• Title/Summary/Keyword: Cold-pressure

Search Result 908, Processing Time 0.026 seconds

3-Dimensional Calculation on Cold Air Flow Characteristics in a Refrigerator (냉장고 내부의 냉기 유동특성에 관한 3차원 해석(I))

  • Oh, Min-Jung;Lee, Jae-Heon;Oh, Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.382-395
    • /
    • 1995
  • A numerical study has been performed on flow characteristics in a domestic refrigerator whose size is $540mm{\times}1,530mm{\times}680mm$, considering existence of a fan and evaporator. The flow field has been simulated with the low Reynolds number $k-\bar{\varepsilon}$ turbulent model and SIMPLE algorithm based on the finite volume method. The region of fan which makes driving force for cold air distribution was modeled as a region in which momentum sources are generated uniformly. The concept of the distributed pressure resistance was applied to describe the momentum loss from evaporator. The result showed that the rate of cold air distribution into freezing room and cold storage room was almost 7 : 3.

  • PDF

Back-pressure cold forging analysis to minimize non-forming area of gear teeth (기어 치형의 미성형 구간 최소화를 위한 배압 냉간 단조 성형 해석)

  • Lee, Yongwoo;Kim, Janghoon;Kwon, Jongho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.256-262
    • /
    • 2016
  • This study performed the back-pressure cold forging analysis to minimize the non-forming area of gear teeth for the output hub and reaction hub in automatic transmission. Two important factors of the back-pressure cold forging process, the load of the punch and the backup force applied to the sleeve, were determined through displacement control analysis. The non-forming area of the gear teeth was compared with both cases of the displacement control analysis and load control analysis, and their solution is similar to the measuring result of a real workpiece. The results show that the load of the punch is dependent on the reduction area of the workpiece, and the backup force applied to the sleeve is determined with regard to the cross-section-area of sleeve. This analysis procedure can be useful and effective in determining the manufacturing condition of the back-pressure cold forging process to minimize the non-forming area.

Design and Validation Test of Rocket Engine Head Generating High Temperature and High Pressure Steam (고온고압 증기 발생장치의 설계 및 예비운용시험)

  • Park, Jinsoo;Yu, Isang;Oh, Junghwa;Ko, Youngsung;Kim, Kyungseok;Shin, Dongsun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.637-642
    • /
    • 2017
  • In this study, cold flow and combustion tests are conducted and analyzed to validate designed rocket engine head generating high temperature/pressure steam. At first, uni-injector was designed and manufactured, and cold flow test was conducted. Through this, differential pressure that can supply designed flow rate was confirmed. Also, Each injector's spray pattern were confirmed by patternator. Based on cold flow test results, we selected injectors among the candidates and arranged them on engine head, and cold flow and propellant spray tests were conducted. Finally, combustion test was carried out to analyze the flow rate, pressure, combustion efficiency. As a result, validation of rocket engine head for the development of the high temperature and high pressure steam generator has been completed.

  • PDF

Realistic Large Break Loss of Coolant Accident Mass and Energy Release and Containment Pressure and Temperature Analyses

  • Kwon, Young-Min;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.229-239
    • /
    • 1997
  • To investigate the realistic behavior of mass and energy release and resultant containment response during large break Loss of Coolant accident (LOCA), analyses are performed for Yonggwang (YGN) 3&4 nuclear power plants by using a merged version of RELAP5/CONTEMPT4 computer code. Comparative analyses by using conservative design computer codes are also peformed. The break types analyzed are the double-ended guillotine breaks at the cold leg and hot leg. The design analysis resulted in containment peak pressure during post-blowdown phase for the cold leg break. However, the RELAP5/CONTEMPT4 analyses show that the containment pressure has a peak during blowdown phase, thereafter it decreases monotonously without the second port-blowdown peak. For the hot leg break, revised design analysis shows much lower pressure than that reported in YGN 3&4 final safety analysis report. The RELAP5/CONTEMPT4 analysis shoos similar trend and confirmed that the bypass flow through the broken loop steam generator during post-blowdown is negligibly small compared to that of cold leg break. The low pressure and temperature predicted tv realistic analysis presented in this paper suggest that the design analysis methodology contains substantial margin and it can be improved to provide benefit in investment protection, such as, relaxing plant technical specifications and reducing containment design pressure.

  • PDF

Fuel-Side Cold-Flow Test and Pressure Drop Analysis on Technology Demonstration Model of 75 ton-class Regeneratively-Cooled Combustion Chamber (75톤급 재생냉각 연소기 기술검증시제 연료 수류시험 및 차압 해석)

  • Ahn, Kyu-Bok;Kim, Jong-Gyu;Lim, Byoung-Jik;Kim, Mun-Ki;Kang, Dong-Hyuk;Kim, Seong-Ku;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.807-812
    • /
    • 2011
  • Fuel-side cold-flow tests were performed on the technology demonstration model of a 75 ton-class liquid rocket engine combustion chamber for the first stage of the Korea space launch vehicle II. Pressure drop in the cooling channels of the combustion chamber was measured by changing fuel mass flow rate through a pressure regulating system. Pressure drop in each segment of the chamber could be obtained and a lot of pressure drop was caused by high flow velocity in the nozzle throat segment. The accuracy of a hydraulic analysis method for calculating a pressure loss in cooling channels could be verified by applying it to the cold-flow test conditions.

  • PDF

Fuel-Side Cold-Flow Test and Pressure Drop Analysis on Technology Demonstration Model of 75 ton-class Regeneratively-Cooled Combustion Chamber (75톤급 재생냉각 연소기 기술검증시제 연료 수류시험 및 차압 해석)

  • Ahn, Kyubok;Kim, Jong-Gyu;Lim, Byoungjik;Kim, Munki;Kang, Donghyuk;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.56-61
    • /
    • 2012
  • Fuel-side cold-flow tests were performed on the technology demonstration model of a 75 ton-class liquid rocket engine combustion chamber for the first stage of the Korea space launch vehicle II. Pressure drop in the cooling channels of the combustion chamber was measured by changing fuel mass flow rate through a pressure regulating system. Pressure drop in each segment of the chamber could be obtained and a lot of pressure drop was caused by high flow velocity in the nozzle throat segment. The accuracy of a hydraulic analysis method for calculating a pressure loss in cooling channels could be verified by applying it to the cold-flow test conditions.

Inflow Nozzle Conditions for Improving Vortex Tube Performance (보텍스튜브 성능향상을 위한 유입노즐 조건에 관한 연구)

  • Choi, Hoon-Ki;Yoo, Geun-Jong;Lim, Yun-Seung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.2
    • /
    • pp.68-76
    • /
    • 2018
  • A vortex tube is a simple energy separating device that splits a compressed air stream into a cold and hot stream without any external energy supply or chemical reactions. The efforts of many researchers and designers have been focused on improvement of vortex tube efficiency by changing the parameters affecting vortex tube operation. The effective parameters are nozzle specifications and inflow pressure conditions. Effects of different nozzle cross-sectional area and number of nozzles are evaluated by computational fluid dynamics (CFD) analysis. In this study, CFD analysis of 3-D steady state and turbulent flow through a vortex tube was performed. We investigated the cold air mass flow rate, the cold air temperature, and the cold air heat transfer rate behavior of a vortex tube by utilizing seven straight nozzles and four inflow pressure conditions.

Tensile and Fatigue Behavior of ASS304 for Cold Stretching Pressure Vessels at Cryogenic Temperature (Cold Stretching 압력용기용 ASS304 소재의 극저온 인장 및 피로거동)

  • Choi, Hoon Seok;Kim, Jae Hoon;Na, Seong Hyun;Lee, Youn Hyung;Kim, Sung Hun;Kim, Young Kyun;Kim, Ki Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.5
    • /
    • pp.429-435
    • /
    • 2016
  • Cold stretching(CS) pressure vessels from ASS304 (austenitic stainless steel 304) are used for the transportation and storage of liquefied natural gas(LNG). CS pressure vessels are manufactured by pressurizing the finished vessels to a specific pressure to produce the required stress ${\sigma}_k$. After CS, there is some degree of plastic deformation. Therefore, CS vessels have a higher strength and lighter weight compared to conventional vessels. In this study, we investigate the tensile and fatigue behavior of ASS304 sampled by CS pressure vessels in accordance with the ASME code at cryogenic temperature. From the fatigue test results, we show S-N curves using a statistical method recommended by JSEM-S002. We carried out the fractography of fractured specimens using scanning electron microscopy (SEM).

Relationship between the East-Asian Cold Anomalies in Winter of 2010/11 and Blocking (2010/11년 겨울의 동아시아 한랭 아노말리와 블로킹의 연관성)

  • Choi, Wookap;Kim, Young-Ah
    • Atmosphere
    • /
    • v.26 no.1
    • /
    • pp.193-201
    • /
    • 2016
  • An anomalous cold-weather period occurred during January 2011 in East Asia, and this study investigates the event by focusing on the blocking phenomena formed at Northeastern Asia. The area of cold weather is determined to represent the characteristic features of abnormal cold temperature. The 2010/11 winter is divided into three periods P1, P2 (cold period), and P3. For the cold area ($30-50^{\circ}N$, $115-135^{\circ}E$) the corresponding cold period P2 is determined to be 39 days from 23 December 2010 through 30 January 2011. During P1 and P3 temperature anomalies from the climatological mean are small with large standard deviation compared to those of P2, which has large negative anomaly and small standard deviation. The period P2 is dominated by blocking, which was determined by distributions of 500-hPa geopotential height and potential temperature on the 2 PVU surface. Correlation-coefficient analyses show that during P2 the temperature in the cold area is related with pressure of Northeastern Asia, while the temperature during P1 and P3 is related with pressure of Northwest of Korea. Also, during P1 and P3 the temperature pattern shows eastward propagation, but during P2, a stationary pattern. All the observations imply that, during the cold period P2, the temperature in the cold area is related with blocking in Northeastern Asia. During P1 and P3 temperature pattern is related with 500-hPa geopotential height in Siberia, and this relationship is also observed in the climatological mean state.

Design of Cold Extrusion Dies using Flexible Tolerance Method (플렉시블 허용오차법에 의한 냉간압출 금형설계)

  • Yeo H. T.;Choi Y.;Hur K. D.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.170-173
    • /
    • 2001
  • The design for cold extrusion dies is very important because the die insert is subjected to very high radial and hoop stresses. The design of cold extrusion dies has many constrained conditions. In this paper, two assumptions were proposed. First assumption was selected by yielding strength dependent on the to hoop stress of each ring in dies. Second assumption is that the maximum inner pressure is determined when yielding occurs in one ring of dies. To obtain the maximum inner pressure the flexible tolerance method was applied. A comparison of design values between the proposed method and the conventional method has been discussed.

  • PDF