• Title/Summary/Keyword: Coils

검색결과 1,148건 처리시간 0.029초

Types of Thromboembolic Complications in Coil Embolization for Intracerebral Aneurysms and Management

  • Kim, Hong-Ki;Hwang, Sung-Kyun;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.226-231
    • /
    • 2009
  • Objective : We describe our clinical experiences and outcomes in patients who had thromboembolic complications occurring during endovascular treatment of intracerebral aneurysms with a review of the literature. The types of thromboembolic complications were divided and the treatment modalities for each type were described. Methods : Between August 2004 and March 2009 we performed endovascular embolization with Guglielmi detachable coils for 173 patients with 189 cerebral aneurysms, including ruptured and unruptured aneurysms at our hospital. Sixty-eight patients were males and 105 patients were females. The age of patients ranged from 22-82 years (average, 58.8 years). We retrospectively evaluated this group with regard to complication rates and outcomes. The types of thromboembolic complications were classified into the following three categories: mechanical obstruction, distal embolic stroke, and stent-induced complications, which corresponded to types I, II, and III, respectively. A comparison of the clinical results was made for each type of complication. Results : Only eight patients had a thromboembolic complication during or after a procedure (4.6%). Of the eight patients, two had a mechanical obstruction as the causative factor; the other three patients had distal embolic stroke as the causative factor. The remaining three patients had stent-induced complications. In cases of mechanical obstruction, recanalization occurred due to the use of intra-arterial thrombolytic agents in one of two patients. Nevertheless, a poor prognosis was seen. In the cases of stent-induced complications, in one of three patients in whom a thrombus developed following stent insertion, a middle cerebral artery territory infarct developed with a poor prognosis despite the use of wiring and an intra-arterial thrombolytic agent. In the cases of distal embolic stroke, all three patients achieved good results following the use of antiplatelet agents. Conclusion : Treatment for thromboemboic complications due to mechanical obstruction and stent-induced complications include antiplatelet and intra-arterial thrombolytic agents; however, this cannot guarantee a sufficient extent of effectiveness. Therefore, active treatments, such as balloon angioplasty, stent insertion, and clot extraction, are helpful.

단전류-다층 솔레노이드 방법을 사용한 저자장 표준시스템 제작 (Construction of Low Magnetic Standard System using a Multi-layer Solenoid with Single-current)

  • 박포규;김영균
    • 한국자기학회지
    • /
    • 제11권1호
    • /
    • pp.38-44
    • /
    • 2001
  • 저자장 영역(1 mT 이하)에서 국가 표준시스템을 분해능 0.26 nT 수준으로 확립하였다. 비자성 재료로 건축하여 자성체에 의한 영향을 배제할 수 있는 비자성동에서 세슘 광펌핑 마그네토미터, 3-축 헬름홀츠 코일 등을 이용하여 자동적으로 지자장을 상쇄시키는 장치를 만들었다. 그 특성은 대역폭 10 Hz에서 0.1 nT/10 min이었다. 지자장이 상쇄된 공간에 최적 설계한 단전류-다층 솔레노이드(길이 1.02 m, 평균반경 0.l1467 m, 단위길이당 권선수 1000 turns/m)를 설치하고, 솔레노이드에 정밀 전류를 홀려 자장을 발생시키는 방법을 사용하여 저자장 표준시스템의 성능을 향상시켰다. 솔레노이드 중심에서 자장의 안정도는 $\pm$ 1 cm 범위에서 1.0$\times$$10^{-7}$ T이었다. 핼륨 광펌핑 마그네토미터를 이용하여 측정한 솔레노이드의 코일상수는 1.231 058 9 mT/A이고, 온도계수는 0.38 nT/$^{\circ}C$이었다. 저자장 표준시스템은 저자장 측정기의 교정 및 저자장관련 시험검사 등에 사용된다.

  • PDF

Morphology of Arbuscular Mycorrhizal Roots and Effects of Root Age and Soil Texture on the Mycorrhizal Infection in Panax ginseng C.A. Meyer

  • Lee, Kyung-Joon;Park, Hoon;Lee, In-Sik
    • Journal of Ginseng Research
    • /
    • 제28권3호
    • /
    • pp.149-156
    • /
    • 2004
  • The objectives of this study were to investigate the morphology of mycorrhizal roots, and the effects of root age and soil texture on the mycorrhizal infection in ginseng (Panax ginseng C. A. Meyer) growing in Korea. Ginseng roots at ages of two to six years were collected from fields in late June. Their infection by arbuscular mycorrhizal fungi(AMF) was studied by clearing the roots and staining fungal hyphae with trypan blue. Root infection varied greatly depending on the developmental stages of young roots. Young tertiary roots, in diameter of smaller than 0.8 mrn, formed during the current growing season had root hairs and were frequently and in some cases heavily infected by AMF. Hyphal coils and arbuscules were abundant, while vesicles were rarely observed. Older secondary or tertiary roots in diameter of bigger than 1.0 mm with fully differentiated primary xylem formed during the previous growing season had no root hairs, and were not infected at all. The rates of mycorrhizal infection in the young tertiary roots were not affected by the age of the ginseng plants, suggesting that fungal populations might have not much changed during the aging of the cultivated fields up to six years. The differences in the infection rates among the different ages of ginseng were caused by differences in the amount of young tertiary roots in the samples. Soil texture, either sandy loam or clay loam, did not affect the rate of root infection. There were large variations in the infection rates among the different farms and locations within a farm. It strongly suggested that infection rates of the ginseng roots by AMF would be influenced by the practice of the farmers, possibly by avoiding consecutive planting, introduction of new topsoil, and the ways of handling the soil before transplanting the ginseng, such as fumigation or sterilization that might have affected indigenous inoculum sources of the AMF.

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

다중 공진을 이용한 이중 부이 파력발전장치의 모형실험 (Model Test of Dual-Buoy Wave Energy Converter using Multi-resonance)

  • 김정록;현종우;고혁준;권혁민;조일형
    • 한국해양공학회지
    • /
    • 제29권2호
    • /
    • pp.191-198
    • /
    • 2015
  • In this study, we proposed a new type of dual-buoy wave energy converter (WEC) exploiting multi-resonance and analyzed the experimental results from a model test in a 2-D wave flume. A dual-buoy WEC using multi-resonance has two advantages: high efficiency at the resonant frequencies and the potential to extend the frequency range available to extract wave power from the WEC. The suggested WEC was composed of an outer buoy and an inner buoy sliding vertically inside the outer buoy. As the power take-off device, a linear electric generator (LEG) consisting of permanent magnets and coils fixed at each buoy was adopted. Electricity was produced by the relative heave motion between the two buoys. To search for the optimal shape of a dual-buoy WEC, we conducted experiments on the heave motion of a two-body system in regular waves without an LEG installed. Model tests with six combinations of experimental models were conducted in order to find the motion characteristics of a dual-buoy WEC. It was found that model 2, which included a ring-shaped appendage to move the resonant frequency of the outer buoy toward a high value, showed a higher relative heave response amplitude operator (RAO) curve than model 1. In addition, the double-peak shape of the heave RAO curve shown for model 2 indicated the extension of the frequency range for extracting wave power in irregular waves.

Superconducting Magnet Power Supply System for the KSTAR 2nd Plasma Experiment and Operation

  • Choi, Jae-Hoon;Lee, Dong-Keun;Kim, Chang-Hwan;Jin, Jong-Kook;Han, Sang-Hee;Kong, Jong-Dae;Hong, Seong-Lok;Kim, Yang-Su;Kwon, Myeun;Ahn, Hyun-Sik;Jang, Gye-Yong;Yun, Min-Seong;Seong, Dae-Kyung;Shin, Hyun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.326-330
    • /
    • 2013
  • The Korea Superconducting Tokamak Advanced Research (KSTAR) device is an advanced superconducting tokamak to establish scientific and technological bases for attractive fusion reactor. This device requires 3.5 Tesla of toroidal field (TF) for plasma confinement, and requires a strong poloidal flux swing to generate an inductive voltage to produce and sustain the tokamak plasma. KSTAR was originally designed to have 16 serially connected TF magnets for which the nominal current rating is 35.2 kA. KSTAR also has 7 pairs of poloidal field (PF) coils that are driven to 1 MA/sec for generation of the tokamak plasma according to the operation scenarios. The KSTAR Magnet Power Supply (MPS) was dedicated to the superconducting (SC) coil commissioning and $2^{nd}$ plasma experiment as a part of the system commissioning. This paper will describe key features of KSTAR MPS for the $2^{nd}$ plasma experiment, and will also report the engineering and commissioning results of the magnet power supplies.

KSTAR PF Coil용 CICC 제작 (Fabrication of KSTAR PF CICC)

  • 임병수;이상일;최정열;정우호;박현기;추용;박갑래;백설희;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.301-303
    • /
    • 2003
  • The KSTAR(Korea Superconducting Tokamak Advanced Research) superconducting magnet system consist of 16 TF(Toroidal Field) and 14 PF(Poloidal Field) coils. Internally-cooled cabled superconductors will be used for the magnet system. The magnet system adopt a superconducting CICC (Cable-In-Conduit Conductor) type. The KSTAR PF 6, 7 CICCs use NbTi Superconducting cable with stainless steel 316LN conduit while the other PF CICC use Incoloy 908 conduit. For the fabrication of PF CICC, superconducting cables have been fabricated and the cable has the diameter of 22.3mm. A continuous CICC jacketing system is developed for the CICC jacketing and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The cabling and the jacketing process is described. The welding condition and design specification of CICCs are also discussed. The fabrication results including the geometrical specification and the void fraction will be discussed.

  • PDF

A comparison on the heat load of HTS current leads with respect to uniform and non-uniform cross-sectional areas

  • Han, Seunghak;Nam, Seokho;Lee, Jeyull;Song, Seunghyun;Jeon, Haeryong;Baek, Geonwoo;Kang, Hyoungku;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권3호
    • /
    • pp.44-48
    • /
    • 2017
  • Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.

무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작 (Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission)

  • 김성태;차두열;강민석;조세준;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.

A Study on Effect of Environmental Characteristics by Intake Mixture Temperature in Scrubber EGR System Diesel Engines

  • Bae, Myung-Whan;Ryu, Chang-Sung
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2002년도 추계학술대회 발표 논문집
    • /
    • pp.100-111
    • /
    • 2002
  • The effects of intake mixture temperature on performance and exhaust emissions under four kinds of engine loads were experimentally investigated by using a four-cycle, four-cylinder, swirl chamber type, water-cooled diesel engine with scrubber EGR system operating at three kinds of engine speeds. The purpose of this study is to develop the scrubber exhaust gas recirculation(EGR) control system for reducing $NO_x$ and soot emissions simultaneously in diesel engines. The EGR system is used to reduce $NO_x$ emissions. And a novel diesel soot-removal device of cylinder-type scrubber with five water injection nozzles is specially designed and manufactured to reduce soot contents in the recirculated exhaust gas to the intake system of the engine. The influences of cooled EGR and water injection, however, would be included within those of scrubber EGR system. In order to survey the effect of intake mixture temperature on performance and exhaust emissions, the intake mixtures of fresh air and recirculated exhaust gas are heated by a heating device with five heating coils made of a steel drum. It is found that the specific fuel consumption rate is considerably elevated by the increase of intake mixture temperature, and that $NO_x$ emissions are markedly decreased as EGR rates are increased and intake mixture temperature is dropped, while soot emissions are increased with increasing EGR rates and intake mixture temperature. Thus one can conclude that the performance and exhaust emissions are considerably influenced by the cooled EGR.

  • PDF