• Title/Summary/Keyword: Color stability

Search Result 1,062, Processing Time 0.025 seconds

Characterization of Natural Gardenia Color with Systhetic Color (천연치자색소의 합성색소와의 특성 비교)

  • 김희구;김옥도;이상준
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.5
    • /
    • pp.506-512
    • /
    • 1998
  • In order to replance systhetic colors by natural colors as food additive, properties of Gardenia yellow color and Gardenia blue color were compared with Food yellow No. 4 and Food blue No. 1. Color differeance between Food yellow No. 4 and Gardenia yellow color was 7.55. Thermal stability of Food yellow No. 4 was above 99%. On the other hand, in case of Gardenia yellow color, showed adove 90% of residual color units in 8$0^{\circ}C$$\times$30min and 10$0^{\circ}C$$\times$30min at pH 7.0 but 75% in 121$^{\circ}C$$\times$15min. Difference of light stability between Food yellow No. 4 and gardenia yellow color was about 18%. Addition of ascorbic acid was increased about 6% in light stability. Color difference between Food blue No. 2 and Gardenia blue color was 107. Thermal stability of Food blue No. 2 was above 99%. But Gardenia blue color showed 92% of residual color units in 8$0^{\circ}C$$\times$30min and 10$0^{\circ}C$$\times$30min at pH 7.0 but 90% in 121$^{\circ}C$$\times$15min. Difference of light stability between Food blue No. 4 and Gardenia blue color was about 8%. Addition of -tocopherol was increased about 4% in light stability of Gardenia blue color.

  • PDF

Evaluation of Color Stability according to Shade of Temporary Crown Resin Using Digital Spectrophotometer: In Vitro Study

  • Ku, Hye-min;Jun, Mi-Kyoung
    • Journal of dental hygiene science
    • /
    • v.22 no.3
    • /
    • pp.139-147
    • /
    • 2022
  • Background: Temporary crown resins are used prior to prosthesis placement, indicating the importance of aesthetics. The aim of this study was evaluate the color stability of various staining solutions according to the color of temporary crown resins using VITA Easyshade V. Methods: The temporary crowns used were the powder-liquid type and included four shades. A total of 36 specimens were fabricated in the form of disks with a diameter of 1.8 mm and a depth of 2 mm. They were divided into four groups of nine each, and staining was performed for seven days by precipitation in 3 mL of three staining solutions composed of distilled water, black coffee, and red wine. Color and color stability evaluations were performed by a trained examiner using a digital spectrophotometer (VITA Easyshade V). Color stability was analyzed using the ΔE value. Results: Because of the color stability evaluation using the ΔE value, the difference between three and seven days was significant in the specimen I and III groups (p<0.05). Further, post hoc analysis showed that the ΔE value of red wine was significant, indicating that the color stability in red wine was low. The ΔE values in group II between days three and seven were statistically significant (p<0.05). Post hoc analysis showed that distilled water, coffee, and wine had the highest ΔE values on day three. On day seven, the ΔE value for wine was significant, and the color stability was low. There was no significant difference in group IV according to the staining period and staining solution; therefore, color stability was high (p>0.05). Conclusion: This study showed that most temporary resin restorations exhibited color stability in the staining solution. The darker the color of the temporary resin restoration, the higher the color stability against extrinsic staining.

Effects of Residual Phosphorus Content on color Reversion and Storage Stability of Corn Germ Oil (잔류 인함량이 옥배유의 변색및 저장안정성에 미치는 영향)

  • 김종승;이근보;이미숙
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.2
    • /
    • pp.107-110
    • /
    • 1997
  • To examine the effects of residual phosphorus content on color reversion and storage stability of corn germ oil, the changes of Lovibond total color and stability of oxidation were determined according to the different storage periods at room and incubating temperature, respectively. The residual phosphorus content and storage temperature had the synergistic effect on color reversion during short time storage. The extent of color change was the greatest when oils were stored for 1.0∼1.5 years at room temperature and thereafter gradually tended to reverse color reversion. It is supposed that the double bonds of carotenoids in oils were oxidized and then turned to the volatiles such as epoxide, ionone, and etc. In contrast, the residual phosphorus content increased oxidation stability of oils. The residual phosphorus content was closely correlated with the color reversion and storage stability, respectively.

  • PDF

A Study on the Color Stability of Temporary Resins according to Polymerizing Methods and Staining (온성 방법에 따른 수종의 임시 수복용 레진의 착색시의 색 안정성에 관한 연구)

  • Park, Sung-Ho;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • Dental temporary resin should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental temporary resin has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 resins($Snap^{(R)}$, Temporary bridge $resin^{(R)}$, Trim $II^{(R)}$) according to polymerizing methods and stainning. The resins were divided into groups by 2 types of polymerizing methods ( air or pressure and heat curing) The resins were dyed with coffee, chlorhexidine and artificial saliva and then the color stability was evaluated with a spectrophotometer(CM-503i, Minolta, Japan). The results were as follows ; 1. In the color stability according to polymerizing method, pressure and heat polymerizing method was higher than air polymerizing method. 2. The color stability according to staining fluid decreased in the order of I, II, III group, there was significant difference among the groups of staining fluid. 3. The color stability according to resins decreased in the order of $Snap^{(R)}$, Trim $II^{(R)}$, Temporary Bridge $resin^{(R)}$, The $Snap^{(R)}$ resin was highest color stability, there was significant difference among the 3 resins.

  • PDF

Investigation of muscle-specific beef color stability at different ultimate pHs

  • Wu, Shuang;Han, Jina;Liang, Rongrong;Dong, Pengcheng;Zhu, Lixian;Hopkins, David L.;Zhang, Yimin;Luo, Xin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.12
    • /
    • pp.1999-2007
    • /
    • 2020
  • Objective: This study was aimed to investigate the muscle-specific beef color stability at normal and high ultimate pHs. Methods: The impact of muscle (Longissimus lumborum [LL] vs psoas major [PM]) and pH (normal ultimate pH [Np] vs high pH dark cutting beef [Hp]) on color stability, indicated by basic color traits, metmyoglobin reducing activity (MRA) and oxygen consumption (OC), as well as the lipid oxidation, were determined over 7 days of display at 4℃. Results: Hp-LL had the highest pH (6.92), followed by Hp-PM (6.01), Np-PM (5.76), and Np-LL (5.52). Hp-LL had increased (p<0.05) a, chroma and % oxymyoglobin during display. Hp-LL also had the highest metmyoglobin (MMb) reducing activity and OC among all the samples, thus, the greatest color stability, although very dark throughout storage, with lowest values for lightness (L) and yellowness (b). Np-LL also exhibited relatively high color stability, as a result of its lower % MMb and OC and higher MRA than psoas muscle samples. The 0.2 unit difference of the pH between Hp and Np psoas muscle, resulted in the difference of the color intensity, not the color stability. Interestingly, high pH psoas muscle (Hp-PM) did not have better color stability than Np-PM, and in fact had lower color stability than even Np-LL. The similar level of OC and lipid oxidation cannot explain the difference in color stability between Hp-PM and Np-LL. Conclusion: The Hp does not always show better color stability compared with Np beef, which depends on the muscle type. The balance of MRA and OC is important to keep the color in great intensity and stability in the meantime.

The Study on the Image for Same-Color Coordination of Makeup and Clothing (메이크업과 의복의 동일색상 코디네이션에 따른 이미지 연구)

  • Choi, Su-Kyung;Jeong, Su-Jin
    • Korean Journal of Human Ecology
    • /
    • v.17 no.2
    • /
    • pp.355-366
    • /
    • 2008
  • The purpose of this study is to investigate the effects of eye shadow color(brown, purple), lipstick color(red, red purple, and yellow red), and lipstick tone(vivid, light, dull, and dark) and clothing tone(vivid, light, dull, and dark) on image formation. Sets of stimulus and response scales(7 point semantic) were used as experimental materials. The stimuli consisted of 64 color photos manipulated with the combination of eye shadow color, lipstick color, lipstick tone, and clothing tone using computer simulation. The subjects were 384 female undergraduates living in Gyeongnam Province. Image factor of the stimulus was composed of 4 different components: attractiveness, visibility, cuteness, and stability. Eye shadow color, lipstick tone and clothing tone independently influenced on visibility, cuteness, and stability. Lipstick color independently influenced on the stability. In color coordination of clothing and makeup of the same hue, 1) visibility image can be created by the coordination of eye shadow color with lipstick color or clothing tone, or lipstick color with lipstick tone. 2) Cuteness image can be produced by the coordination of eye shadow color with lipstick or clothing tone, lipstick color with lipstick or clothing tone. 3) Stability image can be showed by the coordination of eye shadow color with lipstick tone.

Color stability of laboratory glass-fiber-reinforced plastics for esthetic orthodontic wires

  • Inami, Toshihiro;Tanimoto, Yasuhiro;Minami, Naomi;Yamaguchi, Masaru;Kasai, Kazutaka
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.130-135
    • /
    • 2015
  • Objective: In our previous study, glass-fiber-reinforced plastics (GFRPs) made from polycarbonate and glass fibers were prepared for esthetic orthodontic wires using pultrusion. These laboratory GFRP wires are more transparent than the commercially available nickel-titanium wire; however, an investigation of the color stability of GFRP during orthodontic treatment is needed. Accordingly, in the present study, the color stability of GFRP was assessed using colorimetry. Methods: Preparation of GFRP esthetic round wires (diameter: 0.45 mm [0.018 inch]) using pultrusion was described previously. Here, to investigate how the diameter of fiber reinforcement affects color stability, GFRPs were prepared by incorporating either $13-{\mu}m$ (GFRP-13) or $7-{\mu}m$ glass (GFRP-7) fibers. The color changes of GFRPs after 24 h, and following 1, 2, and 4 weeks of coffee immersion at $37^{\circ}C$, were measured by colorimetry. We evaluated the color stability of GFRPs by two evaluating units: the color difference (${\Delta}E^*$) and National Bureau of Standards (NBS). Results: After immersion, both GFRPs showed almost no visible color change. According to the colorimetry measurements, the ${\Delta}E^*$ values of GFRP-13 and GFRP-7 were 0.73-1.16, and 0.62-1.10, respectively. In accordance with NBS units, both GFRPs showed "slight" color changes. As a result, there were no significant differences in the ${\Delta}E^*$ values or NBS units for GFRP-13 or GFRP-7. Moreover, for both GFRPs, no significant differences were observed in any of the immersion periods. Conclusions: Our findings suggest that the GFRPs will maintain high color stability during orthodontic treatment, and are an attractive prospect as esthetic orthodontic wires.

The Relationship Between Color & Clothing Color Preference And Personality Traits Among High School Girls (여고생의 복색 선호와 성격특성과의 상관연구)

  • Im Nha Soo;Myeong Sook Han
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 1986
  • The purpose of this study was to investigate the relationship between color & clothing color preferences and three personality traits. Personality traits were measured with chung's Personality Scale. The questionare measuring Color & Clothing color preferences consisted of items designed to assess color preference, color repugnance clothing color preferences. These questionaire were administered to 302 senior high school girls in Seoul. Statistical analysis consisted of corelation and chi-square-test. The result were; 1) Activity, stability, sociability was no significant related to color preference. 2) Activity, sociability was positively related to color repugnance in Value but stability was no significant. 3) Sociability and stability was positively related to color preference, but activity and stability was no significant. 4) There was a positive relationship between color preference and clothing color preference. (r=0.8867) 5) The most preferred colors were white, light blue, and light green. The most repugnated colors were light red, dark red purple, and dark yellow. 6) The most preferred clothing colors were yellow, pink, and green in Spring, white and blue in Summer all kinds of colors, colors in Autumn, and Black and Grey in Winter.

  • PDF

COLOR STABILITY OF CURRENT PROSTHETIC COMPOSITES UNDER ACCELERATED AGING AND IMMERSION IN A COFFEE SOLUTION

  • Kim, Hyo-Jin;Heo, Seong-Joo;Koak, Jai-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.225-235
    • /
    • 2002
  • The color stability of current prosthetic composites is unknown, even though the quality of composite materials has been improving. This study examined the intrinsic color stability of various current prosthetic resins (ceramic-polymers) after an accelerated aging process and the extrinsic color stability after immersion in a coffee solution. By comparing the amount of discoloration after aging with that without aging, the effect of the accelerated aging process on external discoloration could be evaluated. Three current prosthetic composites (Artglass, Targis, Sculpture), one light polymerized direct composite (Z100) and one dental porcelain control (Ceramco) were assessed. The color changes (${\Delta}$E) of all the specimens were determined using the CIE $L^{*}a^{*}b^{*}$ color order system with a reflected spectrophotometer. The results were as follows: 1. The prosthetic composite materials subjected to the accelerated aging test showed no significant difference in color changes (p >.05). 2. In the coffee solution immersion test after the aging process, the color changes of the Targis and Artglass groups were not different from that of the Z100 group, which showed the highest color change. 3. In the immersion only test, a significantly high color change was observed in the sculpture glazing group. 4. The aging process influenced on the color changes more in the Targis, Artglass and Z100 groups than in the Sculpture and Ceramco groups.

A STUDY ON THE COLOR STABILITY OF PORCELAIN FOR PORCELAIN FUSED TO METAL CROWN (도재전장주조관에 사용되는 도재의 색안정성에 관한 연구)

  • Ryu, So-Young;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.73-84
    • /
    • 2000
  • Dental porcelain should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental porcelain has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 types of porcelain(Vintage, VMK 95, CERAMCO II). The porcelain were divided into groups by 2 types of treatment(glazing or non-glazing and thermocycling or non-thermocycling). The porcelain were dyed with methylene blue and distilled water, and then the color stability was evaluated with a spectrophotometer The results were as follows; 1. The color change of porcelain increased in the order of VMK 95, Vintage, CERAMCO II. But there was no significant difference. 2. The color change decreased in the glazing group compared to the non-glazing group(p<0.05). 3. The color change increased after thermocycling But there was no significant difference. 4. The color change according to dye method was significantly larger with methylene blue copared to distilled water(p<0.05).

  • PDF