Exposed Reinforced Concrete-Filled Steel Tubular (RCFST) column-base joint with high-strength

  • Mou, Ben;Wang, Zian;Qiao, Qiyun;Zhou, Wanqiu
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • The weld quality has always been an important factor affecting the development of exposed CFT column-base joint. In this paper, a new type of exposed RCFST column-base joint is proposed, in which the high strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens, the varying axial force ratio (0, 0.25 and 0.5), were tested under cyclic loadings. In addition, the bending moment capacity, energy dissipation capacity and deformation capacity of column-base joints were clarified. The experimental results indicated that the axial force ratio increases the stiffness and the bending moment and improves the energy dissipation capacity of column-base joints. This is because a large axial force can limit the slip between steel tubular and infilled concrete effectively. The specimens show stable hysteresis behavior.

Water pressure Test and analysis for Welding Thickness Decision of New Cold-formed Type Concrete Filled Tubular Square Column (조립각형 CFT 기둥의 용접크기 결정을 위한 수압실험 및 해석)

  • Lee, Seong-Hui;Kim, Sun Hee;Kim, Young Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.515-526
    • /
    • 2009
  • There are three main production processes in the manufacture of concrete-filled square steel columns. The first process is known as the 'box-type process' or 'four-seam method,' wherein four beams are welded together at the seams. The second is the 'cold-forming process' or 'two-seam method,' wherein the seams of two channel beams are welded together. The third is the 'pressing process' or 'one-seam method,' wherein a circular column is pressed until it becomes a square column. In calculating the production cost for the making of a steel tube, it is very important to consider the welding process to be used and the desiredthickness of the steel tube, such as a square column that was developed under a new method, formed through the four-seam flare welding method at the center of the steel column width, following the L-shape formation. Certain tests were suggested in this study to evaluate the welding amount of concrete-filled square steel columns. With the parameters of the production method of a square steel column, the thickness of the steel square columns, and the welding amount, six specimens were produced. A structural test and finite-element analysis were conducted to assess the behavior of the steel column according to the water pressure inside the steel columns.

A study on pushover analyses of reinforced concrete columns

  • Sung, Yu-Chi;Liu, Kuang-Yen;Su, Chin-Kuo;Tsai, I-Chau;Chang, Kuo-Chun
    • Structural Engineering and Mechanics
    • /
    • v.21 no.1
    • /
    • pp.35-52
    • /
    • 2005
  • This paper proposes a realistic approach to pushover analyses of reinforced concrete (RC) structures with single column type and frame type. The characteristic of plastic hinge of a single RC column subjected to fixed axial load was determined first according to column's three distinct failure modes which were often observed in the experiments or earthquakes. By using the determined characteristic of plastic hinge, the pushover analyses of single RC columns were performed and the analytical results were investigated to be significantly consistent with those of cyclic loading tests. Furthermore, a simplified methodology considering the effect of the variation of axial force for each RC column of the frame structure during pushover process is proposed for the first time. It would be helpful in performing pushover analysis for the structures examined in this study with efficiency as well as accuracy.

Stability and minimum bracing for stepped columns with semirigid connections: Classical elastic approach

  • Aristizabal-Ochoa, J. Dario
    • Structural Engineering and Mechanics
    • /
    • v.5 no.4
    • /
    • pp.415-431
    • /
    • 1997
  • Stability equations that evaluate the elastic critical axial load of stepped columns under extreme and intermediate concentrated axial loads in any type of construction with sidesway totally inhibited, partially inhibited and uninhibited are derived in a classical manner. These equations can be utilized in the stability analysis of framed structures (totally braced, partially braced, and unbraced) with stepped columns with rigid, semirigid, and simple connetions. The proposed column classification and the corresponding stability equations overcome the limitations of current methods which are based on a classification of braced and unbraced columns. The proposed stability equations include the effects of: 1) semirigid connections; 2) step variation in the column cross section at the point of application of the intermediate axial load; and 3) lateral and rotational restraints at the intermediate connection and at the column ends. The proposed method consists in determining the eigenvalue of a $2{\times}2$ matrix for a braced column at the two ends and of a $3{\times}3$ matrix for a partially braced or unbraced column. The stability analysis can be carried out directly with the help of a pocket calculator. The proposed method is general and can be extended to multi-stepped columns. Various examples are include to demonstrate the effectiveness of the proposed method and to verify that the calculated results are exact. Definite minimum bracing criteria for single stepped columns is also presented.

Global seismic performance of a new precast CFST column to RC beam braced frame: Shake table test and numerical study

  • Xu, S.Y.;Li, Z.L.;Liu, H.J.
    • Steel and Composite Structures
    • /
    • v.21 no.4
    • /
    • pp.805-827
    • /
    • 2016
  • A new type of precast CFST column to RC beam braced frame is proposed in this paper. A series of shake table tests were conducted to excite a one-third scale six-story model for investigating the global seismic performance of this type of structure against earthquake actions. Particular emphasis was given to its dynamic property, global seismic responses and failure path. Correspondingly, a numerical model built on the basis of fiber-beam-element model, multi-layer shell model and element-deactivation method was developed to simulate the seismic performance of the prototype structure. Numerical results were compared with the measured values from shake table tests to verify the validity and reliability of the numerical model. The results demonstrated that the proposed novel precast CFST column to RC beam braced frame performs excellently under strong earthquake excitations; the "strong CFST column-weak RC beam" and "strong connection-weak member" anti-seismic design principles can be easily achieved; the maximum deflections of precast CFSTC-RCB braced frame satisfied the deflection limitations proposed in national code; the numerical model can properly simulate the dynamic property and responses of the precast CFSTC-RCB braced frame that are highly concerned in engineering practice.

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.10 no.3
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

Suggestion on Strength Formula of Square Hollow Section Tubluar Column-to-BeamPinned Connections (각형강관 기둥-보 핀접합부의 내력식 제안)

  • Choi, Sung Mo;Lee, Seong Hui;Lee, Kwang Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.525-534
    • /
    • 2006
  • Column-to-beam pinned connections can cause local moment to the web of a steel tube due to the distance of eccentricity between the row of bolts and the column flange, which possibility deteriorates the load capacity of column. In this study, a square hollow section tubular used finite element analysis of a square hollow section tubular column was carried out, and the column width and thickness, existence and non-existence of internal reinforcement, and existence and non-existence of compressive force were taken as variables to examine the load capacity deterioration of a square column caused by moment. To guarantee the reliability of the finite element results, some specimens were fabricated and tested. The yield line method was applied to suggest the strength formulas of the square tubular column to the beam pinned connections. Based on the study results, the column strength the moment of the square hollow section tubular column to the beam pined connections improved with the increase in the w to strength limitations, a no-reinforcement type of square hollow section tubular column was proposed, and if the limitation values were not satisfied, the reinforcement of the internal column was made mandatory. Therefore, the horizontal -reinforcement type considered the strength increase, and the fabrication of the square hollow section tubular column was ar column that considered its load capacity with the moment for the no-reinforcement and the horizontal-reinforcement types.

Finite Element Analysis on the Displacement Behavior Safety of Hollow Shafts with Equivalent Volume (동등체적을 갖는 중공축의 변위거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.73-77
    • /
    • 2016
  • This paper presents the displacement behavior safety of hollow shafts with an equivalent volume for various cross sectional area using a finite element method. The FEM results indicate that the hollow shafts with X-type or Y-type columns between outer tube, middle tube and inner tube may reduce a maximum displacement at the middle length of hollow shafts. Especially, the load-bearing column of X-type or Y-type hollow shaft is directly connected between outer tube and inner tube without a shift for reducing the vertical displacement. And increased thickness of a load-bearing column is recommended for reducing the vertical displacement and increasing the displacement behavior safety for an equivalent volume of a hollow shaft.

A Study on the Heating Performance of SCW Type Geothermal Heat Pump System for Residential House (지하수 이용 지열 히트펌프 시스템의 주거용 건물 적용시 난방성능 특성에 관한 연구)

  • Kim, Ju-Hwa;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-Hwan
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.11-18
    • /
    • 2008
  • Geothermal heat pump system using sanding column well type with their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So in the residential house this study estimated heating coefficient of performance (COP) of geothermal heat pump system using sanding column well type which is excellent in heat recovery. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the COP is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

Design and Analysis of Column Type Sensing Element for Large Compact Load Cell (대용량 Compact형 로드셀의 기둥형 감지부 설계 및 해석)

  • Kang, Dae-Im;Shin, Hong-Ho;Kim, Jong-Ho;Park, Yon-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.601-607
    • /
    • 2003
  • The column type is used as the sensing element of the load cell to measure the large force in the range of 10$^4$~ 10$^{7}$ N. However. it is not easy to handle the load with large capacity due to its size. It is, therefore, necessary to design a compact load cell with a low aspect ratio. Thus this paper showed the characteristic evaluation of compact load cell with respect to the shape of supporting plate. The supporting plate of the load cell was an annular type with inner(D$_{i}$) and outer(D$_{o}$) diameters. Using the strain distribution obtained from FEM. the supporting plate was designed to get the stable output voltage of the load cell. The three designed supporting plates were manufactured, and the result of characteristic experiment of the load cell, using the 10 MN hydraulic force standard machine, was compared with FEM.M.M.