• Title/Summary/Keyword: Color line Sensor

Search Result 29, Processing Time 0.029 seconds

On-Line Real Time Soil Sensor

  • Shibusawa S.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.45-49
    • /
    • 2003
  • Achievements in the real-time soil spectro-photometer are: an improved soil penetrator to ensure a uniform soil surface under high speed conditions, real-time collecting of underground soil reflectance, getting underground soil color images, use of a RTK-GPS, and all units are arranged for compactness. With the soil spectrophotometer, field experiments were conducted in a 0.5 ha paddy field. With the original reflectance, averaging and multiple scatter correction, Kubelka-Munk (KM) transformation as soil absorption, its 1st and 2nd derivatives were calculated. When the spectra was highly correlated with the soil parameters, stepwise regression analysis was conducted. Results include the best prediction models for moisture, soil organic matter (SOM), nitrate nitrogen ($NO_3-N$), pH and electric conductivity (EC), and soil maps obtained by block kriging analysis.

  • PDF

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

Development of RGBW Dimming Control Sensitivity Lighting System based on the Intelligence Algorithm (지능형 알고리즘 기반 RGBW Dimming control LED 감성조명 시스템 개발)

  • Oh, Sung-Kwun;Lim, Sung-Joon;Ma, Chang-Min;Kim, Jin-Yul
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.3
    • /
    • pp.359-364
    • /
    • 2011
  • The study uses department of the sensitivity and fuzzy reasoning, one of artificial intelligence algorithms, so that develop LED lighting system based on fuzzy reasoning for systematical control of the LED color temperature. In the area of sensitivity engineering, by considering the relation between color and emotion expressed as an adjective word, the corresponding sensitivity word can be determined, By taking into consideration the relation between the brain wave measured from the human brain and the color temperature, the preferred lesson subject can be determined. From the decision of the sensitivity word and the lesson subject, we adjust the color temperature of RGB (Red, Green, Blue) LED. In addition, by using the information of the latitude and the longitude from GPS(Global Positioning System), we can calculate the on-line moving altitude of sun. By using the sensor information of both temperature and humidity, we can calculate the discomfort index. By considering the altitude of sun as well as the value of the discomfort index, the illumination of W(white) LED and the color temperature of RGB LED can be determined. The (LED) sensitivity lighting control system is bulit up by considering the sensitivity word, the lesson subject, the altitude of sun, and the discomfort index The developed sensitivity lighting control system leads to more suitable atmosphere and also the enhancement of the efficiency of lesson subjects as well as business affairs.

Implementation of Visualization System for Multi-sensor Data Analysis (다중 센서 데이터의 분석을 위한 가시화 시스템의 구현)

  • Kwon Hyuk-Don;Koo Sang-Ok;Jung Seung-Dae;Kim Bok-Dong;Jung Soon-Ki
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.415-418
    • /
    • 2006
  • 다양한 데이터에 대해 정확한 분석이 요구되는 분야가 증가하면서, 데이터를 효율적으로 가시화하는 방법에 대한 요구도 증가하고 있다. 분석에 효율적인 가시화란 데이터의 특성을 잘 표현함으로써 분석가가 데이터를 직관적으로 이해할 수 있도록 도와주는 것을 말한다. 이를 통해 데이터를 분석하는 시간을 줄이고 정확한 결과를 얻는데 도움을 준다. 본 논문에서는 가스 배관을 검사하기 위한 Geometry 피그(PIG:Pipeline Inspection Gauge)와 MFL 피그로부터 얻어지는 데이터를 다양한 방법으로 가시화하고 분석에 효과적인 가시화와 시스템의 구현에 대해 다룬다. 각 피그의 다중 센서를 통해 얻어온 데이터를 Line graph, Pseudo Color Image, 3D Surface, Polar View, 3D Pipeline View와 같은 다양한 방법으로 가시화하고 view들 간의 동기화 및 사용자 지정 view 배치를 통해 빠르고 정확한 분석을 가능하게 하는 여러 가지 방법에 대해 설명한다.

  • PDF

Rapid Detection Kit for Salmonella typhimurium (살모넬라 식중독균 신속 검출용 간이 진단키트)

  • Kim, Gi-Young;Yang, Gil-Mo;Park, Saet-Byeol;Kim, Yung-Hwun;Lee, Kang-Jin;Son, Jae-Yong;Kim, Hyuck-Joo;Lee, Sae-Rom
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.140-146
    • /
    • 2011
  • This study was performed to develop a rapid test kit for pathogenic Salmonella in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and biotin conjugated Salmonella antibodies were used as a tag and a receptor, respectively. Manually spotted Salmonella antibody and Neutravidin on nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Salmonella typhimurium in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Salmonella spiked in PBS. Also, the rapid test kit could detect $10^6$ cfu/mL of Salmonella in chicken meat extract.

Rapid Detection Kit for Staphylococcus aureus (황색포도상구균 신속 검출용 간이 진단키트)

  • Kim, Gi-Young;Park, Saet-Byeol;Moon, Ji-Hea;Lee, Sang-Dae;Lee, Sea-Rom;Jang, Youn-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.139-146
    • /
    • 2013
  • This study was performed to develop a rapid test kit for pathogenic Staphylococcus in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and Staphylococcus antibodies were used as a tag and a receptor, respectively. Manually spotted Staphylococcus antibody and anti-mouse antibody on the surface of nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Staphylococcus aureus in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Staphylococcus spiked in PBS. Also, the rapid test kit could detect $10^5$ cfu/mL of Staphylococcus in chicken meat extract.

A Road Luminance Measurement Application based on Android (안드로이드 기반의 도로 밝기 측정 어플리케이션 구현)

  • Choi, Young-Hwan;Kim, Hongrae;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.49-55
    • /
    • 2015
  • According to the statistics of traffic accidents over recent 5 years, traffic accidents during the night times happened more than the day times. There are various causes to occur traffic accidents and the one of the major causes is inappropriate or missing street lights that make driver's sight confused and causes the traffic accidents. In this paper, with smartphones, we designed and implemented a lane luminance measurement application which stores the information of driver's location, driving, and lane luminance into database in real time to figure out the inappropriate street light facilities and the area that does not have any street lights. This application is implemented under Native C/C++ environment using android NDK and it improves the operation speed than code written in Java or other languages. To measure the luminance of road, the input image with RGB color space is converted to image with YCbCr color space and Y value returns the luminance of road. The application detects the road lane and calculates the road lane luminance into the database sever. Also this application receives the road video image using smart phone's camera and improves the computational cost by allocating the ROI(Region of interest) of input images. The ROI of image is converted to Grayscale image and then applied the canny edge detector to extract the outline of lanes. After that, we applied hough line transform method to achieve the candidated lane group. The both sides of lane is selected by lane detection algorithm that utilizes the gradient of candidated lanes. When the both lanes of road are detected, we set up a triangle area with a height 20 pixels down from intersection of lanes and the luminance of road is estimated from this triangle area. Y value is calculated from the extracted each R, G, B value of pixels in the triangle. The average Y value of pixels is ranged between from 0 to 100 value to inform a luminance of road and each pixel values are represented with color between black and green. We store car location using smartphone's GPS sensor into the database server after analyzing the road lane video image with luminance of road about 60 meters ahead by wireless communication every 10 minutes. We expect that those collected road luminance information can warn drivers about safe driving or effectively improve the renovation plans of road luminance management.

Thermal Transfer Pixel Patterning by Using an Infrared Lamp Source for Organic LED Display (유기 발광 소자 디스플레이를 위한 적외선 램프 소스를 활용한 열 전사 픽셀 패터닝)

  • Bae, Hyeong Woo;Jang, Youngchan;An, Myungchan;Park, Gyeongtae;Lee, Donggu
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • This study proposes a pixel-patterning method for organic light-emitting diodes (OLEDs) based on thermal transfer. An infrared lamp was introduced as a heat source, and glass type donor element, which absorbs infrared and generates heat and then transfers the organic layer to the substrate, was designed to selectively sublimate the organic material. A 200 nm-thick layer of molybdenum (Mo) was used as the lightto-heat conversion (LTHC) layer, and a 300 nm-thick layer of patterned silicon dioxide (SiO2), featuring a low heat-transfer coefficient, was formed on top of the LTHC layer to selectively block heat transfer. To prevent the thermal oxidation and diffusion of the LTHC material, a 100 nm-thick layer of silicon nitride (SiNx) was coated on the material. The fabricated donor glass exhibited appropriate temperature-increment property until 249 ℃, which is enough to evaporate the organic materials. The alpha-step thickness profiler and X-ray reflection (XRR) analysis revealed that the thickness of the transferred film decreased with increase in film density. In the patterning test, we achieved a 100 ㎛-long line and dot pattern with a high transfer accuracy and a mean deviation of ± 4.49 ㎛. By using the thermal-transfer process, we also fabricated a red phosphorescent device to confirm that the emissive layer was transferred well without the separation of the host and the dopant owing to a difference in their evaporation temperatures. Consequently, its efficiency suffered a minor decline owing to the oxidation of the material caused by the poor vacuum pressure of the process chamber; however, it exhibited an identical color property.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.