A Study on Evaluation Analysis of Wind Formation Function using KLAM_21 -The Case of Daegu City- (KLAM_21을 활용한 바람생성기능 평가분석 연구 -대구시를 대상으로-)

  • Ryu, Ji-Won;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu;Son, Kyung-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.85-92
    • /
    • 2008
  • This study, the one concerning the evaluation analysis of the function of the wind generation using KLAM_21, has examined closely how the wind really flows on the space of the city, working with the object of case location. In the first place, the cold air formed at upper stream of Sincheon river, a ravine of whole area of Gachang gully and an inclined plane of neighboring mountainous district, flows to the north and expands itself along the upper stream of the Sincheon river, and as the time passes, it is tending upwards in the change of the volume and height as well as of the velocity and direction, of the cold air. It was learned that this phenomenon has made it clear that the spatial features of this area give rise to very good condition in generating and flowing the cold air. Meanwhile, it has been shown that in the area of park in the Ap-mountain, the generation and flow of the cold air are much interrupted because of the overpass traversing the whole area of the park of Ap-mountain, the congested area of large-scaled apartments and the urban development activities constructing the building in the park, and the volume and height of the cold air has been grown very small. In conclusion, It has been learned that for maximization of the spatial effect of the wind corridor, the areas where the cold air is generated, flowed, accumulated, and maintained, have to be connected spatially, and this spatial connection has a close relation with spatial features of the area.

  • PDF

Physicochemical Characteristics of Cold-Air Dried Persimmons and Traditional Dried Persimmons (냉풍건조 곶감과 천일건조 곶감의 이화학적 품질특성)

  • Lee, Su-Won;Moon, Hye-Kyung;Lee, Won-Young;Kim, Jong-Kuk
    • Food Science and Preservation
    • /
    • v.18 no.4
    • /
    • pp.481-487
    • /
    • 2011
  • This study was performed to investigate physicochemical properties of cold-air dried persimmon and traditional dried persimmons. Moisture contents and water activity were lower at cold-air dried persimmon than traditional persimmons. Crude protein and crude fat were not significant differences, Crude ash and N-free extracts of cold-air dried persimmon were, relatively, high as comparing to the traditional dried persimmons. Brix in cold-air dried persimmon was the highest. In the hunter's color values, L, a and b values of cold-air dried persimmon were lowed than traditional dried persimmons. There was not significant differences at the texture of semi-dried persimmons, but cold -air dried persimmon were relatively high than the traditional dried persimmons in hardness, gumminess, chewiness. Free sugars contents were only glucose and fructose in an sample. Free amino acids contents were seventeen sorts, glutamic acid and alanine were high in order of contents.

Optimal Design of Blowing Plates to Minimize the Freezing Phenomena in the Freezer of a Side-by-side Refrigerator (양문 여닫이형 냉장고 냉동실 결빙 최소화를 위한 토출구형상 최적설계)

  • Kwak, S.M.;Lee, Y.H.;Kum, J.S.;Kim, N.S.;Kim, S.B.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.17-22
    • /
    • 2003
  • As side-by-side refrigerators came into existence, there has been a growing concern about the free%ins-up of the vital equipment in a walk-in freezer. Due to a bad performance, customers are experiencing too much frustration. In order to minimize the freezing phenomena, the numerical simulation has been performed on the characteristics of cold air flow in a side-by-side refrigerator. The flow field has been simulated with a standard $k-\varepsilon$ turbulent model and a SIMPLE algorithm based on the finite volume method. Through the results of the analysis of the pattern of cold air flow, finally the shape of outlet for cold air flow was modified. The present model was compared with the modified model. The latter was better than the former in minimizing the freezing phenomena.

  • PDF

COMPARISON OF HYDROCARBON REDUCTION IN A Sl ENGINE BETWEEN CONTINUOUS AND SYNCHRONIZED SECONDARY AIR INJECTIONS

  • Chung, S.-H.;Sim, H.-S.
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • Effect of secondary air injection (SAI) on hydrocarbon reduction has been investigated in a single cylinder Sl engine operating at cold-steady/cold-start conditions. The hydrocarbon emission and exhaust gas temperature with and without catalytic converter were compared with continuous and synchronized SAIs, which injected secondary air intermittently into exhaust port. Effects of SAI location, SAI pressure, SAI timing, and location of catalytic converter have been investigated and the results are compared for both SAls with base condition. At cold-steady condition, the rate of HC reduction increased as the location of SAI was closer to the exhaust valve for both synchronized and continuous SAls. The emission of HC decreased with increasing exhaust-A/F when it was rich, and was relatively insensitive when it was lean. The timing of SAI in synchronized SAI had significant effect on HC reduction and exhaust gas temperature and the synchronized SAI was found to be more effective in HC reduction and exhaust gas temperature compared to the continuous SAI . At cold-start condition, when the catalytic converter was located 20 cm downstream from the exhaust port exit, the catalytic converter warm-up period for both SAls decreased by about 50%, and the accumulated hydrocarbon emission during the first 120 s decreased about by 56% and 22% with the synchronized and continuous SAIs, respectively, compared to that of the base condition.

A study on cooling characteristics of clathrate compound for cold storage applications (저온축열용 포접화합물에 냉각특성에 관한 실험적 연구)

  • 한영옥;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

An Experimental Study on Thermal Properties of Clathrate for Cold Storage Applications (저온축열용 포접화합물의 열물성에 관한 실험적 연구)

  • 한영옥;정낙규;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.725-734
    • /
    • 2000
  • The objective of this paper is to investigate the thermal properties of TMA clathrate applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are peformed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of concentrations and temperature of heat source in TMA clathrate. The results are summarized as follows; 1) temperature of phase change is dropped as the temperature of heat source is lower, 2) the effect of subcooling suppression with about $9.3^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 29wt% and 30wt% . Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$ Thus, it is concluded that TMA clathrate has proper properties as the cold storage medium for building air-conditioning.

  • PDF

Ventilation Rate Impact on Heating and Cooling Energy Consumption in Residential Buildings : Concentrated on a Detached House in Cold and Hot/Humid Climatic Zones of USA (환기량의 주거건물 냉난방에너지 소비에 대한 영향 : 미국 한랭기후 및 고온다습기후의 단독주택을 중심으로)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.747-753
    • /
    • 2011
  • The purpose of this study was to quantify the impact of the ventilation rate on heating and cooling energy consumption in a detached house. For it, a series of simulations for the application of the diverse ventilation rate (ACH) were computationally conducted for a prototypical detached residential building in the cold climate (Detroit, Michigan) and hot/humid climate (Miami, Florida) of USA. Analysis revealed that ventilation is a significant heat losing source in the cold climate; thus, the higher ventilation rate significantly increases the heating energy consumption and energy cost in the cold climate; while the impact on energy increase for heating and cooling energy consumption is similar in hot/humid climate with less significancy compared to cold climate. The research outcome of this study could be a fundamental data for determining the optimal ventilation rate in terms of indoor air quality, but also building energy performance well.

An Analysis of the Physiological and Psychological Responses Elicited When Wearing an Aerogel Cold Protective Jacket in Airflow (에어로젤 방한 재킷 착용시의 기류 유무에 따른 생리·심리학적 특성 분석)

  • Seong-Suk Kim;Su-Young Son;Hee-Eun Kim
    • Human Ecology Research
    • /
    • v.62 no.2
    • /
    • pp.317-326
    • /
    • 2024
  • This study evaluated the thermal physiological and psychological responses elicited when wearing cold protective jackets with aerogel fillings in two cold environments, one without air velocities and one with air velocities (2.3 m·s-1), at an air temperature of 10℃. The participants were five healthy young males. Measures were taken of physiological parameters, blood pressure (BP), heart rate (HR), core temperature, oxygen uptake (Vo2), and microclimate (temperature and humidity). The psychological parameters evaluated were thermal and wetness sensation. No differences were observed in systolic blood pressure, heart rate, and oxygen intake between the conditions. At tympanic temperature, a significant difference was observed between the conditions during exercise (p<.05); . A significant difference was observed in the microclimate temperature of the clothing according to the airflow, and temperature changes in the chest and back revealed different patterns. Significant differences were observed in thermal sensation (whole body (p<.05), chest (p<.05), back (p<.01)) between airflow conditions. The results therefore indicate that cold protective jackets with an aerogel filling are suitable for people operating in low-temperature and airflow environments.

A Comparison of the Cooling Effects for the Compressed Cold Air and Coolant on the Cylindrical Grinding with WA Wheel (WA 숫돌을 이용한 원통 연삭 시 압축냉각공기와 연삭유의 냉각효과에 관한 연구)

  • Lee, Seok-Woo;Choi, Hon-Zong;Jeong, Hae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.155-161
    • /
    • 2000
  • Recently, environmental pollution has become a big problem in industry and many researches have been done in order to preserve the environment. In the grinding process, the coolant has great influence on environment. It contains several chemicals(sulfur, phosphorus and chlorine) to improve the grinding efficiency. If these additives go into the workplace atmosphere, it is harmful for workers. It can also cause the environment pollution. Because of these reasons many studies have been done to minimize the amount of coolant. However the small amount of coolant can cause the thermal defect on the ground surface layer. This study forced the effects of the compressed cold air when the spindle shaft materials(SCM4 & SCM21) were cylindrical ground with WA wheel. The compressed cold air was used as the coolant and grinding performance was compared with that of the conventional grinding fluids(emulsion). Many experiments were carried out with these two cooling materials. The surface roughness, residual stress, and roundness were measured for the cylindrical grinding. The test results showed that the compressed cold air was very useful as the cooling materials for grinding process. It was also efficient to minimize the thermal defects of workpiece and could also play a role in solving environmental pollution.

  • PDF

Storage Characteristics of Rough Rice by Storage Method (저장방법에 따른 벼의 저장특성)

  • Lee, J.S.;Hong, H.K.;Kang, T.H.;Li, H.;Ham, T.M.;Kim, Y.H.;Han, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.3
    • /
    • pp.167-172
    • /
    • 2008
  • The objective of this study was to investigate the adequate storage method that was able to maintain the high quality of rough rice according to storage methods and period. The quality change of the rough rice during the storage period was evaluated by storage method such as cooling bin using winter cold air, ordinary temperature bin, freezing, refrigeration and indoor storage. Moisture content, brown rice whiteness, hardness, crack ratio and germination ratio were measured in this study. Moisture content of rough rice stored in cooling bin using winter cold air and ordinary temperature bin were decreased by 0.07% and 0.42%, respectively, which were lower than the other storage method. The hardness of brown rice increased in order of storage method such as winter cooling bin, normal bin, freezing storage, refrigeration storage and indoor storage. Crack ratio by indoor and ordinary temperature bin storage were increased by 2.68% and 3.63%, respectively, whereas cooling bin using winter cold air, refrigeration and freezing storage showed below 1.0%. The highest germination rate was found in cooling bin using winter cold air. As a result, cooling bin using winter cold air can be evaluated for the adequate storage method of rough rice.