• Title/Summary/Keyword: Cold flow

Search Result 1,090, Processing Time 0.029 seconds

An Experimental Study on Thrust of Ground and High Altitude by Hydrogen Peroxide/Kerosene Engine (과산화수소-케로신 엔진을 이용한 지상 및 고고도 추력에 대한 실험적 연구)

  • Lee, Yang-Suk;Kim, Joong-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.100-106
    • /
    • 2019
  • Ground and high altitude simulated combustion experiments were conducted using a liquid rocket engine with hydrogen peroxide and kerosene as the propellant. A ground and high altitude simulated combustion test facility was constructed by installing a high altitude model diffuser and TMS (Thrust Measuring System) on a vertical combustion test bench. The thrust characteristics according to altitude were investigated using the combustion test equipment. The diffuser was designed on a 1:4.8 scale to verify the characteristics of the high diffusing diffuser and starting pressure. The cold flow tests were conducted using nitrogen gas, and the performance characteristics and starting characteristics of the scale down diffuser were verified. A diffuser and TMS were installed on the vertical combustion test bench, and the thrust correction equations for the system resistance were derived. The thrust correction equations were derived from the step test and vacuum step test before the actual hot firing test. Nozzles with an operating altitude of 10km were designed. Hot firing tests were conducted to analyze the thrust characteristics according to the operating altitude changes. The actual thrust was calculated using each correction equation with the thrust value measured by the TMS.

Analysis of Loss of Offsite Power Transient Using RELAP5/MODl/NSC; I: KNU1 Plant Transient Simulation (RELA5/MOD1/NSC를 이용한 원자력 1호기 외부전원상실사고해석 - I. 실제사고해석)

  • Kim, Hho-Jung;Chung, Bub-Dong;Lee, Young-Jin;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.97-106
    • /
    • 1986
  • System thermal-hydraulic parameters and simulated, using the best-estimate system code(RELAPS/MODl/NSC), based upon the sequence of events for the KNU1 (Korea Nuclear Unit 1) loss of offsite power transient at 77.5% power which occurred on June 9,1981. The results are compared with the actual plant transient data and show good agreements. After the flow coastdown following the trips of both reactor coolant pumps, the establishment of natural circulation by the temperature difference between the hot and the cold legs is confirmed. The calculated reactor coolant flowrate closely approximates the plant data indicating the validity of relevant thermal-hydraulic models in the RELAP5/MOD1/NSC. Results also show that the sufficient heat removal capability is secured by the appropriate supply of the auxiliary feedwater without the operation of S/G PORVs. In addition, a scenario accident at full power, based upon the same sequence of events described above, is also analysed and the results confirmed that the safety of KNU1 is secured by the appropriate operation of the S/G PORVs coupled with the supply of auxiliary feedwater which ensures sufficient heat removal capability. The characteristics of the non-safety related components such as the turbine stop valve closing time, S/G PORV settings etc. are recognized to be important in the transient analyses on a bestestimate basis.

  • PDF

The Study of the Integrated Technology of the Dual Fluidized-bed Gasification for Producing Medium Heating Value Syngas (중발열량 합성가스 생산을 위한 일체형 이중유동층 가스화 기술 연구)

  • Choi, Jae-Myeong;Kim, Jae-Min;Kim, Sung-Hyun;Son, Yang-Seung;Lee, Dong-Min;Choi, Jin-Hoon;Park, Sung-Youl;Kim, Seong-Soo
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A 5 kg/hr scale integral dual fluidized-bed gasifier for producing medium heating value syngas from biomass or combustible wastes was manufactured. The effect of operating variables including gasification temperature, rate of feeding, and weight ratio of steam/feed on the behavior of the gasifier was investigated. The contents of $H_2$ and CO in syngas, flow rate of feeding, cold gas efficiency increased with the increased gasification temperature or rate of feeding, but decreased with the increased weight ratio of steam/feed within the experimental range. With wood powder as the feed, the concentrations of $H_2$ and CO in the syngas were as high as 41% and 32%, and the cold gas efficiency and lower heating value of the syngas were as high as 70.1% and $3,428kcal/Nm^3$. With food wastes as the feed, the concentrations of $H_2$ and CO in the syngas were as high as 37% and 23.9%, and the cold gas efficiency and lower heating value of the syngas were as high as 66.7% and $3,670kcal/Nm^3$.

Modification of Sea Water Temperature by Wind Driven Current in the Mountainous Coastal Sea

  • Choi, Hyo;Kim, Jin-Yun
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.177-184
    • /
    • 2003
  • Numerical simulation on marine wind and sea surface elevation was carried out using both three-dimensional hydrostatic and non-hydrostatic models and a simple oceanic model from 0900 LST, August 13 to 0900 LST, August 15, 1995. As daytime easterly meso-scale sea-breeze from the eastern sea penetrates Kangnung city in the center part as basin and goes up along the slope of Mt. Taegullyang in the west, it confronts synoptic-scale westerly wind blowing over the top of the mountain at the mid of the eastern slope and then the resultant wind produces an upper level westerly return flow toward the East Sea. In a narrow band of weak surface wind within 10km of the coastal sea, wind stress is generally small, less than l${\times}$10E-2 Pa and it reaches 2 ${\times}$ 10E-2 Pa to the 35 km. Positive wind stress curl of 15 $\times$ 10E-5Pa $m^{-1}$ still exists in the same band and corresponds to the ascent of 70 em from the sea level. This is due to the generation of northerly wind driven current with a speed of 11 m $S^{-1}$ along the coast under the influence of south-easterly wind and makes an intrusion of warm waters from the southern sea into the northern coast, such as the East Korea Warm Current. On the other hand, even if nighttime downslope windstorm of 14m/s associated with both mountain wind and land-breeze produces the development of internal gravity waves with a hydraulic jump motion of air near the coastal inland surface, the surface wind in the coastal sea is relatively moderate south-westerly wind, resulting in moderate wind stress. Negative wind stress curl in the coast causes the subsidence of the sea surface of 15 em along the coast and south-westerly coastal surface wind drives alongshore south-easterly wind driven current, opposite to the daytime one. Then, it causes the intrusion of cold waters like the North Korea Cold Current in the northern coastal sea into the narrow band of the southern coastal sea. However, the band of positive wind stress curl at the distance of 30km away from the coast toward further offshore area can also cause the uprising of sea waters and the intrusion of warm waters from the southern sea toward the northern sea (northerly wind driven current), resulting in a counter-clockwise wind driven current. These clockwise and counter-clockwise currents much induce the formation of low clouds containing fog and drizzle in the coastal region.

  • PDF

The study of Literature Review on the pathological mechanism and Therapeutic methods of sudden coma -Focused on Different opinion of successive dynastic medical group in HwangJeNaeKyung and SangHanRon- (궐증(厥證)의 병인병기(病因病機) 및 치방(治方)에 관한 문헌적(文獻的) 고찰(考察) -내경(內經)과 상한론(傷寒論)에 대(對)한 역대의가(歷代醫家)의 견해(見解) 차이(差異)를 중심(中心)으로-)

  • Ryu Hyung-Cheon;Kwack Jeong-Jin;Choi Chang-Won;Lee Gang-Nyoung;Lee Young-Soo;Kim Hee-Chul
    • Herbal Formula Science
    • /
    • v.11 no.1
    • /
    • pp.57-90
    • /
    • 2003
  • The result of Bibliographic studies on the pathological mechanism of the sudden coma, we got the conclusion like this. 1. The sudden coma is an acute syndrome that refers to be a sudden fainting, an unconsciousness, an aphasia or a cold clammy limb, and immediately awakes or dies, and awakes in a short time, and if we awake, it doesn't leave over and above a sequela. 2. The clinical presentation of the sudden coma can be summarized as follows : The 1st is a disease raising the sudden death due to unconsciousness accompanied by wry mouth & sudden syncope with coma. The 2nd is simply the state of cold limbs. The 3rd is the meaning of the physique and symptomes of the six meridians. The last is the ancient method of expression in contrast of the beriberi. 3. The pathological mechanism of the sudden coma consists of the toxoid from outside, Qi and Xie, fatigue, damp phegm, the damage from seven emotions and the damage from five mental elements, especially the mental disorder due to the angry energy, causes the problems when the fleming-up of liver fire and the depressed of liver qi raise the physiological disorder. 4. Therapeutic methods of sudden coma are soothing the liver and remove stasis, soothing depression and circulating of the qi, calming the liver and suppressing yang. When that is early stage, at first, we must checking upward adverse flow of the qi after promoting the circulation of qi and awakening, and then, we must regulate excessive deficiency of yin yang by therapy that is based on differentiated in symptoms according to heat & cold, deficiency & excess, and use invigorating herb medicine for supporting vigour.

  • PDF

A Study on Properties of Retarder via Tabletting Method (정제화 방법을 이용한 응결 지연제의 특성에 관한 연구)

  • Ryou, Jae-Suk;Yang, Neung-Won;Lee, Yong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.201-207
    • /
    • 2013
  • When hot weather concrete is utilized, the cooling methods of cooling pipe, liquid nitrogen, ice, etc., are used to prevent the poor consistency and cold joint due to high temperature. These methods, however, spike the production cost and energy consumption, and make quality control difficult. Among these methods is one that involves the use of a retarder. Although economical, retarder is caused difficulty of retarded hardening and setting time control due to inaccurate weighing and poor working condition. Therefore, how to make a tablet for hot weather concrete, as with the existing pharmacy and foods, is discussed in this study, including the following items: mortar setting time, flow test by elapsed time, physical and mechanical properties of concrete. As a result, gluconic acid is superior to lignosulfonic acid and the possibility of using them for such purpose without quality degradation was confirmed in this study, when retarder is tabletting.

Distribution Status and Extinction Threat Evaluation of Ladislabia taczanowskii (Cypriniformes, Cyprinidae), a Cold Water Fish in Korea (한국산 냉수성 어류 새미(잉어목, 잉어과)의 분포현황 및 멸종위협평가)

  • Choi, Kwang-Seek;Bae, Yang-Seop;Ko, Myeong-Hun
    • Korean Journal of Ichthyology
    • /
    • v.34 no.1
    • /
    • pp.34-43
    • /
    • 2022
  • A distribution survey was conducted from March to August 2021 to evaluate the distribution status, habitat characteristics, and threat of extinction of the Korean cold-water fish Ladislabia taczanowskii Dybowski (Cypriniformes, Cyprinidae). Historical distribution reports were divided into 1997~2005, 2006~2012, 2013~2019, and distribution surveyed 169 sampling sites, and 1,040 individuals were collected from 72 sites. Areas where the habitat was confirmed were Namhan River (27 stations), Han River (17 stations), Bukhan River (16 stations), Samcheok Osipcheon (4 stations), Yeongokcheon (3 stations), Gangneung Namdaecheon (2 stations), Jeoncheon (1 station), Chucheon (2 stations). The main habitat of L. taczanowskii was upstream of the river with a high altitude of more than 300 m, 2~30 m water flow width, 0.3~1.5 m water depth, and high ratio (50~90%) boulder bottoms. The main reasons for the decline in population size were assumed as river works, construction of reservoirs and bridges, discharge of contaminated water into the river, the inflow of summer vacationers, and weir. Compared to our results there exists evidence that states a 36.1% reduction in occupancy within 10 years, in a small appearance range (7,820 km2) and occupancy area (288 km2), number of disconnected locations (19 locations), and a decline in habitat quality. Therefore, L. taczanowskii is now considered as Vulnerable (VU) based on the results (VU A2ac, Near meets B1b (i, ii, iii)+B2b (i, ii, iii)) of IUCN Red List categories and criteria. Lastly, the conservation plan of Ladislabia taczanowskii was discussed.

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

Design and Economic Analysis of Low Pressure Liquid Air Production Process using LNG cold energy (LNG 냉열을 활용한 저압 액화 공기 생산 공정 설계 및 경제성 평가)

  • Mun, Haneul;Jung, Geonho;Lee, Inkyu
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.345-358
    • /
    • 2021
  • This study focuses on the development of the liquid air production process that uses LNG (liquefied natural gas) cold energy which usually wasted during the regasification stage. The liquid air can be transported to the LNG exporter, and it can be utilized as the cold source to replace certain amount of refrigerant for the natural gas liquefaction. Therefore, the condition of the liquid air has to satisfy the available pressure of LNG storage tank. To satisfy pressure constraint of the membrane type LNG tank, proposed process is designed to produce liquid air at 1.3bar. In proposed process, the air is precooled by heat exchange with LNG and subcooled by nitrogen refrigeration cycle. When the amount of transported liquid air is as large as the capacity of the LNG carrier, it could be economical in terms of the transportation cost. In addition, larger liquid air can give more cold energy that can be used in natural gas liquefaction plant. To analyze the effect of the liquid air production amount, under the same LNG supply condition, the proposed process is simulated under 3 different air flow rate: 0.50 kg/s, 0.75 kg/s, 1.00 kg/s, correspond to Case1, Case2, and Case3, respectively. Each case was analyzed thermodynamically and economically. It shows a tendency that the more liquid air production, the more energy demanded per same mass of product as Case3 is 0.18kWh higher than Base case. In consequence the production cost per 1 kg liquid air in Case3 was $0.0172 higher. However, as liquid air production increases, the transportation cost per 1 kg liquid air has reduced by $0.0395. In terms of overall cost, Case 3 confirmed that liquid air can be produced and transported with $0.0223 less per kilogram than Base case.

Study of Thermoelectric Generator with Various Thermal Conditions for Exhaust Gas from Internal Combustion Engine using Numerical Analysis (수치해석을 통한 엔진 배기가스의 조건 변화에 따른 열전소자 발전 특성에 관한 연구)

  • In, Byung Deok;Lee, Ki Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.243-248
    • /
    • 2013
  • Internal combustion engines typically expel 30%-40% of the energy supplied by fuel to the environment through their exhaust system. Therefore, further significant improvements in the thermal efficiency of IC engines are possible by recovering the waste heat from the engine exhaust gas. With this fact in mind, a numerical simulation was carried out to investigate the potential of using thermoelectric generation with an internal combustion engine for waste heat recovery. Physical parameters such as the exhaust temperature and mass flow rate were evaluated in the exhaust system, and the optimum location for inserting a thermoelectric generator (TEG) into the system was determined. The TEG will be located in the exhaust system and will use the energy flow between the warmer exhaust gas and the external environment. The optimum position of the temperature distribution and the TEG performance were predicted through numerical analysis. The experimental results obtained showed that the power output significantly increases with the temperature difference between the cold and hot sides of the TEG.