• Title/Summary/Keyword: College health

Search Result 33,493, Processing Time 0.066 seconds

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

Study on Fatty Liver Duagnosed by Abdominal Ultrasonography and Clinical Laboratory Findings (초음파로 진단된 지방간과 임상검사수치의 관련성에 관한 비교 연구)

  • Yang, Jeong-Hwa
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • This study obtained the following conclusions by making a comparative study on fatty liver diagnosed by abdominal ultrasonography and clinical laboratory findings. I surveyed the value of abdominal ultrasound in 400 patients without clinical symptoms at C Health Clinic Center, Seoul. 1. Compare with blood pressure was high(systolic/diastolic) in 7.5%/4.5% on persons who were diagnosed fatty liver. 2. At the time of the diagnosis, Total cholesterol level was increased in fatty liver patients, HDL-cholesterol level was high in fatty liver patients. And Trigryceride level was increased in fatty liver persons, LDL-cholesterol was high in fatty liver persons. 3. SGOT level was increased in 5.5% on patients who were diagnosed fatty liver, 0% on persons who were normal and SGPT level was high in 29.5% on people who were diagnosed fatty liver, 0% on patients who were diagnosed normal.

  • PDF

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF

A study on the optimization of referring method about medical images using MIH(Medical Image History) (MIH(Medical Image History)을 이용한 의료영상조회의 최적화 연구)

  • Kim, Sun-Chil;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.57-64
    • /
    • 2002
  • The recent development of embodiment technology of the medical images makes most medical institutions introduce PACS(Picture Archiving and Communication System) in haste. However lots of PACS solutions, currently developed and distributed, haven't been able to serve the convenience of users and to satisfy user's demand because of economic limitations and administrator-oriented considerations in the process of development. So we have developed MIH(Medical Image History), by which we can search and refer to the patient's medical images and information with few restrictions of time and space for diagnosis and treatment. This program will contribute to the improvement in the medical environment and meet the clients' need. We'll make more effort to develop the application which insures the better quality of medical images. MIH manages the patient's image files and medical records like film chart in connection with time. This trial will contribute to the reduction of the economical loss caused by unnecessary references and improve the quality in the medical services. The demand on the development or the program which refers to the medical +ata quickly and keeps them stable will be continued by the medical institute. This will satisfy the client's demand and improve the service to the patients in that tile program will be modified from the standpoint of the users. MIH is trying to keep user-oriented policy and to apply the benefit of the analog system to the digital environment. It is necessary to lead the public to the better understanding that the systematic management and referring of the medical images is as important as the quality of the images.

  • PDF

Extracorporeal Shock Wave Lithotripsy for Renal Stone with Infundibular Stenosis (신누두부 협착이 있는 신장결석의 체외충격파쇄석술)

  • Lee, Won-Hong;Son, Soon-Yong;Kang, Seong-Ho;Lee, Yong-Moon;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.71-74
    • /
    • 2006
  • We analyzed retrospectively our experience to evaluate an effect of extracorporeal shock wave lithotripsy (ESWL) for renal stone with infundibular stenosis. From January 2002 to August 2005, 35 patients with renal stone with infundibular stenosis were treated with ESWL. The diagnosis of infundibular stenosis was made by intraveneous pyelography or retrograde pyelography. The final follow-up check was performed by simple abdominal film or computed tomography and interview after 6 months to 24 months (mean 10 months). 7(20.0%) of 35 patients was freed completely, but Stone free rate including less than 2 mm size was 80%(28/35). 30(85.7%) patients became asymptomatic, 4(11.4%) patients were continued, and 1(2.9%) patient was required the percutaneous nephrostolithotomy. Although ESWL has a low complete stone free rate, We suggest that renal stone with infundibular stenosis should be treated with ESWL, because that is likely to produce a high symptom free and low complications.

  • PDF

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

A Study on Variation Types in Celiac Axis and Superior Mesenteric Artery using 3D Volume Rendering of MDCT (MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위 형태에 관한연구)

  • Lee, Jeong-Keun;Jang, Young-Ill;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this study was to evaluate the variation which based on Celiac axis and SMA using by CT volume rendering images. 613 patients underwent abdominal CTA, there were 552 patients (99.05%, TypeI, II) with normal anatomical form and 61 (9.95%, Type III~XII) with variation. TypeI was 339(55.31%), Type II was 213 (34.74%), Type III was 18 (2.93%), Type IV was 12 patients (1.95%), Type V was 11 patient (1.79%), Type VI was 9 patients (1.46%), Type VII was 6 patients (0.97%), Type VIII was 1 patient (0.16%), Type IX was 1 patient (0.16%), Type X was 1 patient (0.16%), Type XI was 1 patient (0.16%), and Type XII was 1 patient (0.16%) into totally new types of variation. In conclusion, we could found 9 new types of variation by classifying based on celiac axis and superior mesenteric artery. These results were considered to be an important opportunity for a new vessel map.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Enhancement of Tomato Tolerance to Biotic and Abiotic Stresses by Variovorax sp. PMC12 (Variovorax sp. PMC12 균주에 의한 토마토의 생물학 및 비생물학적 스트레스 저항성 증진)

  • Kim, Hyeon Su;Lee, Shin Ae;Kim, Yiseul;Sang, Mee kyung;Song, Jaekyeong;Chae, Jong-Chan;Weon, Hang-Yeon
    • Research in Plant Disease
    • /
    • v.24 no.3
    • /
    • pp.221-232
    • /
    • 2018
  • Rhizobacteria play important roles in plant growth and health enhancement and render them resistant to not only biotic stresses but also abiotic stresses, such as low/high temperature, drought, and salinity. This study aimed to select plant growth promoting rhizobacteria (PGPR) with the capability to mitigate biotic and abiotic stress effects on tomato plants. We isolated a novel PGPR strain, Variovorax sp. PMC12 from tomato rhizosphere. An in vitro assay indicated that strain PMC12 produced ammonia, indole-3-acetic acid (IAA), siderophore, and 1-aminocyclopropane-1-carboxylic acid (ACC) deaminase, which are well-known traits of PGPR. The aboveground fresh weight was significantly higher in tomato plants treated with strain PMC12 than in non-treated tomato plants under various abiotic stress conditions including salinity, low temperature, and drought. Furthermore, strain PMC12 also enhanced the resistance to bacterial wilt disease caused by Ralstonia solanacearum. Taken together, these results indicated that strain PMC12 is a promising biocontrol agent and a biostimulant to reduce the susceptibility of plants to both abiotic and biotic stresses.

Prospective phase II trial of regional hyperthermia and whole liver irradiation for numerous chemorefractory liver metastases from colorectal cancer

  • Yu, Jeong Il;Park, Hee Chul;Choi, Doo Ho;Noh, Jae Myoung;Oh, Dongryul;Park, Jun Su;Chang, Ji Hyun;Kim, Seung Tae;Lee, Jeeyun;Park, Se Hoon;Park, Joon Oh;Park, Young Suk;Lim, Ho Yeong;Kang, Won Ki
    • Radiation Oncology Journal
    • /
    • v.34 no.1
    • /
    • pp.34-44
    • /
    • 2016
  • Purpose: A prospective phase II trial was conducted to evaluate the effectiveness and toxicity of regional hyperthermia and whole liver irradiation (WLI) for numerous chemorefractory liver metastases from colorectal cancer. Materials and Methods: Enrolled patients had numerous chemorefractory hepatic metastases from colorectal cancer. Five sessions of hyperthermia and seven fractions of 3-gray WLI were planned. Health-related quality of life (HRQoL) was determined using the Korean version of the European Organization for Research and Treatment of Cancer quality of life questionnaire C-30 and the Functional Assessment of Cancer Therapy-Hepatobiliary version 4.0. Objective and pain response was evaluated. Results: A total of 12 patients consented to the study and the 10 who received WLI and hyperthermia were analyzed. WLI was completed as planned in nine patients and hyperthermia in eight. Pain response was partial in four patients and stable in four. Partial objective response was achieved in three patients (30.0%) and stable disease was seen in four patients at the 1-month follow-up. One patient died 1 month after treatment because of respiratory failure related to pleural metastasis progression. Other grade III or higher toxicities were detected in three patients; however, all severe toxicities were related to disease progression rather than treatment. No significant difference in HRQoL was noted at the time of assessment for patients who were available for questionnaires. Conclusion: Combined WLI and hyperthermia were well tolerated without severe treatment-related toxicity with a promising response from numerous chemorefractory hepatic metastases from colorectal cancer.