• 제목/요약/키워드: Column type

검색결과 1,207건 처리시간 0.022초

중심 편석층이 있는 극후판 박스-칼럼의 대입열 코너이음 용접시 그루브 형상의 영향 (Effect of the Groove Shape of Ultra Thick Box-Column with Center Segregation under High Heat Input for Corner Welding)

  • 최원규;이종봉;권영두;구남서
    • 한국해양공학회지
    • /
    • 제16권2호
    • /
    • pp.72-79
    • /
    • 2002
  • In this study, time-dependent distributions of temperature and stresses, in the box-column welded from ultra thick plates with center segregation, has been analyzed by the commercial finite element package SYSWELD+, for several types and angles of groove. The major points of investigation are the optimum type and angle of groove that minimize weld stress specially at the center segregation, as well as temperature distribution, residual stresses and changes in the mechanical properties. The results can be summarized as follows; 1) Generally the thermal cycle at the root of groove exhibits relatively rapid cooling pattern, however, most of the other part weldment have a slow cooling pattern in all groove types. 2) Most of the micro-structures of weldment are composed of ferrite and pearlite, meanwhile we could find martensite and bainite locally a the root of the groove. 3) Optimum groove type for high heat input welding of box-column corner is a double groove type, and the optimum angle for the groove is 30~$45^{\circ}$ that minimize deformation and weld stress at the center segregation.

Modelling and experiment of semi rigid joint between composite beam and square CFDST column

  • Guo, Lei;Wang, Jingfeng;Zhang, Meng
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.803-818
    • /
    • 2020
  • Semi-rigid connections with blind bolts could solve the difficulty that traditional high strength bolts were unavailable to splice a steel/composite beam to a closed section column. However, insufficient investigations have focused on the performance of semi-rigid connection to square concrete filled double-skin steel tubular (CFDST) columns. In this paper, a component model was developed to evaluate the mechanical behavior of semi-rigid composite connections to CFDST columns considering the stiffness and strength of column face in compression and column web in shear which were determined by the load transfer mechanism and superstition method. Then, experimental investigations on blind bolted composite joints to square CFDST columns were conducted to validate the accuracy of the component model. Dominant failure modes of the connections were analyzed and this type of joint behaved semi-rigid manner. More importantly, strain responses of CFDST column web and tubes verified that stiffness and strength of column face in compression and column web in shear significantly affected the connection mechanical behavior owing to the hollow part of the cross-section for CFDST column. The experimental and analytical results showed that the CFDST column to steel-concrete composite beam semi-rigid joints could be employed for the assembled structures in high intensity seismic regions.

아날로그 2차원 셀의 순환형 배열을 이용한 R=l/2. K=7형 고속 비터비 디코더 설계 (Design of R=1/2, K=7 Type High Speed Viterbi Decoder with Circularly Connected 2-D Analog Parallel Processing Cell Array)

  • 손홍락;김형석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권11호
    • /
    • pp.650-656
    • /
    • 2003
  • A high speed Viterbi decoder with a circularly connected 2-dimensional analog processing ceil array Is proposed. The proposed Viterbi .decoder has a 2-dimensional parallel processing structure in which an analog processing cell is placed at each node of a trellis diagram, the output column of the analog processing cells is connected to the decoding column, and thus, the output(last) column becomes a column right before the decoding(first) column. The reference input signal given at a decoding column is propagated to the whole network while Its magnitude is reduced by the amount of a error metric on each branch. The circuit-based decoding is done by adding a trigger signals of same magnitudes to disconnect the path corresponding to logic 0 (or 1) and by observing its effect at an output column (the former column of the decoding column). The proposed Viterbi decoder has advantages in that it is operated with better performance of error correction, has a shorter latency and requires no path memories. The performance of error correction with the proposed Viterbi decoder is tested via the software simulation.

Investigation of short column effect of RC buildings: failure and prevention

  • Cagatay, Ismail H.;Beklen, Caner;Mosalam, Khalid M.
    • Computers and Concrete
    • /
    • 제7권6호
    • /
    • pp.523-532
    • /
    • 2010
  • If an infill wall in a reinforced concrete frame is shorter than the column height and there is no initial gap between the column and the infill wall, the short column effect can occur during an earthquake shaking. This form of damage is frequently observed in many earthquake-damaged buildings all around the world and especially in Turkey. In this study, an effective method, which consists of placing additional infill wall segments surrounding the short column, to prevent this type of failure is examined. The influence of adding infill wall in the reduction of the shear force in the short column is also investigated. A parametric study is carried out for one-storey infilled frames with one to five bays using the percentage of the additional infill wall surrounding the short column and the number of spans as the parameters. Then the investigation is extended to a case of a multistorey building damaged due to short column effect during the 1998 Adana-Ceyhan earthquake in Turkey. The results show that the addition of the infill walls around the potential short columns is an effective way to significantly reduce the shear force.

철근을 이용한 충전 강관기둥 접합부의 인장거동 (Tensile Behavior of Concrete-Filled Column Connections Using Re-bars)

  • 이영렬;유영찬;신경재;오영석;이승준;문태섭
    • 한국강구조학회 논문집
    • /
    • 제8권3호통권28호
    • /
    • pp.89-96
    • /
    • 1996
  • The objective of this study is to investigate the structural behavior of Concrete-Filled Steel Tubular Column connections using reinforced bar. The parameter of specimens is the area of each reinforced bar (SD40 : D13, D16, D19, D22, D25). The simple tensile experiment is conducted to 5 kinds of specimens. Estimating the load, displacement, and strain from each kind, we compared them to basic elementary type (Flange Type, Basic Type, DPA Type, DPB Type). In each specimen, We can get the yielding load obtained by the theoretical three failure modes which make it possible to predict the experimental results. Actually, through the comparison and analysis, we come to know that the experimental results and theoretical results are nealy the same. Further, we will exert to apply the connections using reinforced bar to construction of high-rise building.

  • PDF

볼트 접합 및 프리스트레스를 적용한 프리캐스트 콘크리트 보-기둥 외부접합부의 내진실험 (Seismic Experiment of Precast Concrete Exterior Beam-Column Joint Using Bolt Type Connection and Prestressing Method)

  • 이동주;이주동;오태수;강현구
    • 콘크리트학회논문집
    • /
    • 제26권2호
    • /
    • pp.125-133
    • /
    • 2014
  • 이 연구에서는 볼트접합 및 프리스트레스를 적용한 프리캐스트 콘크리트 보-기둥 외부접합부의 내진 및 구조적 성능을 평가하였다. 총 5개의 보-기둥 외부접합부 실험체를 제작하고 보 단부에 변위제어 방식으로 반복하중을 가하며 실험을 수행하였다. 이 연구의 결과를 근거로 다음과 같은 결론을 얻을 수 있었다. 완전 건식공법이 적용된 PC 접합부는 완전 습식공법이 적용된 RC 접합부보다 에너지소산이나 핀칭현상에 있어서 불리한 거동을 보였지만 이는 설계과정에서 의도된 현상이며, 횡변형 능력에 있어서는 우수한 결과를 보였다. 또한 층간변위비 4%까지 횡하중 저항성능의 손실이 발생하지 않았고 매설용너트에 항복이 집중되는 메커니즘을 보이는 점으로 미루어 볼 때 개발된 접합부는 외부접합부 횡저항시스템으로서 적합한 것으로 사료된다. 추가적인 프리스트레스는 PC 접합부의 과도한 핀칭현상 방지 및 접합부 균열제어에 효과적이었으며 PC 접합부의 전체적인 내진성능을 향상시켰다.

무량판 구조시스템 접합부의 기둥 형상비에 따른 내진 성능 평가 (Seismic Performane Evaluation of Flat Plate System Considering Column Aspect Ratio)

  • 이현호;천영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.74-80
    • /
    • 2008
  • 본 논문은 기둥형상비를 실험 변수로 가지는 무량판 슬래브-기둥 접합부의 내진성능을 평가하는데 있다. 본 연구에서는 무량판 슬래브의 뚫림 전단파괴를 방지하기 위하여 본 연구와 병행하여 진행된 연구에서 개발된 연속 절곡된 전단보강근을 적용하였다. 기둥형상비에 따른 실험체는 각각 FIS1-05(0.5), FIS1- 10(1.0), FIS1-20(2.0) 이다. 실험체의 수평방향으로 정적 수평하중을 가력 하였으며, 중력하중비에 의한 일정 수직 하중을 적용하였다. 실험결과는 슬래브-기둥 접합부의 수평 변위 및 강도를 기준으로 평가하였다. 분석결과, FIS1-05, FIS1-20와 같은 장방형 기둥을 갖는 접합부의 성능이 FIS1-10와 같은 정방형 기둥을 갖는 접합부보다 우수한 것으로 평가되었다.

DCM으로 개량된 연약점토지반의 지반융기에 관한 고찰 (A Study on Ground Heave Characteristics of Soft Ground with DCM)

  • 유승경;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제19권4호
    • /
    • pp.75-84
    • /
    • 2020
  • 본 연구에서는 DCM으로 개량된 연약점토지반에 관한 실내모형실험 결과를 바탕으로, DCM 개량 형식에 따른 연약점토지반의 융기량을 분석하였다. 즉, 무보강 및 3종류의 DCM 개량 형식에 대한 하중 재하에 따른 연약지반의 융기 특성을 평가하였다. DCM이 적용되지 않은 경우에는 4단계 하중조건에서부터 연약점토지반의 측방변형이 크게 증가하면서 미성토구간의 융기가 급격하게 발생하였다. 그리고 최종 하중단계에서의 융기량은 지표면의 인장파괴가 발생되었다. DCM 개량 형식에 따른 지반의 최대 융기량은 최종 하중단계에서 발생하였으며, 융기량의 크기는 말뚝식, 벽식 및 격자식 순으로 감소하였다. 특히, 격자식 개량체가 적용된 경우에는 최종 하중단계에서 재하부 지반의 극단적 파괴에도 불구하고, 지반 융기에 대한 억지효과가 매우 크게 나타났다. 또한 계측위치별 최대 융기량을 분석한 결과, LVDT-1의 위치에서 격자식은 말뚝식과 벽식에 비하여 각각 3.1% 및 1.6% 수준의 융기량을 보였고, LVDT-2의 위치에서는 각각 1.0% 및 2.1%의 융기가 발생하였다.

원형단면 멀티기둥 풍력타워 적용 T형 강관조인트 강도 평가 (Strength Evaluation of T-type Tubular Joints for Circular Section Multi-Column Wind Towers)

  • 김경식;박현용;서동혁
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.119-129
    • /
    • 2015
  • 강재량을 줄이면서도 풍하중의 영향을 완화시킬 수 있는 장점으로, 수평재로 서로 연결된 다수의 수직 원형강관으로 구성된 멀티기둥 풍력타워 시스템은 기존의 단일 실린더형 타워구조에 대한 대안으로 고려될 수 있다. 멀티기둥 타워를 하나의 타워구조로 거동하게 하기 위해서는 수직 강관과 수평 강관의 연결부인 강관조인트의 강도 확보가 중요하다. 본 연구에서는 멀티기둥에 적용될 수 있는 T 조인트의 강도평가를 수행하였다. AISC, Eurocode3, ISO 19902, CIDECT의 4가지 강관조인트 설계기준을 검토하고, 조인트에서 주강관과 지강관의 세장비에 대한 매개변수해석을 통하여 설계기준에서 제공되는 강도산정식의 타당성을 검토하였다.

수평스티프너를 이용한 철골 기둥-보 약축접합부 상세 개발에 관한 연구 (Development of Beam-to-Column Connection Details with Horizontal Stiffeners in Weak Axis of H-shape Column)

  • 이도형;함정태;김성배;김영호;김상섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.641-652
    • /
    • 2004
  • 철골 기둥-보 강축 접합부에 대한 연구는 그 동안 국내외에서 오랜 기간 연구가 진행되어 내진성능 및 접합부의 강도를 개선시킬 수 있는 많은 접합 형식이 개발되어 사용 중에 있으나, 약축 접합 형식에 대한 연구는 거의 없는 실정이다. 또한 현재 국내에서는 시공성을 고려하여 기존의 브라켓형식 용접 접합부를 선호하고 있으나, 용접량이 많아 취성적인 거동이 우려되며 과대 설계된 경향이 있다. 본 연구의 실험 결과에서 기존 브라켓 형식 용접접합은 용접량이 과도한 것으로 나타났으며, 기둥 웨브와 보의 웨브의 용접은 불필요한 것으로 판단된다. 그리고 본 연구에서 제안한 새로운 기둥-보 약축 접합형식들에 대한 실험 결과에서 기존 브라켓형식 용접접합보다 우수한 내력 및 연성을 보유하여 구조적으로 안전함을 확인할 수 있었다.