• 제목/요약/키워드: Combined Exposure

검색결과 363건 처리시간 0.036초

델파이 조사를 통한 직업적 소음 노출 규모의 추정 (Estimated Exposure Population to Hazardous Workplace Noise among Korean Workers)

  • 김승원;양선희;백용준;정태진;류향우;김은아
    • 한국산업보건학회지
    • /
    • 제28권4호
    • /
    • pp.416-424
    • /
    • 2018
  • Objective: The objective of this study was to estimate the numbers of employees occupationally exposed to noise according to their industry and size. Methods: A Delphi panel consisting of 15 occupational health experts estimated the exposure prevalence of noise in workplace. Data on Industrial Accident Compensation Insurance provided from Occupational Safety and Health Research Institute were combined to produce the exposure population. Results: In Korea, 16.0% of employees, 2,539,890 out of 15,838,926, was estimated to exposed to noise occupationally. The rate was 32.7% and 10.3% in manufacturing sector and non-manufacturing sector, respectively. The highest rate, 52.5%, was found in manufacturing industries of wood and of products of wood and cork(except furniture) and of other transport equipment. Sorted by their size of business, the rate was higher as the number of employee was larger in manufacturing sector. Conclusions: Compared to the same rate estimated in the US, 17.2%, the result of this study seems to be in a resonable range.

다양한 급원을 통한 우리나라 사람들의 비타민 및 무기질 노출량 평가 (Exposure Assessment of Vitamins and Minerals from Various Sources of Koreans)

  • 김선효;이선희;황유진;김화영
    • Journal of Nutrition and Health
    • /
    • 제39권6호
    • /
    • pp.539-548
    • /
    • 2006
  • In recent years a concern of excessive intakes of vitamins and minerals from various sources is increasing, since there has been a marked increase in production and consumption of vitamin and mineral supplements and fortified foods. The purpose of this study was to assess the maximum exposure of vitamins and minerals from various sources including diet, fortified foods, and health functional foods among Koreans. As a result, the highest exposure group of most vitamins and minerals from diet was adults (30 - 49 years of age) according to 2001 Korean National Nutrition and Health Survey Report. Maximum dietary intakes of vitamin A, $B_1,\;B_2$, C, nicotinamide, calcium, phosphorus and iron were 0.5 - 7 times of the RDA for Koreans, 7th ed. Maximum intakes of vitamins and minerals from fortified foods by adults (20 - 59 years of age) were 8 - 760% of the Korean RDA. In addition, maximum exposure of vitamins and minerals from vitamin mineral health functional foods by middle aged people was 35 - 140% of the upper limits (UL: DRI for Koreans). As a consequence, maximum combined intakes of vitamin $B_6$, vitamin C, calcium, iron and zinc from the above sources including diet, fortified foods and vitamin mineral health functional foods were greater than the UL. These results would be applied for determining the safe upper limits of vitamin and mineral of health functional foods.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

부비동 디지털 엑스선검사에서 자동노출제어 조절인자의 최적화를 통한 조사선량 감소 효과 (Effects of Exposure Dose Reduction by Optimization of Automatic Exposure Control Factors in Digital Radiographic Examination of Paranasal Sinus)

  • 정민규;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.173-181
    • /
    • 2021
  • The purpose of this study was to reduce dose while maintaining image quality during digital radiographic examination of paranasal sinus by using the automatic exposure control (AEC) system. The tube voltage was set as six stages that increased by about 10 kVp to 70 kVp, 81 kVp, 90 kVp, 102 kVp, 109 kVp and 117 kVp. And then the AEC system conditions were consisted of 9 setting environments, that change mode of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). We measured automatically exposed tube current (mAs) under 54 conditions with combined these, and assessed SNR and PSNR through the acquired images. In addition, four radiologists performed a qualitative assessment of the acquired images for each combination on a five-point scale of the Likert. As a result, the lowest dose and the highest values of SNR and PSNR in images with a qualitative assessment more than 4 point were the AEC control factors of 90 kVp, S800, D2.5. We applied this condition to the clinical trial, it showed an effect of 83.1% reduction in exposure radiation dose (mR). Therefore, AEC system could be used as dose reduction technology if it understood and used related regulatory factors and physical characteristics.

The Unequal Burden of Self-Reported Musculoskeletal Pains Among South Korean and European Employees Based on Age, Gender, and Employment Status

  • Bahk, Jinwook;Khang, Young-Ho;Lim, Sinye
    • Safety and Health at Work
    • /
    • 제12권1호
    • /
    • pp.57-65
    • /
    • 2021
  • Background: The objective of this study was to elucidate the relationships musculoskeletal pains with combined vulnerability in terms of age, gender, and employment status Methods: The fifth European Working Conditions Survey (EWCS) in 2010 (43,816 participants aged 15 years and over) analyzed for European employees and the third Korean Working Conditions Survey (KWCS) in 2011 (50,032 participants aged 15 years and older) analyzed for Korean employees. In this study, three well known vulnerable factors to musculoskeletal pains (older age, female gender, and precarious employment status) were combined and defined as combined vulnerability. Associations of musculoskeletal pains with combined vulnerability were assessed with prevalence ratios (PRs) and 95% confidence intervals (CIs) estimated by Poisson regression models with robust estimates of variance. Results: The prevalences of musculoskeletal pains were lower but the absolute and relative differences between combined vulnerabilities were higher among Korean employees compared with the European employees. Furthermore, the increased risk of having musculoskeletal pains according to combined vulnerability was modestly explained by socioeconomic factors and exposure to ergonomic risk factors, especially in Republic of Korea. Conclusions: The results of this study showed that the labor market may be more unfavorable for female and elderly workers in Republic of Korea. Any prevention strategies to ward off musculoskeletal pains, therefore, should be found and implemented to mitigate or buffer against the most vulnerable work population, older, female, and precarious employment status, in Republic of Korea.

디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구 (Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR))

  • 황준호;최지안;이경배
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.375-383
    • /
    • 2020
  • 본 연구는 자동노출제어장치 사용 시 이온 챔버의 성능과 조합에서 비롯된 문제를 정량적으로 분석하는 방법론을 제시하고 디지털 방사선 시스템의 성능을 최적화하고자 하였다. 실험방법은 복부와 골반부 검사에 사용된 파라미터의 X선질을 백분율 평균오차(PAE; Percentage Average Error)와 반가층(HVL; Half Value Layer)으로 평가하였다. 그 후 세 가지 이온 챔버를 조합했을 때의 입사표면선량(ESD; Entrance Surface Dose)과 엔트로피(Entropy)를 산출하여 방사선 출력의 안정성과 영상 품질을 분석하였다. 그 결과 실험에 사용한 디지털 방사선 시스템의 X선질은 모두 정상 범위의 백분율 평균오차와 반가층을 보였다. 입사표면선량은 챔버의 조합에 비례하여 증가하였고, 엔트로피는 세 개의 챔버가 조합됐을 때를 제외하고는 이온 챔버의 조합에 비례하여 증가하였다. 결론적으로 입사표면선량과 엔트로피를 이용한 분석은 이온 챔버의 성능과 조합의 문제를 평가하는데 유용한 방법인 것을 알 수 있었으며, 두 개 이하의 이온 챔버를 조합했을 때 디지털 방사선 시스템의 성능을 최적으로 유지할 수 있음을 알 수 있었다.

Schedule-Dependent Effects of Kappa-Selenocarrageenan in Combination with Epirubicin on Hepatocellular Carcinoma

  • Ji, Yu-Bin;Ling, Na;Zhou, Xiao-Jun;Mao, Yun-Xiang;Li, Wen-Lan;Chen, Ning
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3651-3657
    • /
    • 2014
  • Hepatocellular carcinoma (HCC) has a relatively higher incidence in many countries of Asia. Globally, HCC has a high fatality rate and short survival. Epirubicin, a doxorubicin analogue, may be administered alone or in combination with other agents to treat primary liver cancer and metastatic diseases. However, the toxic effects of epirubicin to normal tissues and cells have been one of the major obstacles to successful cancer chemotherapy. Here, we investigated the effects of epirubicin in combination with kappa-selenocarrageenan on mice with H22 implanted tumors and HepG-2 cell proliferation, immune organ index, morphology, cell cycle and related protein expressions in vivo and in vitro with sequential drug exposure. The inhibitory rate of tumor growth in vivo was calculated. Drug sensitivity was measured by MTT assay, and the King's principle was used to evaluate the interaction of drug combination. Morphological changes were observed by fluorescent microscopy. Cell cycle changes were analyzed by flow cytometry. Expression of cyclin A, Cdc25A and Cdk2 were detected by Western blotting. In vivo results demonstrated that the inhibitory rate of EPI combined with KSC was higher than that of KSC or EPI alone, and the Q value indicated an additive effect. In addition, KSC could significantly raise the thymus and spleen indices of mice with H22 implanted tumors. In the drug sensitivity assay in vitro, exposure to KSC and EPI simultaneously was more effective than exposure sequentially in HepG-2 cells, while exposure to KSC prior to EPI was more effective than exposure to EPI prior to KSC. Q values showed an additive effect in the simultaneous group and antagonistic effects in the sequential groups. Morphological analysis showed similar results to the drug sensitivity assay. Cell cycle analysis revealed that exposure to KSC or EPI alone arrested the cells in S phase in HepG-2 cells, exposure to KSC and EPI simultaneously caused accumulation in the S phase, an effect caused by either KSC or EPI. Expression of cyclin A, Cdc25A and Cdk2 protein was down-regulated following exposure to KSC and EPI alone or in combination, exposure to KSC and EPI simultaneously resulting in the lowest values. Taken together, our findings suggest that KSC in combination with EPI might have potential as a new therapeutic regimen against HCC.

Posterior Atlantoaxial Screw-Rod Fixation in a Case of Aberrant Vertebral Artery Course Combined with Bilateral High-Riding Vertebral Artery

  • Park, Young-Seop;Kang, Dong-Ho;Park, Kyung-Bum;Hwang, Soo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권4호
    • /
    • pp.367-370
    • /
    • 2010
  • We present a case of posterior atlantoaxial screw-rod fixation in a patient with an aberrant vertebral artery (VA) course combined with bilateral high-riding VA. An aberrant VA which courses below the posterior arch of the atlas (C1) that does not pass through the C1 transverse foramen and without an osseous anomaly is rare. However, it is important to consider an abnormal course of the VA both preoperatively and intraoperatively in order to avoid critical vascular injuries in procedures which require exposure or control of the VA, such as the far-lateral approach and spinal operations.

주거공간을 위한 IT결합 광선반시스템 개발 연구 -조명에너지 저감을 중심으로- (A Study on Light-shelf system based on IT in Housing Space -Focus on Lighting Energy Saving-)

  • 안혜영;이행우;김용성
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.133-140
    • /
    • 2013
  • The purpose of this study was to test the effectiveness of the light-shelf system combined with IT to save lighting energy in resident space. According to the multiple variables that affected intensity of illumination, various experiments were designed and conducted. The main findings of this study were following: (1)the optimal level of light-shelf system was formulated which met the appropriate range of intensity of illumination in living-room; (2)although the mixed light-shelf system indicated a high performance, it could often provide discomforts to residents according to the degree of exposure; (3)artificial lights using light-shelf system combined with IT showed a higher effectiveness than those using fixed light-shelf system displayed. This study provided initial information of light-shelf system formative processes that could contribute to the lighting energy diminution. Future studies should focus more on multiple approaches regarding different types of resident space planning.

Review of Radio Frequency Identification and Wireless Technology for Structural Health Monitoring

  • Dhital, Dipesh;Chia, Chen Ciang;Lee, Jung-Ryul;Park, Chan-Yik
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.244-256
    • /
    • 2010
  • Radio frequency identification(RFID) combined with wireless technology has good potential for structural health monitoring(SHM). We describe several advantages of RFID and wireless technologies for SHM, and review SHM examples with working principles, design and technical details for damage detection, heat exposure monitoring, force/strain sensing, and corrosion detection in concrete, steel, carbon fiber reinforced polymer(CFRP), and other materials. Various sensors combined with wireless communication are also discussed. These methodologies can be readily developed, implemented, and customized. There are some technical difficulties, but solutions are being addressed. Lastly, a surface acoustic wave-based RFID system is presented, and possible future trends of SHM based on RFID and wireless technology are presented.