• Title/Summary/Keyword: Combined procedures

Search Result 427, Processing Time 0.029 seconds

Comparison of resorbable plates and titanium plates for fixation stability of combined mandibular symphysis and angle fractures

  • Lim, Ho-Yong;Jung, Chang-Hwa;Kim, Seong-Yong;Cho, Jin-Yong;Ryu, Jae-Young;Kim, Hyeon-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.285-290
    • /
    • 2014
  • Objectives: We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures. Materials and Methods: Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received titanium plates while the experimental (R) group received resorbable plates. All procedures were carried out under general anesthesia using standard surgical techniques. We compared the frequency of wound dehiscence, development of infection, malocclusion, malunion, screw breakage, and any other technical difficulties between the two groups. Results: Thirteen patients were included in the R group, where 39 resorbable plates were applied. The T group consisted of 16 patients who received 48 titanium plates. The mean age in the R and T groups was 28.29 and 24.23 years, respectively. Primary healing of the fractured mandible was obtained in all patients in both groups. Postoperative complications were minor and transient. Moreover, there were no significant differences in the rates of various complications between the two groups. Breakage of 3 screws during the perioperative period was seen in the R group, while no screws or plates were broken in the T group. Conclusion: Resorbable plates can be used to stabilize combined mandibular angle and symphysis fractures.

Maxillary Sinus Augmentation Using Macroporous Biphasic Calcium Phosphate ($MBCP^{TM}$) : Three Case Report With Histologic Evaluation (합성골 이식재인 Macroporous biphasic calcium phosphate를 이용한 사람의 상악동 거상술-증례 보고)

  • Lee, Ji-Hyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.567-577
    • /
    • 2006
  • Background Several bone grafting materials have been used in sinus augmentation procedures. Macroporous Biphasic Calcium Phosphate($MBCP^{TM}$) consists of the mixture of 60% HA and 40% ${\beta}-TCP$. Therefore, it can provide good scaffold for the new bone to grow owing to HA, in the other hand, it can have bioactivity for bone remodeling owing to ${\beta}-TCP$. The purpose of this study was to evaluate bone formation following maxillary sinus augmentation using $MBCP^{TM}$ by means of histologic analysis. Material and Method $MBCP^{TM}$ was placed as a primary bone substitute for maxillary sinus augmentation. Three patients were selected after evalaution of their medical dental examination. $MBCP^{TM}$ only, $MBCP^{TM}$ combined with Irradicated cancellous bone and $MBCP^{TM}$ combined with autogenous bone were used for each patient. After about eight months, bone biopsies were harvested for histologic evaluation and fixtures installed. Results Eight months after surgery we observed new vital bone surrounding $MBCP^{TM}$ particle and the amount of new bone was about 30% even though there were discrepancies between specimens. This case report documents that $MBCP^{TM}$ when used as a grafting material for sinus floor augmentation whether combined other bone graft material or not, may lead to the predictable results for dental implants on posterior maxillary area with insufficient vertical height for fixture installation.

Estimation of Solid Sediments Load by Sewer and Land Surface for Maintenance of Combined Sewer Systems (합류식 관거 유지관리를 위한 하수 및 지표면 고형물 부하량 산정)

  • Lee Jae-Soo;Park Moo-Jong
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.533-544
    • /
    • 2006
  • The deposition of solids in combined sewer systems results in a loss of flow capacity that may restrict flow and cause a local flooding and enhanced solids deposition. In order to solve these problems and proper pipe management, estimation of solid loads from sewer and surface in a drainage basin is needed but this task is very difficult and extremely expensive. In this study, generalized procedures for estimating sewer solid loads during dry weather in combined sewer systems and for estimating solid loads on surface in a drainage basin developed by the U. S. Environmental Protection Agency were applied and analyzed in Gunja drainage basin in Korea. As result, the estimated solid loads from sewer and surface are 205.8,759kg/yr and 1,321,993kg/yr respectively, and total solid loads is 1,527,752kg/yr. The estimated solid removal from street cleaning, dredging from pipe system and pumping house is 1,486,636kg/yr. Therefore, the applied methods show resonable results. More reliable estimation can be achieved if long-term measurements and adjustment of estimation equations are carried out, and this estimation methods can be used usefully for the management of combined sewer system with reduction of cost and effort.

Clinical considerations for successful results in FOS(Functional Orthognathic Surgery): Surgery first orthodontic treatment later (임상가를 위한 특집 1 - 성공적인 선 수술 교정 치료를 위한 고려사항)

  • Oh, Chang-Ok
    • The Journal of the Korean dental association
    • /
    • v.50 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • The fundamental principles and the role of surgeons and orthodontists to produce successful results in orthodontic treatment combined with orthognathic surgery is not different from those of conventional procedures and FOS: surgery-first-orthodontic-treatment-later approach. The communication and cooperation between surgeon and orthodontist is of crucial importance. In FOS, the pre-surgical orthodontic preparation is not carried out in the patient's mouth, but in the mounted stone model and in addition to the simulation of tooth movement, to get a precise surgical occlusion, the entire steps of treatment should be simulated on the articulator as well. Right after the surgery, due to the instability of the occlusion, appropriate post operational care should be given according to the surgical technique applied to the mandible by use of final surgical wafer about 8 weeks.

Forearm Replantation for a Patient Presented with Major Amputation Injury: A Case Report

  • Jang, Jihoon;Lim, Kyoung Hoon;Kim, Joon-Woo;Kim, Hyung-Kee
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.187-190
    • /
    • 2016
  • With the development of safety measures for employees who work with dangerous machinery, the frequency of amputation injuries has been decreasing with resultant decrease in replantation procedures. However, in some patients with major amputation injury, replantation is still necessary for the preservation of limb and it's function. The replantation of the upper extremity (UE) is a complex and technically demanding surgical procedure. For the successful replantation of UE, the type of injury, reconstruction sequence, ischemic time, and other combined injury of patient should be considered. We report a case of major amputation of UE by guillotine-type injury and discuss the treatment process of this patient.

Characterizations of Two-step Matrix Application Procedures for Imaging Mass Spectrometry

  • Shimma, Shuichi
    • Mass Spectrometry Letters
    • /
    • v.6 no.1
    • /
    • pp.21-25
    • /
    • 2015
  • In this paper, I describe the importance of matrix spraying conditions in imaging mass spectrometry (IMS) to obtain successful imaging results. My developed matrix application methodology, which is a "two-step matrix application" sequentially combined with matrix sublimation and spraying matrix solution can provide high reproducibility and high ion yield compared with a conventional direct spraying method. However, insufficient IMS results were obtained occasionally despite the two-step method. Therefore, I wanted to characterize the methodology to continuously provide high quality data. According to my results, the sublimation time was not a strict parameter, and the most important step was the first spraying condition. This means that the extraction conditions from the tissue section and co-crystallization of the matrix were the most important factors.

A 3 Dimensional Characteristic Analysis of SLIM by the 2-D Finite Element Method (2차원 유한요소법에 의한 SLIM의 3차원적 특성 해석)

  • Cho, Yun-Hyun;Kim, Yong-Joo;Shin, Pan-Seok;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.37-42
    • /
    • 1990
  • In order to obtain optimal design criteria and operating parameters, a Single-sided Linear Induction Motor (SLIM) is analysed by using a 2-D finite element method with magnetic and current vector potential. In the analysing procedures, the governing equation is derived from Maxwell's equation combined with the magnetic vector potential. As a forcing term, 3-phase voltage source is employed using the Kirchhoff's voltage law in order to look into effects of the unbalanced 3-phase currents and air gap flux density. Also, 2ndary eddy current distribution, longitudinal end and transverse edge effects are in turns visualized by flux lines in 3 different analysing planes as functions of frequency and input power.

  • PDF

Treatment of dental implant-related maxillary sinusitis with functional endoscopic sinus surgery in combination with an intra-oral approach

  • Nam, Ki-Young;Kim, Jong-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.2
    • /
    • pp.87-90
    • /
    • 2014
  • The present report describes the case of a patient who underwent maxillary sinusitis right after dental implant installation with sinus lifting. Computed tomography scan revealed a dental implant (#16) was protruded inside the right maxillary sinus and confirmed the obstruction of ostium. A symptom remission was gained with the dual approaches combined by functional endoscopic sinus surgery and an intra-oral approach. Fully recovered function and healing of sinus were identified after 10 months follow-up. We report the case of sinusitis caused by protrusion of implants with sinus floor lift procedures and propose that practitioners should be aware of the possible its complications and management.

A Study on 3-D Landscape Modeling by Digital Photographic Images (항공사진영상에 의한 3차원경관모델링 실험)

  • Seok Jin-Chang;Lee Jun-Hyuk;Kim Yi-Ho;Lee Young-Jin
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.217-222
    • /
    • 2006
  • In this study, we performed three dimensional(3-D) modeling and simulation of terrain surfaces by using large scale aerial photographs. The objectives of this study are to use landscape analysis including 3-D database of built environments. The test area is selected around Olympic stadium located in Susung-gu, Daegu. A 1:5,000 scale of ortho-photo map is generated by photogrammetric procedures from 1:20,000 scale of aerial photographs, Digital Elevation Model (DEM) is also extracted from stereo aerial photographs or digital maps. The heights of buildings are determined using GPS control survey and aerial photographs in the test area, DEMs are extracted from the digital map. And then the two are combined three-dimensional changes of landscape views of buildings with terrain are simulated.

  • PDF

Total Facelift: Forehead Lift, Midface Lift, and Neck Lift

  • Park, Dong Man
    • Archives of Plastic Surgery
    • /
    • v.42 no.2
    • /
    • pp.111-125
    • /
    • 2015
  • Patients with thick skin mainly exhibit the aging processes of sagging, whereas patients with thin skin develop wrinkles or volume loss. Asian skin is usually thicker than that of Westerners; and thus, the sagging of skin due to aging, rather than wrinkling, is the chief problem to be addressed in Asians. Asian skin is also relatively large in area and thick, implying that the weight of tissue to be lifted is considerably heavier. These factors account for the difficulties in performing a facelift in Asians. Facelifts can be divided into forehead lift, midface lift, and lower face lift. These can be performed individually or with 2-3 procedures combined.