DOI QR코드

DOI QR Code

Structural performance of cold-formed steel column bases with bolted moment connections

  • Chung, K.F. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University) ;
  • Yu, W.K. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University) ;
  • Wang, A.J. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
  • Received : 2004.11.03
  • Accepted : 2005.01.24
  • Published : 2005.08.25

Abstract

This paper presents a thorough investigation into the structural performance of cold-formed steel column bases using double lipped C sections with bolted moment connections. A total of four column base tests with different connection configurations were carried out, and it was found that section failure under combined bending and shear was always critical. Moreover, the proposed column bases were demonstrated to be structurally efficient attaining moment resistances close to those of the connected sections. In order to examine the structural behaviour of the column base connections, a finite element model was established using shell and spring elements to model the sections and the bolted fastenings respectively. Both material and geometrical non-linearities were incorporated, and comparison between the test and the numerical results was presented in details. The design rules originally developed for bolted moment connections between lapped Z sections were adopted and re-formulated for the design of column base connections after careful calibration against the test data. Comparison on co-existing moments and shear forces at the critical cross-sections of the column bases was fully presented. It was shown that the proposed design and analysis method was structurally adequate to predict the failure loads under combined bending and shear for column bases with similar connection configurations.

Keywords

References

  1. ABAQUS. (2004), User's Manual, Version 6.4. Hibbitt, Karlsson and Sorensen, Inc.
  2. American Iron and Steel Institute. (1996), AISI Specification for the design of cold-formed steel structural members. Washington (DC).
  3. British Standards Institution. (1998), BS5950: Structural use of steelwork in buildings: Part 5: Code of practice for the design of cold-formed sections. London.
  4. Chung, K.F. (1993), Building design using cold-formed steel sections: Worked examples to BS5950: Part 5: 1987. The Steel Construction Institute.
  5. Chung, K.F. and Ip, K.H. (2000),"Finite element modelling of bolted connections between cold-formed steel strips and hot rolled steel plates under shear", Eng. Struct., 22(10), 1271-1284. https://doi.org/10.1016/S0141-0296(99)00082-6
  6. Chung, K.F. and Ip, K.H. (2001),"Finite element investigation on the structural behaviour of cold-formed steel bolted connections", Eng. Struct., 23(9), 1115-1125. https://doi.org/10.1016/S0141-0296(01)00006-2
  7. Chung, K.F. and Lawson, R.M. (2000),"Structural performance of shear resisting connections among cold-formed steel members using web cleats of cold-formed steel strips", Eng. Struct., 22(10), 1350-1366. https://doi.org/10.1016/S0141-0296(99)00083-8
  8. Chung, K.F. and Lau, L. (1999),"Experimental investigation on bolted moment connections among cold-formed steel members", Eng. Struct., 21(10), 898-911. https://doi.org/10.1016/S0141-0296(98)00043-1
  9. Chung, K.F. and Ho, H.C. (2004),"Analysis and design of lapped connections between cold-formed steel Z sections", Thin-Walled Structures (submitted for publication).
  10. Chung, K.F. and Wong, M.F. (2001),"Experimental investigation of cold-formed steel beam-column sub-frames: enhanced performance", Proc. of the First Int. Conf. on Structural Engineering, Mechanics and Computation, Cape Town (South Africa), 1515-1522.
  11. Code of practice for the structural use of steel (Limit State approach): Draft 4.0 (2004). The Buildings Department, the Government of the Hong Kong SAR.
  12. Cold-formed steel structure code AS/NZ 4600: 1996. Sydney: Standards Australia/Standards New Zealand.
  13. Eurocode 3: Design of steel structures: Part 1.3: General rules -Supplementary rules for cold-formed thin gauge members and sheeting, ENV 1993-1-3. Brussels: European Committee for Standardization, 1996.
  14. Hancock, G.J. (1998), Design of Cold-Formed Steel Structures, 3rd ed. Australian Institute of Steel Construction.
  15. Ho, H.C. and Chung, K.F. (2004),"Experimental investigation into the structural behaviour of lapped connections between cold-formed steel Z sections", Thin-Walled Structures, 42(7), 1013-1033. https://doi.org/10.1016/j.tws.2004.03.022
  16. Lawson, R.M., Chung, K.F. and Popo-Ola, S.O. (2002), Building Design using Cold-formed Steel Sections, Structural Design to BS5950-5:1998 - Section properties and load tables, The Steel Construction Institute, SCI-P276, 1-234.
  17. Lim, J.B.P. and Nethercot, D.A. (2003),"Ultimate strength of bolted moment-connections between cold-formed steel members", Thin-Walled Structures, 41(11), 1019-1039. https://doi.org/10.1016/S0263-8231(03)00045-4
  18. Wheeler, A.T., Clarke, M.J. and Hancock, G.J. (1999),"Finite element modelling of eight bolt rectangular hollow section bolted moment end plate connections", Proc. of the Second Int. Conf. on Advances in Steel Structures, Hong Kong, Dec 1999, 237-244.
  19. Wong, M.F. and Chung, K.F. (2000a),"Experimental investigation of cold-formed steel beam-column sub-frames: Pilot Study", Proc. of the Fifteenth Int. Specialty Conf. on Cold-Formed Steel Structures, St. Louis (Missouri, USA), Oct 2000, 607-618.
  20. Wong, M.F. and Chung, K.F. (2000b),"Experimental investigation of cold-formed steel beam-column subframes: Comparative study", Proc. of the First Int. Conf. on Structural Stability and Dynamics, Taipei, Dec 2000, 587-592.
  21. Wong, M.F. and Chung, K.F. (2002),"Structural behaviour of bolted moment connections in beam-column subframes", J. Constructional Steel Research, 58(2), 253-274. https://doi.org/10.1016/S0143-974X(01)00044-X
  22. Yu, W.W. (2000), Cold-Formed Steel Design. 3rd ed. New York: John Wiley and Sons Inc.