• Title/Summary/Keyword: Coil diameter

Search Result 251, Processing Time 0.028 seconds

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

The effect of Coptidis rhizoma, Chinese Galls and Phytoncide in Malassezia furfur (황련(Coptidis rhizoma), 오배자(Chinese galls), 피톤치드 혼합물(Phytoncide)이 비듬균(Malassezia furfur)에 미치는 영향)

  • Kim, Joung-Hee;Kwack, Seung Jun;Cho, Yong-Kwon;Kim, Byung-Kwan;Kim, Jong Guk;Lee, Eunkyung;Cho, Hye-Kyung;Kim, Keuk-Jun
    • Journal of Life Science
    • /
    • v.25 no.7
    • /
    • pp.748-756
    • /
    • 2015
  • The report explores the possibility that the single extract of natural substances and the mixture of single extracts of natural substances create a synergy effect to increase the antimicrobial activity. It also compares the previous researches to find out if the natural medicinal herbs’ extract has antimicrobial activity on dandruff causative organism, Malassezia furfur. For the experiment on the mixture of single extracts of natural substances, the results are like following: 1. Staphylococcus aures’s antibacterial activity is resistant to mixture of three natural substances. 2. Escherichia coil’s antibacterial activity is resistant to mixture with Coptidis rhizoma. 3. Candida albicans’ antifungal activity is resistant to mixture with Chinese galls, which means the different results may be expected when tested with each germ. 4. On the other hand, Malassezia furfur has no antifungal activity on the single extract of natural substances and shows weak antifungal activity, whose diameter is 3.20 mm when tested with the mixture of 50% of Coptidis rhizoma and 50% of Phytoncide. The result is totally different from the one on the same eumycetes, C. albicans. That is because M. furfur has more lipophilic chemicaled cell walls than C. albicans does and it also consists of lamella layer, inner plasma membrane and intermediate multiple layers.

A Study on the Thermal Characteristics of a Coupler to Improve the Performance of Electrodeless Lamp (무전극 램프의 성능 향상을 위한 커플러의 열특성 연구)

  • Lee, Kye-Seung;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.487-495
    • /
    • 2017
  • The thermal characteristics of the electrodeless lamp are one of the main factors that determine the design and performance of the lamp. The coupler changes the impedance characteristic by heat and its use temperature is usually within about $150^{\circ}C$. In this study, we observed the phenomenon when the coupler was exposed at a temperature of $150^{\circ}C$ or higher, which has not been discussed so far. Two types of coupler A and coupler B with different spacing between the inner tube and the coupler were analyzed for electrical, thermal and optical properties and deterioration characteristics with different heat and heat shielding conditions. First, the impedance of the system is obtained and used as a criterion for analyzing the electrical characteristics through it. The diameters of the two types of couplers are 1 mm, and the experimental result shows that the coupler diameter is 1 mm, which can cancel out the loss of the magnetic field strength. Therefore, based on these results, when the coupler is exposed to high temperature of about $200^{\circ}C$, the efficient design method corresponding thereto is proposed.

The Effect of Direct Functional Magnetic Stimulation of the Lesion on Functional Motor Recovery in Spinal Cord Injured Rat (척수손상 흰 쥐의 운동기능 회복에 미치는 손상부위 직접자극을 통한 기능적 자기자극치료 효과)

  • Cho, Yun-Woo;Kim, Su-Jeong;Park, Hea-Woon;Seo, Jeong-Min;Hwang, Se-Jin;Jang, Sung-Ho;Lee, Dong-Gyu;Ahn, Sang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the effect of direct functional magnetic stimulation (FMS) of affected spinal cord on motor recovery following spinal cord injury in rats. Methods: After a contusion injury at the spinal level T9 using an NYU Impactor, functional magnetic stimulation was delivered by a magnetic stimulator through a round prototype coil (7 cm in diameter). Stimulation parameters were set as follows: repetition rate = 50 Hz (stimulus intensity 100% = 0.18 T), stimulation time = 20 min. Functional magnetic stimulation was administered twice a day, 5 days per week for 8 weeks starting 4 days after spinal cord injury. Functional magnetic stimulationwas delivered directly to the affected spinal cord. Outcomes of locomotor performance were assessed by the Basso Beattie Bresnahan (BBB) locomotor rating scale and by an inclined plane test weekly for 8 weeks. Results: In the BBB test, hindlimb motor function in the Functional magnetic stimulation group improved significantly more compared to the control group at 3, 4, 6, 7, and 8 weeks (p<0.05). In the inclined plane test, the angle of the plane in the functional magnetic stimulation group increased significantly more compared to the control group at 4, 5, 7, and 8 weeks (p<0.05). Conclusion: Our results demonstrate that direct Functional magnetic stimulation of the lesional site may have beneficial effects on motor improvement after spinal cord injury.

Development of an EMAT System for Detecting flaws in Pipeline (배관결함 검출을 위한 EMAT 시스템 개발)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2004
  • It is possible to detect flaws in pipelines without interruption using all EMAT transducer because it is a non-contact transducer which can transmit ultrasonic waves into specimens without couplant. And it ran easily generate guided waves desired in each specific problem by altering the design of coil and magnet. In the present work, EMAT systems have been fabricated to generate surface waves, and selectively the plate wave of $A_1\;or\;S_1$ mode. The surface wave of 1.5MHz showed a good signal-to-noise ratio without distortion in its propagation along a pipeline, while the $S_1$ mode of 800kHz and the $A_1$ mode of 940kHz were distorted according to their dispersive properties. The wider the excitation pulse becomes, the better the mode selectivity of the plate waves becomes. A pipe of 256mm inner diameter and 5.5m thickness with 5 flaws was used for comparing the flaw detectability among the modes under consideration.

Construction of Measuring System for Magnetic Properties Measurement of Azimuth Angle Sensor (방위각센서의 자기특성 측정 장치 제작)

  • Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.1
    • /
    • pp.22-27
    • /
    • 2014
  • North indicating azimuth angle sensors have been used in airplanes, ships traditionally and nowadays employed in smart phones. For the azimuth and roll angle measurement of the sensor, 3-axis acceleration sensor was added to the 3-axis magnetic field sensor. In this work, we have constructed a measuring system for the measurement of the magnetic field and the angle uncertainty of the magnetic field sensors. Measuring system could be useful not only in non-magnetic laboratory but also in normal laboratory, we constructed small size of 3-axis Helmholtz coils for the compensation environment magnetic field (Earth magnetic field and magnetic field from building) and the generation of magnetic field for the test of magnetic field sensor. The constructed measuring system could compensate environment magnetic field below 10 nT level and generate 3-dimensional magnetic field with magnitude uncertainty of 0.2 % and angle error of $0.2^{\circ}$ within the volume of ${\pm}30mm$ diameter at center of Helmholtz coils. For the conformation of developed measuring system, We tested commercially available 3-axis magnetometer and heading sensor.

A Design and Performance Evaluation of Semi-active MR Damper for the Smart Control of Construction Structures (건설구조물의 스마트 제어를 위한 준능동 MR 감쇠기의 설계 및 성능평가)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.165-171
    • /
    • 2009
  • This research developed two semi-active MR dampers whose gaps in the orifice area were different from each other, and evaluated their damping performance by loading tests. The Damping performance of MR dampers characteristically depends on various factors like their material and mechanical ones, but most importantly on the size of gap in the orifice area. For this research, we designed the orifice gaps of two dampers as each 1.0mm and 2.0mm, both with the 80mm outer diameter of the orifice. We also designed two loading test sets with different input currents, and acquired different control ability from them. The acquired test results were analyzed and evaluated with their maximum and minimum damping force and also their dynamic range from the force-displacement hysteresis loops and the force-input current relationship curve. This research clearly proved how the damping performance of control devices depends on the gap effect, and also presented a possibility that the two dampers developed in this research could be used for the smart control of construction structures by effectively adapting the input current and the number of coil turns.

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.