• 제목/요약/키워드: Cold Air Generation and Flow

검색결과 22건 처리시간 0.022초

냉장고 내부의 냉기 유동특성에 관한 3차원 해석(I) (3-Dimensional Calculation on Cold Air Flow Characteristics in a Refrigerator)

  • 오민정;이재헌;오명도
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.382-395
    • /
    • 1995
  • A numerical study has been performed on flow characteristics in a domestic refrigerator whose size is $540mm{\times}1,530mm{\times}680mm$, considering existence of a fan and evaporator. The flow field has been simulated with the low Reynolds number $k-\bar{\varepsilon}$ turbulent model and SIMPLE algorithm based on the finite volume method. The region of fan which makes driving force for cold air distribution was modeled as a region in which momentum sources are generated uniformly. The concept of the distributed pressure resistance was applied to describe the momentum loss from evaporator. The result showed that the rate of cold air distribution into freezing room and cold storage room was almost 7 : 3.

  • PDF

대구시 열대야 대응 구역 설정을 위한 야간 찬공기 유동성 분석 (Analysis of Nocturnal Cold Air Flow Characteristics for Setting of Tropical Night Response Zone in Daegu)

  • 서보용;이상범;권순범;차재규;정응호
    • 한국지리정보학회지
    • /
    • 제23권3호
    • /
    • pp.220-235
    • /
    • 2020
  • 도시에서의 폭염발생은 기본적으로 지구온난화에 영향을 받으나, 도시에서 발생하는 인공열 배출과 열축적이 큰 토지피복의 영향으로 더욱 가중된다. 특히 도시폭염의 영향은 야간 열대야 발생에도 직접적 영향을 준다. 그러나 기본적으로 주간의 폭염대응에 비해 열대야 대응수단 선택은 매우 제한적이다. 본 연구에서는 대구시를 대상으로 열대야 대응 방안으로 야간 찬공기 유동 특성을 분석하고 이의 공간적 활용가능성을 제시하고자 하였다. 연구방법은 찬공기 유동 분석 프로그램인 KLAM_21을 활용하여 대구시의 찬공기 유동의 공간적 특성인 찬공기 높이 및 유동범위와 유속 및 유동방향을 정량적으로 분석하였다. 분석결과 대구시 주변산지에서의 찬공기 생성, 유동은 매우 활발하나 열대야 발생지역인 도심지역으로 유입이 제한적인 것으로 나타났다. 그러나 일부 시가지에서는 주변산지로부터 유입되는 찬공기 유동성이 매우 활발하여 열대야 대응에 매우 효과적인 공간적 조건을 가지고 있는 것으로 나타났다. 이러한 공간적 조건을 도시계획적 차원에서 활용하면 열대야 대응방안 개발에 매우 유용할 것으로 판단된다.

바람길 활용을 위한 정맥의 찬공기 관리 방안 - 낙남정맥을 사례로 - (Management Strategies of Local Cold Air in Jeongmaek for utilizing urban Ventilation Corridor - A Case Study of the Nak-nam Jeongmaek -)

  • 엄정희
    • 한국지리정보학회지
    • /
    • 제22권1호
    • /
    • pp.154-167
    • /
    • 2019
  • 기후변화에 따른 각종 환경문제가 발생하는 가운데, 도시에서는 폭염, 열대야와 같은 도시 열환경 문제가 심각해지고 있다. 한국은 찬공기 생성에 유리한 산림지역이 국토면적의 약 63%을 차지하고 있으며, 주요 산줄기인 정맥은 도시지역과 밀접하게 위치해 있기 때문에 찬공기를 활용하는 것은 도시 열환경 완화에 매우 효과적인 방안이 될 수 있다. 본 연구에서는 낙남정맥을 대상으로 정맥에 위치한 도시들의 바람길 활용 방안을 마련하기 위해 정맥의 찬공기 특성을 알아보고, 이를 바탕으로 낙남정맥의 찬공기 관리방안을 제안하였다. 또한, 낙남정맥에 위치한 진주시와 산청군을 대상으로 상세분석을 수행하여, 정맥에서 생성된 찬공기 흐름이 인근 도시 지역에 미치는 영향을 분석하고 이를 바탕으로 도시지역에서 찬공기를 활용하기 위한 관리방안을 제시하였다. 찬공기 특성 분석을 위해 독일에서 개발된 모형인 KALM(Kaltluftabflussmodell)을 활용하였으며, 야간 6시간 동안 생성되는 찬공기 흐름 및 찬공기층 높이를 파악하였다. 분석 결과, 시간이 경과함에 따라 정맥에서 생성된 찬공기 흐름이 뚜렷해지고, 찬공기층의 높이는 증가하였다. 찬공기 분석 결과를 바탕으로, 찬공기 흐름을 유지 및 확대할 수 있는 관리방안을 제안하였다. 예를 들어, 찬공기 생성이 활발한 산림지역 일대를 '찬공기 보전지역'으로 지정하고, 원활한 찬공기 흐름을 위해 관리가 필요한 지역을 '찬공기 관리지역'으로 지정하여 전략을 제시하였다. 본 연구의 결과는 낙남정맥에 위치한 도시지역의 쾌적한 열환경 조성을 위한 바람길 활용방안의 일환으로 낙남정맥의 체계적인 관리계획을 수립하는데 기초자료로 활용될 수 있을 것으로 기대한다.

전주지역의 바람길 특성 분석 및 활용 방안 (Analysis and Utilization Strategies of Ventilation Corridor Characteristics in Jeon-ju Area)

  • 엄정희
    • 한국환경생태학회지
    • /
    • 제33권3호
    • /
    • pp.366-374
    • /
    • 2019
  • 본 연구는 폭염 및 미세먼지 저감을 위한 계획요소인 바람길의 활용 가능성을 논의해보고자, 전주시를 대상으로 바람길의 특성을 분석하고, 바람길 활용을 위한 방안을 제안하는 것을 목적으로 한다. 이를 위해, 호남정맥에 위치하는 전주지역 일대의 찬공기 흐름 및 찬공기 층 높이 등 찬공기 특성을 분석하였고, 전주시의 주요한 바람길을 특정하였다. 또한, 이를 바탕으로 전주시 일대의 산림관리 및 도시계획 활용방안을 제안하였다. 찬공기 특성 분석을 위해 독일에서 개발된 모형인 KALM(Kaltluftabflussmodell)을 이용하여 야간 6시간 동안 생성되는 찬공기 흐름 및 찬공기층 높이를 파악하였다. 분석 결과, 시간이 경과함에 따라 전주시 외곽 북동쪽 및 동쪽에 위치한 산림에서 생성된 찬공기의 흐름이 뚜렷해지고, 계곡지역과 농경지 일대에서 찬공기층의 높이가 증가하였다. 특히, 전주시의 찬공기 흐름은 북동쪽과 동쪽에서 생성된 찬공기가 전주시 중심 시가지로 유입되어 남쪽으로 흘러나가는 형태를 가지고 있어, 이상적인 바람길의 구조를 보여주는 사례였다. 찬공기 분석 결과를 바탕으로, 찬공기 생성이 활발한 산림지역 일대를 '찬공기 보전지역'으로 지정하고, 원활한 찬공기 흐름을 위해 관리가 필요한 지역을 '찬공기 관리지역'으로 지정하여, 찬공기 흐름을 유지 및 확대할 수 있는 방안을 제안하였다. 본 연구의 결과는 전주시의 기후변화 적응 정책, 바람길숲 조성 사업 등 폭염과 미세먼지 해결을 위한 정책 수립과 연구의 기초자료로 활용될 수 있을 것으로 기대한다.

LNG 냉열을 이용한 공기액화분리시스템의 시뮬레이션 및 공정 해석 (Process Analysis and Simulation for System of Air Liquefaction Separation Using LNG Cold Energy)

  • 한단비;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.276-281
    • /
    • 2019
  • The process of separating oxygen and nitrogen from the air is mainly performed by electric liquefaction, which consumes a lot of electricity, resulting in higher operating costs. On the other hand, when used for cold energy of LNG, electric power can be reduced compared to the electric Linde cycle. Currently, LNG cold energy is used in the cold refrigeration warehouse, separation of air-liquefaction, and LNG cold energy generation in Japan. In this study, the system using LNG cold energy and the Linde cycle process system were simulated by PRO/II simulators, respectively, to cool the elevated air temperature from the compressor to about $-183^{\circ}C$ in the air liquefaction separation process. The required amount of electricity was compared with the latent heat utilization fraction of LNG, the LNG supply pressure, and the LNG cold energy usage. At the air flow rate of $17,600m^3/h$, the power source unit of the Linde cycle system was $0.77kWh/m^3$, compared with $0.3kWh/m^3$.

자동차 냉각수 폐열회수 열전발전 시스템의 성능에 관한 연구 (An Experimental Study on Thermoelectric Generator Performance for Waste Coolant Recovery Systems in Vehicles)

  • 이대웅
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.329-334
    • /
    • 2014
  • This study indicated the possibility of energy regeneration from waste coolant heat, by using thermoelectric generation integrated with heat pipe. The internal combustion engine rejects more than 60% wasteful energy to the atmosphere by heat. The thermoelectric generator has recently been studied, to convert the energy from engine waste heat into electricity. For coolant waste heat recovery, a thermoelectric generator was investigated, to find out the possibility of vehicular application. Performance characteristics were conducted with various test conditions of coolant temperature, coolant mass flow rate, air temperature, and air velocity, with the thermoelectric generator installed either horizontally or vertically. Experimental results show that the electric power and conversion efficiency increases according to the temperature difference between the hot and cold side of the thermoelectric generator, and the coolant flow rate of the hot side heat exchanger. Performance improvement can be expected by optimizing the heat pipe design.

실험실 규모 순환유동층 연소로에서 2차공기 주입이 냉간유동에 미치는 영향 (Secondary Air Injection Effect on Cold Flow in a Laboratory-scale Circulating Fluidized Bed Combustor)

  • 장석돈;라승혁;황정호;강경태
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.217-228
    • /
    • 2000
  • Circulating Fluidized Bed Combustor(CFBC) has been used for the incineration of waste sewage sludge and for the power generation. In this study hydrodynamic characteristics of two phase flow have been studied in a riser section of CFBC. A lab-scale riser is designed and SiC (Geldart type B) is used for solid particles. Experiments are performed by controlling the fluidization parameters including superficial velocity and secondary air to primary air ratio for determination of solid holdup profiles in the riser. Superficial velocities of each fluidization regime are well agreed with results predicted by a theoretical model. The results show that the axial solid holdup distributions calculated by measuring differential static pressures in the riser are found to show a basic profile described by a simple exponential function. Our flow regime during experiments mainly belongs to fast fluidization regime for particle size of 300${\mu}m$. As the SA/PA ratio increases, solid holdup in the lower dense region of the riser increases.

  • PDF

충진재(Filler)가 대향류형(Counter Flow Type) 냉각탑 유동에 미치는 영향에 대한 연구 (Effect of Filler on the Flow of Counter Flow Type Cooling Tower)

  • 신정훈;이준경;진철규
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.565-572
    • /
    • 2022
  • The white plume from the cooling tower can be generated by mixing between discharging hot and humid air and cold air outside. This causes various problems such as icing, traffic disturbances, and fire factors in the vicinity, moreover it can also damage the image of a company. Various methods can be used to prevent white plume, one of them is to install a heat exchanger at the outlet of the cooling tower so that the heat exchanger transfers as much heat as possible to lower the temperature. Therefore the air flow path in the cooling tower should be optimized. Installation of the filler can be used to make the air flow better, thus we investigate the effect of filler on the air flow using CFD method. The pressure and velocity profile in the cooling tower could be acquired by the calculations. The filler made the velocity of the air entering the heat exchanger uniform this was because high flow resistance of the filler suppresses the generation of eddy in the cooling tower. But the total air pressure drop increased about 2 times with filler because the pressure drop by the filler accounted for about 60% of the total pressure drop.

냉각에너지를 활용한 바람길 구성요소 분류 - 대구광역시를 사례로 - (Classification of Wind Corridor for Utilizing Heat Deficit of the Cold-Air Layer - A Case Study of the Daegu Metropolitan City -)

  • 성욱제;엄정희
    • 한국조경학회지
    • /
    • 제51권5호
    • /
    • pp.70-83
    • /
    • 2023
  • 최근 산림청이 기후 변화 대응 대책으로써 지자체 바람길숲 조성 사업을 시행함에 따라 다양한 바람길에 대한 연구가 수행되어 오고 있다. 바람길숲 조성을 위해서는 바람길 기능에 대한 평가가 선행되어야 한다. 하지만, 현재 바람길을 직접적으로 평가하고, 바람길의 유형에 따라 공간을 구분할 평가 지표가 없어 간접적인 지표를 기준으로 분석을 수행하고 있다. 따라서 본 연구에서는 냉각에너지 분석을 찬공기 생성에 대한 평가 지표로 활용함으로써 바람길을 평가 및 분류하는 방법을 제안하였다. Kaltluftabflussmodell_21(KLAM_21)이라는 찬공기 분석 모형을 활용하여 냉각에너지 분석을 하였다. 그리고 시뮬레이션 분석 결과에 따라 바람길을 찬공기 생성지역, 찬공기 취약지역, 찬공기 유동지역으로 분류하였다. 냉각에너지량을 기준으로 상위 5퍼센트를 찬공기 생성지역, 하위 5퍼센트를 찬공기 취약지역으로 분류하였다. 또한 찬공기 유동지역은 찬공기 생성지역에서 이동하는 찬공기의 흐름을 파악하여 분류하였다. 분석 결과, 대구광역시의 바람길 6개의 바람 생성지역이 존재하며, 찬공기 취약지역은 시가지 내부에 집중되어 있었고, 찬공기 유동지역은 대구광역시의 주요 하천과 도로를 따라 형성되어 있었다. 본 연구의 방법론을 통해 바람길의 효과를 정량적 평가 방법으로 활용될 수 있을 것으로 기대된다. 또한 바람길숲 조성 사업지 선정에 제시할 수 있는 평가 지표로 활용될 것으로 판단된다.

KLAM_21을 활용한 바람생성기능 평가분석 연구 -대구시를 대상으로- (A Study on Evaluation Analysis of Wind Formation Function using KLAM_21 -The Case of Daegu City-)

  • 류지원;정응호;김대욱;차재규;손경수
    • 한국지리정보학회지
    • /
    • 제11권2호
    • /
    • pp.85-92
    • /
    • 2008
  • 본 연구는 KLAM_21을 활용한 바람형성기능 평가분석에 관한 연구로서 대구시를 사례대상지로 실제 도시공간상에서 지형조건과 토지이용에 따라 어떻게 바람이 유동하고 있는지를 살펴보았다. 먼저, 신천상류 가창골 일대의 계곡과 주변산지 경사면에서 형성된 찬공기는 신천상류를 따라 북쪽으로 유동되어 확장되고 있었으며, 시간이 경과함에 따라 찬공기의 양과 높이 그리고 유속 및 방향 등에 있어서도 점점 증가하는 추세를 보이고 있었다. 이는 이 지역의 공간적 특성이 찬공기가 생성되고 유동하는데 있어서 매우 양호한 조건을 가지고 있음을 알 수 있다. 한편, 앞산공원지역에서는 앞산공원일대를 가로지르는 고가도로와 바람의 유동을 방해하는 대규모의 아파트단지 밀집, 그리고 공원내의 건축물 등의 도시개발의 행위로 인하여 찬공기의 생성 및 유동이 크게 방해를 받고 있는 것으로 나타났으며, 찬공기의 양과 높이에 있어서도 미약하게 나타나고 있다. 결국, 바람길의 공간적 효과를 극대화시키기 위해서는 바람길생성의 기본 형태인 찬공기 형성 및 유동, 그리고 찬공기 축적 및 유지지역이 공간적으로 연계되어야 하며, 이러한 공간적 연계는 지역의 공간적 특성과 밀접한 관계가 있음을 알 수 있다.

  • PDF