• Title/Summary/Keyword: Coils

Search Result 1,148, Processing Time 0.028 seconds

Molecular Cloning of Two Genes Encoding Cinnamate 4-Hydroxylase (C4H) from Oilseed Rape (Brassica napus)

  • Chen, An-He;Chai, You-Rong;Li, Jia-Na;Chen, Li
    • BMB Reports
    • /
    • v.40 no.2
    • /
    • pp.247-260
    • /
    • 2007
  • Cinnamate 4-hydroxylase (C4H) is a key enzyme of phenylpropanoid pathway, which synthesizes numerous secondary metabolites to participate in development and adaption. Two C4H isoforms, the 2192-bp BnC4H-1 and 2108-bp BnC4H-2, were cloned from oilseed rape (Brassica napus). They both have two introns and a 1518-bp open reading frame encoding a 505-amino-acid polypeptide. BnC4H-1 is 57.73 kDa with an isoelectric point of 9.11, while 57.75 kDa and 9.13 for BnC4H-2. They share only 80.6% identities on nucleotide level but 96.6% identities and 98.4% positives on protein level. Showing highest homologies to Arabidopsis thaliana C4H, they possess a conserved p450 domain and all P450-featured motifs, and are identical to typical C4Hs at substrate-recognition sites and active site residues. They are most probably associated with endoplasmic reticulum by one or both of the N- and C-terminal transmembrane helices. Phosphorylation may be a necessary post-translational modification. Their secondary structures are dominated by alpha helices and random coils. Most helices locate in the central region, while extended strands mainly distribute before and after this region. Southern blot indicated about 9 or more C4H paralogs in B. napus. In hypocotyl, cotyledon, stem, flower, bud, young- and middle-stage seed, they are co-dominantly expressed. In root and old seed, BnC4H-2 is dominant over BnC4H-1, with a reverse trend in leaf and pericarp. Paralogous C4H numbers in Brassicaceae genomes and possible roles of conserved motifs in 5' UTR and the 2nd intron are discussed.

Pathological Studies on the New Microsporidia K79 Isolated from the Silkworm, Bombyx mori L. II. Pathogenicity and Developmental Progress of the Microsporidia. (가잠에서 분리된 새로운 미포자충 K79의 병리학적 연구 II. 미포자충의 병원성 및 발육경과)

  • 윤재수;임종성
    • Journal of Sericultural and Entomological Science
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • In order to clarify the taxanomic position of a new microsporidia K79 which was isolated from the silkworm larvae, Bombyx mori L. in Korea in 1979, the following several experiments such as estimation of pathogenicity in different instar, histopathological examination under light and electronic microscope and examination of fine structure of the sporse were carried out and their result obtained are as follows. In the test of pathogenicity by oral inoculation, the new microsporidia K79 was lower than Nosema bombycis and the susceptibility of the new microsporidia to silkworm was getting lower as the silkworm larvae grew. The lesion of Silkworms' tissue which was infected with the new microsporidia K79 was found in the epithelial cells of trachea, fat body and silk gland cells. The developmental process of the new microsporidia K79 in vivo could be divided into the following five stages: sporoplasm, schizont, sporont, sporoblast, and spore. The process was just the same as the of N. bombycis, but its development was slower than that of N. bombycis. Several differences in the fine structure of the spore under electron microscope, which could be important keys for the classification of microsporidia, were obtained. Anchoring disk and polaroplast lamella of the new microsporidian spore were disclosed to be different from those of N. bombycis. An average number of polar filament coils of the new microporidian spore was 16 at an angle of 75$^{\circ}$. On the basis of various keys for the classification of microsporidia, the results obtained from various experiments proved that the newly isolated microsporidia should be classified into the Genus, "Nosema", nut is further classification for species should be conducted in the future. Therefore, it may be reasonable that the new microsporidia is temperally classified as Nosema sp. K79 considering the fact that it was discovered in Korea in 1979.a in 1979.

  • PDF

Enhanced Expression of Phospholipase C-$\gamma$1 in Regenerating Murine Neuronal Cells by Pulsing Electromagnetic Field (흰쥐에서 편측 반회후두신경 재지배 후 Phopholipase C-$\gamma$1(PLC-$\gamma$1)의 발현과 후두기능회복과의 관계)

  • 정성민;신혜정;김성숙;김문정;윤선옥;박수경;신유리;김진경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.2
    • /
    • pp.126-132
    • /
    • 2001
  • Background and Objectives : Signal traduction through phospholipase C(PLC) participate in the regulation of cell growth and differentiation. Growth factors bind to their receptors and thereby induce tyrosine phophorylation of the phospholipase C-${\gamma}$1(PLC-${\gamma}$1). PLC-${\gamma}$1 is a substrate for several receptor tyrosine kinases and its catalytic activity is increased by tyrosine phosphorylation. Tyrosine kinase phosphorylation of PLC-${\gamma}$1 stimulates PLC activation and cell proliferation. However the signal transduction pathway and the significance of PLC in injured recurrent laryngeal nerve regeneration is unknown. Therefore after we obtained fuctionally recovered rats using PEMF in this study, we attempt to provide some evidence that PLC plays a role in nerve regeneration itself and regeneration related to PEMF through the analysis of the difference between fucntional recovery group and non-recovery group in the recurrent laryngeal nerve. Materials and Method : Using 32 healthy male Sprague-Dawley rats, transections and primary anastomosis were performed on their left recurrent laryngeal nerves. Rats were then randomly assigned to 2 groups. The experimental group(n=16) received PEMS by placing them in custom cages equipped with Helm-holz coils(3hr/day, 5days/wk, for 12wk). The control group(n=16) were handled the same way as the experimental group, except that they did not receive PEMS. Laryngo-videoendoscopy was performed before and after surgery and followed up weekly. Laryngeal EMG was obtained in both PCA and TA muscles. Immunohistochemisty staining and Western blotting analysis using monoclonal antibody was performed to detect PLC-${\gamma}$1 in recurrent laryngeal nerve and nodose ganglion. Results : 10 rats(71%) in experimental group and 4 rats(38%) in the control group showed recovery of vocal fold motion. Functionally-recoverd rats show PLC-${\gamma}$1 positive cells in neuron and ganglion cells after 12 weeks from nerve injury. Conclusion : This study shows that PLC1-${\gamma}$ involved in singnal trasduction pathway in functinal recovery of injured recurrent laryngeal nerve and PEMF enhance the functional recovery by effect on this molecule.

  • PDF

Design and Control of Ultra-precision Dual Stage with Air bearings and Voice coil motor for nm scanning system (나노 정밀도 스캐닝 용 공기베어링과 보이스 코일 모터의 초정밀 이중 스테이지 설계 및 제어)

  • Kim K.H.;Choi Y.M.;Kim J.J.;Lee M.G.;Lee S.W.;Gweon D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1883-1886
    • /
    • 2005
  • In this paper, a decoupled dual servo (DDS) stage for ultra-precision scanning system with large working range is introduced. In general, dual servo systems consist of a fine stage for short range and a coarse stage for long range. The proposed DDS also consists of a $XY\theta$ fine stage for handling and carrying workpieces and one axis coarse stage. Its coarse stage consists of air bearing guide system and a coreless linear motor with force ripple. The fine has four voice coil motors(VCM) as its actuator. According to a VCM's nature, there are no mechanical connections between coils and magnetic circuits. Moreover, VCM doesn't have force ripples due to imperfections of commutation components of linear motor systems - currents and flux densities. However, due to the VCM's mechanical constraints the working range of the fine is about $25mm^2$. To break that hurdle, the coarse stage with linear motors is used to move the fine about 500mm. Because of the above reasons, the proposed DDS can achieve higher precision scanning than other stages with only one servo. With MATLAB's Sequential Quadratic Programming (SQP), the VCMs are optimally designed for the highest force under conditions and constraints such as thermal dissipations due to its coil, its size, and so on. And for their movements without any frictions, guide systems of the DDS are composed of air bearings. To get precisely their positions, a linear scale with 5nm resolution are used for the coarse stage's motion and three plane mirror laser interferometers with 5nm for the fine's $XY\theta$ motions. With them, on scanning the two stages have same trajectories. The control algorithm is named Parallel method. The embodied ultra-precision scanning system has sub 100nm following error and in-positioning stability.

  • PDF

Transarterial Coil Embolization in Two Maltese Dogs with Patent Ductus Arteriosus Using a Mini Cobra-tip Angiocatheter (말티스 견에서 시술된 미니코브라 카테터와 코일을 이용한 동맥관 개존증의 치료 2 증례)

  • Han, Dong-Hyun;An, Hyo-Jin;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.740-745
    • /
    • 2010
  • Patent ductus arteiosus (PDA) is the persistent opening of ductus arterious located between pulmonary artery and descending aorta after birth. Although PDA can be occluded by surgical ligation, interventional closure of PDA using various devices is being rapidly replaced to surgical ligation, because of its non-invasive nature of treatment and minimal post-care after treatment. Main problem encountering in interventional treatment in toy breed dogs is vascular inaccessibility due to small size of artery. Although transvenous approach using jugular veins has been developed, this technique requires experienced skill to locate occlude devices into PDA and has high risk of accidental dislodgement of occluding devices (i.e. embolization coils or vascular plugs). Therefore, in this study, we developed a modified technique for coil embolization using mini-angiocatheter with trans-femoral approach in toy breed dogs (< 3.0 kg of body weight). With this modified method, we were successfully treated two toy breed (Maltese) dogs with the left to right shunted PDA.

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • Huh, Jin;Park, Eun-Ha;Jung, Gu-Ho;Rim, Chun-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

Development of Switching and Heating Devices in Embedded Rack Track for Environmental-friendly Mountain Railway (친환경 산악철도 매립형 궤도의 선로전환기 및 히팅장치 개발)

  • Seo, Sung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.503-510
    • /
    • 2020
  • Eco-friendly mountain railways operate on concrete rack tracks embedded on existing sharp curved and steep roads to preserve the environment in mountainous areas. Owing to the narrow roads, single lines are inevitable, and many branches are required. In branches, previous switchers and heating devices cannot be applied, because of the limited spacing for the rack and the slow removal of thick ice. To solve these problems, a switch and a heating device have been developed. The switcher changes the line by moving the block of concrete track with hydraulic actuators. The lack of discontinuity reduces the derailment risk and makes locking simple. The heating device uses high frequency induction coils to increase the efficiency and melt the thick ice rapidly. The prototype switcher and heating device were produced and operated to prove their performance. The heating device yielded a 10 times greater efficiency than the previous one. The switcher and heating device are the essential core technologies for the operation of mountain trams in winter and contribute to the spread of mountain railways to domestic or foreign resort areas by enhancing safety and efficiency. In addition, they can provide transportation rights to local residents in poor winter traffic, and bring about tourism and local economic growth.

Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

  • Jin, Bo Kyung;Bang, Ji Seok;Choi, Eun Young;Kim, Gi Beom;Kwon, Bo Sang;Bae, Eun Jung;Noh, Chung Il;Choi, Jung Yun;Kim, Woong Han
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.125-129
    • /
    • 2013
  • Purpose: The use of implantable cardioverter defibrillators (ICDs) to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was $14.5{\pm}5.4$ years (range, 2 to 22 years). The follow-up duration was $28.9{\pm}20.4$ months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1), cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years). Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia. During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

Simple Coiling versus Stent-Assisted Coiling of Paraclinoid Aneurysms : Radiological Outcome in a Single Center Study

  • Kim, Soo Yeon;Park, Dong Sun;Park, Hye Yin;Chun, Young Il;Moon, Chang Taek;Roh, Hong Gee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.644-653
    • /
    • 2017
  • Objective : Paraclinoid aneurysms are a group of aneurysms arising at the distal internal carotid artery. Due to a high incidence of small, wide-necked aneurysms in this zone, it is often challenging to achieve complete occlusion when solely using detachable coils, thus stent placement is often required. In the present study, we aimed to investigate the effect of stent placement in endovascular treatment of paraclinoid aneurysms. Methods : Data of 98 paraclinoid aneurysms treated by endovascular approach in our center from August 2005 to June 2016 were retrospectively reviewed. They were divided into two groups : simple coiling and stent-assisted coiling. Differences in the recurrence and progressive occlusion between the two groups were mainly analyzed. The recurrence was defined as more than one grade worsening according to Raymond-Roy Classification or major recanalization that is large enough to permit retreatment in the follow-up study compared to the immediate post-operative results. Results : Complete occlusion was achieved immediately after endovascular treatment in eight out of 37 patients (21.6%) in the stent-assisted group and 18 out of 61 (29.5%) in the simple coiling group. In the follow-up imaging studies, the recurrence rate was lower in the stent-assisted group (one out of 37, 2.7%) compared to the simple coiling group (13 out of 61, 21.3%) (p=0.011). Multivariate logistic regression model showed lower recurrence rate in the stent-assisted group than the simple coiling group (odds ratio [OR] 0.051, 95% confidence interval [CI] 0.005-0.527). Furthermore there was also a significant difference in the rate of progressive occlusion between the stent-assisted group (16 out of 29 patients, 55.2%) and the simple coiling group (10 out of 43 patients, 23.3%) (p=0.006). The stent-assisted group also exhibited a higher rate of progressive occlusion than the simple coiling group in the multivariate logistic regression model (OR 3.208, 95% CI 1.106-9.302). Conclusion : Use of stents results in good prognosis not only by reducing the recurrence rate but also by increasing the rate of progressive occlusion in wide-necked paraclinoid aneurysms. Stent-assisted coil embolization can be an important treatment strategy for paraclinoid aneurysms when considering the superiority of long term outcome.