• Title/Summary/Keyword: Combined test

Search Result 2,638, Processing Time 0.031 seconds

A Study on Properties of Pb-free Solder Joints Combined Sn-Bi-Ag with Sn-Ag-Cu by Conditions of Reflow Soldering Processes (리플로우 솔더링 공정 조건에 따른 Sn-Bi-Ag와 Sn-Ag-Cu 복합 무연 솔더 접합부 특성 연구)

  • Kim, Jahyeon;Cheon, Gyeongyeong;Kim, Dongjin;Park, Young-Bae;Ko, Yong-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.3
    • /
    • pp.55-61
    • /
    • 2022
  • In this study, properties of Pb-free solder joints which were combined using Sn-3.0Ag-0.5Cu (SAC305) Pb-free solder with a mid-temperature type of melting temperature and Sn-57Bi-1Ag Pb-free solder with a low-temperature type of melting temperature were reported. Combined Pb-free solder joints were formed by reflow soldering processes with ball grid array (BGA) packages which have SAC305 solder balls and flame retardant-4 (FR-4) printed circuit boards (PCBs) which printed Sn-57Bi-1Ag solder paste. The reflow soldering processes were performed with two types of temperature profiles and interfacial properties of combined Pb-free solder joints such as interfacial reactions, formations of intermetallic compounds (IMCs), diffusion mechanisms of Bi, and so on were analyzed with the reflow process conditions. In order to compare reliability characteristics of combined Pb-free solder joints, we also conducted thermal shock test and analyzed changes of mechanical properties for joints from a shear test during the thermal shock test.

Management Plan on Test Track of Advanced EMU System (차세대전동차 시스템 시험선 운영 방안)

  • Lee, H.M.;Kim, G.D.;Park, S.H.;Oh, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1036-1037
    • /
    • 2008
  • Test track of the Advanced EMU system will be developed and organically combined with technologies of power supply system, signal communication system and track structure. The purpose of the test track is a acquirement of reliability and stability through a sufficient performance test. Therefore, this paper draws up all management plans for tests of the Advanced EMU system.

  • PDF

Effect of Co-existence of Carbofuran and Chlorothalonil on the Short-term Bioconcentration Factor in Brachydanio rerio(zebrafish) (Carbofuran과 Chiorothalonil의 공존이 Brachydanio rerio(zebrafish)를 이용한 단기간 생물농축계수의 측정에 미치는 영향)

  • 민경진;차춘근
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.64-71
    • /
    • 1997
  • This study was performed to investigate the effect of co-existence of carbofuran and chlorothalonil on the short-term bioconcentration factor in Brachydanio rerio(zebrafish). The fishes were exposed to the single and combined treatment of carbofuran and chlorothalonil for 1, 3 and 5 days. Experimental concentrations of carbofuran were 0.05 and 0.10 ppm under the single treatment. And those of chlorothalonil were 0.005 and 0.010 ppm. Experimental concentrations of the combined treatment of carbofuran and chlorothalonil were 0.05 ppm+0.005 ppm, 0.05 ppm+0.010 ppm, 0.10 ppm+0.005 ppm for 1, 3 and 5 days, respectively. Carbofuran and chlorothalonil in fish and in test water were extracted with n-hexane and acetonitrile. GC-ECD was used to detect and quantitate carbofuran and chlorothalonil. 1-day, 3-day and 5-day bioconcentration factors(BCF$_1$, BCF$_3$ and BCF$_5$) of each pesticide were obtained from the quantitation results. The depuration rate of each pesticide was determined over the 24-h period after combined treatment. The results were as follows: Carbofuran did not bioaccumulate in zebrafish under the single and combined treatment for testing periods. BCF$_1$ values of chlorothalonil in concentration of 0.005 and 0.010 ppm under the single treatment were 0.508, 0.621, BCF$_3$ were 1.327, 1.511 and BCF$_5$ were 1.331, 1.597, respectively. BCF$_1$ values of chlorothalonil were 0.512, 0.520 and 0.619, respectively, when the concentration of carbofuran and chlorothalonil in combined treatment were 0.05+0.005, 0.05+0.010 and 0.10+0.005 ppm. BCF$_3$ values of chlorothalonil 1.341, 1.338 and 1.513, respectively, and BCF$_5$ values of chlorothalonil were 1.332, 1.327 and 1.521, respectively, under the above combined treatment. Depuration rate constants of chlorothalonil in concentration of 0.005 and 0.010 ppm under the single treatment were 0.011 and 0.012. Depuration rate constants of chlorothalonil were 0.011, 0.010 and 0.011, when the concentration of carbofuran and chlorothalonil in combined treatment were 0.05+0.005, 0.05+0.010 and 0.10+0.005 ppm. It was observed that no significant difference of carbofuran and chlorothalonil concentration in fish extracts, test water, BCFs and depuration rate constants of carbofuran and chlorothalonil between combined treatment and single treatment. It was considered that no appreciable interaction at experimental concentrations due to lower concentrations than LC$_{50}$. It is suggested that the difference of BCFs between carbofuran and chlorothalonil due to those of fat composition of fish and solubility of carbofuran and chlorothaionil.

  • PDF

Bearing capacity of shallow footing under combined loading

  • Kusakabe, Osamu;Takeyama, Tomohide
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.3-25
    • /
    • 2010
  • The paper deals with two bearing capacity problems of shallow footing under combined loading. The first is a FEM study of shallow strip footing on two-layer clay deposits subjected to a vertical, horizontal and moment combined loading, while the second is a centrifuge study of shallow rectangular footing on dry sand under double eccentricity. The FEM results revealed that the existence of top soft layer sensitively affects more on horizontal and moment capacity than vertical capacity for cases of footing on soft clay overlying stiff clay. Practical design charts are presented to evaluate bearing capacities of footing for various combinations of the ratio of the depth of the upper layer to the footing width and the ratio of undrained strength of the upper layer to that of the lower. The centrifuge tests indicated that current design practice of calculating failure load of rectangular surface footing under double eccentricity underestimates the centrifuge loading test data. This trend is more marked when the eccentricity becomes larger. The decreasing trend in failure load with an increase of double eccentricity is rather uniquely expressed by a single curve, using a newly defined resultant eccentricity and the diagonal length of the footing base.

  • PDF

Performance Improvement of Oil Pump by Design of Gerotor (Combined Profile - Two Ellipses) and Port (지로터(2개의 타원 조합) 형상 및 포트 설계를 통한 오일펌프 성능인자 향상)

  • Kwak, Hyo Seo;Li, Sheng Huan;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.3
    • /
    • pp.207-216
    • /
    • 2016
  • A gerotor is suitable for miniature manufacturing because it has high discharge per 1 cycle and a simple structure, while also being widely used for lubrication oil of engines and as a hydraulic source of automatic transmission. In the automobile industry, improvements in fuel efficiency and noise reduction have recently come to the fore. It has also been necessary to continuously improve the flow rate and noise of internal gear pumps for better fuel efficiency through optimal gerotor and port shape design. In this study, to develop an optimal gerotor with a new lobe shape, 2-ellipses-combined, the equation of the lobe shape was derived, and CFD analysis results were compared for 2-ellipses with those of the previous gerotors (3-ellipses and ellipse1-involuteellipse2). A performance test for the oil pump with the optimal rotor (2-ellipses) was carried out and showed good agreement with the results obtained from CFD analysis.

Seismic behavior of steel reinforced concrete cross-shaped column under combined torsion

  • Chen, Zongping;Liu, Xiang
    • Steel and Composite Structures
    • /
    • v.26 no.4
    • /
    • pp.407-420
    • /
    • 2018
  • Experiments were performed to explore the hysteretic performance of steel reinforced concrete (SRC) cross-shaped columns. Nine specimens were designed and tested under the combined action of compression, flexure, shear and torsion. Torsion-bending ratio (i.e., 0, 0.14, 0.21) and steel forms (i.e., Solid - web steel, T - shaped steel, Channel steel) were considered in the test. Both failure processes and modes were obtained during the whole loading procedure. Based on experimental data, seismic indexes, such as bearing capacity, ductility and energy dissipation were investigated in detail. Experimental results suggest that depending on the torsion-bending ratio, failure modes of SRC cross-shaped columns are bending failure, flexure-torsion failure and torsion-shear failure. Shear - displacement hysteretic loops are fuller than torque - twist angle hysteretic curves. SRC cross-shaped columns exhibit good ductility and deformation capacity. In the range of test parameters, the existence of torque does not reduce the shear force but it reduces the displacement and bending energy dissipation capacity. What is more, the bending energy dissipation capacity increases with the rising of displacement level, while the torsion energy dissipation capacity decreases.

Structural performance of cold-formed steel column bases with bolted moment connections

  • Chung, K.F.;Yu, W.K.;Wang, A.J.
    • Steel and Composite Structures
    • /
    • v.5 no.4
    • /
    • pp.325-340
    • /
    • 2005
  • This paper presents a thorough investigation into the structural performance of cold-formed steel column bases using double lipped C sections with bolted moment connections. A total of four column base tests with different connection configurations were carried out, and it was found that section failure under combined bending and shear was always critical. Moreover, the proposed column bases were demonstrated to be structurally efficient attaining moment resistances close to those of the connected sections. In order to examine the structural behaviour of the column base connections, a finite element model was established using shell and spring elements to model the sections and the bolted fastenings respectively. Both material and geometrical non-linearities were incorporated, and comparison between the test and the numerical results was presented in details. The design rules originally developed for bolted moment connections between lapped Z sections were adopted and re-formulated for the design of column base connections after careful calibration against the test data. Comparison on co-existing moments and shear forces at the critical cross-sections of the column bases was fully presented. It was shown that the proposed design and analysis method was structurally adequate to predict the failure loads under combined bending and shear for column bases with similar connection configurations.

Structural performance of cold-formed steel column bases with bolted moment connections

  • Chung, K.F.;Yu, W.K.;Wang, A.J.
    • Steel and Composite Structures
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2005
  • This paper presents a thorough investigation into the structural performance of cold-formed steel column bases using double lipped C sections with bolted moment connections. A total of four column base tests with different connection configurations were carried out, and it was found that section failure under combined bending and shear was always critical. Moreover, the proposed column bases were demonstrated to be structurally efficient attaining moment resistances close to those of the connected sections. In order to examine the structural behaviour of the column base connections, a finite element model was established using shell and spring elements to model the sections and the bolted fastenings respectively. Both material and geometrical non-linearities were incorporated, and comparison between the test and the numerical results was presented in details. The design rules originally developed for bolted moment connections between lapped Z sections were adopted and re-formulated for the design of column base connections after careful calibration against the test data. Comparison on co-existing moments and shear forces at the critical cross-sections of the column bases was fully presented. It was shown that the proposed design and analysis method was structurally adequate to predict the failure loads under combined bending and shear for column bases with similar connection configurations.

Effects of Combined Environmental Factors on Mechanical and Thermal Analysis Properties of Graphite/Epoxy Composites (복합적인 환경인자가 탄소섬유강화 복합재의 기계적 및 열분석 특성에 미치는 영향)

  • Lee, Sang-Jin;Lee, Jong-Keun;Yoon, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1416-1425
    • /
    • 2002
  • In this study, the effects of combined environmental factors on mechanical and thermal analysis properties of graphite/epoxy composites were evaluated by the use of an accelerated aging test. Environmental factors such as temperature, moisture. and ultraviolet were considered. A xenon-arc lamp was utilized for ultraviolet light. and exposure times of up to 3000 hours were applied. Several types of specimens - tensile. bending, and shear specimens those are transverse to the fiber direction, and bending specimens those are parallel to the tiber direction - were used to investigate the effects of environmental factors on mechanical properties of the composites. Also, glass transition temperature, storage shear modulus, loss shear modulus, and tan ${\delta}$ were measured as a function of exposure times through a dynamic mechanical analyzer. In addition. a suitable testing method for determining the effect of environmental factors on mechanical properties is suggested by comparing the results from using two different types of strain measuring sensors. Finally, composite surfaces exposed to environmental factors were examined using a scanning electron microscope.

Rotary compressor with combined vane and roller (베인-롤러 일체형 로타리 압축기)

  • Ahn, Jong-Min;Kim, Hyun-Jin;Kang, Seoung-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.904-909
    • /
    • 2009
  • In this paper, a rolling piston rotary compressor having a combined vane and roller unit has been introduced. In a conventional rotary compressor, sliding motion takes place between the vane nose and roller. By combining the vane and the roller in one unit, gas leakage through a clearance between the vane nose and the roller can be eliminated, and the frictional loss between them can also be reduced to almost nought. Compressor model with the combined vane and roller has been fabricated and tested in a compressor calorimeter and computer simulation program has been developed to confirm merits of the new mechanism. In a test, cooling capacity has been found to be increased by 1.4%, and the compressor input decreased by 0.3%, resulting in 1.7% increased in EER. Simulation program confirmed the calorimeter test results and the merits of the new model as mentioned above.

  • PDF