Abstract
This paper evaluates seismic capacities of slab-column joints in flat plate system which has columns with various aspect ratio as experimental parameters. Continuous - bended shear reinforcements were applied for the prevention of punching shear failure in this study. The specimens of FIS1-05, FIS1-10, and FIS1-20 have the aspect ratio of 0.5, 1.0, and 2.0 respectively. Static lateral force was applied to the specimens in a horizontal direction and vertical load was applied by constant gravity load ratio. The test results were evaluated by lateral displacement and strength of slab-column joint. Consequently, the lateral resisting capacity of rectangular type column such as FIS1-05, FIS1-20 is superior to the square type column such as FIS1-10.
본 논문은 기둥형상비를 실험 변수로 가지는 무량판 슬래브-기둥 접합부의 내진성능을 평가하는데 있다. 본 연구에서는 무량판 슬래브의 뚫림 전단파괴를 방지하기 위하여 본 연구와 병행하여 진행된 연구에서 개발된 연속 절곡된 전단보강근을 적용하였다. 기둥형상비에 따른 실험체는 각각 FIS1-05(0.5), FIS1- 10(1.0), FIS1-20(2.0) 이다. 실험체의 수평방향으로 정적 수평하중을 가력 하였으며, 중력하중비에 의한 일정 수직 하중을 적용하였다. 실험결과는 슬래브-기둥 접합부의 수평 변위 및 강도를 기준으로 평가하였다. 분석결과, FIS1-05, FIS1-20와 같은 장방형 기둥을 갖는 접합부의 성능이 FIS1-10와 같은 정방형 기둥을 갖는 접합부보다 우수한 것으로 평가되었다.