• Title/Summary/Keyword: Coil Design

Search Result 999, Processing Time 0.031 seconds

Design of 2T conduction cooled HTS magnet (2T급 전도냉각 고온 초전도 자석의 설계)

  • Sim, K.D.;Kim, S.H.;Sohn, M.H.;Min, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.817-818
    • /
    • 2006
  • A 2.0T class HTS conduction cooled magnet was designed. Designing of magnet shape was performed through two steps. First step is to find a basic cross section for minimize the amount of conductor used and second step to optimize the coil shape to satisfy the magnetic field homogeneity. The magnetic fields was analyzed with FEM and the critical current value of magnet was also expected with the result of field analysis and the Ic to B curve of Bi-2223 HTS tape.

  • PDF

Design of Optical Image Stabilization Actuator for Compensating Hand Tremble (손 떨림 방지를 위한 OIS 액추에이터의 설계)

  • Hur, Young-Jun;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.2
    • /
    • pp.75-79
    • /
    • 2011
  • Recently mobile phone camera become generally spread, it is required to develop high resolution, multi-functional camera module for obtaining high image quality. To satisfy this demand, number of pixels has been increased and pixel size decreased in small mobile phone cameras. As a result, image quality is seriously dropped by blur phenomena. Especially when hand tremble is occurred, image quality is dropped by camera shake. Therefore, to obtain high quality image, it is necessary to compensate user's hand tremble. In this paper, we propose voice coil actuator for compensating hand tremble, which can apply optical image stabilization (OIS) system. Sensitivity analysis and size optimization are performed to obtain high driving force. Finally, it is confirmed that the optimized electromagnetic circuit can be applied in OIS system.

Frequency-shaped Sliding Mode Control of Isolation Table Equipped with Precision devices (정밀기기가 탑재된 방진대의 주파수성형 슬라이딩모드 제어)

  • 김효준;박영필
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.2
    • /
    • pp.124-131
    • /
    • 2002
  • This paper presents the design of an active vibration suppression controller for an air-spring type vibration isolation table. Firstly, isolation system model is constructed considering the isolation table, attached equipment and voice-coil actuator. An active control system is designed based on frequency-shaped sliding mode control theory rewarding high frequency uncertainties with respect to attached equipments on the isolation table. Finally. the performance of the active isolation system is evaluated by simulation under some disturbance conditions which are transmitted from base structure of the isolation system.

Dynamic Characteristics Analysis of Claw Pole PM Type Step Motor (Claw Pole 영구자석형 스텝모터의 동특성 해석)

  • Gong, Jeong-Sik;Kim, Jong-Cheol;O, Cheol-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.597-603
    • /
    • 1999
  • Due to its simple construction, operation steadiness and low cost, claw pole step motor is widely used for OA machine and automobile. This paper deals with analysis fo claw pole motor, especially eyeing to dynamic characteristics. To analyze dynamic characteristics of claw pole step motor, torque development in each angular step of rotor are surveyed and torque equation is drived using permeance method. To adopt the airgap MMF, the magnetic equivalent circuit of the motor is introduced. On the base of the magnetic equivalent circuit, the air gap flux equation is derived. To get a optimum design of the motor, the torque characteristic is studied in variation of coil data and remanence value of permanent magnetic material.

  • PDF

Steady-state Characteristics of the Piezoelectric Transformer and the Design of the Piezoelectric Inverter for Cold Cathode Fluorescent Lamp (압전 변압기의 정상상태 특성과 고효율 냉 음극 방전램프용 인버터 설계)

  • Gwon, Gi-Hyeon;Im, Yeong-Cheol;Yang, Seung-Hak;Jeong, Yeong-Guk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.4
    • /
    • pp.175-182
    • /
    • 2000
  • The back-light inverter used in the laptop computer is designed in this paper. It has been difficult for electromagnetic transformer to enhance the efficiency and compact profile of the inverter. In this paper, (1) the piezoelectric transformer (PT) is used for reducing the loss; (2) the volumes of core and winding coil are used in electromagnetic transformer, and (3) the half-bridge series parallel resonant circuit is used in the driver of the inverter. The modified PT for this paper and the equivalent circuit are supported by the simulation program. The result of the experiment shows more than 91% improvement in terms of the efficiency.

  • PDF

The Preventive measure and the cause analysis for field coils breaking away from the rotor in hydro generator (수차발전기 회전자 Coil 이탈 원인분석 및 방지대책)

  • Kim, Seung-Hyo;Moon, Hyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1021-1023
    • /
    • 2000
  • This paper presents the preventive measure and the cause for field coils breaking away from the rotor, which lately occurred when No.1 hydro generator was operating in Chung-Ju Dam No.2 Hydro Power Station. In findings, we ascertained the truth of contact between rotor rim and field coils, and think that field coils will break away from the rotor because of mechanical stress according as continuous operation after completion. 1985. Therefore, we conclude that the preventive measure for such a phenomenon is that stopper should be installed between rotor rim and field coils, and bolts should be tightened because of operating characteristic however there are not the design standards for installing stopper in generator rotor internationally.

  • PDF

A Novel Tensile Specimen and Test Machine for Mechanical Properties of MEMS Materials (MEMS 소재의 기계적 특성 평가를 위한 인장형 시편 및 시험기 제작)

  • Park, Jun-Hyub;Kim, Chung-Youb;Lee, Chang-Seun;Choa, Sung-Hoon;Song, Ji-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.258-263
    • /
    • 2004
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of materials used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed an uniaxial testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, new techniques and procedures for measuring strength are described.

  • PDF

A Novel Tensile Specimen and Tensile Tester for Mechanical Properties of Thin Films (박막의 기계적 물성을 위한 새로운 인장 시편 및 인장 시험기)

  • Park, Jun-Hyub;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.6 s.261
    • /
    • pp.644-650
    • /
    • 2007
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of thin film used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed a tensile testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, it is described that new techniques and procedures can be adopted for high cycle fatigue test of a thin film.

Interlaminar Flux Density Distribution at Joints of Overlapping Stacked Electrical Steel and Amorphous Ribbons

  • Erdem, Sezer;Derebasi, Naim
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.190-193
    • /
    • 2010
  • The design of joints in a transformer core significantly affects the transformer's efficiency. Air gaps cause variations in the flux distribution at the joints of the laminations, which depend on the geometry. Two similar samples consisting of electrical steel strips and amorphous ribbons were made. The spatial flux distributions were determined using an array of search coils for each sample. 2D models of these samples were created and examined by finite element analysis. The magnetic flux distribution for each lamination in the samples was computed. The results show that the flux density in amorphous ribbons above and below the air gap starts to approach saturation at lower flux density levels than for electrical steel. The flux density measured using the search coil under the air gap is increased in amorphous ribbons and decreased in the electrical steel with increasing frequency.

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.