• Title/Summary/Keyword: Cold stress test

Search Result 178, Processing Time 0.029 seconds

Cold stress test for the diagnosis of cold hypersensitivity on hands (냉부하검사를 통한 수부냉증의 진단)

  • Han, Ji-Young;Joe, Jung-Hoon;Jang, Jun-Bock;Kim, Yong-Suk;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • Purpose The cold hypersensitivity is a subjective symptom and it is very difficult to evaluate the severity. It is possible to detect cold hypersensitivity by measuring the skin temperature on DITI, but there is limitation only using DITI to find the objective grade of the symptom. To set a new objective standard for the diagnosis of cold hypersensitivity, we examined the relationship between the Visual Analogue Scale (VAS) score for the cold hypersensitivity and the change of skin temperature on hands by cold stress test Method 23 patients with symptom of cold hypersensitivity were participated as subjects who visited the women medical center of Kangnam Kyunghee Korean Hospital, Kyung Hee Univ. from May 1, 2002 to August 31, 2002. There were all carefully examined to rule out other disease such as obesity, skin diseases, spinal nerve lesions and external wounds. Thermographic observations for this study were made using DITI. We performed cold stress test three times to compare with the results from thermographic observations by DITI: first, after 15 minutes-resting, second, right after 1 minutes soak in $20^{\circ}C$ water, the third for last, 10 minutes after the soak. VAS score was chosen to determine the severity of cold hypersensitivity. Result 1 male and 22 female patients were participated ranging in age from 22.17 to 45.21. There was a significant negative correlation between the recovery rate of finger skin temperature after cold stress test and the VAS score. And there was a significant positive correlation between the difference of finger skin temperature and the back and palm of hands after cold stress test and the VAS score. Conclusion In cold hypersensitivity patients, the cold stress test combined with DITI could be a accurate method for the objective evaluation of cold hypersensitivity, especially good at deciding the severity by numeric values. Using a more strict criterion, as diagnosing of cold hypersensitivity, and longer follow-up may improve the validity of the results attained in clinical trials.

  • PDF

Effects of loading conditions and cold joint on service life against chloride ingress

  • Yang, Keun-Hyeok;Mun, Ju-Hyun;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Computers and Concrete
    • /
    • v.22 no.3
    • /
    • pp.319-326
    • /
    • 2018
  • RC (Reinforced Concrete) members are always subjected to loading conditions and have construction joints when constructed on a big scale. Service life for RC structure exposed to chloride attack is usually estimated through chloride diffusion test in sound concrete, however the test is performed without consideration of effect of loading and joint. In the present work, chloride diffusion coefficient is measured in concrete cured for 1 year. In order to evaluate the effect of applied load, cold joint, and mineral admixtures, OPC (Ordinary Portland Cement) and 40%-replaced GGBFS (Ground Granulated Blast Furnace Slag) concrete are prepared. The diffusion test is performed under loading conditions for concrete containing cold joint. Investigating the previous test results for 91 days-cured condition and the present work, changing diffusion coefficients with applied stress are normalized considering material type and cold joint. For evaluation of service life in RC continuous beam with 2 spans, non-linear analytical model is adopted, and service life in each location is evaluated considering the effects of applied stress, cold joint, and GGBFS. From the work, varying service life is simulated under various loading conditions, and the reduced results due to cold joint and tensile zone are quantitatively evaluated. The effect of various conditions on diffusion can provide more quantitative evaluation of chloride behavior and the related service life.

Vascular dysfunction in patients with type 2 diabetes mellitus

  • Ekta, Khandelwal;Mahaveer Jain;Sumeet Tripathi
    • Annals of Clinical Neurophysiology
    • /
    • v.25 no.1
    • /
    • pp.32-37
    • /
    • 2023
  • Background: Type 2 diabetic mellitus (T2DM) is an emerging global pandemic which is associated with lots of co-morbidities and reported vascular dysfunctions. T2DM associated vascular dysfunctions leads to vasculopathy in the form of altered peripheral vascular dynamics. Cold stress test (CST) is a reliable sympathetic reactivity test used for assessing vascular dysfunctions. In this study we are trying to quantify vascular dysfunctions in T2DM patients non invasively by various parameters of photoplethysmography (PPG) of cold stress test. Methods: Case control study had done in referral health center AIIMS, Raipur. Parameters are recorded by finger-PPG before, during and after CST (1 min) in 2 groups, control (n = 20 healthy volunteers) and case (n = 20 diagnosed T2DM patients). Results: Due to cold stress, PPG parameter peak amplitude was significantly decreased in both healthy and T2DM groups (p <0.001 and p <0.001, respectively). However, recovery trend of amplitude was significantly slow in T2DM compared to healthy subjects. Another PPG parameter peak to peak interval was significantly higher in healthy group compared to T2DM patients. Conclusions: This study showed that T2DM patients has significant deranged pulse volume parameters like amplitude and peak to peak interval can be used to objectively quantify the vasculopathy in T2DM patients by using sympathetic reactivity to cold stress.

Effect of far-infrared radiating products on cold hypersensitivity of lower limbs using Cold Stress Test (CST) : A pilot study (냉부하검사(CST)로 살펴 본 원적외선 기능성 제품이 족부냉증에 미치는 영향 : A pilot study)

  • Lee, Yoon-Jae;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.6 no.1
    • /
    • pp.69-75
    • /
    • 2008
  • Purpose: We investigated the effect of far-infrared radiating products on cold hypersensitivity of lower limbs using CST. Methods: 7 patients with cold hypersensitivity of lower limbs were investigated in this study. Exclusive criteria was skin diseases, spinal nervous disease and external wounds. They were asked to answer the VAS of cold hypersensitivity at baseline and after 3 weeks. We measured temperature of lower limbs with Spectrum 9000 MB (Dorex Inc, USA). We performed cold stress test (CST) by 3 thermographic observation using DITI : 1st was taken after 15 minutes resting at $25^{\circ}C$, the 2nd was immediately taken after 1 minute soak in $20^{\circ}C$ water, the 3rd was taken at 15 minutes after soak. We performed 3 times of CST : 1st CST was perfomed at baseline, 2nd CST was perfomred after 1 week and just observation, 3rd CST was performed after 1 week using far-infrared radiating products (lasner, UMT, Korea). Results: After using products, temperature of foot incresed more than thigh area, but there was no significance. There was no statistical difference of VAS, change of temperature and CST between before and after using far-infrared radiating products. Conclusion: There was no statistical effect of far-infrared radiating products on change of temperature of lower limbs.

  • PDF

Effects of Acupuncture on patients with cold hypersensitivity by Cold Stress Test : pilot study (냉부하검사(CST)를 활용한 수부냉증의 침치료 효과에 대한 예비 연구)

  • Hwang, Deok-Sang;Cho, Jung-Hoon;Lee, Chang-Hoon;Jang, Jun-Bock;Kim, Yong-Seok;Lee, Kyung-Sub;Lee, Yoon-Jae
    • Journal of Oriental Medical Thermology
    • /
    • v.5 no.1
    • /
    • pp.69-77
    • /
    • 2006
  • Purpose : There are many patients with cold hypersensitivity who want oriental medicine treatment. But there has been no study of acupucture treatment effect on patients. So we examined effects of acupuncture treatment at different acupuncture points and compared results of 1st cold stress test and 2nd cold stress test. Method : 8 patients with hand cold hypersensitivity applied for this study. To rule out an bias, we excluded the patients with skin diseases, spinal nerve disease of cervial spine, external wounds. We measured body temperature with D.I.T.I. We performed cold stress test(CST) by 6 thermographic observation using D.I.T.I ; the 1st was taken after 15 minutes-resting, the 2nd was immediately taken after 1 minute soak in $20^{\circ}C$ water, the 3rd was taken at 10 minutes after the soak, and after a week, the 4th was taken after 15 minutes resting, the 5th was immediately taken after 1 minute soak in $20^{\circ}C$ water, the 6th was taken after 10 minutes with acupunture treatment. There were two groups of patients. First group was acupuncture that performed acupuncture therapy on distal points. Second group was acupuncture that performed acupuncture therapy on proximal points. We compared first CST and second CST recovery rate result. Results : The recovery rate at distal points acupuncture therapy was higher than before of that. but not significantly different. The recovery rate at proximal points acupuncture therapy was significantly higher than before of that. The recovery rate of both the back, the palms, all fingers of after proximal acupuncture therapy was significantly higher than before of that. Conclusions : Acupuncture could be effective therapy method on cold hypersensitivity, especially using proximal acupuncture points could be good at cold hypersensitivity patients. This was pilot study of very small samples, results had limitations. For further results more examine would be needed.

  • PDF

A Study on the Method of Residual Stress Relaxation during Wire Drawing and Evaluation of Residual Stress Using Nano Indentation Test (신선 시 선재의 잔류응력 완화 방법에 관한 연구 및 나노 압입 시험을 이용한 잔류응력 평가)

  • Ko Dae-Cheol;Hwang Won-Ho;Lee Sang-Kon;Kim Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.162-169
    • /
    • 2006
  • Steel cord which is used as reinforcement in car tires is produced by wet-drawing process. Recently the quality improvement of the steel cord product is demanded by the tire market. After cold drawing process, produced residual stresses have a harmful effect on the durability of the wire and become the cause which decreases the quality of the product. Therefore, to improve the quality of the steel cord product, the research regarding the method of residual stress relaxation is necessary. To evaluate the quality of the cold drawn wire, it is very important to measure the residual stress, because the residual stress decides a variety of the quality level which is demanded in the cold drawn wire. The aim of this study is to propose residual stress relaxation method in the drawn wire using FE-analysis. The validity of the analysis results was verified by Nano indentation test.

A study on working limit of cold forging of carbon steel (냉간단조에 있어서 탄소강의 가공한계에 관한 연구)

  • Jae, Jin-Soo;Kang, Jong-Hun;Kang, Seong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1081-1088
    • /
    • 1997
  • The purpose of this work is to investigate the working limit of carbon steel and forging condition of cold forging. The fracture criteria which was proposed by Oyane and Osakada was used. Compression test, hardness study and tension test by Oyane's creteria, microstructure study by Osakada's were carried out. The results were compared with each other. It was found that working limit on compressive hydrostatic stress is increased in comparison with that of tensile stress field and can be forecasted the fracture limit of closed cold forging.

Identification of the genes which related cold (low temperature) stress in Bombyx mori

  • Kang, Min-Uk;Choi, Kwang-Ho;Park, Kwan-Ho;Nho, Si-Kab
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.33 no.2
    • /
    • pp.102-107
    • /
    • 2016
  • Stress may be defined as any modification of environmental parameters that leads to a response by biological organisms. Stresses that affect biolpgical structures may be nonthermal, such as ultraviolet radiation, pH, or salinity, or thermal. Temperture is one of the major stresses that all living organism face. The major effects of cold(low emperature) are decrease of membrane fluidity and the stabilization of secondary structures of RNA and DNA in the cells, which may effect the efficiency of translation, transcription, and DNA replication. In this study, we focus on discovering the genes that are expressed by the cold(low temperature) stress in the silkworm. In cold(low temperature) stress test, we found 100% survive from cold stress at $0^{\circ}C$ up to 12h and $-5^{\circ}C$ up to 2h, and then, survive rate was rapidly decrease in silkworm. Thereafter two whole genes have selected by SSH(Suppression subtractive hybridization). (GenBank accession : GQ149511, GQ338156)

Stress Corrosion Cracking Behavior of Cold Worked 316L Stainless Steel in Chloride Environment

  • Pak, Sung Joon;Ju, Heongkyu
    • Journal of Korea Foundry Society
    • /
    • v.40 no.5
    • /
    • pp.129-133
    • /
    • 2020
  • The outcomes of solution annealing and stress corrosion cracking in cold-worked 316L austenitic stainless steel have been studied using x-ray diffraction (XRD) and the slow strain rate test (SSRT) technique. The good compatibility with a high-temperature water environment allows 316L austenitic stainless steel to be widely adopted as an internal structural material in light water reactors. However, stress corrosion cracking (SCC) has recently been highlighted in the stainless steels used in commercial pressurized water reactor (PWR) plants. In this paper, SCC and inter granular cracking (IGC) are discussed on the basis of solution annealing in a chloride environment. It was found that the martensitic contents of cold-worked 316L stainless steel decreased as the solution annealing time was increased at a high temperature. Moreover, mode of SCC was closely related to use of a chloride environment. The results here provide evidence of the vital role of a chloride environment during the SCC of cold-worked 316L.

Effect of laser shock peening and cold expansion on fatigue performance of open hole samples

  • Rubio-Gonzalez, Carlos;Gomez-Rosas, G.;Ruiz, R.;Nait, M.;Amrouche, A.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.867-880
    • /
    • 2015
  • Mechanical fastening is still one of the main methods used for joining components. Different techniques have been applied to reduce the effect of stress concentration of notches like fastener holes. In this work we evaluate the feasibility of combining laser shock peening (LSP) and cold expansion to improve fatigue crack initiation and propagation of open hole specimens made of 6061-T6 aluminum alloy. LSP is a new and competitive technique for strengthening metals, and like cold expansion, induces a compressive residual stress field that improves fatigue, wear and corrosion resistance. For LSP treatment, a Q-switched Nd:YAG laser with infrared radiation was used. Residual stress distribution as a function of depth was determined by the contour method. Compact tension specimens with a hole at the notch tip were subjected to LSP process and cold expansion and then tested under cyclic loading with R=0.1 generating fatigue cracks on the hole surface. Fatigue crack initiation and growth is analyzed and associated with the residual stress distribution generated by both treatments. It is observed that both methods are complementary; cold expansion increases fatigue crack initiation life, while LSP reduces fatigue crack growth rate.