• Title/Summary/Keyword: Cold storage heat-exchanger

검색결과 15건 처리시간 0.027초

축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구 (Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제23권4호
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Design and Analysis of Heat Exchanger Using Sea Water Heat Source for Cooling

  • Kim, MyungRae;Lee, JuHee;Yoon, JaeOck
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.25-34
    • /
    • 2016
  • Purpose: The temperature in Seoul has risen 3 times more than the average global temperature increase for the past 100 years. Today, summer starts 15 days earlier than the early 20th century and is 32 days longer. This tendency causes rapid increase of cooling energy demand. Following this effect, seawater heat resources are to be used as an countermeasure for global warming. Incheon Port near the Western Sea has the lowest water temperature in the winter in South Korea in which it is suitable to use seawater cold heat resources. Method: The cold heat resource is gained from seawater when the water temperature is the lowest in the winter time and saved in a seasonal thermal storage. This can be used as cold heat resource in the summer time. A heat exchanger is essential to gain seawater cold energy. Due to this necessity, sea water heat resource heat exchangers are modeled by heat transfer equations and the fluid characteristics are analyzed. Also, a CFD (computational fluid dynamics) program is used to conduct simulation on the fluid characteristics of heat exchangers. The analyzed data of deducted from this process are comprehensively analyzed and discussed. Result: Regarding the performance of the heat exchanger, the heat exchanger was operated following the prediction within the range of heat transfer rate of minimum 3.3KW to maximum 33.6KW per device. In the temperature change analysis of the heat exchanger, fluid analysis by heat transfer equations almost corresponded to the temperature change by CFD simulation. Therefore, it is considered that the results of this study can be used as design data of heat exchangers.

공회전 제한장치 차량에서 냉방 성능 유지를 위한 축냉 시스템 적용에 대한 연구 (Feasibility Study of Cold Storage System to Maintaining Cooling Performance for ISG Vehicle)

  • 이대웅
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.7-14
    • /
    • 2016
  • This study explores the feasibility of a cold storage system to provide thermal comfort for idle stop and go (ISG) vehicles. ISG function is the most valuable and environmental friendly technology in the current automobile industry. However, when an ISG vehicle stops, meaning when the engine standstill, the air-conditioning system does not work, because the compressor also stops. Therefore, passenger thermal comfort is not maintained, as cold air is not provided in the cabin. Consequently, many automakers have studied electric air-conditioning systems based on electrically-driven compressors or cold storage systems using phase-change materials. The experiments herein were conducted for the feasibility testing of different types of cold storage heat-exchangers, cold storage mediums, and thermo-expansion valves with current air-conditioners. The auxiliary cold storage system, filled with phase-change materials, was located behind the evaporator and almost stacked on top of it. In the experimental results, the air discharge temperature rate of increase was better than the conventional air-conditioning system when the compressor stopped and thermal comfort was maintained with $1.9{\sim}4.3^{\circ}C$ decreases within 60 seconds. The #1 cold storage heat-exchanger (CSH), #2 thermo-expansion valve (TXV) and #2 phase change material (PCM) were chosen because of the best temperature rise delay. It was concluded that a cold storage system is an effective solution for ISG vehicles to maintain thermal comfort during short engine stops.

히트파이프와 용융염을 사용하는 태양열 축열조의 설계 (Design of a Solar Thermal Storage System Employing Heat Pipes and Molten Salts)

  • 이정륜;부준홍
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.86-91
    • /
    • 2011
  • Thermal design was conducted for a solar thermal storage system in a medium-temperature range between $200^{\circ}C$ and $400^{\circ}C$. The system was composed of heat pipes as heat carrier and molten salts as phase-change storage material. Each heat pipe penetrated through the storage system and had two heat-exchanging sections at both ends to interact with high-and low-temperature steams, while it exchanged heat with molten salts in the middle section. During a heat-storage mode, the heat pipes transferred heat from the hot steam at one side to the molten salts and it transferred heat from the molten salt to the cold steam at the other side during the heat-dissipating mode. A tube-bank type heat exchanger theory was applied to this design task to meet the required inlet and outlet temperatures of the steams depending on the operation modes. Several design variables were considered including the lengths of evaporator and condenser of a heat pipe, traverse and longitudinal pitches of the pipe, and the number of rows of the heat pipes for two different molten salt baths. An optimum design results were presented with discussion.

  • PDF

저 에너지형 축냉식 저온유통 시스템 개발 (Development of Cold Chain System Using Thermal Storage with Low-Energy Type)

  • 권기현;정진웅;김종훈;최창현
    • Journal of Biosystems Engineering
    • /
    • 제31권3호
    • /
    • pp.161-167
    • /
    • 2006
  • The purpose of this study is to find the optimal conditions of PCM slurry manufacturing equipment for saving the marketing cost and keeping the original quality of products. In addition, the characteristics of the movable container for shipping or distributing products is analysed. The major results are as follows. 1. PCM thermal storage system is designed with the conditions of temperature($-5{\sim}10^{\circ}C$), cold chain time(30 minutes), and one time usage(50 liter). This system includes tank, freezer, circulating pump, cycle type heat exchanger, swelling tank, equipment of supplying PCM supplying unit includes cold tank, cycle type heat exchanger, suction unit and control equipments, etc. 2. After ability test of PCM thermal storage system, it shows that the required freezing time of PCM thermal storage system is less than one of the previous system. The reason is that churn (top and bottom) and compulsion circulation are occurred simultaneously and unit cooler type method is better than chiller type method. 3. By the experiment of transportation latent heat container, it is decided that the best container is $K_1$ with latent heat temperature($0{\sim}5^{\circ}C$) and density(0.15%). However, for $K_l\;and\;K_2$, it is necessary more studies on latent heat thermal conditions and conditions of making method.

극저온 환경의 인쇄기판형 열교환기 열적성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of a Printed Circuit Heat Exchanger in a Cryogenic Environment)

  • 김동호;나상준;김영;최준석;윤석호
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.426-431
    • /
    • 2015
  • The advantages of a printed circuit heat exchanger (PCHE) are the compactness and efficiency derived from its heat-transfer characteristics; furthermore, a PCHE for which a diffusion bonding method was used during production can be applied to extreme environments such as a cryogenic condition. In this study, a micro-channel PCHE fabricated by diffusion bonding was investigated in a cryogenic environment regarding its thermal performance and the pressure drop. The test rig consists of an LN2 storage tank, vaporizers, heaters, and a cold box, whereby the vaporized cryogenic nitrogen flows in hot and cold streams. The overall heat-transfer coefficients were evaluated and compared with traditional correlations. Lastly, we suggested the modified heat-transfer correlations for a PCHE in a cryogenic condition.

시설원예용 수평형 지열 히트펌프 시스템의 성능분석 (Performance Analysis of the Horizontal Ground Source Heat Pump for Greenhouse)

  • 박용정;강신형
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.447-452
    • /
    • 2007
  • Greenhouses should be heated during nights and cold days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger(GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump ($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF

한국형발사체 3단 터빈배기부 개념설계 (Conceptual Design of Turbine Exhaust System for 3rd stage of Launch Vehicle)

  • 신동순;김경석;한상엽;방정석;김현웅;조동혁
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1068-1071
    • /
    • 2017
  • 3단 터빈배기부 구성은 터빈 플랜지, 열교환기, 배기덕트와 추력노즐로 이루어진다. 냉가스 가압 방식에 비하여 열교환기 가압 방식을 사용함으로서 추진제탱크 가압을 위한 헬륨가스 자체 무게와 저장 탱크 무게가 감소하는 장점이 있기 때문에 발사체에 열교환기를 사용한다. 가스발생기는 추진제 연료과농 조건에서 연소가 이루어지며, 연소가스 중에 그을음이 많이 포함되어 있기 때문에 열교환 효율이 감소하는 것을 고려하여 열교환기를 설계해야 한다. 본 논문에서는 터빈배기부 구성품 배치, 열교환기 내부 구조 및 제작성을 고려한 설계기법, 기 설계된 노즐 설계를 바탕으로 3단 터빈배기부 재 노즐 설계 형상에 대한 장점을 기술하였다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES) (A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage)

  • ;한정상;한혁상;한찬;김형수
    • 자원환경지질
    • /
    • 제38권6호
    • /
    • pp.717-729
    • /
    • 2005
  • 일반적으로 대규모 건물의 피크 냉방 부하는 난방부하보다 크다. 북위도의 한냉한 지역에 소재한 대규모건물의 냉난방 설비는 건물 내부에서 생성되는 발열량과 태양으로부터 획득되는 열량에 따라 좌우된다. 최대 냉방부하에 적합하도록 냉난방설비와 지중루프를 설치하는데 소요되는 비용은 일반적으로 초기투자비가 적게 드는 전통적인 HVAC시스템에 비해 다소 고가이다. 빙축열조(Thermal ice storage, TES)시스템은 과거 수년동안 일반 HVAC에서 냉동기의 용량을 축소시키거나 최대 전력부하 시간대를 바꾸기 위해 사용되어온 기술이다. 일반적으로 건물 난방을 위해서는 보일러와 같은 전통적인 난방설비를 이용하고 그 다음날의 건물냉방을 위해서는 전력료가 저렴한 야간에 빙축을 시키는 빙축열기법을 이용한다. 얼음에서 추출한 잠열 에너지의 장점을 이용하기 위해 설계된 분배시스템(distribution system)과 열원과 열배출원(열침, sink)대신에 지중열 교환기(지중루프)를 이용하면 많은 장점이 있다. 공간 난방과 급탕을 공급하기위한 분리형 설비를 별도로 사용하지 않아도 된다. 공간난방용으로 소요되는 설비용량을 축소시킬 수 있으며-소요 지중열 교환기의 규격과 비용을 절감시킴은 물론 지열 HVAC시스템의 효율을 배가 시킬 수 있으며 온실가스 배출량을 대폭 감축시킬 수 있다. 또한 TES를 적용하면 대규모 건물의 냉난방부하와 열펌프의 용량을 $40\~60\%$ 정도 감축시킬 수 있으며 설비대수와 기계실 공간을 줄일 수 있다. 뿐만아니라 피크 냉난방부하를 토대로 설계한 지원 열펌프 시스템(Ground source heat pump system)의 지중루프를 $1/4\~1/3$가지 줄일 수 있어 도심지역에서 지중루프를 설치할 때 장애요인인 지중루프 설치공간문제와 지중암석의 열적특성문제를 동시에 해결할 수 있다.문이며, 따라서 $^{137}Cs$의 분포는 광물분포 보다는 TOC의 함량에 더 큰 영향을 받고 있음을 보여준다.과 위기 고조 단계, 그리고 갈등 해소 단계등 모든 시기에서 두 신문의 주요 행위자 구성에 있어서 차이가 나타났다. 다시 말해, 조선일보는 기본적으로 총파업을 둘러싼 문제의 구성과 발전, 해소 과정에서 정당이나 대통령, 야당 지도자 등과 같은 정치관련 행위자를 강조하고 있었다. 반면에, 한겨레는 대체로 로든 사건진행 단계에서 노동 관련 단체들과 시민단체의 역동적인 연대와 활동에 초점을 맞추고 있는 것으로 나타났다.술 후 24시간에 599.4$\pm$145.6, 678.8 $\pm$256.4였다(t-test, p < 0.05). 동종 수혈은 RAP군에서 34명 중 7명에서(20.6$\%$), 대조군에서는 46명중 16명에서(34.8$\%$) 시행되어, RAP군에서 유의하게 빈도가 낮았다(Chi-square test, p < 0.05). 결론: 역행성 자가 충전법은 심폐바이패스의 충전에 의한 혈액희석을 최소화함으로서, 개심술 후 출혈과 동종수혈을 또한 줄이는 데 효과적인 방법이 될 수 있다고 생각된다.타내지 않았다.성 교사, 가정 전공 교사가 그렇지 않은 교사보다 해석적, 해방적 행동목표를 더 중요하게 인식하고 있었다. 특히 가정교육 철학을 배운 경험이 있는 교사가 그렇지 않은 교사보다 해방적 행동체계 목표를 중요시하는 것으로 나타났다. 이 연구 결과는, 실천 비판적인 가정 교과의 본질을 구현하기 위해서는 주생활 영역의 교육과정에 기술적, 해석적, 해방적 행동에 대한 목표들을 고루 포함하여야 하며 특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한