnet (YAG) laser treatment for postoperative scars after costal cartilage harvest surgery. Materials and Methods Nine Korean patients with scars after costal cartilage harvest surgery treated with PDRN injections and MLA-type Nd:YAG laser treatments were retrospectively reviewed. Results Most of the scar lesions exhibited clinical improvement at 2 weeks after PDRN and MLA-type nanosecond-domain laser treatments, and the lesions further improved after adding more treatment sessions. The median Vancouver Scar Scale (VSS) score decreased from 6 (interquartile range [IQR]: 6-7) before combined intralesional PDRN injection and MLA-type, nanosecond-domain Nd:YAG laser treatments to 3 (IQR: 2-4) thereafter. Patient satisfaction after the combination treatments was rated as satisfactory. None of our patients reported major adverse events. Conclusion This case series study demonstrated that combined PDRN and MLA-type, nanosecond-domain Nd:YAG laser treatments are effective and safe for treating scars from costal cartilage harvest surgery.