• Title/Summary/Keyword: Coincidence summing factors

Search Result 5, Processing Time 0.024 seconds

True coincidence summing correction factor for point source geometry with PHITS

  • Esra Uyar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4472-4476
    • /
    • 2023
  • In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/calculated in gamma-ray spectrometric studies.

Efficiency calibration and coincidence summing correction for a NaI(Tl) spherical detector

  • Noureddine, Salam F.;Abbas, Mahmoud I.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3421-3430
    • /
    • 2021
  • Spherical NaI(Tl) detectors are used in gamma-ray spectrometry, where the gamma emissions come from the nuclei with energies in the range from a few keV up to 10 MeV. A spherical detector is aimed to give a good response to photons, which depends on their direction of travel concerning the detector center. Some distortions in the response of a gamma-ray detector with a different geometry can occur because of the non-uniform position of the source from the detector surface. The present work describes the calibration of a NaI(Tl) spherical detector using both an experimental technique and a numerical simulation method (NSM). The NSM is based on an efficiency transfer method (ETM, calculating the effective solid angle, the total efficiency, and the full-energy peak efficiency). Besides, there is a high probability for a source-to-detector distance less than 15 cm to have pulse coincidence summing (CS), which may occur when two successive photons of different energies from the same source are detected within a very short response time. Therefore, γ-γ ray CS factors are calculated numerically for a 152Eu radioactive cylindrical source. The CS factors obtained are applied to correct the measured efficiency values for the radioactive volumetric source at different energies. The results show a good agreement between the NSM and the experimental values (after correction with the CS factors).

Evaluate the usefulness of Coincidence Summing Correction Factors for Cylinder and Extended Source Penelope Simulation (실린더 및 확장 소스 PENELOPE 시뮬레이션에 대한 동시합성보정 계수 유용성 평가)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.821-831
    • /
    • 2021
  • In order to calibrate energy and efficiency using the PENELOPE Code, a PENELOPE simulation was performed using a volume source. Here, we want to verify peak efficiency and usefulness by performing simultaneous measurement and correction. calculate the coincident sum correction for all volumes, first subdivide the volumes of the cylinder and the four Marinelli beakers into three heights again. Therefore, the simultaneous measurement correction coefficient in three areas and the simultaneous measurement correction coefficient for the entire volume source are calculated as output. At low energies, the j value for each source volume (50-300 ml) is small and increases significantly in the high energy range. Simulation results showed good agreement within 2.5% for all source volumes except for 50 ml and 300 ml, which were up to 4%. This means that the correction for the simultaneous measurement effect during measurement is effective. In addition. Based on this, it can be confirmed that there is an advantage to improve the detection efficiency when measuring various sources and environmental samples.

Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source

  • Badawi, Mohamed S.;Thabet, Abouzeid A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1421-1430
    • /
    • 2022
  • The computation of the solid angle and the detector efficiency is considering to be one of the most important factors during the measuring process for the radioactivity, especially the cylindrical γ-ray NaI(Tl) detectors nowadays have applications in several fields such as industry, hazardous for health, the gamma-ray radiation detectors grow to be the main essential instruments in radiation protection sector. In the present work, a generic numerical simulation method (NSM) for calculating the efficiency of the γ-ray spectrometry setup is established. The formulas are suitable for any type of source-to-detector shape and can be valuable to determine the full-energy peak and the total efficiencies and P/T ratio of cylindrical γ-ray NaI(Tl) detector setup concerning the truncated conical radioactive source. This methodology is based on estimate the path length of γ-ray radiation inside the detector active medium, inside the source itself, and the self-attenuation correction factors, which typically use to correct the sample attenuation of the original geometry source. The calculations can be completed in general by using extra reasonable and complicate analytical and numerical techniques than the standard models; especially the effective solid angle, and the detector efficiency have to be calculated in case of the truncated conical radioactive source studied condition. Moreover, the (NSM) can be used for the straight calculations of the γ-ray detector efficiency after the computation of improvement that need in the case of γ-γ coincidence summing (CS). The (NSM) confirmation of the development created by the efficiency transfer method has been achieved by comparing the results of the measuring truncated conical radioactive source with certified nuclide activities with the γ-ray NaI(Tl) detector, and a good agreement was obtained after corrections of (CS). The methodology can be unlimited to find the theoretical efficiencies and modifications equivalent to any geometry by essential sufficiently the physical selective considered situation.

The Effect of Applying Self-absorption and Coincidence Summation Correction when Measuring Environmental Samples (환경시료 측정 시 자체흡수 및 동시합성 보정 적용 효과)

  • Eun-Sung Jang;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.531-539
    • /
    • 2023
  • Self-absorption is the most important factor affecting the accuracy of gamma spectroscopy measurements in environmental samples. In particular, it is affected by other factors such as the chemical composition of the sample, geometric shape, thickness, density, atomic number, distance between the sample and detector, energy of the emitted gamma photon, and humidity coefficient or percentage in the sample. To test the calibration method, a 450 ml CRM standard source (9 nuclide) Marinelli beaker was used. Five soil samples among environmental samples were measured by density by applying the corrected values. Therefore, it can be seen that the self-absorption value is more effective for somewhat large and low photon energy. In the case of environmental samples, it was confirmed that the overall energy peak efficiency through self-absorption of the source greatly depends on the density of the sample.