• 제목/요약/키워드: Collimation

검색결과 113건 처리시간 0.024초

SPDT를 이용한 대구경 Collimation Reflector 가공 연구 (A study on the manufacture of Large Collimation Reflector using SPDT)

  • 김건희;홍권희;김효식;박지영;박순섭;원종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.897-900
    • /
    • 2002
  • The collimation mirror will be used for thermal vacuum testing of spacecraft. The reflection mirror system to generate parallel beam inside the thermal vacuum chamber. A 600mm diameter aspheric Collimation mirror was fabricated by ultra-precision single point diamond turning (SPDT). Aluminum alloy for mirror substrates is known to be easily machining, but not polishable due to its ductility. Aspheric large collimation reflector without a conventional polishing process, the surface roughness of 10nmRa, and the from error of $\lambda/2 ~\lambda/4(\lambda$ =632.8 nm) for reference curved surface 600 mm has been required. The purpose of this research is to find the optimum machining conditions for reflector cutting of A16061-T651 and apply the SPDT technique to the manufacturing of ultra precision optical components of metal aspheric reflector.

  • PDF

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block

  • Baek, Seung Woo;Ryu, Jae Sung;Jung, Cheol Hee;Lee, Joo Han;Kwon, Won Kyoung;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제26권2호
    • /
    • pp.148-153
    • /
    • 2013
  • Background: C-arm fluoroscope has been widely used to promote more effective pain management; however, unwanted radiation exposure for operators is inevitable. We prospectively investigated the differences in radiation exposure related to collimation in Medial Branch Block (MBB). Methods: This study was a randomized controlled trial of 62 MBBs at L3, 4 and 5. After the patient was laid in the prone position on the operating table, MBB was conducted and only AP projections of the fluoroscope were used. Based on a concealed random number table, MBB was performed with (collimation group) and without (control group) collimation. The data on the patient's age, height, gender, laterality (right/left), radiation absorbed dose (RAD), exposure time, distance from the center of the field to the operator, and effective dose (ED) at the side of the table and at the operator's chest were collected. The brightness of the fluoroscopic image was evaluated with histogram in Photoshop. Results: There were no significant differences in age, height, weight, male to female ratio, laterality, time, distance and brightness of fluoroscopic image. The area of the fluoroscopic image with collimation was 67% of the conventional image. The RAD ($29.9{\pm}13.0$, P = 0.001) and the ED at the left chest of the operators ($0.53{\pm}0.71$, P = 0.042) and beside the table ($5.69{\pm}4.6$, P = 0.025) in collimation group were lower than that of the control group ($44.6{\pm}19.0$, $0.97{\pm}0.92$, and $9.53{\pm}8.16$), resepectively. Conclusions: Collimation reduced radiation exposure and maintained the image quality. Therefore, the proper use of collimation will be beneficial to both patients and operators.

데오드라이트를 이용한 자동 시준에 의한 측정 정확도에 관한 연구 (Study on Measurement Accuracy by Auto-Collimation using Theodolite)

  • 이병기;권재욱;윤용식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1793-1796
    • /
    • 2005
  • The auto-collimation by using theodolite has been accomplished for the straight measurement and the horizontality adjustment. But according to the procedure of auto-collimation or composition of the measurement equipment, an error of the measurement can be occurred. Therefore, this paper accomplished the research for enhancement of measurement accuracy according to measurement procedure of auto-collimation. For that, it has been compared the study of the combination of several precise measurement equipment with using of several theodolite.

  • PDF

혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가 (Evaluation of Roadmap Image Quality by Parameter Change in Angiography)

  • 공창기;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 이 연구의 목적은 Roadmap 영상에서 화질에 영향을 미치는 인자들을 알아보기 위한 것으로, 조영제의 희석률, Collimation Field, Flow Rate를 변화하여 연구를 하였다. 화질의 정량적인 평가를 위해, 아크릴를 이용하여 3mm 혈관모형의 Water Phantom을 자체 제작하였고, 자체 제작한 혈관모형의 Water Phantom으로 Roadmap 영상을 획득하고, SNR(Signal to Noise Ratio)과 CNR(Contrast to Noise Ratio)을 분석하였다. CM : N/S 희석률 변화에 대한 연구에서 CM : N/S 희석률을 (100%~10% : 100%)로 변화를 주었으며, 혈관모형 Water Phantom을 이용하여 촬영한 Roadmap 영상의 SNR과 CNR의 측정 결과 CM에 N/S 희석률이 높아질수록 SNR의 측정값이 점차적으로 낮아짐을 나타났고, CNR의 측정값도 점차적으로 낮아짐을 나타났다. 결론적으로 CM : N/S의 희석률이 높아질수록 SNR과 CNR 낮아짐을 확인하였고, CM : N/S의 희석률(100%~70 : 30%)에서 유의한 이미지를 얻을 수 있음을 확인하였다. Collimation Field 변화에 대한 연구에서 혈관모형 Water Phantom을 이용하여 Colimation Field를 혈관모형 중심으로 좌, 우 2 cm 간격으로 좁히면서 0 cm, 2 cm, 4 cm, 6 cm, 8 cm 10 cm, 12 cm으로 각각 변화를 주었으며, Roadmap을 촬영한 영상의 SNR과 CNR의 측정 결과는 Collimation Field를 혈관모형 중심으로 좁힐수록 SNR과 CNR의 측정값이 증가하는 것을 확인할 수 있었다. Flow rate 변화에 대한 연구에서 Autoinjector의 Volume을 15로 일정하게 하고, Flow Rate를 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 으로 각각 변화를 주었다. 혈관모형 Water Phantom을 이용하여 Roadmap 영상을 촬영한 이미지의 SNR과 CNR의 측정 결과 Flow Rate를 증가했을 때, SNR의 측정값이 점차적으로 감소하다가 Flow Rate 9~10에서 SNR의 측정값이 점차적 증가를 보였고, CNR의 측정값도 점차적으로 감소하다가 Flow Rate 9~10에서 CNR의 측정값이 점차적으로 증가를 보였다. 그러나 ROI Mean 값과 Background Mean 값으로 SNR과 CNR의 상관관계를 확인할 수 없었다. 상관관계를 확인하기 위해 Flow Rate 변화에 따른 Roadmap 연구는 향후 더 많은 연구로 확인해야 할 것으로 사료된다. 결론적으로 Roadmap 영상의 화질에 영향을 미치는 인자들을 알아보기 위해 조영제의 희석률, Collimation Field, Flow Rate 변화에 대한 연구에서 조영제에 N/S의 희석률이 증가할수록 SNR과 CNR이 낮아져 화질과 대조도가 낮아지는 것을 확인하였으며, Collimation Field를 좁힐수록 SNR과 CNR이 증가하여 화질과 대조도가 높아지는 것을 확인하였다. 그러나 Flow Rate 변화에 대한 연구에서는 상관관계를 확인할 수 없었다. 검사 및 시술을 할 때 신장의 영향을 최소화하기 위해 적절한 조영제 농도 선택과 대조도 향상 및 피폭 감소를 위한 적절한 Collimation Field를 사용하는 것이 유용할 것으로 판단된다.

인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향 (Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom)

  • 왕지환;이희천
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.495-501
    • /
    • 2014
  • 본 연구는 다양한 전산화단층촬영기기와 촬영 프로토콜의 차이에 따른 모형물의 부피와 Hounsfield unit (HU) 수치의 차이를 평가하고 이 후 전산화단층촬영술을 이용하여 결석의 부피와 HU 수치를 포함한 다양한 인자들을 평가하고 이 중 체외충격파쇄석술에 의한 결석의 분쇄를 예측할 수 있는 인자를 찾고자 하였다. 다양한 직경의 100 HU 인공종양 5개를 (직경 3.0-12.0 mm) 이용하여 모형물을 만들었으며, 이 모형물의 부피와 HU 수치를 Siemens사의 2채널, GE사의 4채널과 64채널, 그리고 Philips사의 64채널 전산화단층촬영기기를 사용하여 평가하였다. 또한 각각의 전산화단층촬영기기에서 동일한 조건으로 collimation만 thin collimation과 thick collimation으로 변화를 주어 모형물을 촬영한 후 모형물의 부피와 HU 수치를 평가하였다. 평가자간 (inter-observer) 재현성을 평가하기 위해 3명의 수의영상의학 전공의가 연구에 참여하였으며 이중 한 명의 수의사가 평가자내 (intra-observer) 재현성을 평가하기 위해 모형물의 부피와 HU 수치를 2주 간격으로 총 3번 측정하였다. 부피의 평가자간 재현성과 평가자내 재현성은 k=0.9994, k=0.9969로 아주 우수하였으며, HU 수치의 평가자간 재현성과 평가자내 재현성 역시 k=0.9984, k=0.9655로 아주 우수하였다. 다양한 전산화단층촬영기기와 collimation 차이에 따른 부피와 HU 수치의 차이는 모두 통계학적으로 유의적인 차이를 나타내지 않았다. 그러나 부피의 경우 collimation이 얇을수록 부피의 정확도가 증가하는 경향을 보였다. 본 연구 결과를 토대로 향후 진행될 결석의 부피 및 HU 수치의 평가 시 전산화단층촬영기기의 차이에 따른 영향을 받지 않으리라 판단되어 Siemens사의 2채널 전산화단층촬영기기만을 사용하였으며, 비록 통계학적으로 유의적인 차이는 없었지만 부피의 정확도를 더 높이기 위하여 얇은 collimation을 사용하였다.

The Relation between the Spectral Lag and the Collimation-Corrected Luminosity in Gamma-Ray Bursts

  • Jo, Yun-A;Chang, Heon-Young
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.51.3-52
    • /
    • 2015
  • Gamma-Ray Bursts(GRBs) are the most violent event in the universe, whose detection rate is a few in a day. The spectral lag, which is commonly observed in the observed light curves of GRBs, is a difference in arrival times of the high-energy and low-energy photons. The relation between the spectral lag and the luminosity of the observed GRBs is shown to be anti-correlated in previous studies. In reported relations to date, the isotropic luminosity has been assumed. On the other hand, GRBs are likely to emit its energy through a beamed jet. In this study, we attempt to obtain the relation between the spectral lag and the collimation-corrected luminosity. We have calculated collimation-corrected luminosities and opening angles using the observed light curves taken from a database of Swift/BAT, XRT. We expect to increase its significance level by expanding a sample size compared with those previously analyzed.

  • PDF

양방향 층밀리기 간섭계를 이용한 레이저 광선의 시준시험 (Improved Collimation Testing by using Bidirectional Shearing Interferometer)

  • 이윤우;조현모;이인원
    • 한국광학회지
    • /
    • 제3권3호
    • /
    • pp.172-177
    • /
    • 1992
  • 레이저 광선의 시준정도를 정확하게 측정하기 위하여 새로운 양방향 층밀리기 간섭계를 구성하였다. 한개의 쐐기판과 두개의 평면거울로 구성된 간섭계는 서로 반대방향으로 층밀리기된 두개의 간섭무늬 모양에 의햐여 시준정도를 나타낸다. 새로운 간섭계는 기존의 방법들에 비하여 분해능이 두 배로 향상되었으며 또한 간섭무늬 자체내에 시준된 경우를 나타내는 기준표시도 갖는다. 쐐기판의 $90^{\circ}$ 회전에 의한 간섭무늬 변화와 두 간섭무늬를 서로 중첩시켜 생긴 무아레 무늬 등에 의한 시준측정에 관하여 자세리 논하였으며 측정결과도 제시하였다.

  • PDF