• Title/Summary/Keyword: Cold Chamber

Search Result 278, Processing Time 0.026 seconds

CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber (덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD)

  • Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2021
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. A curved constant temperature chamber was constructed that can be tested under the same conditions as in the natural state so that the research can be conducted in which frost does not occur on the outdoor unit of the heat pump regardless of the season. Simulations were performed to verity whether such a curved constant temperature chamber has feasibility as an experimental device. For CFD conditions, the length of the straight duct in front of the outdoor unit located in the duct-type constant temperature chamber was 1, 5, 10 and 15 times the diameter of the duct. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Translational Study for "Treatise on Bundon Disease in Chapter 8 of the Essence of the Synopsis of the Golden Chamber" ("금궤요략심전.분돈기병맥증치제팔(奔豚氣病脈證治第八)"에 대한 번역연구)

  • Li, Xian-Lan;Lee, Yong-Bum
    • Journal of Korean Medical classics
    • /
    • v.21 no.2
    • /
    • pp.21-28
    • /
    • 2008
  • After translating the contents of "Treatise on Bundon Disease in Chapter 8 of the Essence of the Synopsis of the Golden Chamber" and it was compared with the contents of "The Lecture of Synopsis of Prescriptions of the Golden Chamber" and speculated to review the characteristics of the comments of Ui(尤怡) and the following conclusions were made. As the causes of bundon(奔豚) disease, which means gas rushing like a running piggy from the lower abdomen to the throat, they could be categorized into the cases belongs to miscellaneous diseases (雜病) and into the cases of suffering from cold diseases(傷寒). If it was diagnosed as miscellaneous disease, terror and fear(驚恐) could be regarded as its cause and if it was diagnosed as cold disease, insufficiency of heart Gi(心氣) due to the excessive sweating and the invasion of exterior coldness could be regarded as its cause. As the pathogenesis of this disease, the pathogenic factors of liver and kidney could be found. Since the liver and Soyang meridian(少陽經) are subjected to the exterior and interior relation in case of the pathogenic factor of liver, alternate attacks of chills and fever(寒熱往來) could be characteristic for the disease. If this disease was caused by the pathogenic factor of kidney, there are two cases. One is the palpitation under the umbilicus(欲作奔豚: 臍下動悸) developed by the lack of heart Gi(心氣) and the other is gas rushing like a running piggy from the lower abdomen to the throat which could be developed by the exterior cold disease which invade into the interior and reach into the kidney when the heart Gi(心氣) was insufficient. In its treatment, bundon disease caused by the pathogenic factor of liver could be treated with Bundontang(奔豚湯), and the understanding of Ui(尤怡) on Pinellia ternata Breitenbach(半夏) having the effect of perspiration in the prescription is quite unique concept. In case of bundon disease caused by the pathogenic factor of kidney, treatment is focused to treat exterior coldness by applying moxibustion(灸) and Gyejigagyetang(桂技加桂湯), and in case of the palpitation under the umbilicus(欲作奔豚: 臍下動悸), its pathogenic factor of kidney is controlled with Cinnamomum louerii Nees(桂技), Polia cocos Walf and the spleen Gi(脾氣) is cared by using Glycyrrhiza uralensis Fischer et. De Candolle(甘草) and Zizyphus jujuba Mill(大棗). Especially, Ui(尤怡) emphasized Cinnamomum louerii Nees(桂技) as the medication to treat the pathogenic factor of kidney.

  • PDF

Effects of Sub-freezing Systems on the Freshness of Pork Loin, Beef Loin and Tuna (냉각방식에 따른 반냉동 돼지고기, 쇠고기와 참치의 신선도 변화)

  • Kim, Don;Chang, Young-Ki;Park, Ki-Hwan;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.341-348
    • /
    • 2000
  • Effects of different types of sub-freezing methods on quality of raw pork loin, beef loin and tuna were studied. Storage tests were undertaken as follows; the three different types of sub-freezing methods, such as regular cold chamber at $-1^{\circ}C$, air-blast sub-freezing at $-5^{\circ}C$ and sharp-plate sub-freezing at $-5^{\circ}C$, were evaluated for extending freshness of samples. Pork loin packed with polyethylene-film showed no significant differences (P<0.05) in physico-chemical properties among the above sub-freezing methods. Air-blast sub-freezing methods revealed faster evaporation of moisture from samples. The same sub-freezing method also showed increased VBN values of pork loin and tuna samples. Regular cold chamber resulted in increased TBA values and K values of beef loin and tuna, respectively. It appeared that sharp-plate freezing system kept the food samples with the least loss of freshness among the above three sub-freezing methods. These results indicated that freshness of raw pork, beef and tuna could be significantly extended by the sharp-plate sub-freezing method.

  • PDF

Mercury Exchange Flux from Two Different Soil Types and Affecting Parameters

  • Park, Sang-Young;Kim, Pyung-Rea;Han, Young-Ji
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.4
    • /
    • pp.199-208
    • /
    • 2013
  • Mercury exchange fluxes between atmosphere and soil surface were measured in two different types of soils; lawn soil (LS) and forest soil (FS). Average Hg emission from LS was higher than from FS although the soil Hg content was more than 2 times higher in forest soil. In LS, Hg emissions were much greater in warm season than in cold season; however, deposition was dominant in FS during warm season because of leafy trees blocking the solar radiation reaching on the soil surface. In both LS and FS, Hg fluxes showed significantly positive correlations with UV radiation and soil surface temperature during cold season. In addition, it was observed that emission showed positive correlation with UV radiation and soil temperature while there was negative relationship between deposition and UV radiation.

Short-Term Cold Exposure May Cause a Local Decrease of Neuropeptide Y in the Rat Hypothalamus

  • Park, Joong Jean;Lee, Heung Kyung;Shin, Min Woo;Kim, Sung Jin;Noh, Seung Yeon;Shin, Jin;Yu, Woo Sung
    • Molecules and Cells
    • /
    • v.23 no.1
    • /
    • pp.88-93
    • /
    • 2007
  • Neuropeptide Y (NPY) is an orexigenic and hypothermic peptide. To understand its role in hypothermic conditions, male rats were placed in a $24^{\circ}C$ or $4^{\circ}C$ air chamber for 1.5 h. The expression of c-Fos protein, and NPY mRNA and protein, was analyzed in the hypothalamus 1 h-2 h later. The cold treatment increased the number of c-Fos-immunoreactive cells in the paraventricular hypothalamic nucleus (PVN) and arcuate nucleus (ARC). At the same time it decreased the density of NPY-immunoreactive components in the PVN, dorsomedial hypothalamic nucleus and ARC, as well as of NPY transcripts in the PVN and ARC. No colocalization of c-Fos with NPY was detected. These results suggest that short-term cold exposure should reduce indirectly NPY production in some hypothalamic nuclei to facilitate thermogenesis without inducing feeding behavior.

A Study on the Anti-lcing Performance Evaluation and Design Guide for Weather-Tight Door of the Vessels Operating in Cold Region (빙해선박 풍우밀문의 결빙방지 성능평가 및 설계기준에 관한 연구)

  • Seo, Young-Kyo;Jung, Young-Jun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.6
    • /
    • pp.450-457
    • /
    • 2013
  • For the design guide of a vessel operating in cold region, numerical analysis was carried out to evaluate the weather-tight door which installed the heating cables by using ANSYS 13.0 Transient Thermal. The numerical analysis was performed by considering Advection-Diffusion equation. This study based on the experimental results of 'A study on Anti-Icing Technique for Weather-Tight Door of Ice-Strengthened Vessels'(Jeong, et al., 2011a) in KIOST. For validation of the numerical analysis results, the cold chamber experimental data measured by the heat sensors in certain location of the weather-tight door was used. The external environmental temperature which varies from $5^{\circ}C$ to $-55^{\circ}C$ was considered in numerical analysis. Also three different heating cables which have the heat capacity of 33W/m, 45W/m and 66W/m were adapted for the design parameters to be the most efficient and guidelines for anti-icing design of the weather tight door.

Thermophysiological Responses of the 60's Male and Female in Hot and Cold Environment (여름, 겨울 환경에 따른 60대 남녀의 온열 생리적 특성연구)

  • Lee, Jung-Sug;Kim, Hee-Eun;Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.668-675
    • /
    • 2008
  • The purpose of this study was to collect data of skin temperature and physiological responses which is useful for standardization of insulation measurement in various garments. And we investigated sex and season difference of physiological responses of 60's males and 60's females in hot and cold environment. Healthy ten 60's males and ten 60's females volunteered as subjects. The experiment was conducted three times; One for winter condition($5^{\circ}C$, 45%), another for summer condition($30^{\circ}C$, 65%) and the other for nude condition as control($30^{\circ}C$, 65%). The subjects were sitting for 1 hour with suitable ensemble on each experimental condition in climate chamber. We measured skin temperature, rectal temperature, heart rate, oxygen uptake, sweat rate, blood flow, blood pressure and subjective sensations. We found that skin temperature and most of physiological responses were higher in male subject, summer condition than in female subject, winter condition.

An Experimental Study of Supersonic Underexpanded Jet Impinging on a Perpendicular Flat Plate (평판 위에 충돌하는 초음속 과소팽창 제트에 관한 실험적 연구)

  • 이택상;신완순;이정민;박종호;김윤곤
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.53-61
    • /
    • 1999
  • Impinging jets are observed when exhaust gases from missiles or V/STOL aircrafts impinge on the ground, flame deflector, ship deck, etc. The flow shows different patterns according to the nozzle geometry, nozzle-to-plate distance, and plate angle, for example. This paper describes experimental works on the phenomena (pressure distribution, occurrence of stagnation bubble, and so on.) when underexpanded supersonic jets impinge on a perpendicular flat plate using a supersonic cold-flow system, and compares the results with those obtained using a shock tunnel. The flow characteristics for the supersonic cold-flow system were also investigated. Surface pressure distribution of supersonic cold-flow system differed from that of shock tunnel because of water and temperature in the low-pressure chamber. Surface pressure distribution as to underexpanded ratio showed similar patterns together.

  • PDF

A Study on the De-Icing Performance Evaluation and Design Guide for Ice Class Louver of the Vessels Operating in Cold Region (빙해선박 아이스 클래스 루버의 해빙(de-icing) 성능평가 및 설계기준에 관한 연구)

  • Jung, Young-Jun;Seo, Young-Kyo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.4
    • /
    • pp.323-329
    • /
    • 2015
  • For the design guide of a vessel operating in cold region, numerical analysis was carried out to evaluate the ice class louver which installed the heating cables by using ANSYS 13.0 CFX. The numerical analysis was performed by considering Unsteady Reynolds Averaged Navier Stokes (RANS) equation. This study based on the experimental results of ‘The Cryogenic Performance Evaluation for the Excellent De-icing Ice Class Louver’ in KRISO. For validation of the numerical analysis results, the cold chamber experimental data measured by the heat sensors in certain location of the ice class louver was used. The external environmental temperature which varies from 0℃ to –30℃ was considered in numerical analysis. Also the design guide for optimum de-icing presented through heating cable power capacity(33 W/m, 45 W/m, 66 W/m), location of the heating cable(front, center, behind on the blade) and relative velocity(1 m/s, 4 m/s, 7 m/s).

A PARAMETRIC STUDY OF CONICAL FRUSTUM GEOMETRY FOR IMPROVEMENT OF COOLING PERFORMANCE OF VORTEX TUBE (Vortex Tube 성능 개선을 위한 절두체의 형상 매개변수에 대한 연구)

  • Koo, H.B.;Park, J.Y.;Sohn, D.Y.;Choi, Y.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.7-13
    • /
    • 2015
  • Vortex tube is a thermal static device that separates compressed air into hot and cold streams. In general, the cooling efficiency of vortex tubes is lower than that of traditional air conditioning equipment and vortex tubes are mainly used for industrial spot cooling applications because of their quick responses. In this study, conical frustums are employed in the nozzle chamber to improve the cooling performance. Conical frustums can be used to decrease the ineffective mass fraction that directly passes through the cold exit without energy separation. The shape optimization of conical frustums has been performed using full factorial design. It is found that the height of frustums has the largest main effects on the cooling performance. Computational results show that the cooling performance can be increased by about 10% within the considered range of the design parameters. This is because the ineffective mass fraction toward the cold exit is decreased by about 20%.