• Title/Summary/Keyword: Column Experiment

Search Result 720, Processing Time 0.025 seconds

Electrokinetic Remediation of Cobalt Contaminated Soil (코발트 오염토양 동전기적 제염)

  • 김계남;오원진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.290-293
    • /
    • 2000
  • After kaolin clay was compulsorily contaminated with Co$^{2+}$ion, the remediation characteristics by electrokinetic method were analyzed. Ethanoic buffer was injected in the soil column and $CH_3$COOH was continuously inputted in cathode reservoir to restrain the pH elevation. Since pH of the cathode side of the soil column was 4.0 at initial and was restrained by 6.5 at 43.6 hours, Precipitation, Co(OH)$_2$, was not formed in the column. Effluent rate increased with time passage and remediation in the column in initial time was mainly controlled by ion migration. 13.1% of total in the soil column was remediated in 10 hours, and the 6.8% of total in 20.8 hours, and the 71.7% of total in 43.6 hours, and the 94.6% of total in 43.6 hours. Meanwhile, the residual concentrations in the column calculated by the developed model were similar to those by experiment.t.

  • PDF

Effect of Buffer Composition, Sephadex Grade and Column Size on Filtration Based Quality Improvement of Semen from Murrah Buffalo Bull

  • Maurya, V.P.;Tuli, R.K.;Goyal, R.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.2
    • /
    • pp.165-171
    • /
    • 2003
  • Sixty semen ejaculates collected at weekly interval from four Murrah Buffalo bulls over a period of seven months (Nov.1999 to May 2000) were used in the present study. Three buffer medium (sodium citrate, TES and Tris) were used for soaking of sephadex. Three grades of sephadex (G-15,G-100, and G-200) were used for preparation of columns. Columns of three different height (one, two and three cm) were used for separation of semen. Twenty semen ejaculates were used in each project. In the first experiment each semen ejaculates was divided into four parts. One part was kept as control and other three parts were passed thought one cm column of sephadex G-15 prepared in three different buffers. There was significant (p<0.05) increase in percent progressive sperm motility and percent live spermatozoa and decrease in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome as well as sperm numbers after filtration through all the three columns. Sperm quality obtained in the filtrate of column prepared in Tris buffer was better in comparison to other two buffers. So the Tris buffer was used in the second trial. Twenty semen ejaculates were used in this experiment. Each semen ejaculate was divided into four parts. One part was kept as control (non-filtered) and other three parts were passed through columns of different grade of sephadex (G-15, G-100 and G-200). Progressive sperm motility and live sperm percentage improved significantly while decline in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome and sperm concentration was observed after filtration through all the columns as compared to control (non-filtered) semen. Since post filtration quality of semen was better in the sephadex G-100 column, therefore it was selected for the next experiment. In third experiment, Tris buffer and sephadex G-100 were used for preparing columns of different height (one, two and three cm) and twenty semen ejaculates were filtered. The quality characteristics of semen (percent progressive sperm motility, percent live spermatozoa and sperm concentration) after filtration through one cm column were significantly (p<0.05) higher than after filtration through columns of two and three cm height. However non -significant (p>0.05) difference due to height of columns was observed for percent abnormal and percent damaged acrosome but 1 cm column comparatively gave better result than of 2 and 3 cm column height.

Experimental research on load-bearing capacity of cast steel joints for beam-to-column

  • Han, Qinghua;Liu, Mingjie;Lu, Yan
    • Structural Engineering and Mechanics
    • /
    • v.56 no.1
    • /
    • pp.67-83
    • /
    • 2015
  • The load transfer mechanism and load-bearing capacity of cast steel joints for H-shaped beam to square tube column connection are studied based on the deformation compatibility theory. Then the monotonic tensile experiments are conducted for 12 specimens about the cast steel joints for H-shaped beam to square tube column connection. The findings are that the tensile bearing capacity of the cast steel joints for beam-column connection depends on the ring of cast steel stiffener. The tensile fracture happens at the ring of the cast steel stiffener when the joint fails. The thickness of square tube column has little influence on the bearing capacity of the joint. The square tube column buckles while the joint without concrete filled, but the strength failure happens for the joint with concrete filled column. And the length of welding connection between square tube column and cast steel stiffener has little influence on the load-bearing capacity of the cast steel joint. Finally it is shown that the load-bearing capacity of the joints for H-shaped beam to concrete filled square tube column connection is larger than that of the joints for H-shaped beam to square tube column connection by 10% to 15%.

Design of Inchworm Linear Motor Using Design of Experiment (실험계획법을 이용한 인치웜 리니어 모터의 설계)

  • 예상돈;민병현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1041-1044
    • /
    • 2002
  • Inchworm linear motor is one of the ultra precision position apparatuses and has many kinds of forms and structures according to the conditions of working space and range. In this paper, the Inchworm linear motor consists of three PZTs(Piezo-electric transducer), three columns ma two plates. finite element method was used to determine the type or hinges installed in column of inchworm linear motor DOE(Design of experiment) was used to determine the optimal design condition of a column by comparing the von-mises stresses according to the change of thickness of hinge, round of hinge, height of arm, angle of v-notch, round of v-notch and thickness of column. From the result, round of hinge, height of arm and thickness of hinge were determined a effective design parameters.

  • PDF

Humic Acid Removal from Water by Iron-coated Sand: A Column Experiment

  • Kim, Hyon-Chong;Park, Seong-Jik;Lee, Chang-Gu;Han, Yong-Un;Park, Jeong-Ann;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • Column experiments were performed in this study to investigate humic acid adhesion to iron oxide-coated sand (ICS) under different experimental conditions including influent humic acid concentration, flow rate, solution pH, and ionic strength/composition. Breakthrough curves of humic acid were obtained by monitoring effluents, and then column capacity for humic acid adsorption ($C_cap$), total adsorption percent (R), and mass of humic acid adsorbed per unit mass of filter media ($q_a$) were quantified from these curves. Results showed that humic acid adhesion was about seven times higher in ICS than in quartz sand at given experimental conditions. This indicates that humic acid removal can be enhanced through the surface charge modification of quartz sand with iron oxide coating. The adhesion of humic acid in ICS was influenced by influent humic acid concentration. $C_cap$ and $q_a$ increased while R decreased with increasing influent humic acid concentration in ICS column. However, the influence of flow rate was not eminent in our experimental conditions. The humic acid adhesion was enhanced with increasing salt concentration of solution. $C_cap$, $q_a$ and R increased in ICS column with increasing salt concentration. On the adhesion of humic acid, the impact of CaCl2 was greater than that of NaCl. Also, the humic acid adhesion to ICS decreased with increasing solution pH. $C_cap$, $q_a$ and R decreased with increasing solution pH. This study demonstrates that humic acid concentration, salt concentration/composition, and solution pH should be controlled carefully in order to improve the ICS column performance for humic acid removal from water.

Strength and Moment-Curvature Relationship of HCFT Columns under Eccentric Load (편심압축이 작용하는 HCFT기둥에 대한 내력특성과 모멘트-곡률의 곤계)

  • 이승조;박정민;김화중
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.864-873
    • /
    • 2002
  • Recently, CFT Column has reported a lot of study result, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing column. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, high-strength concrete filled steel square tube column(HCFT) examined numerical value explanatorily about transformation performance(M-ø) of when short-column receives equal flexure-moment from axial stress on research for concrete. hnd, with basis assumption, executed development of analysis program of moment-curvature relation for analytic analysis of transformation performance of HCFT section that get by an experiment. This study investigated to properties of structural(capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete(600kgf/$\textrm{cm}^2$), D/t ratio, slenderness ratio(λ) and concrete kinds under eccentric load. And, I executed comparative analysis with AISC-LRFD, AIJ and Takanori Sato etc. and experiment result that is capacity design formula.

Experiment Study on the Flexural-Axial Capacity of Steel-Concrete Composite Column composed of Non-Compact Section (비조밀단면을 가진 SC 합성 기둥의 휨-압축 내력에 관한 실험 연구)

  • Oh, Myoung Ho;Kim, Bum Rae;Kim, Myeong Han;Kim, Dae Joong;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.431-438
    • /
    • 2005
  • A steel-concrete composite column is a recently developed composite system in which the two opposite flanges of the H-shape section are connected by welded links, and the vacant space enclosed by the flanges, web, and links is filled with concrete. Previous experiments on the SC composite column were performed to evaluate its compression and bending and shear strengths, respectively, and they showed fairly good results. In addition to thesestudies, it may be necessary to evaluate the flexural-axial capacity of an SC composite column, because itscolumn members are generally subjected to axial force and bending moment at the same time. In this study, the bending strength of an SC composite column subjected to axial compression force was investigated experimentally. The results of the study showed that the AISC-LRFD provisions representedexcessively low values compared with those of the ACI, Eurocode-4, and Japan Code provisions. The Eurocode-4 provisions represented reasonable evaluations of the strength of the SC composite column composed of a non-compact section.

Retrofitting Device to Increase Seismic Resistant Capactiy of Shear Walls (전단벽의 내진보강을 위한 방법에 관한 연구)

  • Hong, Sung-Gul;Lee, Ji-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.25-28
    • /
    • 2005
  • The elastic buckling load or strength of a concentrically loaded slender metal column may be increased many times by reinforcing it with an assemblage of pretensioned stays and rigidity connected crossarm members. The complete system is herein referred to as a 'stayed column'. The purpose of the pretensioned stays and crossarm members is to introduce, at several points along the length of the column, restraint against translation and rotation and thereby decrease the effective unsupported buckling length of the column. This paper verifies that pretensioned cable of stayed column is effective for cyclic load and increases strength of shear wall against earthquake by reinforcing side of wall. Design process of stayed column which satisfies demanded capacity and ductility of wall is presented by analyzing result of experiment.

  • PDF

Analytical assessment of RC beam-column connections strengthened with CFRP sheets

  • Le, Trung-Kien;Kim, Min;Lee, Ki-Hak;Lee, Jae-Hong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.470-473
    • /
    • 2006
  • Past experiences from recent earthquakes indicate that shear failures of beam-column connections were one of the main reasons causing significant damages and collapses of RC structures subjected to earthquake loadings. Many researchers and engineers have conducted to propose an effective way to improve the joint shear strength of RC connections. This paper presents an analytical model for the RC exterior beam-column joints strengthened with CFRP sheets. In the analytical model, the effect of shear behavior of the RC beam-column joint, bond slip of the beam longitudinal reinforcements and CFRP sheets were considered and incorporated into the non-linear structural analysis program. Final analytical results were compared with those from the experiment of eight exterior RC beam-column specimens. The analytical results showed that the developed connection model is very useful to investigate the hysteretic joint behavior and overall load-displacement response of the RC beam-column connections strengthened with CFRP sheets.

  • PDF

Hysteretic Behavior of Reinforced Concrete Columns Confined By Square Steel Tubes. (정방향 STRC 기둥의 자기이력현상 거동)

  • Wang, Xiaoyong;Zhang, Sumei;Lee, Han-Seaung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.430-433
    • /
    • 2006
  • The reinforced concrete column confined by square steel tubes(RCST) is a reinforced column (RC) confined by thin steel tubes which cover over the full length of the column but terminates 15mm from the column's ends. The steel tube is in uniaxial tension stress state and won't buckle when the column sustains axial load. This will highly increase the bearing capacity and ductility of the columns. The hysteretic behavior of four square RCST columns and one square RC column were experimentally studied under constant axial load and lateral cyclic load. The wide-to-thickness (D/t) ratio of RCST columns employed in this research is 75. The main variables of the experiment were axial load ratio and compressive strength of the concrete. Based on the findings in this research, RCST columns exhibits high lateral strength, ductility, and energy dissipation ability.

  • PDF