• 제목/요약/키워드: Combined environmental factors

검색결과 253건 처리시간 0.029초

배전용 폴리머애자 열화특성 평가를 위한 복합열화 시험장치 구축 (A Combined Aging Test Facility for Evaluating an Aging Characteristics of Distribution Polymer Insulators)

  • 이병성;한재홍;김찬영;윤태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1948-1950
    • /
    • 2000
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in an outdoor environment is still very limited. Especially, these insulators are subjected to the environmental stress such as ultraviolet radiation, electrical stress, mechanical load, etc.. Hence, in this paper, we simulated the factors having influence on aging of polymer insulators using the combined aging test chamber. In order to evaluate an aging characteristics with time, we measured leakage current on these insulators to make out the degree of aging.

  • PDF

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • 신재생에너지
    • /
    • 제2권3호
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

Carbofuran과 Chiorothalonil의 공존이 Brachydanio rerio(zebrafish)를 이용한 단기간 생물농축계수의 측정에 미치는 영향 (Effect of Co-existence of Carbofuran and Chlorothalonil on the Short-term Bioconcentration Factor in Brachydanio rerio(zebrafish))

  • 민경진;차춘근
    • 한국환경보건학회지
    • /
    • 제23권2호
    • /
    • pp.64-71
    • /
    • 1997
  • This study was performed to investigate the effect of co-existence of carbofuran and chlorothalonil on the short-term bioconcentration factor in Brachydanio rerio(zebrafish). The fishes were exposed to the single and combined treatment of carbofuran and chlorothalonil for 1, 3 and 5 days. Experimental concentrations of carbofuran were 0.05 and 0.10 ppm under the single treatment. And those of chlorothalonil were 0.005 and 0.010 ppm. Experimental concentrations of the combined treatment of carbofuran and chlorothalonil were 0.05 ppm+0.005 ppm, 0.05 ppm+0.010 ppm, 0.10 ppm+0.005 ppm for 1, 3 and 5 days, respectively. Carbofuran and chlorothalonil in fish and in test water were extracted with n-hexane and acetonitrile. GC-ECD was used to detect and quantitate carbofuran and chlorothalonil. 1-day, 3-day and 5-day bioconcentration factors(BCF$_1$, BCF$_3$ and BCF$_5$) of each pesticide were obtained from the quantitation results. The depuration rate of each pesticide was determined over the 24-h period after combined treatment. The results were as follows: Carbofuran did not bioaccumulate in zebrafish under the single and combined treatment for testing periods. BCF$_1$ values of chlorothalonil in concentration of 0.005 and 0.010 ppm under the single treatment were 0.508, 0.621, BCF$_3$ were 1.327, 1.511 and BCF$_5$ were 1.331, 1.597, respectively. BCF$_1$ values of chlorothalonil were 0.512, 0.520 and 0.619, respectively, when the concentration of carbofuran and chlorothalonil in combined treatment were 0.05+0.005, 0.05+0.010 and 0.10+0.005 ppm. BCF$_3$ values of chlorothalonil 1.341, 1.338 and 1.513, respectively, and BCF$_5$ values of chlorothalonil were 1.332, 1.327 and 1.521, respectively, under the above combined treatment. Depuration rate constants of chlorothalonil in concentration of 0.005 and 0.010 ppm under the single treatment were 0.011 and 0.012. Depuration rate constants of chlorothalonil were 0.011, 0.010 and 0.011, when the concentration of carbofuran and chlorothalonil in combined treatment were 0.05+0.005, 0.05+0.010 and 0.10+0.005 ppm. It was observed that no significant difference of carbofuran and chlorothalonil concentration in fish extracts, test water, BCFs and depuration rate constants of carbofuran and chlorothalonil between combined treatment and single treatment. It was considered that no appreciable interaction at experimental concentrations due to lower concentrations than LC$_{50}$. It is suggested that the difference of BCFs between carbofuran and chlorothalonil due to those of fat composition of fish and solubility of carbofuran and chlorothaionil.

  • PDF

복합열화 환경하에서 표면피복종류 및 피복두께에 따른 철근콘크리트의 부식특성 (Corrosion Properties of Reinforced Concrete with Types of Surface Cover and Covering Depth under the Combined Deterioration Environments)

  • 김무한;권영진;김용로;김재환;장종호;조봉석
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.119-126
    • /
    • 2004
  • Generally, reinforced concrete is one of the most commonly used structural materials and it prevents corrosion of steel bar by high pH of interior, But, as time elapsed, reinforced concrete structure become deteriorated by many of combined deterioration factors and environmental conditions. And, there are large number of deteriorate mechanism of the reinforced concrete structure and it acts complexly. It is recognized that steel bar corrosion is the main distress behind the present concern regarding concrete durability. In this study, to institute combined deterioration environments, established acceleration condition and cycle for combined deterioration environments has a resemblance to environments which are real structures placed. After that to confirm corrosion properties of reinforced concrete due to permeability with covering depth and types of surface cover under combined deterioration environments, measured carbonation velocity coefficients, chloride ion diffusion coefficients, water absorption coefficients, air permeability coefficients and electric potential, corrosion area ratio, weight reduction, corrosion velocity of steel bar. The results showed that an increase in age also decrease carbonation velocity coefficients, increase Chloride ion diffusion coefficients and increases water absorption coefficients. As well, an increase in age also increases corrosion of steel bar. Data on the development of corrosion velocity of steel bar with types of surface cover made with none, organic B, organic A, inorganic B, and inorganic A is shown. As well, permeability and corrosion velocity of steel bar with covering depth is superior to 10mm than 20mm. And it is confirmed permeability and corrosion properties of steel bar are closely related.

실내공간의 복합 환경 조건이 인체의 생리 및 심리반응에 미치는 영향 (The Combined Environmental Factors on the Human Physiological and Psychological Responses in Indoor Space)

  • 윤인
    • 한국산업융합학회 논문집
    • /
    • 제15권3호
    • /
    • pp.87-94
    • /
    • 2012
  • Kruithof demonstrated the preferred combination of illuminance levels and color temperatures. However, as Benett pointed out, difference of themal variables in such preference may be expected. The purpose of this study is to clarify the combined effects of lighting conditions(illuminance, color temperature), operative temperature on the human physiological and psychological responses. In order to observe operative temperature change in preference of color temperatures for three illumination levels, three subjects were exposed to two different conditions of color temperatures of 2,850K, 4,200K and 6,850K combined with operative temperatures(OT) of $25{\sim}31^{\circ}C$ at 100~1000lx. Thermal sensation vote and comfortable sensation vote, brightness perception vote were reported in each experiment conditions. The following results were obtained : 1) When illuminace level was at 100lx in operative temperatures of OT $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$, Color temperature affect not themal sensation but Warm-cool sensation. 2) Operative temperatures affect not brightness perception vote but visual comfort sensation vote, satisfactive sensation vote, warm-cool sensation vote and themal sensation vote.

Research on the influencing factors of new energy vehicles Based on VAM theory and Environmental awareness theory

  • Li, Wei-jia;Liu, Zi-Yang;Yang, Qiao
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권12호
    • /
    • pp.293-301
    • /
    • 2022
  • 본 연구는 소비자 행동 연구 프레임워크인 VAM 모델을 기반으로 환경 인식이라는 이타적 변수를 결합하여 지각된 가치, 지각된 위험 및 환경 보호 의식이 구매 의도에 영향을 미치는 연구 모델을 구축하여 지각된 가치 및 지각된 위험의 요인을 깊이 분석한다. 612개의 유효한 설문지를 수집하고 실증 분석을 수행한 결과는 지각된 유용성, 지각된 오락성, 기술성 및 환경 보호 의식이 모두 신에너지 차량 구매 의도에 뚜렷한 긍정적인 영향을 미치고 지각된 요금은 구매 의도에 부정적인 영향을 미치는 것으로 나타났다. 본 연구의 결과를 통해 기업의 마케팅 개선 전략을 제공하고 소비자 지각된 위험을 줄이며 기업이 신에너지 차량의 환경 보호 속성을 홍보하고 기업 자체의 환경 보호 노력을 촉진하는 데 유익한 보완을 제공하고 경제적 이익과 환경적 이익의 균형을 촉진할 수 있다.

Interaction of XRCC1 and XPD Gene Polymorphisms with Lifestyle and Environmental Factors Regarding Susceptibility to Lung Cancer in a High Incidence Population in North East India

  • Saikia, Bhaskar Jyoti;Phukan, Rup Kumar;Sharma, Santanu Kumar;Sekhon, Gaganpreet Singh;Mahanta, Jagadish
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권5호
    • /
    • pp.1993-1999
    • /
    • 2014
  • Background: This study aimed to explore the role of XRCC1 (Arg399Gln) and XPD (Lys751Gln) gene polymorphisms, lifestyle and environmental factors as well as their possible interactions in propensity to develop lung cancer in a population with high incidence from North East India. Materials and Methods: A total of 272 lung cancer cases and 544 controls were collected and XRCC1 (Arg399Gln) and XPD (Lys751Gln) genotypes were analyzed using a polymerase chain reaction based restriction fragment length polymorphism assay. Conditional multiple logistic regression analysis was used to calculate adjusted odds ratios and 95% confidence intervals after adjusting for confounding factors. Results: The combined Gln/Gln genotype of XRCC1 and XPD genes (OR=2.78, CI=1.05-7.38; p=0.040) was significantly associated with increased risk for lung cancer. Interaction of XRCC1Gln/Gln genotype with exposure of wood combustion (OR=2.56, CI=1.16-5.66; p=0.020), exposure of cooking oil fumes (OR=3.45, CI=1.39-8.58; p=0.008) and tobacco smoking (OR=2.54, CI=1.21-5.32; p=0.014) and interaction of XPD with betel quid chewing (OR=2.31, CI=1.23-4.32; p=0.009) and tobacco smoking (OR=2.13, CI=1.12-4.05; p=0.022) were found to be significantly associated with increased risk for lung cancer. Conclusions: Gln/Gln alleles of both XRCC1 and XPD genes appear to amplify the effects of household exposure, smoking and betel quid chewing on lung cancer risk in the study population.

모래지반에서 원형기초의 수직-수평 조합하중 지지력과 경사계수에 대한 수치해석 연구 (Numerical Studies on Combined VH Loading and Inclination Factor of Circular Footings on Sand)

  • 김동준;윤준웅;지성현;최재형;이진선;추연욱
    • 한국지반공학회논문집
    • /
    • 제30권3호
    • /
    • pp.29-46
    • /
    • 2014
  • 모래지반의 지표면에 위치한 거친 바닥면을 가진 강체 원형기초에 대하여 삼차원 수치해석을 통하여 수직-수평 조합하중 조건에서의 지지력을 구하였다. 조합하중 상관도를 효율적으로 산출할 수 있는 swipe 재하방법과 실제 구조물의 하중 조건과 유사한 probe 재하방법을 모사할 수 있는 수치모델을 구현하였으며 요소망의 조밀도에 의한 오차를 소거할 수 있는 분석 절차를 개발하였다. Mohr-Coulomb 소성모델을 사용하고 관련흐름법칙을 적용하여 지반의 내부 마찰각에 따른 수직-수평 조합하중에 대한 지지력 상관도와 경사계수를 산출하였다. Swipe 재하방법의 결과는 probe 재하방법을 사용한 결과와 유사함을 확인하였으며, 거친 바닥면 조건에서 수직-수평 조합하중 지지력 상관도의 내부 마찰각에 따른 변화는 미미하고, 원형기초에 대해서 연속기초 및 사각형기초와 동일한 경사계수를 적용할 수 있는 것으로 나타났다. 하중의 경사가 큰 경우에는 수치모델링을 통해 산출된 원형기초에 대한 지지력 상관도와 경사계수는 기존의 연구 결과보다 작게 평가되었으며, 수치모델링 결과에 영향을 미치는 요인과 향후 연구 방향에 대하여 고찰하였다.

The Magnitude of Mortality from Ischemic Heart Disease Attributed to Occupational Factors in Korea - Attributable Fraction Estimation Using Meta-analysis

  • Ha, Jae-Hyeok;Kim, Soo-Geun;Paek, Do-Myung;Park, Jung-Sun
    • Safety and Health at Work
    • /
    • 제2권1호
    • /
    • pp.70-82
    • /
    • 2011
  • Objectives: Ischemic heart disease (IHD) is a major cause of death in Korea and known to result from several occupational factors. This study attempted to estimate the current magnitude of IHD mortality due to occupational factors in Korea. Methods: After selecting occupational risk factors by literature investigation, we calculated attributable fractions (AFs) from relative risks and exposure data for each factor. Relative risks were estimated using meta-analysis based on published research. Exposure data were collected from the 2006 Survey of Korean Working Conditions. Finally, we estimated 2006 occupation-related IHD mortality. Results: For the factors considered, we estimated the following relative risks: noise 1.06, environmental tobacco smoke 1.19 (men) and 1.22 (women), shift work 1.12, and low job control 1.15 (men) and 1.08 (women). Combined AFs of those factors in the IHD were estimated at 9.29% (0.3-18.51%) in men and 5.78% (-7.05-19.15%) in women. Based on these fractions, Korea's 2006 death toll from occupational IHD between the age of 15 and 69 was calculated at 353 in men (total 3,804) and 72 in women (total 1,246). Conclusion: We estimated occupational IHD mortality of Korea with updated data and more relevant evidence. Despite the efforts to obtain reliable estimates, there were many assumptions and limitations that must be overcome. Future research based on more precise design and reliable evidence is required for more accurate estimates.

GIS를 활용한 폐기물 매립지의 적지분석 사례연구 (A Case Study on Suitability Analysis of Solid Waste Landfill Site utilizing GIS)

  • 이진덕;연상호;김성길
    • 한국지리정보학회지
    • /
    • 제3권4호
    • /
    • pp.33-49
    • /
    • 2000
  • 본 논문은 도시지역의 폐기물 매립지의 적지선정에 GIS기법을 적용한 사례연구를 제시한 것이다. 폐기물 매립지의 적지분석을 위한 여러 가지 평가인자들을 결정하고 데이터의 수집, 입력, 변환을 통하여 데이터베이스가 구축되었다. 또한 위성영상의 처리에 의해 대상지역의 최근 토지피복 분류와 식생활력도(NDVI) 데이터가 평가인자로서 GIS데이터에 통합되었다. 사회경제적 인자와 자연환경적 인자로 구분되는 1차 분류 평가인자들의 가중치를 이원비교법에 의해 결정된 2차분류 평가인자들의 가중치와 조합하여 분석하였다. 사례연구의 결과, 여러 가지 평가기준에 따른 적합성 분석이 가능하였으며, 사회경제적 인자를 중요하게 간주하는 관점에서 2차 분류 평가인자들의 가중치를 중요도에 따라 다르게 부여한 경우에서 가장 높은 적합도가 얻어졌다.

  • PDF